Professional Documents
Culture Documents
ZTE Doc 17 Jun 2023
ZTE Doc 17 Jun 2023
and Principle
ZTE University
Content
Traditional macro-Base
Station, ATM architecture,
12TRX cabinet ZTE macro-Base Station, IP ZTE SDR, 36TRX cabinet
architecture, 18TRX cabinet
Future Oriented SDR Technology ——
Ensuring Multi-Mode Network Convergence
SDR L
H
G H+
W
Convergence
Software Define Radio
Solution Designed Refarming
CDMA2000 WCDMA
GSM LTE
TD-SCDMA
BBU BBU
Interface Interface
•Different BP boards
SDR RRU Spectrum
Refarming Capable
Multi‐band Supported Common
Components Shared
SDR Based Series Base Stations Family
Outdoor Micro Multi‐Mode Supported
ZXSDR BS8906/8906E GSM/UMTS/HSPA
HSPA+/LTE
Multi‐Band Supported
Radio Unit
Indoor Macro G/U900M, G/U1800M
ZXSDR BS8800 U/L2100M, U/L2600M
Baseband Unit
Long term TCO Saving
RSU40 RSU40
B8200 50% HPA Technology
RSU60 RSU60
Outdoor Macro RSU82 RSU82 Smart Carrier On/Off
ZXSDR BS8900A 3 Sectors in 1 RRU
Based on SDR hardware platform, all IP and multiple carriers capable
All base stations share same components, higher integration and less spares
SDR Base Station Key Features
Baseband Unit and Radio Unit
Distributed Base Station: ZXSDR BS8700 Introduction
BBU: B8200
RRU series
Macro Indoor :ZXSDR BS8800
Macro Outdoor: ZXSDR BS8900A
Micro Outdoor:ZXSDR BS8906
Base Band Unit — SDR B8200
Performance Index
19 inch Processing Capability:
UMTS: 30CS ( 6CS *5 BPCs)
2U GSM: 60TRX
88.4mm
Base Band Processing Capability:
Uplink/ Downlink: 960CE
482.6mm
Data Processing Capability:
Downlink: 216Mbps
Based on Unified MicroTCA Platform Uplink: 75Mbps
Uplink:192CE Physical Index
BPC Processing Downlink:192CE
Capability Downlink:43.2Mbps Volume:88.4×482.6×197mm(H×W×D)
Uplink:15Mbps Weight: 8.75kg (full configuration)
Typical Power Consumption :
Interface Index
UMTS: 80W(1BPC), 115W(2BPC)
Abis/Iub Interface:
GSM: 60W(12TRX), 75W(24TRX)
2*STM‐1;16*E1/T1;1*FE/GE Electric/Optical(8 VLAN)
Power Supply: ‐48V DC
To RRU: 12*1.25Gbps CPRI optical interface
Temperature Range: ‐20℃~ 55℃
Humidity Range: 5%~95%
CC Board Introduction
Control & Clock Board
GPS system clock & RF reference clock;
Ethernet switch function, providing switch plan for signaling and media stream;
Rack management
CC Indicators
Board LED Color Meaning Description
On: The board can be unplugged.
Plugging/Unpluggin
HS Blue Flashing: The board is being activated or deactivated.
g Indicator
Off: The board cannot be unplugged.
Always on: The board is in reset state.
RUN Green Running Indicator Flashing at 1Hz: The board is normally running.
Off: Self test fails.
On: The board has an alarm.
Alarm Red Alarm Indicator
Off: The board has no alarm.
Alternate flash for different links; the max 4 flashes per
CC
second; flashing at frequency of 5 Hz.
The first second: one flash means Link 0 is normal and
OFF means Link 0 is not in use.
The third second: two flashes means Link 1 is normal and
E1/T1 status OFF means Link 1 is not in use.
E0S Green
indicator (link 0–3)
The fifth second: three flashes means Link 2 is normal
and OFF means Link 2 is not in use.
The seventh second: four flashes means Link 3 is normal.
and OFF means Link 3 is not in use.
Recycle. Each cycle lasts for eight seconds.
CC Indicators
Board LED Color Meaning Description
E1/T1 status
E1S Green The same as E0S.
indicator (link 4–7)
E1/T1 status
E2S Green The same as E0S.
indicator (link 8–11)
E1/T1 status
E3S Green indicator (link 12– The same as E0S.
15)
Active/Standby On: The board is in active status
MS Green
status indicator Off: The board is in standby status
Power Module
16 internal interface for +12V load power
16 internal interface for +3.3V management power
Measurement and protection of input over‐voltage/under‐voltage;
Output over‐current protection and load power management
SA/SE Board Introduction
Site Alarm
Extender
Site Alarm Board
Site Alarm Board/Site Alarm Extender Board(optional)
Alarm monitor and rev control of no more than 9 fans;
Signal monitor and interface lightning protection for the rack;
Providing 6 input dry contact interfaces, 2 input /output dry contact interface;
Providing 8 lines of E1/T1 interface
SA Jumpers
Jumper X5 is used to set E1/T1 transmission mode.
Fiber Switch Module
Baseband IQ data exchange;
Providing interface between RRU and BBU
Baseband Board Introduction
Baseband Board
RX expand
interface
Baseband Unit and Radio Unit
Distributed Base Station: ZXSDR BS8700 Introduction
BBU: B8200
RRU series
Macro Indoor :ZXSDR BS8800
Macro Outdoor: ZXSDR BS8900A
Micro Outdoor:ZXSDR BS8906
Hardware Architecture of BS8700
BS8700
Antenna
BBU
BB
CPRI
FS RRU
RadioUnit
Radio Unit Fiber
E1
SA/
STM‐1 SE/
NIS CC
GE/FE
Control Signaling
Clock
Data
+ RRU
B8200
The structure of BS8700 is BBU plus RRU, with separated modules as Base band unit and RF unit.
Remote Radio Unit – R8840
160mm
SDR R8840 320mm
Performance Index
Support maximal 4 carriers
Support 1C1S ~ 4C1S
370mm
Output Power: 60W
Receive Sensitivity:
‐126.5dBm@sigle antenna
‐129.2dBm@dual antenna
Frequency: 2100MHz
Physical Index
Volume: 370×320×160mm (H×W×D)
Weight: 16.5kg
Typical Power Consumption:
100W(1C)/125W(2C)/160W (3C)
Power Supply: ‐48V DC
Temperature Range: ‐40℃~+55℃
Protection Class: IP65
Interface Index
2 * 1.25G CPRI Optical Interface
Remote Radio Unit —— ZXSDR R8860
Performance Index
Carrier Configuration:
Support maximal: 6TRX or 4 carriers
Support maximal: 4G1U
Output Power:80W
370mm
Receive Sensitivity: ‐113dBm[GSM]
‐126.5dBm@sigle antenna[UMTS]
‐129.2dBm@dual antenna[UMTS]
Frequency:
850MHz, 900MHz, 1800MHz, 1900MHz
320mm
Interface between
1 LC1
BBU and RRU/RRU cascading interface
Interface between
2 LC2
BBU and RRU/RRU cascading interface
3 AISG AISG device interface
5 DC IN Power interface
Optical link Flash in 5Hz: consider this link as clock reference source,
Link Green
indicator and phase-locked loop in fast capture status
Performance Index
Support maximal 2 X 3 C
340mm
Output Power: 2 X 60W
Receive Sensitivity:
‐126.5dBm@sigle antenna
‐129.2dBm@dual antenna
Transmitter Frequency: 2110MHz~2170MHZ
Receiver Frequency: 1920MHz~1980MHZ
Physical Index
Volume: 420×340×140mm (H×W×D)
Weight: < 20kg
Typical Power Consumption:
S1:135W(Single PA), 215W(double PA)
S2:195W(Single PA), 330W(double PA)
S3:240W(Single PA), 420W(double PA)
Power Supply: ‐48V DC
Temperature Range: ‐40℃~+55℃
Protection Class: IP65
Interface Index
2 * 1.2288G Optical Interface
Remote Radio Unit —— ZXSDR R8882
Performance Index
Carrier Configuration:
Support maximal [UMTS]: 2×3C carriers
Support maximal [GSM]: 2×4 TRX
Support maximal [GU]: 2×4G1U or 2×2G2U
450mm
Output Power:2×60W
Receive Sensitivity: ‐113.5dBm[GSM]
‐113.5dBm@sigle antenna[UMTS]
‐129.2dBm@dual antenna[UMTS]
Frequency: 900M/1800M/2100MHz
320mm
Physical Index
ZXSDR R8882 (2T4R) Volume: 450×320×140mm (H×W×D )
Weight: 20Kg
• Support GSM & UMTS TPC :684W(S3/3/3)
Power Supply: ‐48V DC, 110V AC, 220V AC
Interface Index Temperature Range: ‐40℃~+55℃
2*1.25G CPRI Optical interface (2.5G and
Protection Class: IP65
3.072G are also applicable)
R8882 Structure
R8882 Structure
10 - PE interface
R8882 Indicators
Board LED Color Meaning Description
Always on: The board is in resetting or starting status.
Flashing at 1Hz: The board is normally running.
RUN Green Running indication
Flashing at 5Hz: The board is downloading version.
Off: Self test fails.
Flash in 5Hz: major or critical alarm
Flash in 1Hz: warning or minor alarm
Alarm Red Alarm Indicator
Off: indicates no fault or resetting, starting or
downloading the version.
ON: connection is ok at optical interface 0
R8882 Off: disconnected fiber
Status indication at Flash in 5Hz: consider this link as clock reference source,
LINK1 Green
optical interface 0 and phase-locked loop in fast capture status
Flash in 0.25Hz: consider this link as clock reference
source, and phase-locked loop in trace status
Status indication at
LINK2 Green The same meaning as LINK1
optical interface 1
Green TX0 standing wave ON: TX0 standing wave is ok
VSWR1
indication OFF: TX0 standing wave is improper
TX0 standing wave
VSWR2 Green The same meaning as VSWR1
indication
Rapidly Networking Based on Distributed
Base Station
Light, easy for installation, save project cost
and Shorten the time for building network .
Flexible networking.
Install on
Pole installation top of the tower
Less space required, flexible installation High reliability, suitable for terrible environment
Networking Topology of RRU
Star Topology
RRU
Chain Topology
B8200
RRU
B8200
B8200
RRU RNC/BSC
FE/GE
ZTE provides flexible networking for distributed site such as star, chain, loop and mix
topology to meet demands for customers.
SDR Base Station Introduction
Baseband Unit and Radio Unit
Distributed Base Station: ZXSDR BS8700 Introduction
BBU: B8200
RRU series
Macro Indoor :ZXSDR BS8800
Macro Outdoor: ZXSDR BS8900A
Micro Outdoor:ZXSDR BS8906
Integrated Indoor Macro Site — ZXSDR BS8800
SDR BS8800
Performance Index
Radio Unit: RSU40/
RSU60/RSU82 Processing Capability(with Auxiliary Cabinet):
GSM 36TRX + UMTS12CS
Base Band Processing Capability:
Radio Unit Uplink: 960CE (192CE*5BPC)
Downlink: 960CE (192CE*5BPC)
Output Power: 60W/80W/2*80W(900/1800M), 2*60W(2100M)
Receive Sensitivity:
GSM ‐113dBm@single antenna
UMTS ‐126.5dBm@single antenna
Baseband
BU: B8200 ‐129.2dBm@dual antenna
Unit
Main Cabinet Physical Index
Volume: 950×600×450mm (H×W×D) (Main Cabinet)
Interface Index Weight: main cabinet<135 KG, Auxiliary Cabinet <115KG[with
RSU40/RSU60]
Aibs/Iub Interface:
TPC:
8*E1/T1(Can expand to 16)
RSU82 (850/900M): 1110W[S444]
1*GE/FE Optical or 1*GE/FE Electrical
RSU40 (2100M): 780W[S222]
To remote RRU: 12 *1.25Gbps CPRI Optical Interface
Power Supply: ‐48V DC (‐40~‐57V DC)
BS8800 Hardware Structure
Radio Unit:
RSU40, RSU60,RSU82
Wiring Duct:
Radio Unit Used to walk wiring in rack, such
as fiber or SFP cable between BBU
Power
and RSU40/60/82.
Distribution Module Power Distribution Module:
Passive power distribution unit
Wiring
950mm Transmission Device:
Duct
1U slot, it can provide built‐in
Transmission Fan
transmission or microwave
Device
Ventilation devices to save operators’
Base Band investment.
FAN
Used to perform heat dissipation
for RSU modules, 6 fans in total
450 mm
600mm
BS8800 ——Easy to Stack, Easy to expand
Radio Unit
Cable Chute
950mm
Power Distribution
950mm
Module
Ventilation
Baseband Unit and Radio Unit
Distributed Base Station: ZXSDR BS8700 Introduction
BBU: B8200
RRU series
Macro Indoor :ZXSDR BS8800
Macro Outdoor: ZXSDR BS8900A
Micro Outdoor:ZXSDR BS8906
48
Integrated Outdoor Macro Site – ZXSDR
BS8900A Performance Index
Base Band Unit: ZXSDR BS8900A
B8200 Processing Capability:
GSM 36TRX + UMTS12CS
Output Power:
Radio Unit: 60W/80W
RSU40/60/82
Receive Sensitivity:
GSM ‐113dBm@single antenna
UMTS ‐126.5dBm@single antenna
‐129.2dBm@dual antenna
Physical Index
Volume: 1600×600×600mm (H×W×D)
Interface Index (Standard Configuration)
TPC:
8*E1/T1(Can expand to 16)
RSU82 (900M): 1285W[S444]
1*GE Optical or 1*GE/FE Electrical
RSU40 (2100M): 865W[S222]
2*STM‐1
Power Supply: ‐48V DC, 220V AC, 380V AC
To RRU: 12 *1.25Gbps CPRI Optical interface
ZXSDR BS8900A Hardware Structure
Radio Unit:
Baseband Unit and Radio Unit
Distributed Base Station: ZXSDR BS8700 Introduction
BBU: B8200
RRU series
Macro Indoor :ZXSDR BS8800
Macro Outdoor: ZXSDR BS8900A
Micro Outdoor:ZXSDR BS8906
52
Integrated Micro Outdoor — SDR BS8906
SDR BS8906
Performance Index
Radio Unit:
Processing Capability:
RSU40/60
GSM: 60 carriers; UMTS: 30CS (with outdoor RRU);
GU: 4 TRX + 1 C or 2 TRX + 2 C
Base Band Processing Capability:
Same as B8200
Output Power:
RSU60: GMSK 80W / 8PSK 50W/UMTS 80W
RSU40: 60W
B8200 Receive Sensitivity:
GSM: -113dBm @ single antenna
UMTS: -126.5dBm @ single antenna
-129.2dBm @ dual antenna
BS8906 can be connected with RRU for outdoor
BBU solution.
Physical Index
Interface Index
Volume: 650 × 320 × 480 mm (H×W×D)
Abis/Iub Interface:
Weight: 52kg
8*E1/T1(Can expand to 16)
TPC:RSU60(DC): 445W/900M; 460W/1800M(S4)
1*GE/FE Optical or 1*GE/FE Electrical
Power Supply: -48V DC, 110~240V AC
To RRU: 12 *1.25Gbps CPRI Optical Interface
BS8906 Hardware Structure
FCE:Fan Control
Element
LPU: Line Lightning
Protection Unit
PSU:Power System
Unit
APM:AC Protection
Module
DPM:DC Protection
Module
Content
UMTS Node B
Remote RRU
Independent
UMTS RAN IP/SDH
Backbone
Traditional Solution
GSM900
UMTS900
Dynamic Power Sharing Enlarging Site Coverage
The sum of each TRX configured maximum output power is bigger than PA maximum output power.
In the area with little traffic, BCCH carrier power configuration can be appropriately added by taking use
of dynamic power, and the remaining power is dynamically real-time shared among all TCH carriers to
enlarge coverage and reduce site quantity.
BCCH 40w
carrier
BCCH 30w User A TCH
5w 30w
carrier carrier A
TCH 30w 30w
TCH 15w 30w carrier B
carrier A
BCCH 40w
TCH 20w 20w carrier
carrier B TCH
User A 15w 30w
carrier A
TCH 20w 30w
carrier B
User B As user moves, each TRX transmission
The sum of each TRX maximum transmission power is no
SDR Base IP A
Station Flex A
iBSC IP Ater
MSC Server
MGW2
IP Abis
MGW1
IP Gb
SDR
Base Flex Gb
Station
SGSN1 SGSN2
GGSN
One logical Cell with Multi RRU dramatically reduces inter-cell switch, Remote expansion
and improves wireless utilization. Software configuration
Measured UL datarate (Kpbs) of high speed railway scenario Cell A Cell A
110110
100 Multi RRU and AFC disable
73.2 72.8
63.9 Only AFC enable
35.7 •BCCH carrier power unchanged
50 29.8 Only Multi RRU enable •Increasing TCH carrier, using
12.5 12.8 reserved frequency point to absorb
00 000 Multi RRU and AFC enable traffic
0 •Not changing existing network
0kmph 400kmph 600kmph 800kmph frequency planning
SDR-Based Network Effectively Reducing Energy Consumption
Highly Efficient PA Improving Overall Antenna-Close Installation Avoiding Feeder
Efficiency Loss
Typical consumption for S444
1250W
PA module adoptes Power consumption RRU
Doherty, DPD and descreased by 42%
multi-carrier PA, 725W RRU RRU is installed close to
increasing overall antenna, saving feeder loss.
efficiency to over For the same coverage
20%. requirement, it reduces RF
output power, hence lowering
BBU power consumption.
Traditional BaseMulti-carrier Base
Station Station
Intelligent Software Power Saving Networking Mode Saving Energy Consumption
Technology
RRU adopts natual cooling system, BBU features in low
power consumption and concentration which requires less
It supports some latest energy saving technologies such as
equipment room and greatly reduces corollary equipments
intelligent voltage adjustment, carrier priority control and
and air-conditioner’s power consumption.
RRU module shutdown.
T T T T T T
R R R R R R
X X X X X X
1 2 3 4 5 6
Multi-carrier PA
Constructing network by using SDR-based Base Station averagely saves single site’s energy by over 40%.
Diverse Networking, tridimensional Coverage
Coverage Challenge in
Dense Urban
One person
Horizontal
Directly on the wall
installation in weight