Polity

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PLINTH BEAMS STEEL DESIGN

BOTTOM TOP M.B(3L/5) EXTRA


MARK SIZE STEEL STEEL STEEL RINGS MIX
full span full span STEEL L/4 at top
B1 9"X15" 2-16Ø 2-12Ø - 2-16Ø 8Ø @6"/8"c/c 1:1½:3

B2 9"X12" 2-12Ø 2-12Ø - 2-12Ø 8Ø @7"c/c 1:1½:3

B3 9"X12" 2-12Ø 2-12Ø - 1-12Ø 8Ø @7"c/c 1:1½:3

B4 9"X12" 2-12Ø 2-12Ø - - 8Ø @6"c/c 1:1½:3

NOTE : ALL PLINTH BEAMS AT PARKING LEVEL


STAIRCASE MID LANDING BEAM
plinth beams &
BOTTOM TOP EXTRA
column's overlap
MARK SIZE
STEEL STEEL STEEL
RINGS MIX steel requirement
16mm - 13 no's
L-BEAM 9"X18" 2-16Ø L 4-16Ø L - 8mm@6"c/c 1:1½:3 12mm - 40 no's
10mm - 15 no's
8mm - 65 no's
WAIST SLAB STEEL DESIGN B/W - 15 Kg's
Main steel Distribution Extra steel Extra steel
Thick @ steel @ @ @ MIX
ness short span long span short span Long span

6" 12mm@6"c/c 8mm@7"c/c 12mm@6"c/c - 1:1½:3 NOTE: USE 53GRADE OPC CEMENT ONLY
FOR ALL R.C.C STRUCTURES
EXTRA STEEL EXTRA STEEL
TOP STEEL
L/4 L/4

MR:K.SRIDHAR
BOTTOM STEEL MIDDLE BOTTOM STEEL
(3L/5) RINGS PLINTH BEAMS &
KEY BEAM TYPE - 2 STAIR CASE STEEL DESIGN

DATE :27-12-2022