HOT DIP GALVANIZING THICKNESS INSPECTION REPORT Page : 1 of 1
Standard ASTM A123/123M-15 BS EN ISO 1461:2009 / EN ISO 1460:2009(E) AS / NZS 4680 - 2006
All Specimens Tested Minimum Coating Thickness and Mass Requirement for Coating Thickness and Mass
Steel Thickness Range (Measured), in (mm) on Samples that are not Centrifuged for Articles that are not Centrifuged
<1.6 >=1.6 to >=3.2 to >=4.8 to >=6.4 to >16 Local coating Average coating Average coating
Material Category Local coating Local coating Mean coating Mean coating
<3.2 <4.8 < 6.4 <16 Article and its Article thickness thickness mass
thickness mass thickness mass
Structural Shapes 45 65 75 75 100 100 thickness
thickness (minimum) a (minimum) b (minimum) c (minimum) d minimum minimum minimum
Strip and Bar 45 65 75 75 75 100 mm
µm g/m² µm g/m² µm µm g/m²
Plate 45 65 75 75 75 100
Steel >6 mm 70 505 85 610 <= 1.5 35 45 320
Pipe and Tubing 45 45 75 75 75 75
Steel >3 mm <= 6mm 55 395 70 505 > 1.5 <= 3 45 55 390
Wire 35 50 60 65 80 80
Steel >=1.5mm <=3mm 45 325 55 395 > 3 <= 6 55 70 500
Reinforcing Bar ... ... ... ... 100 100
Steel <1.5 mm 35 250 45 325 >6 70 85 600
Equivalent coating mass using formula : g/m² = µm x 7.067 Casting >=6 mm 70 505 80 575 NOTE : 1 g/m² coating mass = 0.14 µm coating thickness
SNI 0039 : 2013 Thickness minimum 42 µm, Casting <6 mm 60 430 70 505
Equivalent coating mass using formula : g/m² = µm, x 7.067 Equivalent coating mass using a nominal coating density of 7.2 g/cm³