Professional Documents
Culture Documents
Power Saving: Series
Power Saving: Series
SQ1000/2000 Series
Metal Seal Rubber Seal
Power 0.4
SV
[Option]
SYJ
W SZ
Saving Standard
Compared to
current model
60 % DOWN
VF
VP4
VQ
0.95 W
1/2
VQ
High pressure Easy valve maintenance 4/5
(1 MPa Metal seal) Mountable with VQC
1/2
one screw.
VQC
4/5
Easy Replacement of
Clip
759 a
SQ1000/2000 Series
Wiring Type
EX510 Flat ribbon
D-sub cable connector Terminal Lead wire kit
Gateway-type connector kit block box kit
serial transmission kit
system
Manifold F kit P kit T kit L kit
variations
SQ1000 —
Plug-in Unit
SQ2000
(P.782) (P.786, 792) (P.786, 794) (P.786, 798) (P.786, 800)
SQ1000 — — —
Plug Lead Unit
SQ2000 — — —
(P.842, 848) (P.842, 850)
Piping Specifications
1(P), 3(R) 4(A), 2(B)
Supply/Exhaust port Cylinder port
Side
ported
SQ1000
One-touch fittings for ø3.2
One-touch fittings for ø4
One-touch fittings for ø6
M5
SQ2000
One-touch fittings for ø4
Top One-touch fittings for ø6
ported One-touch fittings for ø8
SQ1000
One-touch fittings for ø8
SQ2000
One-touch fittings for ø10
A 760
Metal Seal/Rubber Seal
5 Port Solenoid Valve
Contents
Plug-in Unit
Valve Specifications P.770
Manifold Specifications P.771 SV
Manifold Option Parts P.803 SYJ
Serial How to Increase Manifold Stations P.817
Connector kit
transmission kit SZ
Construction P.822
S kit C kit Manifold Exploded View: SQ1000 P.824 VF
Manifold options Manifold Spare Parts: SQ1000 P.825
VP4
Manifold Exploded View: SQ2000 P.826
VQ
Manifold Spare Parts: SQ2000 P.827 1/2
VQ
4/5
Plug Lead Unit VQC
Valve Specifications P.832 1/2
— P.768 VQC
(P.766, 780) Manifold Specifications P.833 4/5
Manifold Option Parts P.856
VQZ
How to Increase Manifold Stations P.869
— P.788
SQ
(P.786, 802) Construction P.874
Manifold Exploded View: SQ1000 P.876
VFS
Manifold Spare Parts: SQ1000 P.877
— P.830 VFR
(P.828, 840) Manifold Exploded View: SQ2000 P.878
Manifold Spare Parts: SQ2000 P.879 VQ7
— P.844
(P.842, 854) Specific Product Precautions P.880
Cylinder Speed Chart Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program.
SQ1000 series SQ2000 series
Average Bore size (mm) Average Bore size (mm)
speed CJ2 series CM2 series speed CJ2 series CM2 series
(mm/s) ø6 ø10 ø16 ø20 ø25 ø32 ø40 (mm/s) ø6 ø10 ø16 ø20 ø25 ø32 ø40
800 Perpendicular,
800 Perpendicular,
700 upward actuation 700 upward actuation
600 600
500 Horizontal 500 Horizontal
actuation actuation
400 400
300 300
200 200
100 100
0 0
∗ It is when the cylinder is extending that is meter-out controlled by speed controller Pressure: 0.5 MPa/Load factor: 50%
which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is what the stroke is divided by the total stroke time.
∗ Load factor: ((Load mass x 9.8) /Theoretical force) x 100%
Conditions
Base mounted CJ2 series CM2 series MB, CA2 series
Tube x Length T0604 x 1 m
SQ1000 Speed controller AS3002F-06
Silencer AN110-01
Tube x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
SQ2000 Speed controller AS3002F-06 AS4002F-10
Silencer AN20-02
761
EX510 Gateway-type Serial Transmission System
Plug-in Unit
SS5Q 1 3 SB 08 D
Manifold series CE/UKCA-compliant
1 SQ1000 Nil —
Q CE/UKCA-compliant
1
- Single and double mixed wiring
ns
tio - When there are stations which do not require
Sta wiring (e.g. single SUP spacer), specify the wiring
specification in the manifold specification so that the
number of the solenoids is 16 maximum. (Standard
wiring specification is double wiring)
Note 5) For specifying two or more options, enter them
alphabetically.
Cylinder port fitting Example: -BKN
C6: One-touch fittings for ø6
6
14
0
15
e
option parts.
sid
8
9
D
Add the valve and option part number under the manifold base part number. Refer to Best Pneumatics No. 1-1 and the Operation Manual
When entry of part numbers becomes complicated, indicate by the manifold for the details of EX510 Gateway-type Serial Transmission System.
specification sheet. Please download it via our website, http://www.smcworld.com
a 762
EX510 Gateway-type Serial Transmission System
Plug-in Unit SQ1000 Series
SQ 1 1 3 0 5 1 C6
Series CE/UKCA-compliant
1 SQ1000 Nil —
Q CE/UKCA-compliant
SV
Seal
0 Metal seal With/Without manifold block SYJ
1 Rubber seal Nil M MB Note)
With manifold block, SZ
Type of actuation Without manifold
With manifold block built-in back pressure
block
2 position single check valve VF
(A)4 2(B)
1
VP4
(R1)5 1 3(R2)
(P)
VQ
2 position double (Double solenoid)(1) 1/2
(A)4 2(B) (A)4 2(B) ∗ Lead wire is not ∗ Lead wire is not VQ
2 included. included. 4/5
(R1)5 1 3(R2) (R1)5 1 3(R2)
• When ordering VQC
(P) (P) with manifolds
For adding stations 1/2
Metal seal Rubber seal • When only valves
are required. VQC
3 position closed center 4/5
(A)4 2(B) Note) Since 4 port specification valves (5 (R1) and 3 (R2) are
3 common) are used, back pressure cannot be prevented with VQZ
dual 3 port valves.
(R1)5 1 3(R2)
(P)
Port plug mounting port SQ
3 position exhaust center
(A)4 2(B)
Nil None
4 A Port 4(A) VFS
(R1)5 1 3(R2) B Port 2(B)
(P) VFR
3 position pressure center Cylinder port
(A)4 2(B) Symbol Port size Port location VQ7
5 C3 With One-touch fittings for ø3.2
(R1)5 1 3(R2) C4 With One-touch fittings for ø4 Side
(P)
C6 With One-touch fittings for ø6 ported
4 position dual 3 port valve
4(A) 2(B) M5 M5 thread
L3 With One-touch fittings for ø3.2
A(2) L4 With One-touch fittings for ø4 (1)
Top
L6 With One-touch fittings for ø6 ported
1(P) 3(R)
L5 M5 thread
4 position dual 3 port valve Note 1) Can be changed to side ported configuration.
4(A) 2(B)
Note 2) Refer to page 815 for the inch-size One-touch fittings.
B(2)
Manual override
1(P) 3(R) Nil B
4 position dual 3 port valve Non-locking push type Locking type
4(A) 2(B) (Tool required) (Tool required)
C(2)
1(P) 3(R)
Note 1) For double solenoid specification,
the function symbol below is “D”.
Note 2) Only rubber seal types are
applicable.
Function
Rated voltage
Symbol Specifications
5 24 VDC
Nil Standard type (0.4 W)
Note) Light/surge voltage suppressor is built-in.
B (5) Quick response type (0.95 W)
D(1) 2 position double (Double solenoid specifications) Note 1) “D” is specified for 2 position double.
High pressure type (1 MPa, 0.95 W) Note 2) When SI unit output polarity is negative common, the valve common
K(5)
[Applicable to metal seal only] specification should be also be negative common.
Note 3) Except dual 3 port valves.
N(2) Negative common
Note 4) When two or more symbols are specified, indicate them alphabetically.
R(3) External pilot specifications Note 5) Function combination of “B” and “K” is not available.
763 a
SQ1000 Series
Dimensions: SQ1000
L3
5 L2
L1
47.6 58.1
Indicator light
49.4 43.5 11.5 26.4
Manual override
113 (Double, Dual 3 port)
108.5 (Single)
123 (3 position)
(108.5)
6
7
5.5
1
9
8
35
47.1
34.3
28.1
PWR
COM
12.7
≈10
One-touch fitting
≈9
[3(R), 1(P) port]
For top ported
Applicable tubing O.D.: ø8
4 4 4 4 4 4 4 4
R 3
60
37
P 1
29.6
2 2 2 2 2 2 2 2
26
13.1
7.5
43.5
58.1 11.5 One-touch fitting, thread piping
[4(A), 2(B) port]
Applicable tubing O.D.: ø3.2
: ø4
: ø6
Thread size: M5
764
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
765
Plug-in Unit
SS5Q13 08 FD2 D
Stations CE/UKCA-compliant
01 1 station Note) The maximum number of 1(P), 3(R) port size Nil —
… … stations depends on the Q CE/UKCA-compliant
Nil 1(P), 3(R) port
24 Note) 24 stations type of electrical entries. One-touch fittings for ø8
Refer to “Electrical entry”
1(P), 3(R) port
for details. 00T
One-touch fittings for ø5/16"
Manifold mounting Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside.) The number
of stations that may be displayed is longer than the manifold number of stations. Example: -D09
D DIN rail mounting type Note 2) When “-B” is selected, a back pressure check valve is included in all stations of the manifold. If
E Note) Direct mounting type Option the back pressure check valve is used only for the station that need it, then specify the station
Note) Refer to page 814 for Nil None location in the manifold specification. (“-B” is not necessary)
details. Note 3) Since 4 port specification valves (5 (R1) and 3 (R2) are common) are used, back pressure
02 to 24 (1) DIN rail length specified cannot be prevented with dual 3 port valves.
B(2)(3) Back pressure check valve Note 4) Specify “-K” for wiring specification for cases below. (Except L kit)
K(4) Special wiring specifications (Except double wiring) - All single wiring
N With name plate (Side ported only) - Single and double mixed wiring.
- When there are stations which do not require wiring (e.g. single SUP spacer), specify
R External pilot specifications the wiring specification in the manifold specification so that the number of solenoids is the
S Built-in silencer, direct exhaust maximum number of solenoids or less. (Standard wiring specification is double wiring)
Note 5) For specifying two or more options, enter them alphabetically. Example: -BKN
∗ Refer to pages 803 to 807 and 813 to 815 for manifold option parts.
Electrical entry
Lead wire Station Max. number of
Kit type connector Cable/SI unit specifications solenoids for special
location (Double wiring) wiring specifications(2)
U side FD0 D-sub connector (25P) kit, without cable
F kit
FD1 D-sub connector (25P) kit, with 1.5 m cable
D side
D side 1 to 12 stations 24
D-sub FD2 D-sub connector (25P) kit, with 3.0 m cable
connector kit FD3 D-sub connector (25P) kit, with 5.0 m cable
PD0 Flat ribbon cable (26P) kit, without cable
P kit
PD1 Flat ribbon cable (26P) kit, with 1.5 m cable
1 to 12 stations 24
PD2 D side (1) Flat ribbon cable (26P) kit, with 3.0 m cable
PD3 Flat ribbon cable (26P) kit, with 5.0 m cable
Flat ribbon cable connector kit ( 26P
20P ) PDC Flat ribbon cable (20P) kit, without cable 1 to 9 stations 18
LD0 (N) D side
L kit Lead wire kit with 0.6 m cable
Note 3) LU0 (N) U side
LD1 (N) D side
Lead wire kit with 1.5 m cable 1 to 12 stations —
LU1 (N) U side
LD2 (N) D side
Lead wire kit Lead wire kit with 3.0 m cable
LU2 (N) U side
S kit SDQ DeviceNet ®
1 to 8 stations 16
Serial transmission kit SDR1 OMRON Corp.: CompoBus/S (16 output points)
EX140 Integrated-type D side
SDR2 OMRON Corp.: CompoBus/S (8 output points) 1 to 4 stations 8
(For Output)
Serial Transmission System(4) SDV CC-LINK 1 to 8 stations 16
Note 1) Separately order the 20P type cable assembly for the P kit.
Note 2) Specify the wiring so that the maximum number of solenoids is not exceeded. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.)
Note 3) When specifying the negative common specifications of the L kit, suffix “N” to the kit symbol. For details, refer to page 778.
Note 4) Refer to Best Pneumatics No. 1-1 and the Operation Manual for the details of EX140 Integrated-type (For Output) Serial Transmission System. Please download it via our website.
http://www.smcworld.com
∗ Refer to page 825 for manifold spare parts.
e 766
Plug-in Unit SQ1000 Series
SQ1 1 3 0 5 1 C6
CE/UKCA-compliant
Nil — SV
Seal Q CE/UKCA-compliant
0 Metal seal SYJ
1 Rubber seal With/Without manifold block
Nil M MB Note) SZ
Type of actuation With manifold block,
Without
With manifold block built-in back pressure
2 position single manifold block
check valve VF
(A)4 2(B)
1
VP4
(R1)5 1 3(R2)
(P)
VQ
2 position double 1/2
(Double solenoid) (1)
(A)4 2(B) (A)4 2(B)
VQ
∗ Lead wire is ∗ Lead wire is 4/5
2 not included. not included.
(R1)5 1 3(R2) (R1)5 1 3(R2) VQC
(P) (P) • When ordering 1/2
Metal seal Rubber seal with manifolds
For adding stations VQC
• When only valves
3 position closed center are required. 4/5
(A)4 2(B)
Note) Since 4 port specification valves (5 (R1) and 3 (R2) are
3
common) are used, back pressure cannot be prevented with
VQZ
(R1)5 1 3(R2) dual 3 port valves.
(P)
SQ
3 position exhaust center Port plug mounting port
(A)4 2(B) Nil None
4 VFS
A Port 4(A)
(R1)5 1 3(R2) B Port 2(B)
(P) VFR
3 position pressure center
Cylinder port
(A)4 2(B)
Symbol Port size Port location
VQ7
5
(R1)5 1 3(R2) C3 With One-touch fittings for ø3.2
(P) C4 With One-touch fittings for ø4 Side
4 position dual 3 port valve C6 With One-touch fittings for ø6 ported
4(A) 2(B)
M5 M5 thread
A(2) L3 With One-touch fittings for ø3.2
(1)
L4 With One-touch fittings for ø4 Top
1(P) 3(R) L6 With One-touch fittings for ø6 ported
4 position dual 3 port valve L5 M5 thread
4(A) 2(B) Note 1) Can be changed to side ported configuration.
Note 2) Refer to page 815 for the inch-size One-touch fittings.
B(2)
Manual override
1(P) 3(R) Nil B
4 position dual 3 port valve Rated voltage Non-locking push type Locking type
4(A) 2(B) 5 24 VDC (Tool required) (Tool required)
6 12 VDC
C(2)
Note 1) Light/surge voltage
suppressor is built-in.
1(P) 3(R) Note 2) S kit: 24 VDC only
Note 1) For double solenoid
specification, the function
symbol below is “D”.
Note 2) Only rubber seal types are Function
applicable. Symbol Specifications
Nil Standard type (0.4 W) Note 1) “D” is specified for 2 position double.
Note 2) For L kit, when the manifold specifies negative
B (5) Quick response type (0.95 W)
common, the valve common should also be
D(1) 2 position double (Double solenoid specifications) negative. The combination of negative common of
High pressure type (1 MPa, 0.95 W) the valve cannot be specified with S kit (EX140).
K(5) [Applicable to metal seal only] Note 3) Except dual 3 port valves.
Note 4) When two or more symbols are specified, indicate
N(2) Negative common
them alphabetically.
R(3) External pilot specifications Note 5) Function combination of “B”and “K” is not available.
767 a
SQ1000 Series
Manifold Options
Blanking plate Individual SUP/EXH spacer Name plate (-N) External pilot
SSQ1000-10A-3 P.803 SSQ1000-PR1-3-C6 L6 P.804 SSQ1000-N3-n P.806 specifications (-R) P.807
External pilot port
SUP/EXH block SUP block plate Blanking plug Dual flow fitting
SSQ1000-PR-3-C8(-S) SSQ1000-B-P P.805 KQ2P-23 / 04 / 06/08 SSQ1000-52A- C8
N9 P.807
P.803 P.806
D side
U side
D side
U side
Individual EXH spacer Back pressure check valve (-B) Built-in silencer, Special wiring specifications (-K)
SSQ1000-R-3-C6 L6 P.804 SSQ1000-BP P.805 direct exhaust (-S) P.806 P.813
D-sub connector Terminal no.
SOL.A
1 station 1 (−)
SOL.A
2 stations 14 (−)
SOL.A
1
3 stations 2 (−)
14 SOL.A
2 4 stations 15 (−)
15 SOL.A
3 3 (−)
16
17
4 5 stations SOL.B
16 (−)
5
18 SOL.A
6 4 (−)
19 6 stations
7 SOL.B
20 17 (−)
8 SOL.A
21 5 (−)
9
22
10
7 stations SOL.B
23 18 (−)
11 SOL.A
24 6 (−)
12 8 stations
25 SOL.B
13 19 (−)
COM.
13 (+)
768
Plug-in Unit SQ1000 Series
4
3
2
1
tion
s VF
Sta
VP4
VQ
1/2
D-sub connector cable VQ
AXT100-DS25-030 4/5
VQC
Cylinder port fitting 1/2
ide C6: One-touch fitting for ø6 VQC
Ds 4/5
Manifold base (9 stations)
F kit SS5Q13-09FD2-D VQZ
(D-sub connector kit)
SQ
VFS
SS5Q13-09FD2-D ··········· 1 set (F kit 9-station manifold base)
∗ SQ1130-51-C6 ·············· 4 sets (2 position single) VFR
∗ SQ1230D-51-C6 ··········· 4 sets (2 position double)
∗ SSQ1000-10A-3 ··········· 1 set (Blanking plate) VQ7
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part numbers in order starting from the first station on the D side.
When entry of part numbers becomes complicated, indicate on the manifold specification sheet.
769
SQ1000 Series
Valve Specifications
Model
Flow rate characteristic (1) Response time (ms) (2)
Type of Weight
Series Seal Model 1 → 4/2 (P → A/B) 4 → 5 (A → R1) Standard Quick response
actuation (g)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv (0.4 W) (0.95 W)
Metal seal SQ1130 0.62 0.10 0.14 0.63 0.11 0.14 26 or less 12 or less 80
Single
2 position
Rubber seal SQ1131 0.79 0.20 0.19 0.80 0.20 0.19 24 or less 15 or less 80
Metal seal SQ1230D 0.62 0.10 0.14 0.63 0.11 0.14 13 or less 10 or less 95
Double
Rubber seal SQ1231D 0.79 0.20 0.19 0.80 0.20 0.19 20 or less 15 or less 95
Closed Metal seal SQ1330 0.58 0.12 0.14 0.63 0.11 0.14 44 or less 29 or less 100
center Rubber seal SQ1331 0.64 0.20 0.15 0.58 0.26 0.16 39 or less 25 or less 100
SQ1000
3 position
Exhaust Metal seal SQ1430 0.58 0.12 0.14 0.60 0.14 0.14 44 or less 29 or less 100
center Rubber seal SQ1431 0.64 0.20 0.15 0.80 0.20 0.19 39 or less 25 or less 100
Pressure Metal seal SQ1530 0.62 0.12 0.14 0.63 0.14 0.14 44 or less 29 or less 100
center Rubber seal SQ1531 0.79 0.21 0.19 0.59 0.20 0.14 39 or less 25 or less 100
4 position
Dual A
Rubber seal SQ1B 31 0.59 0.28 0.15 0.59 0.28 0.15 27 or less 14 or less 95
3 port valve C
Note 1) Values for the cylinder port size of C6, CYL → Values of EXH. Flow rate characteristics of 2 → 3 (B → R2) delines about 30% of 4 → 5 (A → R1).
Note 2) Based on JIS B 8419: 2010. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the
pressure and air quality.
Specifications
Valve construction Metal seal Rubber seal
Fluid Air
Maximum operating pressure 0.7 MPa (High pressure type (3): 1.0 MPa)
Valve specifications
3 position closed center 3 position pressure center 4 position dual 3 port valve (B)
4(A) 2(B)
(A)4 2(B) (A)4 2(B)
4 position dual 3 port valve (A) 4 position dual 3 port valve (C)
3 position exhaust center
4(A) 2(B) 4(A) 2(B)
(A)4 2(B)
(R1)5 1 3(R2)
(P)
1(P) 3(R) 1(P) 3(R)
770
Plug-in Unit SQ1000 Series
Manifold Specifications
Porting specifications
Addition
Port size (1) Applicable Applicable 5-station
per
Base model solenoid Type of connection stations (3) weight (4)
4(A), 2(B) station (4)
valve (Double wiring) (g)
1(P), 3(R) Port (g)
location Port size SV
C3 (For ø3.2) F kit: D-sub connector 1 to 12 stations 420 20
C8 Side C4 (For ø4) SYJ
(For ø8) C6 (For ø6) 26P 1 to 12 stations
M5 (M5 thread)
SQ130
P kit: Flat ribbon cable
20P 1 to 9 stations
420 20 SZ
SS5Q13-- Option SQ131
Built-in
silencer,
L3 (For ø3.2) L kit: Lead wire 1 to 12 stations 460 35 VF
L4 (For ø4)
direct exhaust Top (2) L6 (For ø6)
L5 (M5 thread) S kit: Serial transmission 1 to 8 stations 475 20 VP4
Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 815.
VQ
Note 2) Can be changed to side ported configuration.
1/2
Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 813 for details. VQ
Note 4) Except valves. For valve weight, refer to page 770. 4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
4(A), 2(B) port
VFR
3(R) port
F kit P kit
EX140
L kit Refer to Best Pneumatics No. 1-1 and the Operation Manual for the details
of EX140 Integrated-type (For Output) Serial Transmission System.
Please download it via our website, http://www.smcworld.com
S kit
771 A
SQ1000 Series
Cable Assembly
015 s
AXT100-DS25- 030 tion
050 ··· sta
·····
The D-sub connector cable assemblies can be ordered with 3 ··
manifolds. Refer to “How to Order Manifold.” ide 12
Ds
D-sub Connector ∗ Valves are numbered from the D side.
Cable Assembly Electrical Wiring Specifications
Terminal No.
Cable Terminal Lead wire Dot D-sub connector
0.3 mm2 x 25 cores number color marking
O.D. ø1.4 As the standard electrical wiring specifications,
≈ø10 1 Black None
double wiring (connected to SOL. A and SOL.
2 Brown None 14
1
2 B) is adopted for the internal wiring of each
Seal 3 Red None 15
16
3
station for 12 stations or less, regardless of
4
015 (Length indication) 4 Orange None 17
5 valve and option types.
18
5 Yellow None 19
6
Mixed single and double wiring is available as
L
7
Molded cover 6 Pink None 20
21
8 an option.
9
2 x M2.6 x 0.45 7 Blue None 22
10
For details, refer to page 813.
23
44
772
Plug-in Unit SQ1000 Series
L4 SV
5 L3
49.4 L2 SYJ
47 10.3 L1
25 47.8 P=11.5 19.2 Indicator light SZ
20.5 33.2 1.5
(Mounting hole M5: External pilot port 1.5
Manual override VF
dimension)
VP4
113.1 (Double, Dual 3 port valve)
VQ
1/2
4.6
10
VQ
108.5 (Single)
122 (3 position)
4/5
(108.5)
VQC
93.7
1/2
74.5
VQC
35
4/5
47.1
5.5
34.3
VQZ
28.1
12.7
2 x M4
SQ
DIN rail clamp screw
≈10
VFS
≈9
≈9
One-touch fitting
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø8
4 4 4 4 4 4 4 4
R 3
60
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
43.5
7.5
773
SQ1000 Series
Cable Assembly s
tion
1 sta
AXT100-FC 20
26 - 2 ········
3 3 ··
12
Type 26P flat ribbon cable connector assemblies can be ide
ordered with manifolds. Refer to "How to Order Manifold". Ds
∗ Valves are numbered from the D side.
Electrical Wiring Specifications
6 Terminal no. 28AWG
Red Flat ribbon cable connector
26 25
30 (20P)
37.5(26P)
25
16 15
14 13 For details, refer to page 813.
12 11
(15.6) 10 9
8 7
L 6 5 Connector terminal no.
4 3
2 1
Triangle mark indicator position
Flat Ribbon Cable Connector Assembly
Cable Assembly part no. <26P> <20P>
length (L) 26P 20P Terminal no. Polarity Terminal no. Polarity
1.5 m AXT100-FC26-1 AXT100-FC20-1 SOL.a SOL.a
1 (−) (+) 1 (−) (+)
3m AXT100-FC26-2 AXT100-FC20-2 1 station SOL.b 1 station SOL.b
2 (−) (+) 2 (−) (+)
5m AXT100-FC26-3 AXT100-FC20-3 SOL.a SOL.a
3 (−) (+) 3 (−) (+)
2 stations SOL.b 2 stations SOL.b
∗ For other commercial connectors, use a 26 pins or 20 pins with 4 (−) (+) 4 (−) (+)
SOL.a SOL.a
strain relief conforming to MIL-C-83503. 5 (−) (+) 5 (−) (+)
3 stations SOL.b 3 stations SOL.b
∗ Cannot be used for movable wiring. 6 (−) (+) 6 (−) (+)
∗ Lengths other than the above are also available. Please contact SOL.a SOL.a (+)
7 (−) (+) 7 (−)
SMC for details. 4 stations SOL.b 4 stations SOL.b
8 (−) (+) 8 (−) (+)
SOL.a (+) SOL.a (−) (+)
9 (−) 9
5 stations SOL.b 5 stations SOL.b
Connector manufacturers’ example 10 (−) (+) 10 (−) (+)
SOL.a (+) SOL.a (−) (+)
11 (−) 11
• HIROSE ELECTRIC CO., LTD. 6 stations SOL.b 6 stations SOL.b
12 (−) (+) 12 (−) (+)
• 3M Japan Limited SOL.a SOL.a
13 (−) (+) 13 (−) (+)
• Fujitsu Limited 7 stations SOL.b 7 stations SOL.b
• Japan Aviation Electronics Industry, Limited 14 (−) (+) 14 (−) (+)
SOL.a (+) SOL.a (−) (+)
• J.S.T. Mfg. Co., Ltd. 15 (−) 15
8 stations SOL.b (+)
8 stations SOL.b (−) (+)
• Oki Electric Cable Co,. Ltd. 16 (−) 16
SOL.a (−) (+) SOL.a (−) (+)
17 17
9 stations SOL.b 9 stations SOL.b (−) (+)
18 (−) (+) 18
SOL.a 19 (−) (+) COM.
10 stations SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+)
11 stations SOL.b Positive Negative
22 (−) (+)
common common
SOL.a 23 (−) (+) specifications specifications
12 stations SOL.b (+)
24 (−)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common
specifications specifications
774
Plug-in Unit SQ1000 Series
L4 SV
5 L3
49.4
L2 SYJ
10.3 L1
47
25
47.8 P=11.5 19.2 Indicator light SZ
M5: External pilot port 33.2 1.5
20.5
(Mounting hole 1.5
Manual override VF
dimension)
VP4
113.1 (Double, Dual 3 port valve)
VQ
4.6
1/2
10
VQ
108.5 (Single)
122 (3 position)
4/5
108.5
VQC
93.7
1/2
74.5
VQC
35
4/5
47.1
5.5
34.3
VQZ
28.1
12.7
2 x M4
SQ
DIN rail clamp screw
≈10
VFS
Applicable connector: EXH outlet
≈9
Triangle mark
Flat ribbon cable connector (26P)
(Conforming to MIL-C-83503)
indicator position VFR
Release for switching connector direction VQ7
One-touch fitting
[3(R), 1(P) port] ≈9
Applicable tubing O.D.: ø8
For top ported
4 4 4 4 4 4 4 4
R 3
60
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
43.5
7.5
775
A 776
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
777 A
SQ1000 Series
ide
Us
ns
atio
····· st
3 ·····
ide 12
Ds
∗ Valves are numbered from the D side.
Wiring Specifications: Positive Common Specifications Wiring Specifications: Negative Common Specifications (Semi-standard)
Three lead wires are included per station regardless of valves used. Three lead wires are included per station regardless of valves used.
Among the three lead wires, the red wire is for COM. Among the three lead wires, the black wire is for COM.
Lead wire color Lead wire color Lead wire color Lead wire color
SOL.A SOL.A SOL.A SOL.A
(−) Black (−) Black (+) Red (+) Red
COM(+) Red COM(+) Red COM(−) Black COM(−) Black
SOL.B SOL.B SOL.B SOL.B
(−) White (−) White (+) White (+) White
Electrical entry
G1/2 L4 SV
5 L3
49.4
47
L2 SYJ
7.3 L1
31.8
20.5 Station number 36.9 P=11.5 19.2 Indicator light SZ
22.3 1.5
(Mounting hole AWG24
dimension) Lead wire 1.5
Manual override VF
VP4
113.1 (Double, Dual 3 port valve)
VQ
1/2
VQ
108.5 (Single)
122 (3 position)
4/5
4.6
10
(108.5)
VQC
1/2
74.5
74.5
VQC
35
4/5
47.1
5.5
34.3
VQZ
28.1
12.7
2 x M4
SQ
DIN rail clamp screw
≈9
≈10
VFS
M5: External pilot port EXH outlet
VFR
D side Stations 1 2 3 4 5 6 7 8 n U side VQ7
≈9
One-touch fitting
Lead wire length: L0, ≈0.6 m
[3(R), 1(P) port] For top ported
L1, ≈1.5 m
L2, ≈3.0 m Applicable tubing O.D.: ø8
4 4 4 4 4 4 4 4
R 3
60
(49.4)
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
29.5
7.5
779
SQ1000 Series
Kit (Serial Transmission Unit)
S EX140 Integrated-type (For Output) Serial Transmission System
Indicator light
L4
5 L3
L2
M5: External pilot port L1
49.4 59.3 P=11.5 19.2
47 44.7 1.5
Manual override
EX140-SCS1
SERIAL UNIT
No.
113.1 (Double, Dual 3 port valve)
BS+
BDH BDL
108.5 (Single)
101
BS-
FG
24V
74.5
ADDRESS No.
0V
35
47.1
5.5
34.3
4.6
10
28.1
12.7
≈10
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
66.9
7.5
780
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
781
EX510 Gateway-type Serial Transmission System
Plug-in Unit
SS5Q 2 3 SB 08 D
CE/UKCA-compliant
Manifold series
Nil —
2 SQ2000
Q CE/UKCA-compliant
6
7
0
1
Cylinder port fitting
8
C6: One-touch fittings for ø6
e
9
D
a 782
EX510 Gateway-type Serial Transmission System
Plug-in Unit SQ2000 Series
SQ 2 1 3 0 5 1 C6
Series CE/UKCA-compliant
2 SQ2000 Nil — SV
Q CE/UKCA-compliant
Seal
SYJ
With/Without manifold block
0 Metal seal
1 Rubber seal
Nil M MB
SZ
With manifold block,
Without With
Type of actuation built-in back pressure
2 position single
manifold block manifold block
check valve VF
(A)4 2(B)
1 VP4
(R1)5 1 3(R2)
(P)
VQ
1/2
2 position double
(Double solenoid) (1) VQ
(A)4 2(B) (A)4 2(B) ∗ Lead wire is ∗ Lead wire is 4/5
2 not included. not included. VQC
(R1)5 1 3(R2) (R1)5 1 3(R2) • When ordering 1/2
(P) (P) with manifolds
Metal seal Rubber seal For adding stations VQC
• When only valves 4/5
3 position closed center are required.
(A)4 2(B)
VQZ
3 Port plug mounting port
(R1)5 1 3(R2)
(P)
Nil None SQ
A Port 4(A)
3 position exhaust center
(A)4 2(B) B Port 2(B) VFS
4
(R1)5 1 3(R2) Cylinder port VFR
(P)
Symbol Port size Port location
3 position pressure center
C4 One-touch fittings for ø4 VQ7
(A)4 2(B) Side
5 C6 One-touch fittings for ø6
ported
(R1)5 1 3(R2)
C8 One-touch fittings for ø8
(P) L4 One-touch fittings for ø4 (1)
Top
4 position dual 3 port valve L6 One-touch fittings for ø6
4(A) 2(B) ported
L8 One-touch fittings for ø8
A (2) Note 1) Can be changed to side ported configuration.
Note 2) Refer to page 815 for the inch-size One-touch fittings.
5(R1) 1(P) 3(R2)
Manual override
4 position dual 3 port valve
4(A) 2(B) Nil B D
Slide locking type
B (2) Non-locking push type Locking type
(Manual type)
(Tool required) (Tool required)
∗ Only side ported type applicable
5(R1) 1(P) 3(R2)
4 position dual 3 port valve
4(A) 2(B)
C (2)
Dimensions: SQ2000
L3
5 L2
L1
5.5
35
A 4
9
8
1
0
COM
PWR
53.6
56
B 2
37.6
SI unit
�≈12
2 x M4
DIN rail clamp screw
≈10
[3(R), 1(P) port]
Applicable tubing O.D.: ø10
(58.1)
62.1
41.7
39.4
25.7
20.9
784
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
785
Plug-in Unit
f 786
Plug-in Unit SQ2000 Series
SQ2 1 3 0 5 1 C6
CE/UKCA-compliant
Seal
0 Metal seal
Nil — SV
Q CE/UKCA-compliant
1 Rubber seal
SYJ
Type of actuation With/Without manifold block
2 position single
(A)4 2(B)
Nil M MB
SZ
With manifold block,
1 Without With
built-in back pressure
(R1)5 1 3(R2)
manifold block manifold block
check valve VF
(P)
2 position double VP4
(Double solenoid) (1)
(A)4 2(B) (A)4 2(B) VQ
2 1/2
(R1)5 1 3(R2) (R1)5 1 3(R2) VQ
(P) (P) ∗ Lead wire is ∗ Lead wire is 4/5
Metal seal Rubber seal
not included. not included. VQC
3 position closed center 1/2
• When ordering
(A)4 2(B)
with manifolds VQC
3 For adding stations
• When only valves 4/5
(R1)5 1 3(R2) are required.
(P)
3 position exhaust center
VQZ
(A)4 2(B)
Port plug mounting port
4 Nil None SQ
(R1)5 1 3(R2) A Port 4(A)
(P) B Port 2(B) VFS
3 position pressure center
(A)4 2(B) Cylinder port VFR
5 Symbol Port size Port location
(R1)5 1 3(R2)
(P)
C4 With One-touch fittings for ø4
Side
VQ7
C6 With One-touch fittings for ø6
4 position dual 3 port valve ported
4(A) 2(B) C8 With One-touch fittings for ø8
L4 With One-touch fittings for ø4 (1)
A (2) Top
L6 With One-touch fittings for ø6 ported
L8 With One-touch fittings for ø8
5(R1) 1(P) 3(R2)
Note 1) Can be changed to side ported configuration.
4 position dual 3 port valve Note 2) Refer to page 815 for the inch-size One-touch fittings.
4(A) 2(B)
B (2)
Manual override
Nil B D
5(R1) 1(P) 3(R2)
Slide locking type
4 position dual 3 port valve Non-locking push type Locking type
(Manual type)
4(A) 2(B) (Tool required) (Tool required)
∗ Only side ported type applicable
C (2)
Manifold Options
Blanking plate Individual SUP/EXH spacer Name plate (-N) External pilot
SSQ2000-10A-3 P.808 SSQ2000-PR1-3- C8
L8 SSQ2000-N3-n P.811 specifications (-R) P.812
P.809 External pilot port
SUP/EXH block SUP block plate Blanking plug Dual flow fitting
SSQ2000-PR-3-C10(-S) SSQ1000-B-R P.810 KQ2P-04 / 06 / 08/10 SSQ2000-52A- C10
N11 P.812
P.808 P.811
D side
U side
D side
U side
Individual EXH spacer Back pressure check valve (-B) Built-in silencer, Special wiring specifications (-K)
SSQ2000-R-3-C8 L8 P.809 SSQ2000-BP P.810 direct exhaust (-S) P.811 P.813
D-sub connector Terminal no.
SOL.A
1 station 1 (–)
SOL.A
2 stations 14 (–)
SOL.A
1
3 stations 2 (–)
14 SOL.A
15
2 4 stations 15 (–)
3 SOL.A
16 3 (–)
17
4 5 stations SOL.B
5 16 (–)
18 SOL.A
6 4 (–)
19 6 stations
7 SOL.B
20 17 (–)
8
21 SOL.A
9 5 (–)
22
10 7 stations SOL.B
23 18 (–)
11 SOL.A
24 6 (–)
12
25 8 stations SOL.B
13 19 (–)
COM.
13 (+)
788
Plug-in Unit SQ2000 Series
1
ns
VF
tio
Sta
VP4
VQ
1/2
VQ
D-sub connector cable 4/5
AXT100-DS25-030 VQC
1/2
VQC
ide Cylinder port fitting 4/5
Ds
C8: One-touch fittings for ø8
VQZ
Manifold base (8 stations)
F kit
(D-sub connector kit)
SS5Q23-08FD2-D SQ
VFS
SS5Q23-08FD2-D ··· 1 set (F kit 8-station manifold base) VFR
∗ SQ2130-51-C8 ····· 3 sets (2 position single)
∗ SQ2230D-51-C8 ··· 3 sets (2 position double) VQ7
∗ SQ2330-51-C8 ····· 1 set (3 position closed center)
∗ SSQ2000-10A-3 ··· 1 set (Blanking plate)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part numbers in order starting from the first station on the D side.
When entry of part numbers becomes complicated, indicate on the manifold specification sheet.
789
SQ2000 Series
Valve Specifications
Model
Flow characteristic (1) Response time (ms) (2)
Type of Weight
Series
actuation
Seal Model 1→4/2 (P→A/B) 4/2→5/3 (A/B→R1/R2) Standard Quick response (g)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv (0.4 W) (0.95 W)
Metal seal SQ2130 2.2 0.17 0.51 2.4 0.14 0.57 35 or less 20 or less 145
Single
2 position
Rubber seal SQ2131 2.3 0.17 0.51 3.1 0.18 0.71 31 or less 24 or less 140
Metal seal SQ2230D 2.2 0.17 0.51 2.4 0.14 0.57 20 or less 15 or less 160
Double
Rubber seal SQ2231D 2.3 0.17 0.51 3.1 0.18 0.71 26 or less 20 or less 155
Closed Metal seal SQ2330 1.9 0.17 0.46 2.1 0.15 0.47 56 or less 37 or less 180
center Rubber seal SQ2331 1.9 0.17 0.46 1.8 0.29 0.47 44 or less 34 or less 175
SQ2000
3 position
Exhaust Metal seal SQ2430 1.9 0.17 0.46 2.4 0.14 0.55 56 or less 37 or less 180
center Rubber seal SQ2431 1.9 0.17 0.46 3.1 0.14 0.65 44 or less 34 or less 175
Pressure Metal seal SQ2530 2.3 0.17 0.51 2.1 0.18 0.47 56 or less 37 or less 180
center Rubber seal SQ2531 2.5 0.17 0.56 1.8 0.30 0.47 44 or less 34 or less 175
Dual
4 position
A
3 port Rubber seal SQ2 B 31 1.5 0.17 0.40 1.5 0.17 0.40 34 or less 19 or less 155
C
valve
Note 1) Values for the top ported cylinder port size of C8. CYL → Values of EXH. The side ported type will be about 10% less.
Note 2) Based on JIS B 8419: 2010. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the
pressure and air quality.)
Specifications
Valve construction Metal seal Rubber seal
Fluid Air
Maximum operating pressure 0.7 MPa
Valve specifications
Symbol
Allowable voltage fluctuation ±10% of rated voltage
Solenoid
2 position single
Coil insulation type Equivalent to class B
(A)4 2(B)
Power consumption 24 VDC 0.4 W DC (17 mA), 0.95 W DC (40 mA) (3)
(Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) (3)
(R1)5 1 3(R2)
(P) Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test
2 position double (Double solenoid) was performed at both energized and de-energized states in the axial direction
(A)4 2(B) (A)4 2(B) and at the right angles to the main valve and armature. (Values at the initial
period)
Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
(R1)5 1 3(R2) (R1)5 1 3(R2) direction and at the right angles to the main valve and armature in both
(P) (P) energized and de-energized states every once for each condition.
Metal seal Rubber seal Note 3) Value for quick response type.
3 position closed center 3 position pressure center 4 position dual 3 port valve (B)
4(A) 2(B)
(A)4 2(B) (A)4 2(B)
4 position dual 3 port valve (A) 4 position dual 3 port valve (C)
3 position exhaust center
4(A) 2(B) 4(A) 2(B)
(A)4 2(B)
(R1)5 1 3(R2)
(P)
5(R1) 1(P) 3(R2) 5(R1) 1(P) 3(R2)
790
Plug-in Unit SQ2000 Series
Manifold Specifications
Porting specifications
Addition
Port size (1) Applicable Applicable 5-station
per
Base model solenoid Type of connection stations (3) weight (4)
4(A), 2(B) station (4)
valve (Double wiring) (g)
1(P), 3(R) Port (g)
location Port size SV
F kit: D-sub connector 1 to 12 stations 580 35
C10 Side
C4 (For ø4) SYJ
C6 (For ø6) 26P 1 to 12 stations
(For ø10) C8 (For ø8) P kit: Flat ribbon cable 580 35
SQ230 20P 1 to 9 stations SZ
SS5Q23-- Option
SQ231 T kit: Terminal block
1,165
Built-in
silencer, L4 (For ø4)
1 to 10 stations 620
VF
direct exhaust Top (2) L6 (For ø6) L kit: Lead wire 1 to 12 stations 620 50
L8 (For ø8) VP4
S kit: Serial transmission 1 to 8 stations 650 35
Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 815.
VQ
Note 2) Can be changed to side ported configuration.
1/2
Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 813 for details. VQ
Note 4) Except valves. For valve weight, refer to page 790. 4/5
VQC
1/2
VQC
4/5
VQZ
SQ
4(A), 2(B) port
3(R) port VFS
1(P) port 26P / 20P (P kit)
25P
VFR
EX140
T kit L kit Refer to Best Pneumatics No. 1-1 and the Opera-
tion Manual for the details of EX140 Integrated-type
(For Output) Serial Transmission System.
Please download it via our website,
http://www.smcworld.com
S kit
791 A
SQ2000 Series
Cable Assembly
015 ons
AXT100-DS25- 030 tati
····· s
·····
050
3
D-sub connector cable assemblies can be ordered with manifolds. 12
Refer to manifold ordering. ide
Ds
D-sub Connector ∗ Valves are numbered from the D side.
Cable Assembly Electrical Wiring Specifications
Terminal No.
Cable D-sub connector
Terminal Lead wire Dot
0.3 mm2 x 25 cores
number color marking
O.D. ø1.4 As the standard electrical wiring specifications,
≈ø10 1 Black None
double wiring (connected to SOL. A and SOL.
2 Brown None 14
1
15
2 B) is adopted for the internal wiring of each
Seal 3 Red None 16
3
station for 12 stations or less, regardless of
4
015 (Length indication) 4 Orange None 17
5 valve and option types.
18
5 Yellow None 19
6
Mixed single and double wiring is available as
L
7
Molded cover 6 Pink None 20
21
8 an option.
9
2 x M2.6 x 0.45 7 Blue None 22
10
For details, refer to page 813.
23
44
792
Plug-in Unit SQ2000 Series
SV
L4
5 L3 SYJ
L2
58.1 M5: External pilot port 15.5 L1 Indicator light SZ
25 47.8 P=17.5 28.8
Release for switching
18.2
(Mounting hole
connector direction
1
29
Manual VF
dimension)
override
VP4
≈12 131.5 (Single, Double, Dual 3 port valve)
5.5
VQ
10.4
1/2
2 x M4
DIN rail VQ
clamp screw 4/5
147 (3 position)
(131.5)
VQC
122.3
A 4
35
1/2
SMC
VQC
5.5
4/5
69.8
55.9
53.6
VQZ
B 2
37.6
18.5
SQ
VFS
≈12
≈10
One-touch fitting
For top ported
[3(R), 1(P) port]
Applicable tubing O.D.: ø10
A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4
R 3
(58.1)
62.1
41.7
39.4
25.7
20.9
2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B
P 1
44.5
7.5
793
SQ2000 Series
Cable Assembly s
tion
1 sta
AXT100-FC 20
26 - 2 ········
3 3 ··
ide 12
Type 26P flat ribbon cable connector assemblies can be Ds
ordered with manifolds. Refer to "How to Order manifold".
∗ Valves are numbered from the D side.
Electrical Wiring Specifications
6 Terminal no. 28AWG
Red Flat ribbon cable connector
26 25
30 (20P)
37.5(26P)
25
16 15
14 13 For details, refer to page 813.
12 11
(15.6) 10 9
8 7
L 6 5 Connector terminal no.
4 3
2 1
Triangle mark indicator position
Flat Ribbon Cable Connector Assembly
Cable Assembly part no. <26P> <20P>
length (L) 26P 20P Terminal no. Polarity Terminal no. Polarity
1.5 m AXT100-FC26-1 AXT100-FC20-1 SOL.a SOL.a
1 (−) (+) 1 (−) (+)
3m AXT100-FC26-2 AXT100-FC20-2 1 station SOL.b 1 station SOL.b
2 (−) (+) 2 (−) (+)
5m AXT100-FC26-3 AXT100-FC20-3 SOL.a SOL.a
3 (−) (+) 3 (−) (+)
2 stations SOL.b 2 stations SOL.b
∗ For other commercial connectors, use a 26 pins or 20 pins with 4 (−) (+) 4 (−) (+)
SOL.a SOL.a
strain relief conforming to MIL-C-83503. 5 (−) (+) 5 (−) (+)
3 stations SOL.b 3 stations SOL.b
∗ Cannot be used for movable wiring. 6 (−) (+) 6 (−) (+)
∗ Lengths other than the above are also available. Please contact SOL.a SOL.a (+)
7 (−) (+) 7 (−)
SMC for details. 4 stations SOL.b 4 stations SOL.b
8 (−) (+) 8 (−) (+)
SOL.a (+) SOL.a (−) (+)
9 (−) 9
5 stations SOL.b 5 stations SOL.b
Connector manufacturers’ example 10 (−) (+) 10 (−) (+)
SOL.a (+) SOL.a (−) (+)
11 (−) 11
• HIROSE ELECTRIC CO., LTD. 6 stations SOL.b 6 stations SOL.b
12 (−) (+) 12 (−) (+)
• 3M Japan Limited SOL.a SOL.a
13 (−) (+) 13 (−) (+)
• Fujitsu Limited 7 stations SOL.b 7 stations SOL.b
• Japan Aviation Electronics Industry, Limited 14 (−) (+) 14 (−) (+)
SOL.a (+) SOL.a (−) (+)
• J.S.T. Mfg. Co., Ltd. 15 (−) 15
8 stations SOL.b (+)
8 stations SOL.b (−) (+)
• Oki Electric Cable Co,. Ltd. 16 (−) 16
SOL.a (−) (+) SOL.a (−) (+)
17 17
9 stations SOL.b 9 stations SOL.b (−) (+)
18 (−) (+) 18
SOL.a 19 (−) (+) COM.
10 stations SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+)
11 stations SOL.b Positive Negative
22 (−) (+)
common common
SOL.a 23 (−) (+) specifications specifications
12 stations SOL.b (+)
24 (−)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common
specifications specifications
794
Plug-in Unit SQ2000 Series
SV
L4
5 L3
SYJ
L2 Indicator
58.1 M5: External pilot port 15.5 L1 light SZ
25 47.8 P=17.5 28.8
Release for switching
18.2
(Mounting hole connector direction
29
Manual
VF
dimension)
1
override
VP4
≈12 131.5 (Single, Double, Dual 3 port valve)
5.5
VQ
10.4
1/2
2 x M4
DIN rail VQ
clamp screw 4/5
147 (3 position)
(131.5)
VQC
122.3
1/2
A 4
35
SMC
VQC
5.5
4/5
69.8
53.6
55.9
VQZ
B 2
37.6
18.5
SQ
VFS
≈12
Triangle mark
EXH outlet
VFR
indicator position
Applicable connector:
Flat ribbon cable connector (26P)
VQ7
D side Stations 1 2 3 4 5 6 7 8 n U side
(Conforming to MIL-C-83503)
One-touch fitting
≈10
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø10
A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4
R 3
(58.1)
62.1
41.7
39.4
25.7
2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B
20.9
P 1
44.5
7.5
795
A 796
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
797 A
SQ2000 Series
This kit has a small terminal box inside a junction box. The Manifold Specifications
electrical entry port (G3/4) permits connection of conduit Porting specifications Maximum
fittings. Series Port size number of
Port
The maximum number of stations is 10 (16 as a semi-standard). location stations
1(P), 3(R) 4(A), 2(B)
10 stations
SQ2000 Side, Top C10 C4, C6, C8 (16 as a semi-standard)
ide
Us
ns
atio
····· st
3 ·····
12
ide 2 x G 3/4"
Ds Electrical entry
∗ Valves are numbered from the D side.
Electrical Wiring Specifications
As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is
adopted for the internal wiring of each station for 10 stations or less, regardless of valve and option
types.
Mixed single and double wiring is available as an option.
For details, refer to page 813.
Terminal no. Polarity
SOL.a
1A (−) (+)
1 station SOL.b
1B (−) (+)
1A
1B
SOL.a
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
2A (−) (+)
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B
2A
2 stations SOL.b
2B
2B (−) (+)
3A
3B
SOL.a
3A (−) (+)
4A
3 stations SOL.b
4B
3B (−) (+)
5A
5B
SOL.a
4A (−) (+)
6A
4 stations
6B
SOL.b
4B (−) (+)
7A
7B
SOL.a
5A (−) (+)
8A
5 stations
8B
SOL.b
5B (−) (+)
9A 10A COM
9B 10B
SOL.a
6A (−) (+)
6 stations SOL.b
6B (−) (+)
SOL.a
7A (−) (+)
7 stations SOL.b
7B (−) (+)
SOL.a
8A (−) (+)
8 stations SOL.b
8B (−) (+)
SOL.a
9A (−) (+)
9 stations SOL.b
9B (−) (+)
SOL.a
10A (−) (+)
10 stations SOL.b
10B (−) (+)
798
Plug-in Unit SQ2000 Series
SV
L4 SYJ
5 L3
10 67 L2 Indicator SZ
L1 light
48.8
30
P=17.5 28.8 VF
1 Manual
override VP4
131.5 (Single, Double, Dual 3 port valve)
D side
U side
VQ
1/2
2 x M4
VQ
147 (3 position)
5.5
DIN rail
4/5
(131.5)
clamp screw
122.3
VQC
35
A 4
1/2
69.8
VQC
55.9
53.6
4/5
B 2
37.6
18.5
VQZ
SQ
M5: External pilot port
≈12
58.1
VFS
≈12
77 EXH outlet
D side 1 2 3 4 5 6 7 8 n U side
One-touch fitting
Stations
VFR
[3(R), 1(P) port]
Applicable tubing O.D.: ø10 VQ7
2 x G 3/4"
Electrical entry
≈10
For top ported
R 3
(77)
62.1
41.7
39.4
45
25.7
20.9
P 1
30
7.5
799
SQ2000 Series
ide
Us
ons
tati
····· s
3 ·····
12
ide
Ds
∗ Valves are numbered from the D side.
Wiring Specifications: Positive Common Specifications Wiring Specifications: Negative Common Specifications (Semi-standard)
Three lead wires are included per station regardless of valves used. Three lead wires are included per station regardless of valves used.
Among the three lead wires, the red wire is for COM. Among the three lead wires, the black wire is for COM.
Lead wire color Lead wire color Lead wire color Lead wire color
SOL.A SOL.A SOL.A (+) SOL.A (+)
(−) Black (−) Black Red Red
COM(+) Red COM(+) Red COM(−) Black COM(−) Black
SOL.B SOL.B SOL.B SOL.B
(−) White (−) White (+) White (+) White
SV
L4
58.1 5 L3 SYJ
33.4 L2 Indicator
Station number
18.2 L1 light SZ
(Mounting hole 15.2 48.8 P=17.5 28.8
dimension)
Electrical entry AWG24 10.4 30
Manual
VF
G 1/2 Lead wire 5.5 1
override
VP4
≈12 131.5 (Single, Double, Dual 3 port valve)
VQ
1/2
2 x M4
DIN rail VQ
4/5
5.5
clamp screw
147 (3 position)
(131.5)
VQC
122.3
1/2
A 4
35
103.3
SMC
VQC
4/5
69.8
53.6
55.9
VQZ
B 2
37.6
18.5
SQ
VFS
≈12
≈10
Lead wire length: L0, ≈0.6 m
For top ported
L1, ≈1.5 m
L2, ≈3.0 m
A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4
R 3
62.1
(58)
41.7
39.4
25.7
2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B
20.9
P 1
30
7.5
801
SQ2000 Series
Kit (Serial Transmission Unit)
S EX140 Integrated-type (For Output) Serial Transmission System
L4
5 L3 Indicator
L2 light
SI unit L1
58.1 M5: External pilot port 47.8 P=17.5 28.8
29 Manual
override
EX140-SMJ1
SERIAL UNIT
131.5 (Single, Double, Dual 3 port valve)
24V
2 x M4
L ERR.SD
PWR.
0V
DIN rail
+24V 24G
5.5
L RUN
clamp screw
RD
147 (3 position)
(131.5)
DA
B RATE
DB
A 4
35
DG
0
STATION No.
FG
69.8
5.5
55.9
53.6
B 2
37.6
10.4
18.5
1 1
≈12
≈12
EXH outlet
41.7
39.4
25.7
2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B
20.9
P 1
76.2
7.5
802
Plug-in Unit SQ1000 Series
47
maintenance reasons or planning to mount a
spare valve, etc.
SYJ
11.5 SZ
SUP/EXH block Stations 4
VF
Description/Model 1 2 3 4 5
SSQ1000-PR-3-C8- VP4
Option Single
Valve
Port size Nil Standard VQ
… 1/2
C8 One-touch fittings for ø8 R External pilot specifications
N9 One-touch fittings for ø5/16" S Built-in silencer VQ
SUP/EXH block 4/5
Note) When specifying both options, indicate “RS”.
Option
SSQ1000-PR-3-C8-
∗ Specify the spacer mounting position on the manifold VQC
specification sheet. 1/2
For standard type manifolds, the SUP/EXH VQC
block is mounted on the D side. D side Valve Valve Valve SUP/EXH block U side 4/5
It is added to the manifold to increase 3(R) 3(R)
SUP/EXH capacity. 1(P) 1(P) VQZ
∗ The number of SUP/EXH blocks that can
be added is limited to two sets, one U side SQ
between manifold stations and another on
the U side of the manifold due to the length VFS
of the internal lead wire.
∗ SUP/EXH blocks are not included in the
number of manifold stations. VFR
D side 18 (A)4 2(B) (A)4 2(B) (A)4 2(B) (P)1 3(R)
VQ7
Individual SUP spacer
Side ported
SSQ1000-P-3- C6 Description/Model
Stations 1 2 3 4 5
Port size
Single
Side C6 One-touch fittings for ø6
Valve
ported U side
N7 One-touch fittings for ø1/4"
…
Top L6 One-touch fittings for ø6
ported LN7 One-touch fittings for ø1/4" Individual SUP spacer
Option
Valve
Top L6 One-touch fittings for ø6 …
ported LN7 One-touch fittings for ø1/4"
Individual EXH spacer
This is used to exhaust an individual valve when the
Option
Top ported SSQ1000-R-3-C6 L6
exhaust from a valve interferes with other stations in
D side EXH shut off position:
the circuit (used for one station).
Both sides of the station which is to be individually Please specify.
exhausted are shut off. (Refer to application example.)
∗ Specify the spacer mounting position and EXH
passage shut off positions on the manifold EXH block plate EXH block plate
specification sheet. Up to two shut off positions (Ordering not required) (Ordering not required)
can be specified per unit.
Individual
(Two pieces of EXH block plate that shut off the D side Valve EXH spacer Valve Valve U side
exhaust are included with the individual EXH
3(R) X X 3(R)
spacer, therefore, it is not necessary to order 1(P)
Manifold block 1(P)
them separately.)
∗ Electrical wiring is also connected to the For top ported
≈9
manifold station with the individual EXH spacer.
∗ By changing the fitting shown in the drawing
and the block plates, the spacer’s specification
can be changed later (from the individual EXH
spacer to the individual SUP spacer).
∗ The number of spacers is not limited when
ordered with the manifold. However, when
60
SSQ1000-PR1-3- C6 Stations 1 2 3 4 5
Port size Description/Model
Side C6 One-touch fittings for ø6 Single
U side
Valve
∗ Do not install any back pressure check valve on (A)4 2(B) (P)13(R) (A)4 2(B) (A)4 2(B)
47
SSQ1000-B-P
When supplying two different pressures, high D side 5
and low, to one manifold, this is used
between stations with different pressures.
SV
Also, it is used with an individual SUP spacer
to shut off the air supply. SYJ
∗ Specify the station position on the manifold
ø6.5
ø5
specification sheet. SUP
passage
SZ
<Block indication label>
When using block plates for SUP passage,
U side VF
indication label for confirmation of the
blocking position from outside is attached.
(One label of each)
O-ring VP4
∗ When ordering a block plate for SUP R R VQ
incorporated with the manifold, a block
indication label is attached to the manifold. P P 1/2
VQ
SUP passage blocked SUP/EXH passage blocked 4/5
VQC
1/2
EXH block plate P
R
VQC
4/5
SSQ1000-B-R
8.5 5
When the exhaust from a valve interferes D side
VQZ
with other stations in the circuit, this is used
between stations to separate exhausts. Also, SQ
it is used with an individual EXH spacer to
shut off the exhaust of individual valves.
VFS
6.2
5
∗ Specify the station position on the manifold
specification sheet.
∗ Be sure to discharge the exhaust inside the EXH
passage
VFR
EXH passage from the R port of the SUP/EXH
block, etc. so that the exhaust pressure is not U side
sealed. O-ring
VQ7
<Block indication label>
When using block plates for EXH passage,
indication label for confirmation of the
blocking position from outside is attached.
(One label of each) R R
∗ When ordering a block plate for EXH P P
incorporated with the manifold, a block
indication label is attached to the manifold.
EXH passage blocked SUP/EXH passage blocked
Caution
1. The manifold installed type back pressure check valve assembly is assembly parts with a check valve structure. However, since slight
air leakage against the back pressure is allowed due to its structure, adverse effects of the back pressure due to increase in exhaust
resistance cannot be prevented if the manifold exhaust port and other exhaust ports are put together for piping or if the piping diameter
is narrowed. As a result, this may cause the actuator and air operated equipment to malfunction. So, be careful not to restrict the
exhaust air. If the exhaust resistance becomes large, select a built-in valve type with rubber seal.
2. When a back pressure check valve is mounted, the effective area of the valve will decrease by about 20%.
3. Since 4 port specification valves (5 (R1) and 3 (R2) are common) are used, back pressure cannot be prevented with dual 3 port valves.
805
SQ1000 Series
40.5
manifolds with only a few stations, therefore,
remove the silencer cover to install it.
∗ When ordering this option incorporated
with a manifold, suffix “-N” to the end of the
manifold part number. Silencer cover
øD
SUP/EXH ports.
Purchasing order is available in units of 10
pieces.
Port plug
VVQZ100-CP
9
The plug is used to block the cylinder port when
using a 5-port valve as a 3-port valve. A port
∗ Add “A” or “B” at the end of the valve part
number when ordering with valves.
ø10
Example) SQ1131-51-C6-A (N.O. specifications)
4 (A) port plug
Example) SQ1131-51-C6-B (N.C. specifications) O-ring
2 (B) port plug
Example) SQ1131-51-C6-B-M B port
(B port plug with manifold block)
EXH outlet
806
Plug-in Unit SQ1000 Series
Onetouch fitting)
SQ1131-51- C0 ················ 2 sets
∗SSQ1000-52A- C8 ··········· 1 set
N9
Specifications
Effective area mm2 Noise reduction
Series Model (Cv factor) (dB)
SQ1000 AN15-C08 20 (1.1) 30
807 A
SQ2000 Series
55.5
It is used by attaching on the manifold block
for being prepared for removing a valve for
B
maintenance reasons or planning to mount a
spare valve, etc.
17.5
Valve
Port size Nil Standard
…
C8 One-touch fittings for ø8 R External pilot specifications
C10 One-touch fittings for ø10 S Built-in silencer
SUP/EXH block
N9 One-touch fittings for ø5/16"
Option
SSQ2000-PR-3-C10-
N11 One-touch fittings for ø3/8"
Note) When specifying both options,
indicate “RS”.
∗ Specify the spacer mounting position SUP/EXH
U side D side Valve Valve Valve block U side
on the manifold specification sheet.
3(R) 3(R)
For standard type manifolds, the SUP/EXH 1(P) 1(P)
block is mounted on the D side.
It is added to the manifold to increase SUP/EXH
capacity.
∗ The number of SUP/EXH blocks that can be
added is limited to two sets, one between manifold D side
stations and another on the U side of the manifold
due to the length of the internal lead wire. 20
∗ SUP/EXH blocks are not included in the number of
manifold stations. (A)4 2(B) (A)4 2(B) (A)4 2(B) (P)1 3(R)
Side C8
ported N9 One-touch fittings for ø5/16"
…
Top L8 One-touch fittings for ø8
ported LN9 One-touch fittings for ø5/16" Individual SUP spacer
Option
This is used as a supply port for different Top ported D side SSQ2000-P-3-C8 L8
pressures when using different pressures in the SUP shut off position:
same manifold (for one station). Please specify.
Both sides of the station which is used with
supply pressure from the individual SUP spacer
are shut off. (Refer to application example.) SUP block plate SUP block plate
∗ Specify the spacer mounting position and (Ordering not required) (Ordering not required)
SUP passage shut off positions on the
Individual SUP
manifold specification sheet. Up to two shut D side Valve spacer Valve Valve U side
off positions can be specified per unit. 3(R) 3(R)
(Two pieces of SUP block plate that shut off 1(P) X X 1(P)
the supply pressure are included with the
Manifold block
individual SUP spacer, therefore, it is not
necessary to order them separately.)
≈10
spacer).
∗ The number of spacers is not limited when
25.7
Valve
ported N9 One-touch fittings for ø5/16"
Top
ported
L8 One-touch fittings for ø8 … SYJ
LN9 One-touch fittings for ø5/16"
This is used to exhaust an individual valve Individual EXH spacer
SZ
Option
when the exhaust from a valve interferes with Top ported D side SSQ2000-R-3-C8 L8
other stations in the circuit (used for one EXH shut off position:
station).
Both sides of the station which is to be
Please specify. VF
individually exhausted are shut off. (Refer to
application example.)
∗ Specify the spacer mounting position and EXH block plate EXH block plate VP4
EXH passage shut off positions on the (Ordering not required) (Ordering not required)
manifold specification sheet. Up to two shut
VQ
off positions can be specified per unit. Individual EXH 1/2
D side Valve spacer Valve Valve U side
(Four pieces of EXH block plate that shut off VQ
the exhaust are included with the individual 3(R) X X 3(R)
1(P) 1(P) 4/5
EXH spacer, therefore, it is not necessary to X X
order them separately.)
Manifold block
VQC
∗ Electrical wiring is also connected to the 1/2
≈10
manifold station with the individual EXH
spacer. For top ported VQC
∗ By changing the fitting shown in the drawing 4/5
and the block plates, the spacer’s
specification can be changed later (from the
individual EXH spacer to the individual SUP VQZ
spacer).
SQ
62.1
∗ The number of spacers is not limited when (A)4 2(B) 3(R) (A)4 2(B) (A)4 2(B)
55.4
the manifold station, on which the spacer is to (A)4 2(B) (P)1 3(R) (A)4 2(B) (A)4 2(B)
25.7
6.2
5
specification sheet.
4.6
specification sheet.
∗ Be sure to discharge the exhaust inside the
EXH passage from the R port of the SUP/EXH
block, etc. so that the exhaust pressure is not
sealed. EXH passage U side
O-ring
<Block indication label>
When using block plates for EXH passage,
indication label for confirmation of the R R
blocking position from outside is attached. P P
(One label of each) R R
∗ When ordering a block plate for EXH
incorporated with the manifold, a block
EXH passage blocked SUP/EXH passage blocked
indication label is attached to the manifold.
53
manifolds with only a few stations, therefore, SZ
remove the silencer cover to install it.
∗ When ordering this option incorporated
with a manifold, suffix “-N” to the end of the VF
manifold part number.
Silencer cover VP4
VQ
1/2
Blanking plug (For One-touch fitting)
L Dimensions VQ
4/5
04 Applicable fittings
Model A L D VQC
KQ2P- 06
08
A size ød
1/2
4 KQ2P-04 16 32 6
10 6 KQ2P-06 18 35 8 VQC
8 KQ2P-08 20.5 39 10 4/5
It is inserted into an unused cylinder port and 10 KQ2P-10 22 43 12
SUP/EXH ports. VQZ
ød
øD
ø14
Example) SQ2131-51-C8-A (N.O. specifications)
4 (A) port plug
Example) SQ2131-51-C8-B (N.C. specifications)
EXH outlet
811
SQ2000 Series
One-touch fitting)
24.7
57.5
This is inserted into the centralized type
size ø10
36.5
EXH port (One-touch fitting).
ø10
Specifications
Effective area (mm2) Noise reduction
Series Model
(Cv factor) (dB)
SQ2000 AN20-C10 30 (1.6) 30
A 812
Plug-in Unit SQ1000/2000 Series
In the internal wiring of F kit, P kit, T kit and S kit, double wiring (connected to SOL. A and SOL. B) is adopted for each station regardless of the valve
and option types. Mixed single and double wiring is available as an option.
SV
1. How to Order
Indicate option symbol “-K” in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification SYJ
sheet. Also, specify wiring for spare connectors.
(Up to two spare connectors are included depending on the remaining number of connector pins. When the wiring for the spare connectors is not specified, SZ
they will be wired according to “Spare Connector Wiring” on page 816.)
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
26 25 1/2
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B
1 24 23 COM. COM. VQC
14 2 22 21 4/5
15 3
20 19 20 19
16
17
4
18 17 18 17
VQZ
5
18 6 16 15 16 15
19 7 14 13 14 13
SQ
20 8
21 12 11 12 11
22
9
10 9 10 9
VFS
10
23 11 8 7 8 7
24 12 6 5 6 5 VFR
25 13 4 3 4 3
COM. 2 1 2 1 VQ7
3. Maximum stations
The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double
solenoid type. Determine the number of stations so that the total number of solenoids is no more than the maximum points in the table below.
813 A
SQ1000/2000 Series
The standard DIN rail provided is approximately 30 mm longer than the overall length of the manifold with a specified number of stations.
The following options are also available.
DIN rail length longer than the standard type (for stations to be added later, etc.)
In the manifold part number, specify “-D” for the manifold mounting symbol and add the number of required stations after the symbol.
Example) SS5Q13-08FD0-D09BNK
AXT100-DR- n Note) For “n”, enter a number from the “No.” line in the table below.
For L dimension, refer to the dimensions of each kit.
L
1.25 P=12.5 5.25 7.5
35
25
5.5
No. 11 12 13 14 15 16 17 18 19 20
L dimension 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5
No. 21 22 23 24 25 26 27 28 29 30
L dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5
No. 31 32 33 34 35 36 37 38 39 40
L dimension 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5
SQ1000 SQ2000
Mounting hole (For M4) Mounting hole (For M5) U side end plate assembly
D side end plate assembly
814
Plug-in Unit SQ1000/2000 Series
The following valve part numbers are for negative common specifications. Manifold part numbers are the same as the standard except L kit.
Also, negative common specifications are not available for the S kit. SV
How to order negative common valves (Example) SYJ
SQ1130 N -51-C6
SZ
Negative common specifications
VF
How to order negative common manifold (Example)
SS5Q13 - 08 LD1 N - D N VP4
Stations Option VQ
1/2
Kit type DIN rail mounting type VQ
4/5
Negative common specifications
VQC
1/2
VQC
Inch-size One-touch Fittings 4/5
VQZ
For One-touch fittings in inch sizes, use the following part numbers. Also, the color of the release button is orange.
SQ
How to order valves (Example)
SQ1130- 51 - N7 VFS
Port location Cylinder port
Nil Side ported Symbol N1 N3 N7 N9 VFR
L Top ported Applicable tubing O.D. (Inch) ø1/8" ø5/32" ø1/4" ø5/16"
4(A), SQ1000 — VQ7
2(B) port SQ2000 —
815
SQ1000/2000 Series
What to order
• Valves with manifold block (refer to pages 767 and 787) or the manifold blocks (Refer to page 817).
e Open the junction cover and attach the spare connector. Match the station position of the added station and the spare
connector station number.
r Press on the end plate to eliminate any space between the manifold blocks and tighten the clamp screw.
(Proper tightening torque: 0.8 to 1.0 N·m)
Note 1) Order a manifold block with lead wire for the L kit because a spare connector is not included with the kit. (Refer to page 817.)
Note 2) Do not let the lead wires get caught between manifolds, or when closing the junction cover.
D side
w Manifold block
Station number
q
5
U side
e Spare connector
q
Junction cover
r
816
Plug-in Unit SQ1000/2000 Series
VQZ
SSQ1000 1A 3 FS 03 SSQ2000 1A 3 FS 03 SQ
817 A
SQ1000/2000 Series
3. Connection Method (Refer to page 816 regarding the steps for adding stations to a manifold block.)
Connect the round terminal of the red lead wire to the common terminal inside the junction cover.
Terminal screw
Tightening torque 0.25 to 0.35 N·m
F, P kit T, S kit
Housing Screw
(Tightening torque 0.14 to 0.17 N·m)
(F kit) (P kit) Connector
Terminal block
Connector
Manual lever
Spring
Protrusion Hook
Remove the stopper
and pull out Housing
Lead wire cover the connector.
Hook
A 818
Plug-in Unit SQ1000/2000 Series
(3) Connect the black and white lead wire pins to the positions shown below in accordance with each kit.
Caution 1. After inserting the pin, confirm that the pin hook is locked by lightly pulling the lead wire.
2. Do not pull the lead wire forcefully when connecting. Also, take care that lead wires do not get caught between SV
manifolds or when closing the junction cover.
SYJ
Wiring (F Kit: D-sub Connector Kit)
SZ
Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the D-sub connector, and for
station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows. VF
Connector terminal no.
Lead wire assembly
VP4
Station 1 Black, SOL. A 1
14 Station 2 Black, SOL. A VQ
Station 3 Black, SOL. A 2 1/2
15 Station 3 White, SOL. B Terminal Lead wire
14
18 SOL.A
2 Black 1/2
20
6 3 stations
19 SOL.B VQC
21
10
7 15 White
22
4/5
11
Black 20 SOL.A
23
13 12
8 3 Black
24
4 stations
21 SOL.B VQZ
25
9 16 White
22 SOL.A
COM (Red) 4 Black
White 10
23 5 stations SOL.B SQ
Hook 11 17 White
24 SOL.A
Manifold Specifications’ Example 12 6 stations 5 Black VFS
25
Stations 1
2 3 4 5 6 13
COM.
Single wiring
COM.
13 Red VFR
Double wiring ∗ The drawing above shows connections based on the
manifold specifications’ example in the table to the left. VQ7
819
SQ1000/2000 Series
A B color no.
SOL.A Black Station 1: 1
1 2 3 4 1 station COM. Red Station 1: 2
White Double wiring
SOL.A Black Station 1: 3
SOL.B Black Red White Unused 2 stations COM. Red Station 1: 4
Red
Stations SOL.A Black Station 2: 1
COM. 3 stations
for all double COM. Red Station 2: 2
Black
SOL.A A B wiring SOL.A Black Station 2: 3
Station 1
1
4 stations COM. Red Station 2: 4
Station 2
2
Station 3 SOL.B White Station 3: 1
3
Station 4
4
SOL.A Black Station 3: 3
Insert to the locking position. Station 5
5
6 Station 6 5 stations COM. Red Station 3: 4
Station 7 SOL.B White Station 4: 1
7
Station 8
8
Stations 1 2 3 4 5 6
Single wiring
Double wiring Connector no.
A 820
Plug-in Unit SQ1000/2000 Series
821
SQ1000 Series
Construction: SQ1000 Series Plug-in Type Main Parts and Pilot Valve Assembly
Metal seal type Rubber seal type
Single: SQ1130 Single: SQ1131
r e q w r e q w
SQ1130 SQ1131
(A) 4 2 (B) (A) 4 2 (B)
SQ1230D SQ1231D
(A) 4 2 (B) (A) 4 2 (B)
3 3
3 position: SQ14 30 3 position: SQ14 31
5 5
r e q w e r e q w e
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2)
(P) (P) (P) (P) (P) (P)
A
Dual 3 port valve: SQ1 B 31
C
Component Parts
No. Description Material r e w q w e
1 Body Zinc die-casted
Spool/Sleeve Stainless steel (Metal seal)
2
Spool Aluminum (Rubber seal)
3 Piston Resin
4 Pilot valve assembly —
SQ1A31 SQ1B31
4 (A) 2 (B) 4 (A) 2 (B)
SQ1C31
4 (A) 2 (B)
1 (P) 3 (R)
A 822
Plug-in Unit SQ2000 Series
Construction: SQ2000 Series Plug-in Type Main Parts and Pilot Valve Assembly
Metal seal type Rubber seal type
Single: SQ2130 Single: SQ2131
r e q w
r e q w
SV
SQ2130 SQ2131
(A) 4 2 (B) (A) 4 2 (B)
SYJ
(R1) 5 1 3 (R2)
(P)
(R1) 5 1 3 (R2)
(P) SZ
VF
Double: SQ2230D Double: SQ2231D
VP4
r e q w r e q w
VQ
SQ2230D SQ2231D 1/2
(A) 4 2 (B) (A) 4 2 (B) VQ
4/5
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2) VQC
(P) (P)
1/2
VQC
3 3 4/5
3 position:SQ2 4 30 3 position: SQ2 4 31
5 5
VQZ
r e q w r e q w
SQ
VFS
VFR
SQ2330 SQ2430 SQ2530 SQ2331 SQ2431 SQ2531 VQ7
(A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B)
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2)
(P) (P) (P) (P) (P) (P)
A
Dual 3 port valve: SQ2 B 31
C
Component Parts
r e q w
No. Description Material
1 Body Aluminum die-casted
Spool/Sleeve Stainless steel (Metal seal)
2
Spool Aluminum (Rubber seal)
3 Piston Resin
4 Pilot valve assembly —
SQ2A31 SQ2B31
4 (A) 2 (B) 4 (A) 2 (B)
SQ2C31
4 (A) 2 (B)
823 A
SQ1000 Series
(F, P, L, S kit)
D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly
y
F kit
!3
q
P kit (26P/20P) u
P kit
!2
o !3
w
i
!1
!0
L kit
t
S kit
A 824
Plug-in Unit SQ1000 Series
…
Manifold mounting Wiring specifications 24 For 24 stations
Nil DIN rail mounting type Electrical entry 0 Without lead wire
E Direct mounting type F F kit q S Single wiring
Note 1) The maximum number of SYJ
stations will be different
P P kit (26P) W Double wiring
PC P kit (20P)
w
Note) L kit: Nil
depending on the wiring
specifications.
SZ
Nil L kit e Note 2) L kit: Nil
S S kit r VF
<t SI unit> <o Element>
VP4
Manifold No. Description SSQ1000 SE
SDQ kit EX140-SDN1 DeviceNet ® (16 output points) Note) Part number for a 10 piece set of element. VQ
SDR1 kit EX140-SCS1 OMRON Corp.: CompoBus/S (16 output points) For replacement procedures, refer to page 881. 1/2
SDR2 kit EX140-SCS2 OMRON Corp.: CompoBus/S (8 output points) VQ
SDV kit EX140-SMJ1 CC-LINK (16 output points) <!0 Port plug>
4/5
VVQZ2000 CP VQC
<y U side end plate assembly> 1/2
(For F, P, S kit) <!1 Fitting assembly> VQC
(For P, R port) 4/5
SSQ1000 2A 3 1
(For L kit) VVQ1000 51A C8 VQZ
SSQ1000 2A 3 2 Port size
Manifold mounting C6 One-touch fitting for ø6 SQ
Nil DIN rail mounting type C8 One-touch fitting for ø8
E Direct mounting type N7 One-touch fitting for ø1/4" VFS
N9 One-touch fitting for ø5/16"
Note) Purchasing order is available VFR
<u SUP/EXH block assembly> in units of 10 pieces.
825 D
SQ2000 Series
(F, P, T, L, S kit)
D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly
u
F kit
q !4
i
P kit (26P/20P)
P kit
o
!0
w !4 !3
e
!2
!1
T kit
L kit
y
S kit
A 826
Plug-in Unit SQ2000 Series
…
Manifold mounting Wiring specifications
Electrical entry 16 For 16 stations
Nil DIN rail mounting type 0 Without lead wire
E Direct mounting type F F kit q S Single wiring Note 1) The maximum number of SYJ
P P kit (26P) stations will be different
w W Double wiring
depending on the wiring
PC P kit (20P) Note) L kit: Nil specifications. SZ
T T kit e Note 2) L kit: Nil
Nil L kit r
S S kit y
VF
<!0 Element>
<y SI unit> SSQ2000 SE VP4
Manifold No. Description Note) Part number for a 10 piece set of element. VQ
SDQ kit EX140-SDN1 DeviceNet ® (16 output points) For replacement procedures, refer to page 881. 1/2
SDR1 kit EX140-SCS1 OMRON Corp.: CompoBus/S (16 output points) VQ
SDR2 kit EX140-SCS2 OMRON Corp.: CompoBus/S (8 output points) <!1 Port plug> 4/5
SDV kit EX140-SMJ1 CC-LINK (16 output points)
VVQZ3000 CP VQC
1/2
<u U side end plate assembly> <!2 Fitting assembly> VQC
(For F, P, T, S kit) 4/5
(For P, R port)
SSQ2000 2A 3 1 VVQ2000 51A C8 VQZ
(For L kit)
SSQ2000 2A 3 2 Port size
C8 One-touch fitting for ø8 SQ
Manifold mounting
C10 One-touch fitting for ø10
Nil DIN rail mounting type
N9 One-touch fitting for ø5/16" VFS
E Direct mounting type
N11 One-touch fitting for ø3/8"
Note) Purchasing order is available VFR
<i SUP/EXH block assembly> in units of 10 pieces.
16 Station 16
L0 L kit: Lead wire kit
Lead wire length 0.6 m Note 1) “F0”: Nil
L kit: Lead wire kit
L1 Lead wire length 1.5 m
L kit: Lead wire kit
L2 Lead wire length 3 m
827 E
Plug Lead Unit
SS5Q14 08 FD2 D
Stations CE/UKCA-compliant
01 1 station Nil —
… … Q CE/UKCA-compliant
24 Note) 24 stations
1(P), 3(R) port size
Note) The maximum number of
Nil 1(P), 3(R) port, One-touch fittings for ø8
stations depends on the
type of electrical entries. 00T 1(P), 3(R) port, One-touch fittings for ø5/16"
Refer to “Electrical entry”
for details.
Manifold mounting
D DIN rail mounting type
Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside .)
The number of stations that may be displayed is longer than the manifold number of
Option
stations. Example: -D09
Nil None Note 2) When “-B” is selected, a back pressure check valve is included in all stations of the
02 to 24 (1) DIN rail length specified manifold. If the back pressure check valve is used only for the station that need it, then
specify the station location in the manifold specification. (“-B” is not necessary)
B (2)(3) Back pressure check valve
Note 3) Since 4 port specification valves (5 (R1) and 3 (R2) are common) are used, back pressure
K (4) Special wiring specifications (Except double wiring) cannot be prevented with dual 3 port valves.
N With name plate (Side ported only) Note 4) Specify “-K” for wiring specification for cases below. (Except C kit)
- All single wiring
R External pilot specifications
- Single and double mixed wiring.
S Built-in silencer, direct exhaust Specify the wiring specification in the manifold specification so that the number of
solenoids is the maximum number of solenoids or less. (Standard wiring specification is
double wiring)
Note 5) For specifying two or more options, enter them alphabetically. Example: -BKN
∗ Refer to pages 856 to 860 and 866 to 868 for manifold option parts.
Electrical entry
Lead wire Max. number of
Kit type connector Cable specifications Station solenoids for special
location wiring specifications (2)
Connector kit
Note 1) Separately order the 20P type cable assembly for the P kit.
Note 2) Specify the wiring so that the maximum number of solenoids is not exceeded. (The number of solenoids are counted as: 1 for single solenoids and
2 for type 3P and 4P double solenoids.)
∗ Refer to page 877 for manifold spare parts.
b 828
Plug Lead Unit SQ1000 Series
SQ1 1 4 0 5 L 1 C6
Seal CE/UKCA-compliant
0 Metal seal Nil —
1 Rubber seal Q CE/UKCA-compliant SV
With/Without manifold block
Type of actuation
Nil M MB Note) SYJ
2 position single
With manifold block,
Without manifold With manifold
1
(A)4 2(B)
block block
built-in back pressure SZ
check valve
(R1)5 1 3(R2)
(P) VF
2 position double
(Double solenoid) (1) VP4
(A)4 2(B) (A)4 2(B)
2 VQ
(R1)5 1 3(R2) (R1)5 1 3(R2)
1/2
• When ordering
(P) (P)
Metal seal Rubber seal with manifolds VQ
For adding stations 4/5
• When only valves
3 position closed center are required.
(A)4 2(B)
VQC
Note) Since 4 port specification valves (5 (R1) and 3 (R2) are 1/2
3 common) are used, back pressure cannot be prevented with
(R1)5 1 3(R2) dual 3 port valves.
VQC
(P) 4/5
3 position exhaust center Port plug mounting port
(A)4 2(B) VQZ
Nil None
4
(R1)5 1 3(R2)
A Port 4(A)
SQ
(P) B Port 2(B)
3 position pressure center
Cylinder port VFS
(A)4 2(B)
Symbol Port size Port location
5
C3 One-touch fitting for ø3.2 VFR
(R1)5 1 3(R2)
(P) C4 One-touch fitting for ø4 Side
4 position dual 3 port valve C6 One-touch fitting for ø6 ported VQ7
4(A) 2(B) M5 M5 thread
A (2) L3 One-touch fitting for ø3.2
(1)
L4 One-touch fitting for ø4 Top
1(P) 3(R) L6 One-touch fitting for ø6 ported
L5 M5 thread
4 position dual 3 port valve
4(A) 2(B) Note 1) Can be changed to side ported configuration.
Note 2) Refer to page 868 for the inch-size One-touch fittings.
B (2)
Manual override
1(P) 3(R) Nil B
4 position dual 3 port valve Non-locking push type Locking type
4(A) 2(B) (Tool required) (Tool required)
C (2)
1(P) 3(R)
Note 1) For double solenoid specification, the
function symbol below is “D”.
Note 2) Only rubber seal types are
applicable. Electrical entry
Function
L LO
Symbol Specifications Rated voltage Plug connector type Plug connector type
Nil Standard type (0.4 W) 5 24 VDC With 300 mm lead wire without connector
B (4) Quick response type (0.95 W) 6 12 VDC
D (1) 2 position double (Double solenoid specifications) Note) Light/surge voltage
High pressure type (1 MPa, 0.95 W) suppressor is built-in.
K (4)
[Applicable to metal seal only]
N Negative common
R (2) External pilot specifications For F, P, J
Note 1) “D” is specified for 2 position double. kit manifolds Note)
Note 2) Except dual 3 port valves. Note) Indicate “LO” when ordering centralized wiring type
Note 3) When two or more symbols are specified, indicate them alphabetically. manifolds, F, P, and J kits, since the lead wire will be
Note 4) Function combination of “B” and “K” is not possible. attached to the manifold side.
829 a
SQ1000 Series
Manifold Options
Blanking plate Individual SUP/EXH spacer Name plate (-N) External pilot specifications (-R)
SSQ1000-10A-4 P.856 SSQ1000-PR1-4-C6
L6 SSQ1000-N3-n P.859 P.860
External pilot port
P.857
SUP/EXH block SUP block plate Blanking plug Dual flow fitting
SSQ1000-PR-4-C8 (-S) SSQ1000-B-P P.858 KQ2P-23 / 04 / 06/08 SSQ1000-52A- C8
N9 P.860
P.856 P.859
D side
U side
D side
U side
Individual EXH spacer Back pressure check valve (-B) Built-in silencer, Special wiring specifications (-K)
SSQ1000-R-4-C6 L6 P.857 SSQ1000-BP P.858 direct exhaust (-S) P.859 P.866
D-sub connector Terminal no.
SOL.A
1 station 1 (–)
SOL.A
2 stations 14 (–)
SOL.A
1
3 stations 2 (–)
14 SOL.A
2 4 stations 15 (–)
15 SOL.A
3 3 (–)
16
4 5 stations SOL.B
17
5
16 (–)
18 SOL.A
6 4 (–)
19 6 stations
7 SOL.B
20 17 (–)
8 SOL.A
21 5 (–)
9
22
10
7 stations SOL.B
23 18 (–)
11 SOL.A
24 6 (–)
12 8 stations
25 SOL.B
13 19 (–)
COM.
13 (+)
830
Plug Lead Unit SQ1000 Series
6 e
5 id
4 Us SZ
3
2
1
s VF
tion
Sta
VP4
VQ
D-sub connector cable 1/2
AXT100-DS25-030 VQ
4/5
Cylinder port fitting VQC
C6: One-touch fitting for ø6 1/2
ide VQC
Ds 4/5
Manifold base (9 stations)
SS5Q14-09FD2-D
F kit
VQZ
(D-sub connector kit)
SQ
VFS
SS5Q14-09FD2-D ········ 1 set (F kit 9-station manifold base)
∗ SQ1140-5LO1-C6 ····· 4 sets (2 position single) VFR
∗ SQ1240D-5LO1-C6 ··· 4 sets (2 position double)
∗ SSQ1000-10A-4 ········ 1 set (Blanking plate) VQ7
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part numbers in order starting from the first station on the D side.
When entry of part numbers becomes complicated, indicate on the manifold specification sheet.
831
SQ1000 Series
Valve Specifications
Model
Flow rate characteristics (1) Response time (ms) (2)
Type of Weight
Series
actuation
Seal Model 1→4/2 (P→A/B) 4→5 (A→R1) Standard Quick response (g)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv (0.4 W) (0.95 W)
Metal seal SQ1140 0.62 0.10 0.14 0.63 0.11 0.14 26 or less 12 or less 80
Single
2 position
Rubber seal SQ1141 0.79 0.20 0.19 0.80 0.20 0.19 24 or less 15 or less 80
Metal seal SQ1240D 0.62 0.10 0.14 0.63 0.11 0.14 13 or less 10 or less 95
Double
Rubber seal SQ1241D 0.79 0.20 0.19 0.80 0.20 0.19 20 or less 15 or less 95
Closed Metal seal SQ1340 0.58 0.12 0.14 0.63 0.11 0.14 44 or less 29 or less 100
center Rubber seal SQ1341 0.64 0.20 0.15 0.58 0.26 0.16 39 or less 25 or less 100
SQ1000
3 position
Exhaust Metal seal SQ1440 0.58 0.12 0.14 0.60 0.14 0.14 44 or less 29 or less 100
center Rubber seal SQ1441 0.64 0.20 0.15 0.80 0.20 0.19 39 or less 25 or less 100
Pressure Metal seal SQ1540 0.62 0.12 0.14 0.63 0.14 0.14 44 or less 29 or less 100
center Rubber seal SQ1541 0.79 0.21 0.19 0.59 0.20 0.14 39 or less 25 or less 100
Dual
4 position
A
3 port Rubber seal SQ1B 41 0.59 0.28 0.15 0.59 0.28 0.15 27 or less 14 or less 95
C
valve
Note 1) Values for the cylinder port size of C6, CYL → Values of EXH. Flow rate characteristics of 2 → 3 (B → R2) delines about 30% of 4 → 5 (A → R1).
Note 2) Based on JIS B 8419:2010. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the
pressure and air quality.)
Specifications
Valve construction Metal seal Rubber seal
Fluid Air
Maximum operating pressure 0.7 MPa (High pressure type (3) : 1.0 MPa)
Valve specifications
Symbol
Allowable voltage fluctuation ±10% of rated voltage
Solenoid
2 position single
(A)4 2(B) Coil insulation type Equivalent to class B
Power consumption 24 VDC 0.4 W DC (17 mA), 0.95 W DC (40 mA) (4)
(R1)5 1 3(R2) (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) (4)
(P)
Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test
2 position double (Double solenoid)
was performed at both energized and de-energized states in the axial
(A)4 2(B) (A)4 2(B) direction and at the right angles to the main valve and armature. (Values at
the initial period)
(R1)5 1 3(R2) (R1)5 1 3(R2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
(P) (P) direction and at the right angles to the main valve and armature in both
Metal seal Rubber seal energized and deenergized states every once for each condition.
Note 3) Metal seal type only.
3 position closed center 3 position pressure center 4 position dual 3 port valve (B) Note 4) Value for quick response,
4(A) 2(B) high pressure type.
(A)4 2(B) (A)4 2(B)
4 position dual 3 port valve (A) 4 position dual 3 port valve (C)
3 position exhaust center
4(A) 2(B) 4(A) 2(B)
(A)4 2(B)
(R1)5 1 3(R2)
(P)
1(P) 3(R) 1(P) 3(R)
A 832
Plug Lead Unit SQ1000 Series
Manifold Specifications
Porting specifications
Addition
Port size (1) Applicable 5-station
Applicable per
Base model solenoid Type of connection weight (4)
4(A), 2(B) stations (3) station (4)
valve (g)
1(P), 3(R) Port (g)
location Port size SV
C3 (For ø3.2) F kit: D-sub connector 1 to 12 stations 420 20
C8 Side C4 (For ø4) SYJ
(For ø8) C6 (For ø6) 26P 1 to 12 stations
M5 (M5 thread)
SQ140
P kit: Flat ribbon cable
20P 1 to 9 stations
420 20 SZ
SS5Q14-- Option
SQ141
Built-in
silencer,
L3 (For ø3.2) VF
L4 (For ø4) 1 to 24 stations
direct exhaust Top (2) L6 (For ø6) C kit: Connector kit 460 35
L5 (M5 thread) VP4
Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 868. VQ
Note 2) Can be changed to side ported configuration. 1/2
Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 866 for details. VQ
Note 4) Except valves. For valve weight, refer to page 832. 4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
4(A), 2(B) port
VFR
3(R) port
1(P) port VQ7
25P 26P / 20P (P kit)
F kit P kit
C kit
833 A
SQ1000 Series
Cable assembly
ons
015 tati
AXT100-DS25- 030 ····· s
050 3 ·····
The D-sub connector cable assemblies can be ordered with 12
ide
manifolds. Refer to “How to Order Manifold.” Ds
D-sub Connector ∗ Valves are numbered from the D side.
Cable Assembly Electrical Wiring Specifications
Terminal No.
Cable
Terminal Lead wire Dot D-sub connector
0.3 mm2 x 25 cores
O.D. ø1.4 number color marking
1 Black None As the standard electrical wiring specifications,
≈ø10 double wiring (connected to SOL. A and SOL.
2 Brown None 14
1
2 B) is adopted for the internal wiring of each
Seal 3 Red None 15
16
3
station for 12 stations or less, regardless of
4
015 (Length indication) 4 Orange None 17
5 valve and option types.
18
5 Yellow None 19
6
Mixed single and double wiring is available as
L
7
Molded cover 6 Pink None 20
21
8 an option.
9
2 x M2.6 x 0.45 7 Blue None 22
10
For details, refer to page 866.
23
44
834
Plug Lead Unit SQ1000 Series
Indicator light
L3
5 L2 SV
37 L1
29.9 41.6 P=11.5 23.9 SYJ
25 27
M5: External pilot port Manual SZ
override
VF
11
VP4
98.6 (Double, Dual 3 port valve)
VQ
1/2
94.1 (Single)
107.6 (3 position)
VQ
(94.1)
4/5
5.5
VQC
67.9
35
1/2
47.1
VQC
34.3
4/5
28.1
12.7
VQZ
SQ
≈10
≈9
≈9
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø8
4 4 4 4 4 4 4 4
R 3
60
(49.4)
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
27
7.5
835
SQ1000 Series
Simplification and labor savings for wiring work can be Manifold Specifications
achieved by using a MIL type for the electrical connection. Porting specifications Maximum
Using the connector for flat ribbon cable (26P, 20P)
Series Port Port size number of
conforming to MIL standard permits the use of connectors put stations
location 1(P), 3(R) 4(A), 2(B)
on the market and gives a wide interchangeability.
Top or side receptacle position can be selected in accordance 12 stations
SQ1000 Side, Top C8 C3, C4, C6, M5
(24 as a semi-standard)
with the available mounting space.
ide
Flat Ribbon Cable (26 Pins, 20 Pins) Us
Cable assembly s
tion
1 sta
AXT100-FC 20 ····
26 - 2 ·····
3 3·
e 12
id
Type 26P flat ribbon cable connector assemblies can be Ds
ordered with manifolds. Refer to "How to Order manifold".
∗ Valves are numbered from the D side.
Electrical Wiring Specifications
6 Terminal no. 28AWG
Red Flat ribbon cable connector
26 25
30 (20P)
37.5(26P)
25
16 15
14 13 For details, refer to page 866.
12 11
(15.6) 10 9
8 7
L 6 5 Connector terminal no.
4 3
2 1
Triangle mark indicator position
Flat Ribbon Cable Connector Assembly
Cable Assembly part no. <26P> <20P>
length (L) 26P 20P Terminal no. Polarity Terminal no. Polarity
1.5 m AXT100-FC26-1 AXT100-FC20-1 SOL.a SOL.a
1 (−) (+) 1 (−) (+)
3m AXT100-FC26-2 AXT100-FC20-2 1 station SOL.b 1 station SOL.b
2 (−) (+) 2 (−) (+)
5m AXT100-FC26-3 AXT100-FC20-3 SOL.a SOL.a
3 (−) (+) 3 (−) (+)
2 stations SOL.b 2 stations SOL.b
∗ For other commercial connectors, use a 26 pins or 20 pins with 4 (−) (+) 4 (−) (+)
SOL.a SOL.a
strain relief conforming to MIL-C-83503. 5 (−) (+) 5 (−) (+)
3 stations SOL.b 3 stations SOL.b
∗ Cannot be used for movable wiring. 6 (−) (+) 6 (−) (+)
∗ Lengths other than the above are also available. Please contact SOL.a SOL.a (+)
7 (−) (+) 7 (−)
SMC for details. 4 stations SOL.b 4 stations SOL.b
8 (−) (+) 8 (−) (+)
SOL.a (+) SOL.a (−) (+)
9 (−) 9
5 stations SOL.b 5 stations SOL.b
Connector manufacturers’ example 10 (−) (+) 10 (−) (+)
SOL.a (+) SOL.a (−) (+)
11 (−) 11
• HIROSE ELECTRIC CO., LTD. 6 stations SOL.b 6 stations SOL.b
12 (−) (+) 12 (−) (+)
• 3M Japan Limited SOL.a SOL.a
13 (−) (+) 13 (−) (+)
• Fujitsu Limited 7 stations SOL.b 7 stations SOL.b
• Japan Aviation Electronics Industry, Limited 14 (−) (+) 14 (−) (+)
SOL.a (+) SOL.a (−) (+)
• J.S.T. Mfg. Co., Ltd. 15 (−) 15
8 stations SOL.b (+)
8 stations SOL.b (−) (+)
• Oki Electric Cable Co,. Ltd. 16 (−) 16
SOL.a (−) (+) SOL.a (−) (+)
17 17
9 stations SOL.b 9 stations SOL.b (−) (+)
18 (−) (+) 18
SOL.a 19 (−) (+) COM.
10 stations SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+)
11 stations SOL.b Positive Negative
22 (−) (+)
common common
SOL.a 23 (−) (+) specifications specifications
12 stations SOL.b (+)
24 (−)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common
specifications specifications
836
Plug Lead Unit SQ1000 Series
Indicator light
L3 SV
5 L2
45.4 L1 SYJ
37 41.6 P=11.5 23.9
M5: External pilot port 25 27 Manual SZ
override
VF
11
VP4
98.6 (Double, Dual 3 port valve)
VQ
1/2
94.1 (Single)
107.6 (3 position)
VQ
(94.1)
4/5
5.5
VQC
67.9
35
1/2
47.1
34.3
VQC
4/5
28.1
12.7
VQZ
≈10
≈9
[3(R), 1(P) port]
Applicable tubing O.D.: ø8 For top ported
4 4 4 4 4 4 4 4
R 3
60
(49.4)
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
27
7.5
837
A 838
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
839 A
SQ1000 Series
C Kit (Connector)
Standard with lead wires connected to each valve individually.
Manifold Specifications
Porting specifications Maximum
Series Port Port size number of
location 1(P), 3(R) 4(A), 2(B) stations
ons
tati
····· s
3 ·····
e 12
id
Ds
∗ Valves are numbered from the D side.
Wiring Specifications: Positive Common Specifications Wiring Specifications: Negative Common Specifications (Semi-standard)
Since lead wires are connected to the valves as shown below, Since lead wires are connected to the valves as shown below,
connect each wire to the power supply. connect each wire to the power supply.
Plug connector lead wire length Plug connector lead wire length
The lead wire length of the valves with lead wire is 300 mm. When The lead wire length of the valves with lead wire is 300 mm. When
ordering a lead wire length of 600 mm or longer, list the part numbers ordering a lead wire length of 600 mm or longer, list the part numbers
for the valve without connector and the connector assembly. for the valve without connector and the connector assembly.
Example) For lead wire length of 1000 mm: SQ1140-5LO1-C6····3 pcs. Example) For lead wire length of 1000 mm: SQ1140-5LO1-C6····3 pcs.
AXT661-14AL-10····3 pcs. AXT661-14ANL-10····3 pcs.
Connector Assembly Part No. Connector Assembly Part No.
Lead wire length Single solenoid Double solenoid Lead wire length Single solenoid Double solenoid
Socket only (3 pcs.) AXT661-12AL Socket only (3 pcs.) AXT661-12AL
300 mm AXT661-14AL AXT661-13AL 300 mm AXT661-14ANL AXT661-13ANL
600 mm AXT661-14AL-6 AXT661-13AL-6 600 mm AXT661-14ANL-6 AXT661-13ANL-6
1000 mm AXT661-14AL-10 AXT661-13AL-10 1000 mm AXT661-14ANL-10 AXT661-13ANL-10
2000 mm AXT661-14AL-20 AXT661-13AL-20 2000 mm AXT661-14ANL-20 AXT661-13ANL-20
3000 mm AXT661-14AL-30 AXT661-13AL-30 3000 mm AXT661-14ANL-30 AXT661-13ANL-30
Note) When using the negative common specifications, use valves
for negative common.
840
Plug Lead Unit SQ1000 Series
L3
Lead wire length:
5 L2
SV
L1 Indicator light SYJ
41.6 P=11.5 23.9
≈300
27 SZ
Manual override
M5: External pilot port
VF
9.6
VP4
98.6 (Double, Dual 3 port valve)
VQ
1/2
94.1 (Single)
107.6 (3 position)
VQ
4/5
(94.1)
5.5
VQC
67.9
1/2
35
47.1
VQC
34.3
4/5
28.1
12.7
VQZ
SQ
≈10
≈9
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø8
4 4 4 4 4 4 4 4
R 3
60
(49.4)
P 1 2 2 2 2 2 2 2 2
37
29.6
26
13.1
27
[4(A), 2(B) port]
41.6 P=11.5
Applicable tubing O.D.: ø3.2
: ø4
: ø6
Thread size: M5
841
Plug Lead Unit
SS5Q24 08 FD2 D
Stations CE/UKCA-compliant
01 1 station Nil —
… … Q CE/UKCA-compliant
16 16 stations
Refer to “Electrical entry” for details. 1(P), 3(R) port size
Nil 1(P), 3(R) port, One-touch fittings for ø10
00T 1(P), 3(R) port, One-touch fittings for ø3/8"
Manifold mounting
D DIN rail mounting type
E Note) Direct mounting type
Note) Type E is only available with a C kit.
Refer to page 867 for details.
Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside .)
Option The number of stations that may be displayed is longer than the manifold number of
Nil None stations. Example: -D09
02 to 16 (1) DIN rail length specified Note 2) When “-B” is selected, a back pressure check valve is included in all stations of the
manifold. If the back pressure check valve is used only for the station that need it, then
B Back pressure check valve specify the station location in the manifold specification. (“-B” is not necessary)
K (3) Special wiring specifications (Except double wiring) Note 3) Specify “-K” for wiring specification for cases below. (Except C kit)
N With name plate (Side ported only) - All single wiring
- Single and double mixed wiring.
R External pilot specifications Specify the wiring specification in the manifold specification so that the number of
S Built-in silencer, direct exhaust solenoids is the maximum number of solenoids or less. (Standard wiring specification is
double wiring)
Note 4) For specifying two or more options, enter them alphabetically. Example: -BKN
∗ Refer to pages 861 to 868 for manifold option parts.
Electrical entry
Lead wire Max. number Max. number of
Stations of solenoids for solenoids for
Kit type connector Cable specifications special wiring special wiring
location specifications specifications (2)
F kit U side FD0 D-sub connector (25P) kit, without cable
FD1 D-sub connector (25P) kit, with 1.5 m cable 1 to 12 stations
D side 16 stations 24
D side FD2 D-sub connector (25P) kit, with 3.0 m cable (Double wiring)
D-sub
Connector kit FD3 D-sub connector (25P) kit, with 5.0 m cable
P kit PD0 Flat ribbon cable (26P) kit, without cable
PD1 Flat ribbon cable (26P) kit, with 1.5 m cable 1 to 12 stations
24
PD2 D side (1) Flat ribbon cable (26P) kit, with 3.0 m cable (Double wiring) 16 stations
26P
PD3 Flat ribbon cable (26P) kit, with 5.0 m cable
Flat ribbon cable connector kit 20P PDC Flat ribbon cable (20P) kit, without cable 1 to 9 stations (Double wiring) 18
C kit
Connector kit
Note 1) Separately order the 20P type cable assembly for the P kit.
Note 2) Specify the number of the solenoid so that the maximum station number is not exceeded.(The number of solenoids are counted as: 1 for single
solenoids and 2 for type 3P and 4P double solenoids.)
∗ Refer to page 877 for manifold spare parts.
b 842
Plug Lead Unit SQ2000 Series
SQ2 1 4 0 5 L 1 C6
CE/UKCA-compliant
Seal
0 Metal seal
Nil — SV
Q CE/UKCA-compliant
1 Rubber seal With/Without manifold block
Nil M MB
SYJ
Type of actuation
With manifold block,
2 position single Without manifold With manifold
built-in back pressure SZ
(A)4 2(B) block block
check valve
1
VF
(R1)5 1 3(R2)
(P)
2 position double VP4
(Double solenoid) (1)
(A)4 2(B) (A)4 2(B)
VQ
1/2
2
(R1)5 1 3(R2) (R1)51 3(R2) • When ordering
VQ
(P) (P) with manifolds
4/5
Metal seal Rubber seal For adding stations
• When only valves VQC
3 position closed center are required. 1/2
(A)4 2(B)
VQC
3
4/5
(R1)51 3(R2) Port plug mounting port
(P) Nil None VQZ
3 position exhaust center A Port 4(A)
(A)4 2(B)
4
B Port 2(B) SQ
(R1)5 1 3(R2) Cylinder port
(P) VFS
Symbol Port size Port location
3 position pressure center
C4 One-touch fitting for ø4
(A)4 2(B) Side VFR
5 C6 One-touch fitting for ø6
ported
C8 One-touch fitting for ø8
(R1)5 1 3(R2)
(P)
VQ7
L4 One-touch fitting for ø4
4 position dual 3 port valve Top
L6 One-touch fitting for ø6
4(A) 2(B) ported(1)
L8 One-touch fitting for ø8
A (2) Note 1) Can be changed to side ported configuration.
Note 2) Refer to page 868 for the inch-size One-touch fittings.
5(R1) 1(P) 3(R2)
4 position dual 3 port valve
Manual override
4(A) 2(B) Nil B D
Slide locking type
B (2) Non-locking push type Locking type
(Manual type)
(Tool required) (Tool required)
∗ Only side ported type applicable
5(R1) 1(P) 3(R2)
4 position dual 3 port valve
4(A) 2(B)
C (2)
Manifold Options
Blanking plate Individual SUP/EXH spacer Name plate (-N) External pilot specifications (-R)
SSQ2000-10A-4 P.861 SSQ2000-PR1-4-C8
L8 SSQ2000-N3-n P.864 P.865
External pilot port
P.862
SUP/EXH block SUP block plate Blanking plug Dual flow fitting
SSQ2000-PR-3-C10(-S) SSQ1000-B-R P.863 KQ2P-04 /06 /08/10 P.864 SSQ2000-52A- C10
N11 P.865
P.861
D side
U side
D side
U side
Individual EXH spacer Back pressure check valve (-B) Built-in silencer, Special wiring specifications (-K)
SSQ2000-R-4-C8 L8 P.862 SSQ2000-BP P.863 direct exhaust (-S) P.864 P.866
D-sub connector Terminal no.
SOL.A
1 station 1 (–)
SOL.A
2 stations 14 (–)
SOL.A
1 3 stations 2 (–)
14 SOL.A
15
2 4 stations 15 (–)
3 SOL.A
16 3 (–)
17
4 5 stations SOL.B
5 16 (–)
18 SOL.A
6 4 (–)
19
7 6 stations SOL.B
20 17 (–)
8
21 SOL.A
9 5 (–)
22
10 7 stations SOL.B
23 18 (–)
11 SOL.A
24 6 (–)
12
25 8 stations SOL.B
13 19 (–)
COM.
13 (+)
844
Plug Lead Unit SQ2000 Series
2 position double (Double solenoid) (24 VDC) 3 position exhaust center (24 VDC)
SQ2240D-5LO1-C8 (3 sets) SQ2340-5LO1-C8 (1 set)
2 position single (24 VDC) Blanking plate SV
SQ2140-5LO1-C8 (3 sets) 8 SSQ2000-10A-4 (1 set)
6
7
SYJ
5 ide
4 Us
2
3 SZ
1
3m
tion
s VF
Sta
VP4
VQ
1/2
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part numbers in order starting from the first station on the D side.
When entry of part numbers becomes complicated, indicate on the manifold specification sheet.
845
SQ2000 Series
Valve Specifications
Model
Flow rate characteristics (1) Response time (ms) (2)
Type of Weight
Series
actuation
Seal Model 1→4/2 (P→A/B) 4/2→5/3 (A/B→R1/R2) Standard Quick response (g)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv (0.4 W) (0.95 W)
Metal seal SQ2140 2.2 0.17 0.51 2.4 0.14 0.57 35 or less 20 or less 145
Single
2 position
Rubber seal SQ2141 2.3 0.17 0.51 3.1 0.18 0.71 31 or less 24 or less 140
Metal seal SQ2240D 2.2 0.17 0.51 2.4 0.14 0.57 20 or less 15 or less 160
Double
Rubber seal SQ2241D 2.3 0.17 0.51 3.1 0.18 0.71 26 or less 20 or less 155
Closed Metal seal SQ2340 1.9 0.17 0.46 2.1 0.15 0.47 56 or less 37 or less 180
center Rubber seal SQ2341 1.9 0.17 0.46 1.8 0.29 0.45 44 or less 34 or less 175
SQ2000
3 position
Exhaust Metal seal SQ2440 1.9 0.17 0.46 2.4 0.14 0.55 56 or less 37 or less 180
center Rubber seal SQ2441 1.9 0.17 0.46 3.1 0.14 0.58 44 or less 34 or less 175
Pressure Metal seal SQ2540 2.3 0.17 0.51 2.1 0.18 0.47 56 or less 37 or less 180
center Rubber seal SQ2541 2.5 0.17 0.56 1.8 0.30 0.47 44 or less 34 or less 175
Dual
4 position
A
3 port Rubber seal SQ2 B41 1.5 0.17 0.40 1.5 0.17 0.40 34 or less 19 or less 155
C
valve
Note 1) Values for the top ported cylinder port size of C8, CYL → Values of EXH. The side ported type will be about 10% less.
Note 2) Based on JIS B 8419:2010. (Values with a supply pressure of 0.5 MPa and light/surge voltage suppressor. Values fluctuate depending on the
pressure and air quality.)
Specifications
Valve construction Metal seal Rubber seal
Fluid Air
Maximum operating pressure 0.7 MPa
Valve specifications
2 position single
(A)4 2(B) Coil insulation type Equivalent to class B
Power consumption 24 VDC 0.4 W DC (17 mA), 0.95 W DC (40 mA) (3)
(R1)5 1 3(R2) (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) (3)
(P)
Note 1) Use dry air to prevent condensation when operating at low temperatures.
2 position double (Double solenoid) Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
(A)4 2(B) (A)4 2(B)
the right angles to the main valve and armature. (Values at the initial period)
Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and
(R1)5 1 3(R2) (R1)5 1 3(R2)
(P) (P) deenergized states every once for each condition.
Metal seal Rubber seal Note 3) Value for quick response type.
3 position closed center 3 position pressure center 4 position dual 3 port valve (B)
4(A) 2(B)
(A)4 2(B) (A)4 2(B)
4 position dual 3 port valve (A) 4 position dual 3 port valve (C)
3 position exhaust center
4(A) 2(B) 4(A) 2(B)
(A)4 2(B)
(R1)5 1 3(R2)
(P)
5(R1) 1(P) 3(R2) 5(R1) 1(P) 3(R2)
A 846
Plug Lead Unit SQ2000 Series
Manifold Specifications
Porting specifications
Addition
Port size (1) Applicable 5-station
Applicable per
Base model solenoid Type of connection weight (4)
4(A), 2(B) stations (3) station (4)
1(P), 3(R) valve (g)
Port (g)
location Port size SV
F kit: D-sub connector 1 to 12 stations 580 35
C10 Side
C4 (For ø4)
C6 (For ø6)
SYJ
(For ø10) C8 (For ø8) 26P 1 to 12 stations
SQ240
P kit: Flat ribbon cable
20P 1 to 9 stations
580 35 SZ
SS5Q24-- Option SQ241
Built-in
silencer, L4 (For ø4) VF
direct exhaust Top (2) L6 (For ø6) C kit: Connector kit 1 to 16 stations 620 50
L8 (For ø8) VP4
Note 1) One-touch fittings in inch sizes are also available. For details, refer to page 868.
VQ
1/2
Note 2) Can be changed to side ported configuration.
Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 866 for details. VQ
Note 4) Except valves. For valve weight, refer to page 846. 4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
4(A), 2(B) port VQ7
3(R) port
1(P) port
25P 26P / 20P (P kit)
F kit P kit
C kit
847 A
SQ2000 Series
Cable assembly
s
015 tion
AXT100-DS25- 030 sta
050 ········
3 ··
The D-sub connector cable assemblies can be ordered with 12
manifolds. Refer to “How to Order Manifold.” ide
Ds
D-sub Connector ∗ Valves are numbered from the D side.
Cable Assembly Electrical Wiring Specifications
Terminal No.
Cable
Terminal Lead wire Dot D-sub connector
0.3 mm2 x 25 cores
number color marking
O.D. ø1.4 As the standard electrical wiring specifications,
≈ø10 1 Black None
double wiring (connected to SOL. A and SOL.
2 Brown None 14
1
2 B) is adopted for the internal wiring of each
3 Red None 15
3
Seal (length indication) 16 station for 12 stations or less, regardless of
015 4 Orange None 17
4
5 valve and option types. Mixed single and
18
5 Yellow None 19
6
double wiring is available as an option.
L
7
Molded cover 6 Pink None 20
21
8 For details, refer to page 866.
2 x M2.6 x 0.45 7 Blue None 22
9
10
23
44
848
Plug Lead Unit SQ2000 Series
L3
SV
5 L2
58.1
33.4 37 L1 SYJ
18.2 29.5 48.7 P=17.5 28.8
M5: External pilot port Indicator light
(Mounting hole
dimension) Release for switching
25 30
1
SZ
connector direction Manual
VF
11
override
131.5 (Single, Double, Dual 3 port valve)
VP4
5.4
10.4
VQ
2 x M4 1/2
5.5
147 (3 position)
DIN rail VQ
(131.5)
clamp screw
122.3
4/5
35
A 4
VQC
1/2
69.8
55.9
VQC
53.6
B 2
4/5
37.6
18.5
VQZ
≈12
SQ
≈12
EXH outlet
VFS
Applicable connector: D-sub connector (25P)
(Conforming to MIL-C-24308) D side Stations 1 2 3 4 5 6 7 8 n U side VFR
VQ7
≈10
One-touch fitting
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø10
R 3
(58.1)
62.1
41.7
39.4
25.7
20.9
P 1
30
7.5
849
SQ2000 Series
ide
Flat Ribbon Cable (26 Pins, 20 Pins) Us
Cable assembly s
tion
1 sta
AXT100-FC 20
26 - 2 ········
3 3 ··
ide 12
Type 26P flat ribbon cable connector assemblies can be Ds
ordered with manifolds. Refer to "How to Order manifold".
∗ Valves are numbered from the D side.
Electrical Wiring Specifications
6 Terminal no. 28AWG
Red Flat ribbon cable connector
26 25
30 (20P)
37.5(26P)
25
16 15
14 13 For details, refer to page 866.
12 11
(15.6) 10 9
8 7
L 6 5 Connector terminal no.
4 3
2 1
Triangle mark indicator position
Flat Ribbon Cable Connector Assembly
Cable Assembly part no. <26P> <20P>
length (L) 26P 20P Terminal no. Polarity Terminal no. Polarity
1.5 m AXT100-FC26-1 AXT100-FC20-1 SOL.a SOL.a
1 (−) (+) 1 (−) (+)
3m AXT100-FC26-2 AXT100-FC20-2 1 station SOL.b 1 station SOL.b
2 (−) (+) 2 (−) (+)
5m AXT100-FC26-3 AXT100-FC20-3 SOL.a SOL.a
3 (−) (+) 3 (−) (+)
2 stations SOL.b 2 stations SOL.b
∗ For other commercial connectors, use a 26 pins or 20 pins with 4 (−) (+) 4 (−) (+)
SOL.a SOL.a
strain relief conforming to MIL-C-83503. 5 (−) (+) 5 (−) (+)
3 stations SOL.b 3 stations SOL.b
∗ Cannot be used for movable wiring. 6 (−) (+) 6 (−) (+)
∗ Lengths other than the above are also available. Please contact SOL.a SOL.a (+)
7 (−) (+) 7 (−)
SMC for details. 4 stations SOL.b 4 stations SOL.b
8 (−) (+) 8 (−) (+)
SOL.a (+) SOL.a (−) (+)
9 (−) 9
5 stations SOL.b 5 stations SOL.b
Connector manufacturers’ example 10 (−) (+) 10 (−) (+)
SOL.a (+) SOL.a (−) (+)
11 (−) 11
• HIROSE ELECTRIC CO., LTD. 6 stations SOL.b 6 stations SOL.b
12 (−) (+) 12 (−) (+)
• 3M Japan Limited SOL.a SOL.a
13 (−) (+) 13 (−) (+)
• Fujitsu Limited 7 stations SOL.b 7 stations SOL.b
• Japan Aviation Electronics Industry, Limited 14 (−) (+) 14 (−) (+)
SOL.a (+) SOL.a (−) (+)
• J.S.T. Mfg. Co., Ltd. 15 (−) 15
8 stations SOL.b (+)
8 stations SOL.b (−) (+)
• Oki Electric Cable Co,. Ltd. 16 (−) 16
SOL.a (−) (+) SOL.a (−) (+)
17 17
9 stations SOL.b 9 stations SOL.b (−) (+)
18 (−) (+) 18
SOL.a 19 (−) (+) COM.
10 stations SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+)
11 stations SOL.b Positive Negative
22 (−) (+)
common common
SOL.a 23 (−) (+) specifications specifications
12 stations SOL.b (+)
24 (−)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common
specifications specifications
850
Plug Lead Unit SQ2000 Series
L3
58.1 5 L2
33.4 37 L1 SV
18.2 25 48.8 P=17.5 28.8 Indicator light
(Mounting hole
M5: External pilot port 30
1
SYJ
dimension) Release for switching
connector direction Manual
SZ
11
override
≈12 131.5 (Single, Double, Dual 3 port valve)
VF
5.4
10.4
2 x M4 VP4
5.5
147 (3 position)
DIN rail
VQ
(131.5)
clamp screw
1/2
122.3
35
A 4
VQ
4/5
69.8
55.9
VQC
53.6
B 2
1/2
37.6
18.5
VQC
4/5
VQZ
≈12
≈10
One-touch fitting
[3(R), 1(P) port] For top ported
VFR
Applicable tubing O.D.: ø10
R 3 VQ7
(58.1)
62.1
41.7
39.4
25.7
20.9
P 1
30
7.5
851
A 852
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
853 A
SQ2000 Series
C Kit (Connector)
Standard with lead wires connected to each valve individually.
Manifold Specifications
Porting specifications Maximum
Series Port Port size number of
location 1(P), 3(R) 4(A), 2(B) stations
ide
Us
ns
atio
····· st
3 ·····
ide 12
Ds
∗ Valves are numbered from the D side.
Wiring Specifications: Positive Common Specifications Wiring Specifications: Negative Common Specifications (Semi-standard)
Since lead wires are connected to the valves as shown below, Since lead wires are connected to the valves as shown below,
connect each wire to the power supply. connect each wire to the power supply.
Plug connector lead wire length Plug connector lead wire length
The lead wire length of the valves with lead wire is 300 mm. When The lead wire length of the valves with lead wire is 300 mm. When
ordering a lead wire length of 600 mm or longer, list the part numbers ordering a lead wire length of 600 mm or longer, list the part numbers
for the valve without connector and the connector assembly. for the valve without connector and the connector assembly.
Example) For lead wire length of 1000 mm: SQ2140-5LO1-C6····3 pcs. Example) For lead wire length of 1000 mm: SQ2140N-5LO1-C6···3 pcs.
AXT661-14AL-10····3 pcs. AXT661-14ANL-10···3 pcs.
Connector Assembly Part No. Connector Assembly Part No.
Lead wire length Single solenoid Double solenoid Lead wire length Single solenoid Double solenoid
Socket only (3 pcs.) AXT661-12AL Socket only (3 pcs.) AXT661-12AL
300 mm AXT661-14AL AXT661-13AL 300 mm AXT661-14ANL AXT661-13ANL
600 mm AXT661-14AL-6 AXT661-13AL-6 600 mm AXT661-14ANL-6 AXT661-13ANL-6
1000 mm AXT661-14AL-10 AXT661-13AL-10 1000 mm AXT661-14ANL-10 AXT661-13ANL-10
2000 mm AXT661-14AL-20 AXT661-13AL-20 2000 mm AXT661-14ANL-20 AXT661-13ANL-20
3000 mm AXT661-14AL-30 AXT661-13AL-30 3000 mm AXT661-14ANL-30 AXT661-13ANL-30
Note) When using the negative common specifications, use
valves for negative common.
854
Plug Lead Unit SQ2000 Series
SV
L4
5 L3 SYJ
L2
58.1 7 L1
33.4 41.8 P=17.5 28.8
SZ
Lead wire length: ≈300
18.2 23 Indicator light
(Mounting hole
dimension)
1 VF
M5: External pilot port
VP4
8.7
Manual
override
VQ
131.5 (Single, Double, Dual 3 port valve)
1/2
5.4
10.4
VQ
4/5
2 x M4
VQC
147 (3 position)
DIN rail
1/2
(131.5)
clamp screw
122.3
5.5
35
VQC
A 4
4/5
VQZ
69.8
55.9
53.6
B 2
37.6
SQ
18.5
VFS
≈12
≈12
VFR
EXH outlet
VQ7
D side Stations 1 2 3 4 5 6 7 8 n U side
≈10
One-touch fitting
[3(R), 1(P) port] For top ported
Applicable tubing O.D.: ø10
R 3
(58.1)
62.1
41.7
39.4
25.7
20.9
P 1
30
7.5
855
SQ1000 Series
47
maintenance reasons or planning to mount a
spare valve, etc.
∗ Electrical wiring is connected to the manifold
station with the blanking plate.
11.5
Valve
Port size Nil Standard
C8 One-touch fittings for ø8 R External pilot specifications
N9 One-touch fittings for ø5/16" S Built-in silencer
SUP/EXH block
Option
Note) When specifying both options, indicate “-RS”. SSQ1000-PR-4-C8-
∗ Specify the spacer mounting position on the manifold
specification sheet.
SSQ1000-P-4- C6
Stations 1 2 3 4 5
Description/Model
Port size
U side
Side C6 One-touch fittings for ø6 Single
Valve
SSQ1000-P-4-C6L6
when using different pressures in the same
manifold (for one station). Both sides of the station SUP shut off position:
which is used with supply pressure from the Please specify.
individual SUP spacer are shut off. (Refer to
application example.)
∗ Specify the spacer mounting position and SUP SUP block plate SUP block plate
passage shut off positions on the manifold (Ordering not required) (Ordering not required)
specification sheet. Up to two shut off positions
can be specified per unit. Individual SUP
Manifold block D side Valve spacer Valve Valve U side
(Two pieces of SUP block plate that shut off the
supply pressure are included with the individual 3(R) 3(R)
≈9
changed later (from the individual SUP spacer to (A)4 2(B) 1(P) (A)4 2(B) (A)4 2(B)
the individual EXH spacer).
26
Valve
ported N7 One-touch fittings for ø1/4"
Top
ported
L6 One-touch fittings for ø6 SYJ
LN7 One-touch fittings for ø1/4"
Top ported Individual EXH spacer
This is used to exhaust an individual valve when D side
SZ
Option
SSQ1000-R-4-C6 L6
the exhaust from a valve interferes with other
stations in the circuit (used for one station). Both EXH shut off position:
sides of the station which is to be individually Please specify. VF
exhausted are shut off. (Refer to application
example.)
∗ Specify the spacer mounting position and EXH EXH block plate EXH block plate VP4
passage shut off positions on the manifold
(Ordering not required) (Ordering not required)
specification sheet. Up to two shut off positions VQ
can be specified per unit. Individual EXH 1/2
(Two pieces of EXH block plate that shut off the D side Valve spacer Valve Valve U side
exhaust are included with the individual EXH Manifold block VQ
3(R) X X 3(R)
spacer, therefore, it is not necessary to order 1(P) 1(P) 4/5
For top ported
≈9
them separately.)
∗ No electrical wiring is connected to the manifold VQC
station with the individual EXH spacer. 1/2
When the wiring needs to be connected to the
stations with the individual EXH spacer mounted, VQC
specify it on the manifold specification sheet. 4/5
∗ By changing the fitting shown in the drawing and
the block plates, the spacer’s specification can be VQZ
changed later (from the individual EXH spacer to
60
the individual SUP spacer). (A)4 2(B) 3(R) (A)4 2(B) (A)4 2(B)
SQ
47
and another on the U side, due to the length of the lead wire.
∗ Model no. with manifold block:
47
SSQ1000-PR1-4- C6
37
ø6.5
ø5
specification sheet.
SUP
<Block indication label> passage
When using block plates for SUP passage, U side
indication label for confirmation of the
blocking position from outside is attached. O-ring
(One label of each)
∗ When ordering a block plate for SUP R R
incorporated with the manifold, a block
indication label is attached to the manifold. P P
6.2
5
specification sheet.
∗ Be sure to discharge the exhaust inside the
EXH passage from the R port of the SUP/EXH EXH
block, etc. so that the exhaust pressure is not passage
sealed. U side
<Block indication label> O-ring
When using block plates for EXH passage,
indication label for confirmation of the
blocking position from outside is attached. R R
(One label of each)
∗ When ordering a block plate for EXH P P
incorporated with the manifold, a block
indication label is attached to the manifold. EXH passage blocked SUP/EXH passage blocked
40.5
manifolds with only a few stations, therefore, SZ
remove the silencer cover to install it.
∗ When ordering this option incorporated
with a manifold, suffix “-N” to the end of the VF
manifold part number.
Silencer cover
VP4
VQ
1/2
Blanking plug (For One-touch fitting) L VQ
Dimensions 4/5
23 A Applicable fittings Model A L D VQC
KQ2P- 04
06
size ød
1/2
3.2 KQ2P-23 16 31.5 5
08 4 KQ2P-04 16 32 6 VQC
6 KQ2P-06 18 35 8 4/5
It is inserted into an unused cylinder port and
8 KQ2P-08 20.5 39 10
SUP/EXH ports.
VQZ
ød
øD
ø10
Example) SQ1141-5L1-C6-A (N.O. specifications)
859
SQ1000 Series
26.5
ø13
Specifications
Effective area (mm2) Noise reduction
Series Model
(Cv factor) (dB)
SQ1000 AN15-C08 20 (1.1) 30
A 860
Plug Lead Unit SQ2000 Series
55.5
for being prepared for removing a valve for
maintenance reasons or planning to mount a B
SV
spare valve, etc.
SYJ
∗ Electrical wiring is connected to the manifold
station with the blanking plate. 17.5
SZ
SUP/EXH block Stations 4 VF
Description/Model 1 2 3 4 5
SSQ2000-PR-3-C10-
Single
VP4
Option
Valve
Port size Nil Standard VQ
C8 One-touch fittings for ø8 R External pilot specifications 1/2
C10 One-touch fittings for ø10 S Built-in silencer VQ
SUP/EXH block
N9 One-touch fittings for ø5/16" 4/5
Option
SSQ2000-PR-3-C10-
N11 One-touch fittings for ø3/8"
VQC
Note) When specifying both options, 1/2
indicate “RS”.
∗ Specify the spacer mounting position U side SUP/EXH VQC
on the manifold specification sheet. D side Valve Valve Valve block U side 4/5
For standard type manifolds, the SUP/EXH 3(R) 3(R)
block is mounted on the D side.
1(P) 1(P) VQZ
It is added to the manifold to increase
SUP/EXH capacity. SQ
∗ The number of SUP/EXH blocks that can be
added is limited to two sets, one between
manifold stations and another on the U side of
D side
VFS
20
manifold, due to the length of the lead wire.
∗ SUP/EXH blocks are not included in the VFR
number of manifold stations. (A)4 2(B) (A)4 2(B) (A)4 2(B) (P)1 3(R)
D side SSQ2000-P-4-C8 L8
pressures when using different pressures in the
same manifold (for one station). SUP shut off position:
Both sides of the station which is used with Please specify.
supply pressure from the individual SUP spacer are
shut off. (Refer to application example.)
∗ Specify the spacer mounting position and SUP SUP block plate SUP block plate
passage shut off positions on the manifold (Ordering not required) (Ordering not required)
specification sheet. Up to two shut off positions Individual SUP
can be specified per unit. D side Valve spacer Valve Valve U side
(Two pieces of SUP block plate that shut off the 3(R) 3(R)
supply pressure are included with the individual Manifold block 1(P) X X 1(P)
SUP spacer, therefore, it is not necessary to
order them separately.)
≈10
Valve
ported N9 One-touch fittings for ø5/16"
U side
Top L8 One-touch fittings for ø8
ported LN9 One-touch fittings for ø5/16"
Individual EXH spacer
This is used to exhaust an individual valve when Top ported
Option
D side SSQ2000-R-4-C8 L8
the exhaust from a valve interferes with other
stations in the circuit (used for one station). Both EXH shut off position:
sides of the station which is to be individually Please specify.
exhausted are shut off. (Refer to application
example.)
∗ Specify the spacer mounting position and EXH EXH block plate EXH block plate
passage shut off positions on the manifold (Ordering not required) (Ordering not required)
specification sheet. Up to two shut off positions
can be specified per unit. Individual EXH
(Four pieces of EXH block plate that shut off the D side Valve spacer Valve Valve U side
exhaust are included with the individual EXH 3(R)
3(R) X X
spacer, therefore, it is not necessary to order Manifold block 1(P) 1(P)
them separately.) X X
≈10
∗ No electrical wiring is connected to the manifold For top ported
station with the individual EXH spacer.
When the wiring needs to be connected to the
stations with the individual EXH spacer mounted,
specify it on the manifold specification sheet.
∗ By changing the fitting shown in the drawing and
the block plates, the spacer’s specification can be
changed later (from the individual EXH spacer to
62.1
55.4
the individual SUP spacer) (A)42(B) 3(R) (A)4 2(B) (A)4 2(B)
41.7
∗ Specify the spacer mounting position and SUP and SUP shut off position:
EXH passage shut off positions on the manifold Please specify.
specification sheet. Up to two shut off positions EXH shut off position:
each for SUP and EXH can be specified per unit. Please specify.
[Block plates that shut off the SUP and EXH passages
are included with the individual SUP/EXH spacer,
therefore, it is not necessary to order them separately (2 Block plate Block plate
pcs. of SUP block plate and 4 pcs. of EXH block plate).] (Ordering not required) (Ordering not required)
∗ No electrical wiring is connected to the manifold
SUP.
station with the individual SUP/EXH spacer. Manifold block Individual EXH.
When the wiring needs to be connected to the stations D side Valve spacer Valve Valve U side
with the individual SUP/EXH spacer mounted, specify 3(R) X X 3(R)
For top Individual EXH port 1(P) X X 1(P)
it on the manifold specification sheet.
≈10
One-touch fitting fo ø8 X X
∗ By changing the fitting shown in the drawing and the block ported
plates, the spacer’s specification can be changed later.
∗ The number of spacers is not limited when ordered
with the manifold. However, when adding
individual for F, P, and J kits, it is limited to two
units, one between manifold stations and another
on the U side, due to the length of the lead wire.
62.1
55.4
SSQ2000-PR1-4-C8 L8 -M
25.7
6.2
∗ Specify the station position on the manifold
5
specification sheet.
SZ
<Block indication label>
SUP passage U side
When using block plates for SUP passage,
indication label for confirmation of the
VF
blocking position from outside is attached. O-ring
(One label of each) VP4
∗ When ordering a block plate for SUP R R
incorporated with the manifold, a block P P VQ
indication label is attached to the manifold. R R 1/2
VQ
SUP passage blocked SUP/EXH passage blocked 4/5
VQC
1/2
EXH block plate VQC
4/5
SSQ2000-B-R ≈10
VQZ
When the exhaust from a valve interferes 9.2 5.2
with other stations in the circuit, this is used
between stations to separate exhausts. Also,
SQ
D side
it is used with an individual EXH spacer to
shut off the exhaust of individual valves. VFS
∗ Specify the station position on the manifold
4.6
specification sheet.
∗ Be sure to discharge the exhaust inside the
VFR
EXH passage from the R port of the SUP/EXH U side
block, etc. so that the exhaust pressure is not EXH passage VQ7
sealed. O-ring
<Block indication label>
When using block plates for EXH passage, R R
indication label for confirmation of the
blocking position from outside is attached.
P P
(One label of each)
R R
∗ When ordering a block plate for EXH
incorporated with the manifold, a block EXH passage blocked SUP/EXH passage blocked
indication label is attached to the manifold.
863
SQ2000 Series
53
manifolds with only a few stations, therefore,
remove the silencer cover to install it.
∗ When ordering this option incorporated
with a manifold, suffix “-N” to the end of the
manifold part number.
Silencer cover
SUP/EXH ports.
øD
Port plug
VVQZ2000-CP 9.7
The plug is used to block the cylinder port when
using a 5-port valve as a 3-port valve.
∗ Add “A” or “B” at the end of the valve part
ø14
number when ordering with valves.
A port
Example) SQ2141-5L1-C8-A (N.O. specifications)
864
Plug Lead Unit SQ2000 Series
∗ SSQ2000-52A-C10 N11
··········· 1 set
24.7
Specifications
Effective area (mm2) Noise reduction
Series Model
(Cv factor) (dB)
SQ2000 AN20-C10 30 (1.6) 30
865 A
SQ1000/2000 Series
1. How to order
Indicate option symbol “ -K ” in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification
sheet.
Example) SS5Q14 - 09 FD0 - DKS
Others, option symbols: to be indicated alphabetically.
2. Wiring specifications
Connector terminal numbers are connected from solenoid station 1 on the A side in the order indicated by the arrows without skipping any terminal
numbers.
COM. COM.
26 25
1 24 23 COM. COM.
14 2
15 22 21
3
16 20 19 20 19
4
17 5 18 17 18 17
18 6 16 15 16 15
19 7 14 13 14 13
20 8
21 12 11 12 11
9
22 10 10 9 10 9
23 11 8 7 8 7
24 12 6 5 6 5
25 13 4 3 4 3
COM. 2 1 2 1
3. Maximum stations
The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double
solenoid type. Determine the number of stations so that the total number of solenoids is no more than the maximum points in the table below.
A 866
Plug Lead Unit SQ1000/2000 Series
VQZ
35
25
SQ
5.5
VFS
L Dimension L = 12.5 x n + 10.5
No. 1 2 3 4 5 6 7 8 9 10 VFR
L dimension 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5
No. 11 12 13 14 15 16 17 18 19 20 VQ7
L dimension 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5
No. 21 22 23 24 25 26 27 28 29 30
L dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5
No. 31 32 33 34 35 36 37 38 39 40
L dimension 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5
867
SQ1000/2000 Series
The following valve part numbers are for negative common specifications. Manifold part numbers are the same as standard.
For One-touch fittings in inch sizes, use the following part numbers. Also, the color of the release button is orange.
What to order
• Valves with manifold block (refer to pages 829 and 843) or the manifold blocks shown below. For F kit, P kit, and J kit, also
order the lead wire assemblies in the next section.
SSQ1000 1A 4 SSQ2000 1A 4
Option Option
Nil None Nil None
B Back pressure check valve B Back pressure check valve
R External pilot specifications R External pilot specifications
Note) Enter “-BR” for both options. Note) Enter “-BR” for both options.
868
Plug Lead Unit SQ1000/2000 Series
SQ1000 SV
D-sub connector kit (F kit) SYJ
Stations Symbol (L dimension) Stations Symbol (L dimension)
For single wiring SSQ1000 40A F 205 Station 2 165 Station 14 320
Station 3 175 Station 15 335
SZ
L
Station 4 190 Station 16 350
Station 5 205 Station 17 365 VF
A CB
SQ2000
D-sub connector kit (F kit)
Stations Symbol (L dimension) Stations Symbol (L dimension)
For single wiring SSQ1000 40A F 250 Station 2 190 Station 14 430
L Station 3 210 Station 15 450
Station 4 230 Station 16 470
Station 5 250 Station 17 490
A CB
r
Connector housing
(F kit is shown.)
2. Connection Method
(1) Connecting common wire Connector to be added
Insert the red lead wire (common wire) of the connector to
be added into the adjacent connector as shown in the White (SOL. B)
drawing below. After inserting, lightly pull on the wire to
confirm that the socket is locked.
Black
(SOL. A)
(F kit) (P kit)
Connector
Protrusion
Connector
Stopper Remove the
stopper and pull
out the connector.
Manual lever
Spring
Housing cover
Slot
F, P kit
A 870
Plug Lead Unit SQ1000/2000 Series
(3) Connector connection/Connect the black and white lead wire pins to the positions shown below in accordance with each kit.
Caution 1. After inserting the pin, confirm that the pin hook is locked by lightly pulling the lead wire.
2. Do not pull the lead wire forcefully when connecting. Also, take care that lead wires do not get caught between SV
manifolds or when remounting the housing.
SYJ
Wiring (F Kit: D-sub Connector Kit)
SZ
Procedure) Based on the manifold specifications, station 1 of SOL.A (black wire) will be terminal number 1 of the D-sub connector, and for
station 2 and thereafter, connect black wires, then white wires in the order as shown below by the arrows. VF
Connector terminal no.
Lead wire assembly
VP4
Station 1 Black, SOL. A 1
14 Station 2 Black, SOL. A VQ
Station 3 Black, SOL. A 2 1/2
15 Station 3 White, SOL. B Terminal Lead wire
14
18 SOL.A
2 Black 1/2
20
6 3 stations
19 SOL.B VQC
21
10
7 15 White
22
4/5
11
Black 20 SOL.A
23
13 12
8 3 Black
24
9 16 White
22 SOL.A
COM (Red) 4 Black
White 10
23 5 stations SOL.B SQ
Hook 11 17 White
24 SOL.A
Manifold Specifications’ Example 12 6 stations 5 Black VFS
25
Stations 1
2 3 4 5 6 COM. 13
Single wiring
COM.
13 Red VFR
Double wiring ∗ The drawing above shows connections based on the
manifold specifications' example in the table to the left. VQ7
871
A 872
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
873
SQ1000 Series
Construction: SQ1000 Series Plug Lead Type Main Parts and Pilot Valve Assembly
Metal seal type Rubber seal type
Single: SQ1140 Single: SQ1141
r e q w r e q w
SQ1140 SQ1141
(A) 4 2 (B) (A) 4 2 (B)
SQ1240D SQ1241D
(A) 4 2 (B) (A) 4 2 (B)
3 3
3 position: SQ1 4 40 3 position: SQ14 41
5 5
r e q w e r e q w e
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2)
(P) (P) (P) (P) (P) (P)
A
Dual 3 port valve: SQ1 B 41
C
Component Parts
No. Description Material r e w q w e
1 Body Zinc die-casted
Spool/Sleeve Stainless steel (Metal seal)
2
Spool Aluminum (Rubber seal)
3 Piston Resin
4 Pilot valve assembly —
SQ1A41 SQ1B41
4 (A) 2 (B) 4 (A) 2 (B)
SQ1C41
4 (A) 2 (B)
1 (P) 3 (R)
A 874
Plug Lead Unit SQ2000 Series
Construction: SQ2000 Series Plug Lead Type Main Parts and Pilot Valve Assembly
Metal seal type Rubber seal type
Single: SQ2140 Single: SQ2141
r e q w r e q w
SV
SQ2140 SQ2141
(A) 4 2 (B) (A) 4 2 (B)
SYJ
(R1) 5 1 3 (R2)
(P)
(R1) 5 1 3 (R2)
(P) SZ
VF
Double: SQ2240D Double: SQ2241D VP4
r e q w r e q w VQ
1/2
SQ2240D SQ2241D
(A) 4 2 (B) (A) 4 2 (B)
VQ
4/5
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2)
VQC
(P) (P) 1/2
VQC
4/5
3 3
3 position: SQ2 4 40 3 position: SQ2 4 41 VQZ
5 5
r e q w
r e q w SQ
VFS
VFR
VQ7
SQ2340 SQ2440 SQ2540 SQ2341 SQ2441 SQ2541
(A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B) (A) 4 2 (B)
(R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2) (R1) 5 1 3 (R2)
(P) (P) (P) (P) (P) (P)
A
Dual 3 port valve: SQ2 B 41
C
Component Parts r e q w
No. Description Material
1 Body Aluminum die-casted
Spool/Sleeve Stainless steel (Metal seal)
2
Spool Aluminum (Rubber seal)
3 Piston Resin
4 Pilot valve assembly —
SQ2A41 SQ2B41
4 (A) 2 (B) 4 (A) 2 (B)
SQ2C41
4 (A) 2 (B)
875 A
SQ1000 Series
(F, P, C kit)
Wiring unit assembly D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly
e
!2
F kit
q t
!1
!2
i
u
P kit (26P/20P)
e !0
r
o
P kit
A 876
Plug Lead Unit SQ1000 Series
<q D-sub connector housing assembly> <r D side end plate assembly>
AXT100 40 FL25 S 03 SSQ1000 3A 4
Wiring Stations SV
S Single wiring 01 For 1 station <t U side end plate assembly>
D Double wiring
SSQ1000 2A 4 SYJ
…
24 For 24 stations
<w Flat ribbon cable connector housing assembly> <y SUP/EXH block assembly> SZ
PL26 SSQ1000 PR 4 C8 VF
AXT100 40 S 03
PL20 Port size
Wiring
Stations Note)
C6 One-touch fitting for ø6 VP4
S Single wiring Note)
C8 One-touch fitting for ø8
D Double wiring 01 For 1 station
PL26: 01 to 24 (P kit, 26P) N7 One-touch fitting for ø1/4" VQ
1/2
…
Station 2 165 Station 8 245 Station 14 320 Station 20 400 <i Element>
Station 3 175 Station 9 260 Station 15 335 Station 21 405
Station 4 190 Station 10 280 Station 16 350 Station 22 420 SSQ1000 SE VQ7
Station 5 205 Station 11 290 Station 17 365 Station 23 435 Note) Part number for a 10 piece set of elements. Refer to page 881 for replacement procedures.
Station 6 215 Station 12 300 Station 18 375 Station 24 450
Station 7 230 Station 13 310 Station 19 385 <o Port plug>
(For P kit)
For station 1 SSQ1000 4 1 B P 150 VVQZ2000 CP
Wiring <!0 Fitting assembly>
0 For single (2-wire) (For P, R port)
1 For double (3-wire)
VVQ1000 51A C8
For station 2 to 24 SSQ1000 4 1 A P 200 Port size
Wiring C6 One-touch fitting for ø6
0 For single (2-wire) C8 One-touch fitting for ø8
1 For double (3-wire) N7 One-touch fitting for ø1/4"
Lead wire length N9 One-touch fitting for ø5/16"
Stations L dimension
(mm) Stations L dimension
(mm) Stations L dimension
(mm) Stations L dimension
(mm) Note) Purchasing order is available in units of 10 pieces.
Station 2 160 Station 8 240 Station 14 315 Station 20 395
Station 3 170 Station 9 255 Station 15 330 Station 21 400 <!1 Fitting assembly>
Station 4 185 Station 10 275 Station 16 345 Station 22 415 (For cylinder port)
Station 5 200 Station 11 285 Station 17 360 Station 23 430
Station 6 210 Station 12 295 Station 18 370 Station 24 445 VVQ1000 50A C6
Station 7 225 Station 13 305 Station 19 380 Port size
(For C kit) C3 One-touch fitting for ø3.2
AXT661 1 3 AL C4
C6
One-touch fitting for ø4
One-touch fitting for ø6
Wiring Lead wire length M5 M5 thread
3 For double (3-wire) Symbol L dimension (mm) N1 One-touch fitting for ø1/8"
4 For single (2-wire) Nil 300 N3 One-touch fitting for ø5/32"
6 600 N7 One-touch fitting for ø1/4"
10 1000
Note) Purchasing order is available in units of 10 pieces.
15 1500
20 2000 <!2 Gasket and screw assembly>
25 2500
30 3000 SQ1000 GS
50 5000 Note) Part number for 10 pieces each of gaskets and screws.
877 A
SQ2000 Series
(F, P, C kit)
Wiring unit assembly D side end plate assembly SUP/EXH block assembly Valve and manifold block assembly U side end plate assembly
!2
t
e
y
F kit
i !1
q
!2
!0
r
o
P kit (26P/20P)
e
P kit
A 878
Plug Lead Unit SQ2000 Series
<q D-sub connector housing assembly> <r D side end plate assembly>
AXT100 41 FL25 S 03 SSQ2000 3A 4
Wiring Stations Manifold mounting SV
S Single wiring 01 For 1 station Nil DIN rail mounting type
D Double wiring E Direct mounting type SYJ
…
12 For 12 stations <t U side end plate assembly>
SZ
<w Flat ribbon cable connector housing assembly> SSQ2000 2A 4 1
AXT100 41 PL26 Manifold mounting VF
PL20 S 03 Nil DIN rail mounting type
Wiring <y SUP/EXH block assembly>
E Direct mounting type VP4
Stations Note)
S Single wiring Note)
01 For 1 station VQ
D Double wiring PL26: 01 to 12 (P kit, 26P) SSQ2000 PR 3 C10 1/2
…
Wiring SSQ2000 1A 4 SQ
0 For single (2-wire) Option
190 Station 8
(mm)
310 Station 14
(mm)
430 Station 20
(mm)
879 A
SQ1000/2000 Series
Specific Product Precautions 1
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid
Valve Precautions.
Warning Caution
Use to switch the main valve. Indicator lights are all positioned on one side for both single
solenoid and double solenoid types.
Push Type (Tool Required) For double, 3 position, and 4 position dual 3 port types, 2
Push down on the manual override button with a small screwdriver until it stops. colors are used to indicate the energization of A side or B side.
SQ1000 Indicator light
SQ1000 SQ2000 A: Red
B: Green
Bore ø4 Bore ø4.8 Single solenoid type
Double (double solenoid) type
3 position/Dual 3 port type
Manual override: Orange (A side)
Manual override: Green (B side)
Indicator light
SQ2000 A: Red
B: Green
Single solenoid type
Double (double solenoid) type
3 position/Dual 3 port type
Locking Type (Tool Required) Manual override: Green (B side)
Manual override: Orange (A side)
Push down completely on the manual override button with a
Single Solenoid Type (SQ1000/2000)
small screwdriver. While down, turn clockwise 90° to lock it.
Turn it counterclockwise to release it. Positive common spec. Negative common spec.
Standard, SOL, A SOL, A
High pressure (–) (+)
SQ1000 SQ2000 type Coil Coil
Locked position +COM –COM
Locked position Quick SOL, A SOL, A
response type (–) (+)
Varistor Coil Varistor Coil
q q +COM –COM
Note) With quick response type, approximately -40 V of coil surge voltage is
w w generated when the valve is switched OFF.
Bore ø4 Bore ø4.8 Double Type (SQ1000/2000)
3 Position Type (SQ1000/2000)
4 Position Dual 3 Port Type (SQ1000/2000)
Positive common spec. Negative common spec.
Standard, SOL, A SOL, A
High pressure (–) (+)
type Coil Coil
+COM –COM
Coil Coil
SOL, B SOL, B
(–) (+)
Slide Locking Type (Manual Type) (SQ2000 only) Quick SOL, A SOL, A
response type (–) (+)
Varistor Coil Varistor Coil
The manual override is locked by sliding it all the way to the pilot +COM –COM
valve side (ON side) with a small flat head screwdriver or finger. Varistor Coil Varistor Coil
Slide it to the fitting side (OFF side) to release it. In addition, it SOL, B SOL, B
(–) (+)
can also be used as a push type by using a screwdriver, etc., of
Note) With quick response type, approximately -40 V of coil surge voltage is
ø2 or less. generated when the valve is switched OFF.
Caution Caution
Mounting The cylinder port fittings are a cassette for easy replacement. SV
• Insert the hook of the valve into the bracket on the manifold block, Fittings are secured with a clip that is inserted from the top
side of the valve. Remove the clip with a flat head
then push the valve down into place and tighten the mounting screw.
screwdriver, etc., to replace the fittings. SYJ
• Tighten the screw with the appropriate tightening torque shown below.
To mount a fitting, insert the fitting assembly until it stops and
SQ1000
SQ2000
0.17 to 0.23 N·m
0.25 to 0.35 N·m
reinsert the clip to its designated position. SZ
Applicable tubing O.D. Fitting assembly part no.
• When pushing the valve down, press it on the area near the (mm) SQ1000 SQ2000 VF
manual override. Be careful not to push the solenoid cover. 3.2 V VQ1000-50A-C3 —
Manual override Mounting screw 4 V VQ1000-50A-C4 V VQ1000-51A-C4 VP4
Solenoid cover 6 V VQ1000-50A-C6 V VQ1000-51A-C6
Connector 8 — V VQ1000-51A-C8 VQ
w ∗ Part numbers above are for one fitting; however, order them in 10 piece units. 1/2
Caution VQ
Bracket Use caution that O-rings must be free from scratches and 4/5
q
Hook dust. Otherwise, air leakage may result. VQC
e
Hook 1/2
Bracket
Clip VQC
Removing
4/5
• Loosen the valve mounting screw, lift the valve from the solenoid
cover side and remove it by sliding it in the direction of arrow e. VQZ
If it is difficult to loosen the screw, loosen it while pressing
the valve gently on the area near the manual override. SQ
Fitting assembly
Mounting and Removal of Manifold with DIN Rail VFS
Caution VFR
Removing Manifold from DIN Rail
q Loosen the end plate clamping screws on both sides until Built-in Silencer Replacement Element VQ7
they turn freely. (The screws do not come out.)
w Remove the manifold from the DIN rail by lifting it from the
solenoid cover side.
Caution
q Solenoid cover A filter element is built into the manifold base end plate.
Clamping screw
When the element becomes dirty and clogged, this will cause
trouble such as a drop in the cylinder speed, etc. Therefore,
replace the element regularly.
Element part no.
Element part no.
Type
End plate w SQ1000 SQ2000
Built-in silencer
Clamping bracket hook SSQ1000-SE SSQ2000-SE
direct exhaust (-S)
∗ Part numbers above are for a set of ten elements.
When a manifold contains a large number of stations and it is difficult to remove
To replace an element, Tightening torque 0.5 to 0.7 N·m
all at once, separate the manifold into several sections before removing it.
remove the cover on
Mounting Manifold on DIN Rail the top side of the end
plate and remove the
The procedure is the reverse of that above. After tightening the clamping
old element with a flat Element
screw on one side, push on the opposite end plate so that there are no gaps head screwdriver, etc.
between the manifold blocks and then tighten the other clamping screw.
End plate
(3) Tighten
Trademark
DeviceNet® is a registered trademark of ODVA, Inc.
881 A