Hardware Trigger Manual
1. GPIO Principle
On Hardware:
(1)All input and output are isolated by optocoupler;
(2)Input voltage is 5~24V;
(3)Output is open drain and maximum current must not exceed 50mA.
Camera
i Current Limiter
so: TRIG_IN+:
2 { 2 TRIGIN- ; Double-Ended Input And Output
1 ‘ STRB_OUT+!
ot Ks STRB_OUT-'
Current Limiter ~ 24V
sc) GPI_IN+ :
“4 4 Positive Power Level/Pulse
2 2
| Single-Ended Input And Output
1 < GPO_OUTS i sink Output
’ :
2 3 | GPT0_COM ‘common Terminal Common Cathode
Notice:
(1)
Double-ended input, can be connected to NPN and PNP switches;
Double-ended output, can drive common anode and common cathode loads.
(2)
jle-ended input can only be connected to PNP type switch;
Single-ended outputs can only drive common anode loads;
Common terminal of the single-ended type can only be connected to the negative pole of the power supply.2. Wiring Reference Diagram
Note:
Power supply is an external power supply,the voltage between the positive pole and
negative pole of the power supply is 5~24V, and the red identification line is the wire.
( Additional power must be added, not provided by the camera )
(1) Camera input end is connected to NPN type and PLC output end
Li eacclecioa) PLC: NPN sink output (negative ec mn)
= TRIG sink ouput negative comme
i stp sty
a 14 Tris ovr ® yA 4
2 ‘
cua ro ® &
7 %
(2) Camera input end is connected to PNP type and PLC output end
PLE: PNP sink output ostve common)
Poste owe so ® r
ld Camare al [ys
Inside i {112
= TRIG our % %
a
a| 4 TIC=| Sevan
s [Negative power supr
(3) Camera output end is connected to the common anode and PLC input end
PLC: Positive common terminal
Inside Camera 1
| een
ARC, =| aeweeton | mPOT
(Oe Ra
aa(4) Camera output end is connected to the common anode and PLC input end
oe ie ie
Inside Camera
1 ‘ th , LE: Negative common terminal
KT. 7 veut =
— * x
Current direction #
ven psy 2
(5) Camera input and NPN photoelectric switch connection
tov power ae
ae Ha
tnside Camera
TRIG+
4 vvv
» t TRIG-
cnn
Negative power suppl
(6) Camera input and PNP photoelectric switch connection
oe eS
Inside Camera
TRIG+
~
TRIG-
Zea
Negative power supply
NPN
vec
our A
B
Cy
cy
GND
PNP.
vec
18
our a
3
GND