Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Pos.

Reinforcement Shape
24

-47

0.0
1 22Ø19,1 l=1.65

44
21

A B
2 2Ø28,7 l=2.56

48

48
2Ø28,7 1.77
2 l=2.56

3 2Ø28,7 l=3.25

30
30
2.60

2Ø28,7
V1 3 l=3.25 P1 V2
0.0

51

5 9x19 5
6x15 6x15
50 3.60 30

A-A B-B

2Ø28,7
l=2.56 2
22Ø19,1 22Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=3.25 3 l=3.25 3
30 30

Tel. Fax fc' 35MPa = 0.637 m3

Beam521...541
Formwork = 5.48 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 1
Pos. Reinforcement Shape

1.29

2.29
24

0.0
1 22Ø19,1 l=1.65

44
21

C D
3 2Ø28,7 l=3.25

30
30
2Ø28,7 2Ø28,7 2.60
4 l=3.55 5 l=3.45

4 2Ø28,7 l=3.55

30
30
2.90

5 2Ø28,7 l=3.45

30
30
2.80

2Ø28,7
V2 3 l=3.25 P2 V3
0.0

51

5 9x19 5
6x15 6x15
30 3.60 50

C-C D-D

2Ø28,7
l=3.55 4
22Ø19,1 22Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=3.25 3 l=3.25 3
30 30

Tel. Fax fc' 35MPa = 0.6 m3

Beam521...541
Formwork = 5.08 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 2
Pos. Reinforcement Shape
24
1 16Ø19,1 l=1.65

44
21

E F
6 2Ø28,7 l=2.65

30
30
2.00

2Ø28,7
V3 6 l=2.65 P3 V4

0.0

31
5 7x19 5
4x15 4x15
50 2.60 30

E-E F-F

16Ø19,1 16Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=2.65 6 l=2.65 6
30 30

Tel. Fax fc' 35MPa = 0.45 m3

Beam521...541
Formwork = 3.78 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 3
Pos. Reinforcement Shape
24

0.0

99
1 16Ø19,1 l=1.65

44
21

G 2Ø28,7 H
6 2Ø28,7 l=2.65

30
30
2Ø28,7 2Ø28,7 2.00
6 9 l=2.95
l=2.65 8 l=23.23

7 2Ø28,7 l=23.09

30
30
22.44

8 2Ø28,7 l=23.23

48

48
22.44

9 2Ø28,7 l=2.95

30
30
2.30

2Ø28,7 2Ø28,7
V4 6 l=2.65 P4 7 l=23.09 V5
0.0

5 31 7x19 5
4x15 4x15
30 2.60 50

G-G H-H
2Ø28,7
l=2.95 9
2Ø28,7 2Ø28,7
l=23.23 8 l=23.23 8
16Ø19,1 16Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=2.65 6 l=2.65 6
2Ø28,7 2Ø28,7
l=23.09 7 30 l=23.09 7 30

Tel. Fax fc' 35MPa = 0.45 m3

Beam521...541
Formwork = 3.78 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 4
Pos. Reinforcement Shape

1.29
24

0.0
1 22Ø19,1 l=1.65

44
21

I J
3 2Ø28,7 l=3.25

30
30
2Ø28,7 2.60
5 l=3.45

5 2Ø28,7 l=3.45

30
30
2.80

2Ø28,7
V5 0.0 3 l=3.25 P5 V6

51
5 9x19 5
6x15 6x15
50 3.60 30

I-I J-J

2Ø28,7
l=3.45 5
22Ø19,1 22Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=3.25 3 l=3.25 3
30 30

Tel. Fax fc' 35MPa = 0.6 m3

Beam521...541
Formwork = 5.08 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 5
Pos. Reinforcement Shape

1.29

2.29
24

0.0
1 22Ø19,1 l=1.65

44
21

K L
4 2Ø28,7 l=3.55

30
30
2Ø28,7 2Ø28,7 2.90
4 l=3.55 11 l=2.42

10 2Ø28,7 l=2.60 2.60

11 2Ø28,7 l=2.42

30
30
1.77

2Ø28,7
V6 10 l=2.60 P6 V7
0.0

50

5 9x19 5
6x15 6x15
30 3.60 50

K-K L-L

2Ø28,7
l=3.55 4
22Ø19,1 22Ø19,1
50

50
l=1.65 1 l=1.65 1
2Ø28,7 2Ø28,7
l=2.60 10 l=2.60 10
30 30

Tel. Fax fc' 35MPa = 0.637 m3

Beam521...541
Formwork = 5.48 m2
Bottom cover 3 cm Top cover 3 cm
Side cover 3 cm

STR_ATP_EFCONS_BLD-A_R2 Section 30x50 View scale 1:33


Section scale 1:20 Page 6

You might also like