Professional Documents
Culture Documents
Lot 41, Tingkat 1, Jalan Dato' Muda Jaafar, 44000 Kuala Kubu Bharu, Hulu Selangor, Selangor
Lot 41, Tingkat 1, Jalan Dato' Muda Jaafar, 44000 Kuala Kubu Bharu, Hulu Selangor, Selangor
Lot 41, Tingkat 1, Jalan Dato' Muda Jaafar, 44000 Kuala Kubu Bharu, Hulu Selangor, Selangor
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Vibration isolator
2 Electric motor
3 Housing
4 Housing support
5 Bearing support
6 Motor base frame
7 Impeller
8 Drive shaft
9 Bearing
10 Fan drive
11 Belt guard
12 Casing
13 Mounting
14 Noise level
15 Axial flow
16 Conduits
17 Wiring
18 Flexible connection
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
AIR-CONDITIONING & VENTILATION SERVICES (Fan coilunit & air- cooled condensing unit)
Location
Block : Structure/
Zone / grideline : Element :
Level :
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
AIR-CONDITIONING & VENTILATION SERVICES (Fan coilunit & air- cooled condensing unit)
Location
Block : Structure/
Zone / grideline : Element :
Level :
1 Casing
2 Drain pan
3 Blower
4 Cooling coils
5 Filters
6 Compressor
7 Coating of units
8 Bolt and nuts
9 Insulation of pipework
10 Fins
11 Installation of FCU
12 Hanger
13 Brackets
14 Refrigerants used
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Incoming isolator
2 Circuit breaker
3 Phase indicating lights
4 Starter
5 Contractor indicating light
6 Fuses
7 Current transformer
8 Relay fo fore mode
9 Weatherproof panel
10 Cable gland
11 Push buttons control
12 Auto / manual selector switch
13 Ammeter
14 Cables connections
15 Conduit installation
16 Trunking and trays installation
17 Thermostat relay
18 Timer switch
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Dimension
2 Material
3 Plinths positions
4 Inlet pipe size
5 Inlet pipe position / location
6 Outlet pipe size
7 Outlet pipe position / location
8 Warning pipe size
9 Warning pipe position / location / discharge
10 Overflow pipe size
11 Overflow pipe position / location / discharge
12 Scour pipe sie
13 Scour pipe position / location / discharge
14 Manhole opening
15 Gaskets
16 Bolting
17 Non-toxic epoxy resin coating
18 Water level indicator
19 Vent
20 Ball float valve
21 Internal support
22 Internal and external cat-ladders
23 Leak test
Inspection response : Remarks:
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
SANITARY (INTERNAL)
Location
Block : Structure/
Zone / grideline : Element :
Level :
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
SEWERLINE CONNECTION
Location
Block : Structure/
Zone / grideline : Element :
Level :
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Material of pipe
2 Pipe size
3 Setting out / alignment
4 Verticality of pipe
5 Pipe hangers
6 Pipe brackets
7 Pipe sleeves
8 Pipe fittings
9 Pipe jointing
10 Pressure test
11 Gate valve
12 Ball valve
13 Painting
14 Excavation work
15 Bedding for pipes
16 Shorinf / slopes
17 Backfilling / compacting
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
FIRE PROTECTION SERVICES (Water storage tank for hose reel system)
Location
Block : Structure/
Zone / grideline : Element :
Level :
1 Dimension
2 Material
3 Pinths positions
4 Inlet pipe size
5 Inlet pipe position / location
6 Outlet pipe
7 Outlet pipe position / location
8 Warning pipe size
9 Warning pipe position / location
10 Overflow pipe size
11 Overflow pipe position / location / discharge
12 Scour pipe size
13 Scour pipe position / location / discharge
14 Manhole opening
15 Gaskets
16 Bolting
17 Non - toxic epoxy resin coating
18 Water level indicator
19 Vent
20 Ball float valve
21 Internal support
22 Internal and external caat-ladders
23 Leak test
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Pump manufacturer
2 Pump characteristic (base plate)
3 Vibrator isolator
4 Plinth
5 Pump casing
6 Pump impeller
7 Shaft
8 Shaft sleeves
9 Shaft seal
10 Wear ring
11 Bolts, nuts and fasteners
12 Flexible coupling
13 Bearing
14 Electric motor
15 Diesel engine
16 Painting
17 Drain pipe
18 Labelling
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Assembly of panel
2 Material used for construction the panel
3 Paint work
4 Indicating lights
5 Phase indicators
6 Motor starter
7 Pump selector switch
8 Automatic / manual mode selector switch
9 Stop / start button
10 Main isolating switch fuses
11 Voltmeter
12 Ammeter
13 Fuse switch unit
14 Contractors
15 Relays
16 Terminal blocks
17 Battery & battery charger
18 Mimic diagram
19 Cable gland
20 Wiring / cabling
21 Terminations
22 Conduits / trunking / cable tray
23 Labelling
24 Fault / alarm test
25 Fault alarm
Inspection response : Remarks:
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
ELECTRICAL FITTING
Location
Block : Structure/
Zone / grideline : Element :
Level :
1 Emergency light
2 Wall light
3 Down light
4 Ceiling fans
5 Ceiling light
6 Ceiling fan regulator
7 Fluorescent fitting
8 Water heater
9 Power outlet
10 Light switches
11 Light fixture installation
12 Final position of outlet and lighting points
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Compound lighting
2 Street lighting
3 Weatherproof nature
4 Armoured cable & cable sizing
5 Anti rust primer
6 Type of pole (planted type / concrete)
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Manholes
2 Underground ducts
3 Duct seal
4 Underground cables
5 Finished level of manhole
6 Depth of trench
7 Cable marker
8 Sand bedding
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
1 Rust or scale
2 Angle frame
3 Concealed type
4 Baked powder paint
5 Busbar and cable ducts
6 Circuit brakers
7 HRC fuses
8 On-load isolator
9 Balancing of load
10 Labels
11 Earth leakage circuit breakers (ELCB)
12 Control relay
13 Terminal block
14 Magnet coil
15 Vacum impregnated contractor
16 Type of distribution board
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
TELEPHONE SERVICES
Location
Block : Structure/
Zone / grideline : Element :
Level :
To : Ref. No :
Attention : Date :
Request by : Received by :
Name : Name :
Company : Company :
Time : Date : Time : Date
MATV
Location
Block : Structure/
Zone / grideline : Element :
Level :
1 Channelised antena
2 Amplifier c/w power supply
3 Channel mixer
4 4 way splitter
5 2 way splitter
6 4 way tap off
7 2 way tap off
8 Cabling
9 TV/FM wiring c/w socket outlet
10 75 ohm terminator
11 Test system function