[PLANT OVERALL]_STEAM BLOWING – OUT PROCEDURE (FOR BLOCK 3, 4)

MRT-YR01-P3ZEN-110103

Detailed step no. : 1B

Pupose : HRSG Reheater Line and HP/IP/LP Bypass Upstream Line Flushing

Blow path : HP/IP : HRSG HP SH → HP Bypass Upstream Line → HP Bypass (Blow-Out Tool)
→ HRSG RH → IP Bypass Upstream → IP Bypass → Temporary Piping → Steam
Blowing MOV → Silencer
LP : HRSG LP SH → LP Steam Line → LP Bypass → Temporary Piping → Steam
Blowing MOV → Silencer

Firing HRSG Unit : HRSG #1 HRSG #2 HRSG #3


O O O

HRSG operating condition :


HP LP
Pressure bar.a 25 6.3
Temperature deg.C 350 265

Analysis result
HP HP CRH HRH HRH
UOM
(Each) (Common) (Each) (Each) (Common)
Flushing case
Pressure bar.a 21.49 17.55 12.12 10.84 10.08
Temperature deg.C 344.7 337.6 336.3 335.4 333.8
Mass flow rate t/h 146.4 146.4 146.4 146.4 439.2
Density kg/㎥ 7.85 6.45 4.41 3.94 3.67
Momentum m´2/ρ 2729.1 3324.4 4856.7 5435.7 52541.4
Max. operating case
Pressure bar.a 125.91 125.91 26.09 24.13 23.41
Temperature deg.C 523.0 523.0 306.9 515.5 515.1
Mass flow rate t/h 168.3 168.3 162.1 162.1 486.2
Density kg/㎥ 37.68 37.68 10.42 6.74 6.54
Momentum m´2/ρ 751.4 751.4 2521.7 3894.8 36139.9
3.63 4.42 1.93 1.40 1.45
Cleaning Force Ratio > 1.0
OK OK OK OK OK
LP LP
UOM
(Each) (Common)
Flushing case
Pressure bar.a 5.48 5.28
Temperature deg.C 264.1 263.6
Mass flow rate t/h 84.5 253.4
Density kg/㎥ 2.25 2.17
Momentum m´2/ρ 3174.6 29649.6
Max. operating case
Pressure bar.a 6.32 6.00
Temperature deg.C 288.4 287.9
Mass flow rate t/h 76.4 225.3
Density kg/㎥ 2.48 2.35
Momentum m´2/ρ 2357.5 21549.6
> 1.0 1.35 1.38
Cleaning Force Ratio
OK OK

Rev.1 17 of 22
[PLANT OVERALL]_STEAM BLOWING – OUT PROCEDURE (FOR BLOCK 3, 4)
MRT-YR01-P3ZEN-110103

Detailed step no. : 2

Pupose : TBN Steam Admission Line Blowing with Target Plate

Blow path : HP/IP : HRSG HP SH → HP Steam Line → MSV → NRV → HRSG RH → IP


Steam Line → CRV → Temporary Piping → Steam Blowing MOV → Silencer
LP : HRSG LP SH → LP Steam Line → LP TBN Inlet Strainer → Temporary Piping
→ Steam Blowing MOV → Silencer

Firing HRSG Unit : HRSG #1 HRSG #2 HRSG #3


O O O

HRSG operating condition :


HP LP
Pressure bar.a 30 6.3
Temperature deg.C 350 265

Analysis result
HP HP CRH CRH
UOM
(Each) (Common) (Each) (Common)
Flushing case
Pressure bar.a 26.09 15.42 11.09 11.34
Temperature deg.C 344.7 326.6 329.8 330.2
Mass flow rate t/h 135.6 406.8 135.6 406.8
Density kg/㎥ 9.63 5.76 4.08 4.17
Momentum m´2/ρ 1910.2 28747.9 4510.2 39704.2
Max. operating case
Pressure bar.a 125.91 122.13 26.09 26.62
Temperature deg.C 523.0 521.3 306.9 307.5
Mass flow rate t/h 168.3 504.8 162.1 486.2
Density kg/㎥ 37.68 36.54 10.42 10.63
Momentum m´2/ρ 751.4 6973.6 2521.7 22238.6
2.54 4.12 1.79 1.79
Cleaning Force Ratio > 1.0
OK OK OK OK
HRH HRH LP LP
UOM
(Each) (Common) (Each) (Common)
Flushing case
Pressure bar.a 9.47 8.48 5.42 5.19
Temperature deg.C 329.3 325.5 264.0 263.4
Mass flow rate t/h 135.6 406.8 86.8 260.4
Density kg/㎥ 3.47 3.12 2.22 2.13
Momentum m´2/ρ 5296.8 52977.0 3385.9 31791.1
Max. operating case
Pressure bar.a 24.13 23.41 6.32 6.00
Temperature deg.C 515.5 515.1 288.4 287.9
Mass flow rate t/h 162.1 486.2 76.4 225.3
Density kg/㎥ 6.74 6.54 2.48 2.35
Momentum m´2/ρ 3894.8 36139.9 2357.5 21549.6
> 1.0 1.36 1.47 1.44 1.48
Cleaning Force Ratio
OK OK OK OK

Rev.1 18 of 22
[PLANT OVERALL]_STEAM BLOWING – OUT PROCEDURE (FOR BLOCK 3, 4)
MRT-YR01-P3ZEN-110103

9.7.2. For Block #4

Detailed step no. : 1A

Pupose : HRSG HP/LP SUPERHEATER LINE AND TBN SEAL STEAM PRDS
UPSTREAM LINE FLUSHING

Blow path : HP : HRSG HP SH → HP Steam Line → MSV and TBN Seal Steam PRDS →
Temporary Piping → Steam Blowing MOV → Silencer
LP : HRSG LP SH → LP Steam Line → LP Bypass → Temporary Piping → Steam
Blowing MOV → Silencer

Firing HRSG Unit : HRSG #1 HRSG #2 HRSG #3


O O O

HRSG operating condition :


HP LP
Pressure bar.a 20 6.3
Temperature deg.C 300 265

Analysis result
HP HP TBN Seal LP LP
UOM
(Each) (Common) Steam (Each) (Common)
Flushing case
Pressure bar.a 17.46 7.65 7.37 5.63 5.48
Temperature deg.C 296.6 274.5 274.2 264.3 264
Mass flow rate t/h 96.4 289.2 4.3 78.2 234.6
Density kg/㎥ 6.96 3.09 2.98 2.31 2.25
Momentum m´2/ρ 1336.3 27029.1 6.2 2648.0 24486.4
Max. operating case
Pressure bar.a 124.19 120.46 120.46 6.31 6.00
Temperature deg.C 520.7 519.0 519.0 288.4 288.0
Mass flow rate t/h 166.2 498.6 5.3 76.3 225.2
Density kg/㎥ 37.26 36.14 36.14 2.48 2.35
Momentum m´2/ρ 741.3 6879.5 0.8 2348.7 21534.1
1.80 3.93 7.94 1.13 1.14
Cleaning Force Ratio > 1.0
OK OK OK OK OK

Rev.1 19 of 22
[PLANT OVERALL]_STEAM BLOWING – OUT PROCEDURE (FOR BLOCK 3, 4)
MRT-YR01-P3ZEN-110103

Detailed step no. : 1B

Pupose : HRSG Reheater Line and HP/IP/LP Bypass Upstream Line Flushing

Blow path : HP/IP : HRSG HP SH → HP Bypass Upstream Line → HP Bypass (Blow-Out Tool)
→ HRSG RH → IP Bypass Upstream → IP Bypass → Temporary Piping → Steam
Blowing MOV → Silencer
LP : HRSG LP SH → LP Steam Line → LP Bypass → Temporary Piping → Steam
Blowing MOV → Silencer

Firing HRSG Unit : HRSG #1 HRSG #2 HRSG #3


O O O

HRSG operating condition :


HP LP
Pressure bar.a 25 6.3
Temperature deg.C 350 265

Analysis result
HP HP CRH HRH HRH
UOM
(Each) (Common) (Each) (Each) (Common)
Flushing case
Pressure bar.a 21.53 17.77 12.56 11.41 10.66
Temperature deg.C 344.5 338.0 336.8 336.6 334.5
Mass flow rate t/h 144.2 144.2 144.2 144.2 432.7
Density kg/㎥ 7.87 6.53 4.57 4.15 3.88
Momentum m´2/ρ 2643.0 3188.0 4549.3 5017.8 48230.2
Max. operating case
Pressure bar.a 124.19 124.19 25.73 23.81 23.09
Temperature deg.C 520.7 520.7 305.2 513.3 513.0
Mass flow rate t/h 166.2 166.2 160.1 160.1 480.3
Density kg/㎥ 37.26 37.26 10.30 6.67 6.47
Momentum m´2/ρ 741.3 741.3 2487.0 3841.1 35641.0
3.57 4.30 1.83 1.31 1.35
Cleaning Force Ratio > 1.0
OK OK OK OK OK
LP LP
UOM
(Each) (Common)
Flushing case
Pressure bar.a 5.63 5.48
Temperature deg.C 264.3 264
Mass flow rate t/h 78.2 234.6
Density kg/㎥ 2.31 2.25
Momentum m´2/ρ 2648.0 24486.4
Max. operating case
Pressure bar.a 6.31 6.00
Temperature deg.C 288.4 288.0
Mass flow rate t/h 76.3 225.2
Density kg/㎥ 2.48 2.35
Momentum m´2/ρ 2348.7 21534.1
> 1.0 1.13 1.14
Cleaning Force Ratio
OK OK

Rev.1 20 of 22
[PLANT OVERALL]_STEAM BLOWING – OUT PROCEDURE (FOR BLOCK 3, 4)
MRT-YR01-P3ZEN-110103

Detailed step no. : 2

Pupose : TBN Steam Admission Line Blowing with Target Plate

Blow path : HP/IP : HRSG HP SH → HP Steam Line → MSV → NRV → HRSG RH → IP


Steam Line → CRV → Temporary Piping → Steam Blowing MOV → Silencer
LP : HRSG LP SH → LP Steam Line → LP TBN Inlet Strainer → Temporary Piping
→ Steam Blowing MOV → Silencer

Firing HRSG Unit : HRSG #1 HRSG #2 HRSG #3


O O O

HRSG operating condition :


HP LP
Pressure bar.a 30 6.3
Temperature deg.C 350 265

Analysis result
HP HP CRH CRH
UOM
(Each) (Common) (Each) (Common)
Flushing case
Pressure bar.a 26.38 14.84 10.93 11.49
Temperature deg.C 345.0 328.3 329.5 329.5
Mass flow rate t/h 133.1 399.2 133.1 399.2
Density kg/㎥ 9.73 5.52 4.02 4.23
Momentum m´2/ρ 1819.6 28901.0 4406.8 37683.0
Max. operating case
Pressure bar.a 124.19 120.46 25.73 26.26
Temperature deg.C 520.7 519.0 305.2 305.8
Mass flow rate t/h 166.2 498.6 160.1 480.3
Density kg/㎥ 37.26 36.14 10.30 10.52
Momentum m´2/ρ 741.3 6879.5 2487.0 21932.4
2.45 4.20 1.77 1.72
Cleaning Force Ratio > 1.0
OK OK OK OK
HRH HRH LP LP
UOM
(Each) (Common) (Each) (Common)
Flushing case
Pressure bar.a 9.79 8.93 5.87 5.69
Temperature deg.C 329.1 326.3 259.3 258.9
Mass flow rate t/h 133.1 399.2 84.4 253.3
Density kg/㎥ 3.59 3.29 2.44 2.36
Momentum m´2/ρ 4930.9 48482.7 2926.7 27158.7
Max. operating case
Pressure bar.a 23.81 23.09 6.31 6.00
Temperature deg.C 513.3 513.0 288.4 288.0
Mass flow rate t/h 160.1 480.3 76.3 225.2
Density kg/㎥ 6.67 6.47 2.48 2.35
Momentum m´2/ρ 3841.1 35641.0 2348.7 21534.1
> 1.0 1.28 1.36 1.25 1.26
Cleaning Force Ratio
OK OK OK OK

Rev.1 21 of 22