1. Overview

.,L
The working principle of the oval gear flow meter is that a pair of elliptic gears is
driven to rotate by liquid. The volume of every cavity is fixed. The revolution speed

O
of the gear is acquired and the sensor sends out sync pulses to count. Then the rotation

C
of the elliptic gear is transmitted to the counter through a magnetic sealed coupler and
transmission speed reduction device to directly show the total amount flowing

G
through the flow meter. If the transmitting device and electric display meter are
equipped, it may transmit the instantaneous flow rate or cumulative flow rate over a

IN
long distance.

R
2. Features EE
The oval gear flow meter is mainly used to measure media of high viscosity.
This product is widely applicable in the industries of petroleum, petrochemical
IN

engineering, natural gas, chemical engineering, paper-making, etc. which is used to


measure and count micro flow rate in small caliber. Advantages:
G

(1) The caliber ranges within 10~150mm;


(2) There are many shells of various materials for choice, including: aluminum,
EN

stainless steel and medium-high pressure stainless steel, PPS, bronze, etc.;
(3) There are many bearings of various materials for choice, including: ceramics,
bronze, Hostelry alloy, carbonization, PPS, stainless steel, etc.;
EL

(4) Material of the shaft: 316 stainless steel;


(5) The materials of the O-ring include choices of VITON, floors rubber, stainless
steel and Teflon;
C

(6) Measurement range ratio 10:1, maximum ratio 50:1;


EX

(7) The precision has two types, ±1% and ±0.5%, and the repetitiveness is ±0.03%;
(8) Requirement for straight pipe during installation: 5D 3D, A filter should be
installed;
(9) Maximum viscosity may reach 1,000,000CP;
A

(10) Maximum pressure level may reach 6.3Mpa;


H

(11) Maximum temperature resistant level may reach -20~400℃;


LP
A

2
.
3. Working principle

TD
.,L
Oval Gear Flow meter Oval Gear Flow meter working principle of measurement
of some of the major consists of two elliptical gears meshing with each other and the
casing (measuring chamber) of the composition, as shown below:

O
C
G
IN
R
EE
4. Main technology data
IN

Material: stainless steel / cast-iron / cast steel / aluminum


DN range (mm): DN8-DN250
G

Accuracy: 0.2% / 0.5%


Medium: Liquid / oil
EN

Output: pulse / current4-20mA / RS485 / Hart


Viscosity Range: 0.1-1000mPa.s
Power supply: 220VAC / 24VDC / 4VDC/as required
EL

Medium temperature (centigrade): -20-400


Ambient temperature (centigrade): -30-70
C

Nominal Pressure: 1.6 / 2.5 / 4.0 / 6.3MPa


Anti-Explosion Grade: IaIICT4, dIIBT4
EX

Connection Flange: GB9115.0719-2000 JB/TB2-94 or other customer named


Standard
A
H
LP
A

3
5. Data and dimension

.
TD
.,L
O
C
G
IN
R
EE
IN

Flow range (accuracy 0.5)


G

DN Flow range(m³/h)
EN

petroleum products Chemical liquids

(mm) 0.6-2(cp) 2-8(cp) 8-200(cp) 0.6-200(cp)


8 0.05-0.1 0.02-0.2 0.01-.02 0.04-0.2
EL

10 0.1-0.4 0.04-0.4 0.025-0.4 0.08-0.4


15 0.38-1.5 0.15-1.5 0.1-1.5 0.3-1.5
20 0.75-3.0 0.3-3 0.2-3 0.6-3
C

25 1.5-6.0 0.6-6 0.4-6 1.2-6


EX

40 3-15 1.5-15 1-15 2.4-12


50 4.8-24 2.4-24 1.6-24 3.8-19
80 12-60 6-60 4-60 9.5-48
100 20-100 10-100 6.5-100 16-80
A

150 38-190 19-190 12.5-190 25-125


H

200 68-340 34-340 22.5-340 45-225


250 108-503 53-530 35-530 70-350
LP
A

4
.
TD
Flow range (accuracy 0.2)

.,L
DN(mm) Flow range(m³/h)
petroleum products

O
2-200(cp)
8 0.05-0.1

C
10 0.1-0.4
15 0.3-1.5

G
20 0.6-3

IN
25 1.2-6
40 3-15
50 4.8-24

R
80 12-60 EE
100 20-100
150 38-190
200 68-340
IN

250 106-530
G
EN