Design Summary

Provided / Required / Design


Sl.No Description Capacity loads Remarks
1 Steel girder section is classified as Plastic OK
2 ULS Moment Carrying Capacity - Construction stage (kN-m) 198 837 NOT OK
3 SLS- Max. Stress at top of Deck slab (Mpa) 19.20 5.82 OK
4 SLS- Max. Stress at top flange of steel section (Mpa) 200.10 306.20 NOT OK
5 SLS- Max. Stress at bottom flange of steel section (Mpa) 200.10 341.69 NOT OK
6 ULS Moment Carrying Capacity - Service stage (kN-m) 2904.41 5359.83 NOT OK
7 ULS Shear Capacity - Service stage (kN-m) 377.90 691.29 NOT OK
8 SLS - Fatigue Normal stress at top flange of steel section (Mpa) 59.33 14.51 OK
9 SLS - Fatigue Normal stress at bottom flange of steel section (Mpa) 59.33 23.07 OK
10 SLS - Fatigue Shear stress in steel section (Mpa) 59.33 143.75 NOT OK
11 ULS - Shear studs spacing corresponding to vertical shear (mm) 150.00 1187.09 OK
12 ULS - Shear studs spacing corresponding to full shear connection (mm) 150.00 1688.19 OK
13 SLS - Shear studs spacing corresponding to fatigue strength (mm) 150.00 688.46 OK
14 ULS - Transverse shear check (kN/m) 1412.23 368.97 OK
15 Deflection under all loads (mm) 21.67 9.00 OK
16 Deflection under live loads (mm) 16.25 7.00 OK