GRUNDFOS DATA BOOKLET

Fire VIF, HSEF, HSAF, HSMF


Grundfos firefighting systems

Firefighting systems with electric-powered (50/60 Hz) or diesel-


powered pumps approved by FM and/or UL according to NFPA 20
Fire VIF, HSEF, HSAF, HSMF

1. NFPA standards 3 11. Controller 40


Table of contents

Introduction to the NFPA 3 Controller types 40


Overview of fire system 4 Electric controllers 40
Performance requirements 5 Diesel controllers 42

2. Certification 7 12. Diesel engine data 43


General 43
3. Test, inspection and alignment 8 Engine type 43
Test 8 Monitoring and control devices 43
Inspection 8 Starting system 44
Alignment 8 Coupling 44
Engine speed control 44
4. Product description 9 Engine cooling 44
Introduction 9 Engine exhaust 44
VIF pumps 9 Fuel arrangement 44
HSEF, HSAF, HSMF pumps 10 Ambient temperature 45
Model variants 11 Engine protection 45
Ventilation 45
5. Performance range 12
VIF, 2-pole, 50 Hz 12 13. Fuel tanks 46
VIF, 4-pole, 50 Hz 12 Description 46
VIF, 2-pole, 60 Hz 13 Sizing 46
VIF, 4-pole, 60 Hz 13 Construction 46
HSEF/HSMF, 2-pole, 50 Hz 14 Installation 46
HSEF/HSAF, 4-pole, 50 Hz 14 Technical data 48
HSEF/HSMF, 2-pole, 60 Hz 15 Accessories 48
HSEF, 4-pole, 60 Hz 15
HSMF, 4-pole, 60 Hz 16 14. Bare shaft pumps 49
HSEF/HSAF, 1470 rpm, diesel 16 VIF 49
HSEF/HSAF, 1760 rpm, diesel 17 HSEF 50
HSMF, 1760 rpm, diesel 17 HSAF 54
HSEF, 1900 rpm, diesel 18 HSMF 55
HSEF/HSMF, 2100 rpm, diesel 18 Flange dimensions 58
HSEF, 2350 rpm, diesel 19
HSEF, 2600 rpm, diesel 19 15. Curve charts 59
HSEF/HSMF, 2800 rpm, diesel 20 How to read the curve charts 59
HSEF/HSMF, 2950 rpm, diesel 20 Curve conditions 60
HSEF/HSMF, 3000 rpm, diesel 21
16. Performance curves 61
6. Nameplates 22 Overview 61
VIF - 50 Hz 62
7. Construction 23 VIF - 60 Hz 67
Sectional drawing, VIF 23 HSEF, HSAF, HSMF - 50 Hz 77
Material specification, VIF 23 HSEF, HSAF, HSMF - 60 Hz 98
Sectional drawing, HSEF 24 HSEF, HSAF, HSMF - diesel 146
Material specification, HSEF 24
Sectional drawing, HSAF 26
Material specification, HSAF 26
Sectional drawing, HSMF 27
Material specification, HSMF 28
Mechanical construction 29

8. Pump shaft rotation 32

9. Operating conditions 33
Location 33
Ambient temperature and altitude 33
Inlet pressure 33

10. Motor data 34


General 34
Motors for VIF 34
Motors for HSEF, HSAF and HSMF 37

2
Fire VIF, HSEF, HSAF, HSMF
1

1. NFPA standards

NFPA standards
Introduction to the NFPA FM Global
The National Fire Protection Association (NFPA) is an FM Global is a mutual commercial and industrial
international, non-profit organisation of fire safety property insurance and risk management organisation.
professionals. FM tests and approves industrial and commercial
The organisation creates and maintains minimum products in compliance with its own standards, or other
acceptable standards and requirements for fire nationally recognised requirements
prevention and suppression activities, training, The mark "FM APPROVED" indicates that the product
equipment and other life safety codes and standards. complies with the required standards. See fig. 2.
NFPA standards are typically revised every three years See the FM home page: www.fmglobal.com.
in order to keep guidelines updated and to prevent the
loss of life and property due to fire. Underwriters Laboratories
See the NFPA home page: www.nfpa.org. Underwriters Laboratories Inc. (UL) is an independent,
non-profit, product-safety testing and certification
NFPA 20 organisation.
VIF and HSEF bare shaft pumps comply with the NFPA UL does not "approve" any product. Rather it tests
20 Standard for the Installation of Stationary Fire product samples and permits acceptable products to
Pumps for Fire Protection. The standard covers carry the UL mark, as long as they remain in
systems for commercial, industrial and private conformity with the standards and with the samples
buildings. tested to those standards.

Standards approval process


Grundfos tests the pumps and fills in the application
TM06 0003 4613

forms for each individual pump size. We submit this


documentation to the FM:
• Expected pump performance, including total head,
power requirement and efficiency versus flow
Fig. 1 NFPA mark characteristics.
If different impeller diameters are used to obtain the
The pumps have been tested and certified by FM
rated head for the pump to be examined, complete
(Factory Mutual) Global and UL (Underwriters
details must be provided concerning performance
Laboratory) to comply with the requirements of the
specifications to be evaluated.
NFPA 20. Compliance with the requirements is
indicated by the FM and UL mark affixed to the pumps. • Calculations to determine shaft size, casing bolt
See fig. 2. size and anti-friction bearing life.
• General assembly drawings, a complete set of
manufacturing drawings, materials lists and physical
TM03 5369 3606

TM03 5392 3606

property specifications, expected marking format,


brochures, sales literature, specification sheets,
installation, operating and maintenance procedures.
When the application forms have been accepted, the
Fig. 2 FM and UL marks FM will attend the final test at the Grundfos premises.
When the evaluation of the test results is positive, the
Other NFPA standards FM will issue a certificate of compliance of the pump
These standards are also of relevance to the products with the standards specified.
described in this data booklet: When a pump component is replaced after the
• NFPA 13. Installation of sprinkler systems certificate of compliance has been issued,
• NFPA 25. Standard for the inspection, testing and representative samples of the pump may need to be
maintenance of water-based fire protection systems re-tested.
• NFPA 70. National Electrical Code.

3
1 Fire VIF, HSEF, HSAF, HSMF

Overview of fire system


NFPA standards

4 4
5

6 6 2
5 5

8
7 5 5
8
9 6 9

10

12
1b 1a

6
14
9 9

5
5 5
11

TM03 5471 1507


13

3 3
Fig. 3 Overview of fire system

Pos. Description Pos. Description


1a Fire pump, electrically powered (duty pump) 8 Check valve/non-return valve
1b Fire pump, diesel-powered (standby pump) 9 Pressure gauge
2 Jockey pump 10 Waste cone with sight glass
3 From supply tank 11 Discharge from relief valve
4 To system 12 Flowmeter
5 Valve 13 Discharge from test line
6 Expansion joint 14 Supply to jockey pump
7 Main pressure relief valve

4
Fire VIF, HSEF, HSAF, HSMF
1
System design Performance requirements

NFPA standards
A firefighting system typically consists of three pumps:
FM-approved pumps comply with requirements
one pressure pump (jockey pump) and two fire pumps,
concerning these features:
one duty pump and one pump on standby. Each of the
fire pumps is capable of achieving the required • flow rate versus pressure
performance. • closed-valve pressure
Systems with only one fire pump with a redundant • motor power rating.
power supply or more than two fire pumps are, Flow rate versus pressure
however, also seen.
The approval/listing of the pump is based on a certain
Operation rated flow rate, indicated by the solid line in the curve
The jockey pump maintains pressure in the system charts. The pump must be able to supply not less than
and compensates for any loss of pressure caused by 150 % of the rated flow rate (broken line) and still be
leaks and thus prevents the duty pump from starting able to provide at least 65 % of the total rated pressure
unnecessarily. The jockey pump has two pressure when operating at a suction lift of at least 4.6 m (15 ft)
levels: referred to water surface. See fig. 4 and the example
• a low pressure level to start the jockey pump below.
• a high pressure level to stop the jockey pump. p
[psi]
In case of further decrease of system pressure due to HSEF 6-12
60 100% 150% n nom = 1450 min-1
fire (i.e. sprinkler opens), the duty pump will start. ISO 9906 Annex A
/311
In case this pump fails to start or breaks down, the 50
standby pump will start. 44 100%
40
The duty and standby pumps are not powered by the
34
same source. This ensures that if one pump fails, for 30
60%
example due to fire damage, the other will operate.

TM06 1054 1514


20
The pumps are controlled by pressure sensors.
Although individually designed for the specific 10

installation, each fire unit must comply with the NFPA 0


standards. 0 200 400 600 800 1000 1200 1400 1600 Q [US GPM]

Fire pumps Fig. 4 Flow rate versus pressure


FM-approved and UL-listed Grundfos in-line and Example
split-case pumps are designed for the distribution of
water in automatic sprinkler and standpipe systems. The pump complies with a flow requirement of
They are operated in case of fire and during tests. 750 gpm (170 m3/h). At this flow rate, the pump
delivers a pressure of 44 psi (31 mH). To be
Materials FM-approved or UL-listed, the pump must comply with
Impeller, wear rings, guide or diffusion vane rings, these requirements:
lantern rings, bottoms of stuffing boxes, interior nuts,
Rated flow rate (100 %): 750 gpm (170 m3/h)
linings of stuffing box throats, glands, gland nuts and
Maximum flow rate supplied by the pump
drain plugs are made of material approved by the FM 1125 gpm (256 m3/h)
(150 %):
and UL. Rated pressure (100 %): 44 psi (31 mH)
Minimum pressure supplied by the pump
34 psi (24 mH)
(65 %):

At 150 % of the total rated flow rate, the pump delivers


a pressure of 34 psi (24 mH). This means that the
pump complies with the requirements.

5
1 Fire VIF, HSEF, HSAF, HSMF

Closed-valve pressure Example


NFPA standards

The closed-valve pressure must be at least 101 % and The maximum power required for this pump is 25 kW.
not higher than 140 % of the total rated pressure. If the motor service factor is 1, the minimum motor size
See fig. 5 and the example below. required will be 25/1 = 25 kW.
If the motor service factor is 1.15, the minimum motor
p
[psi] size required will be 25/1.15 = 21.7 kW.
65 140% HSEF 6-12
60 n nom = 1450 min-1

53 /311
ISO 9906 Annex A
Other system components
50

44 100% Electric motors


40

Grundfos electric-powered firefighting systems are


30
typically equipped with NEMA design B motors, used
for fire pump service. The applicable standard is UL

TM06 1115 1614


20

1004-5.
10

Insulation class Enclosure class


0
0 200 400 600 800 1000 1200 1400 1600 Q [US GP M] ODP IP23
F
TEFC IP54/55
Fig. 5 Closed-valve pressure
Note: IEC motors are available on request.
Example ODP and TEFC motor do not have a service factor
The curve shows a rated pressure of 44 psi (31 mH). larger than 1.15.
To be FM-approved or UL-listed, the pump must
Jockey pumps
comply with these requirements:
Grundfos CR pumps are used as jockey pumps,
Rated pressure (100 %): 44 psi (31 mH)
maintaining the pressure. Under normal conditions, the
Minimum closed-valve pressure (101 %): 44 psi (31 mH)
jockey pump will be activated by the low-pressure
Maximum closed-valve pressure (140 %): 61 psi (43 mH)
switch as a result of small leakages, or if one or more
The pump has a closed-valve pressure of 53 psi sprinklers are activated.
(37 mH). This means that the pump complies with the The jockey pump is not subject to any specific NFPA
requirements. requirements.
Motor power rating Control panel
The maximum motor current under any condition of The control panel for the fire pumps must comply with
pump load must not exceed the rated full-load current NFPA 20 requirements. In addition, the cabinet must
multiplied by the service factor, if any. Service factors be listed by UL and ULC and approved by the FM and
must be in accordance with the NEMA Standard MG-1. CSA.
To ensure that the motor is capable of operating the The control panel is painted with RAL 3002 (red) and
pump at any time, the NFPA demands that the housed in a NEMA type-2 drip-proof enclosure.
manufacturer determines the maximum power required The control panel is suitable for wall mounting or floor
at a certain duty range. The maximum power occurs mounting.
when there is no increase in power with an increase in
the flow rate. See fig. 6 and the example below.
P2
[kW]
30

25 /311

20
TM04 4647 1809

10

0
0 200 400 600 800 1000 1200 1400 1600 Q [US GPM]

Fig. 6 Motor power rating

6
Fire VIF, HSEF, HSAF, HSMF
2

2. Certification

Certification
FM certification numbers HSEF 6-14Q
J.I.1N5A8.AH
J.I. 3000331
Pump type FM approval no. J.I.1P4A5.AH
VIF 2.5-8 3045826 HSEF 6-16 J.I.0P6A1.AH
VIF 2.5-8M - 3038697
VIF 3-8 3048567 3013017
HSEF 6-16G
VIF 3-11 3048567 3038697
VIF 3-11M - J.I.1P9A8.AH
HSEF 6-16N
VIF 4-8G 3048567 3038697
VIF 5-7 3045826 HSEF 6 -17 3038697
VIF 5-11 3048567 J.I.0P6A1.AH
VIF 6-10 3045826 HSEF 6-18 J.I.0W6A5.AH (Ext)
VIF 8-16 - J.I.1P2A5.AH
VIF 8-16G 3045826 J.I.0P3A6.AH
HSEF 8-13
J.I.1P2A5.AH J.I.1N8A5.AH
HSEF 3-9 HSEF 8-14 3041409
J.I.2T3A3.AH (CL 40)
HSEF 3-9G J.I.1P2A5.AH J.I.0P3A6.AH
HSEF 8-15
J.I.1N5A8.AH J.I.1N8A5.AH
J.I.0P6A1.AH J.I.0P3A6.AH
HSEF 8-15A
HSEF 4-10 J.I.1Y8A5.AH J.I.1N8A5.AH
J.I.2T3A3.AH (CL 40) J.I.0P3A6.AH
HSEF 8-15G
3027512 J.I.1P4A5.AH
J.I.1P9A8.AH HSEF 8-17A J.I.0Y3A4.AH
HSEF 4-10G HSEF 8-17Q J.I.0Y3A4.AH
3027512
J.I.1Q4A3.AH HSEF 8-17SS J.I.1P2A5.AH
HSEF 4-11 HSEF 8-17W J.I.0Y3A4.AH
J.I.1N5A8.AH
HSEF 4-11G J.I.1N5A8.AH HSEF 8-17Wuc -
J.I.1P9A8.AH J.I.1P4A5.AH
J.I.0Q9A3.AH J.I.1Q4A3.AH
HSEF 4-12 HSEF 8-20
J.I.1K7A1.AH J.I.2R4A7.AH
J.I.2T3A3.AH (CL 40) J.I.1R0A8.AH(Ext)
HSEF 4-12hr - J.I.1P4A5.AH
J.I.1P4A5.AH HSEF 8-20G J.I.1Q4A3.AH
J.I.1P2A5.AH J.I.2R4A7.AH
HSEF 5-8 J.I.1M9A5.AH
J.I.1P1A7.AH
J.I.2T3A3.AH HSEF 10-16 J.I.2T3A3.AH
J.I.1Q4A3.AH J.I.3006973
HSEF 5-8N J.I.1P4A5.AH
J.I.1P2A5.AH
J.I.0P6A1.AH HSEF 10-20 J.I.1Z7A7.AH (1900)
HSEF 5-11 J.I.2T3A3.AH J.I.2R4A7.AH
3027512 26676
HSEF 5-11G J.I.0P6A1.AH HSAF 12-19G J.I.1C9A1.AH
J.I.0Q9A3.AH J.I.2Z0A7.AH
J.I.2T3A3.AH (CL 40) HSMF 4-5-2 17453
HSEF 5-12 J.I.0W6A5.AH (Ext) HSMF 4-11-2 J.I.0Y3A4.AH
J.I.1V3A2.AH HSMF 4-14-3 -
3038697 10693
HSEF 5-12hr - HSMF 5-7-2 J.I.2C0A0.AH
J.I.0P3A6.AH J.I.0X3A6.AH
HSEF 5-14 HSMF 5-13B-2 -
J.I.0W6A5.AH (Ext)
J.I.2R4A7.AH HSMF 5-16B-3 J.I.2Z1A4.AH
HSEF 5-14N HSMF 5-16B-3 low range J.I.2Z1A4.AH
3027512
HSEF 5-15 3051598 HSMF 5-16B-3 high range -
J.I.1M6A2.AH HSMF 5-16B-3 LR J.I.2Z1A4.AH
J.I.1N8A5.AH HSMF 5-16B-3 HR -
HSEF 6-10 HSMF 6-10-2 11299
J.I.2R4A7.AH
J.I.1K7A1.AH HSMF 8-15-2 -
J.I.0M0A7.AH HSMF 8-15-6 -
J.I.1Q4A3.AH
J.I.1N8A5.AH UL certification numbers
HSEF 6-12
J.I.1N5A8.AH
J.I.2T3A3.AH (CL 40) UL list no.
Pump type
3024553 USA Dubai Singapore Brazil
J.I.1Q4A3.AH VIF EX3732 - - EX15463
HSEF 6-14 J.I.1N5A8.AH HSEF, HSAF, HSMF EX570 EX15563 EX15166 EX6873
3013017
J.I.1N8A5.AH
HSEF 6-14G J.I.3006973
3013017

7
3 Fire VIF, HSEF, HSAF, HSMF

3. Test, inspection and alignment


Test, inspection and alignment

Test
Each fire pump manufactured and assembled by
Grundfos will undergo various tests.
Below is the list of tests which is carried out at the
factory before shipping:
• Performance test
Each fire pump is performance tested. Each pump's
performance of head and absorbed power against
flow is measured and recorded. A performance test
certificate from factory will be supplied with the
pump.
• Hydrostatic test
Hydrostatic pressure is tested for 5 minutes to 1.5
times the sum of the closed-valve pressure plus the
maximum permissible suction head (1.5 x (Pmax +
Pmax suction)), but not less than 250 psi. Test liquid
is water at 20 °C (68 °F).
This ensures there are no visible signs of fluid
leakage developed on any outside surface of the
test vessel while exposed to the test pressure.
A performance test certificate from factory will be
supplied with the pump.

Inspection
Each fire pump manufactured and assembled by
Grundfos will undergo various inspections.
Below is the list of inspections which are carried out at
the factory before shipping.
• In process and final inspection
In process and final inspection verifies
pre-assembly and post-assembly of firefighting sets.
Pre-assembly inspection verifies pump, motor
nameplate, bolts, gauges, valves, shaft keys and
couplings. Post-assembly verifies coupling and
coupling guard alignment and base bolt torque.
• Packing and pre-shipment inspection
Packing and pre-shipment inspection ensures that
the firefighting set matches with the order
requirement. It also ensures that paint coating and
packing label are properly done and that all the
documents are attached to the fire set.

Alignment
In a complete pump unit assembled and supplied from
factory, the coupling halves have been accurately
aligned. Alignment is made by inserting shims under
the pump and motor mounting surfaces, as required.

8
Fire VIF, HSEF, HSAF, HSMF
4

4. Product description

Product description
Introduction VIF pumps
This data booklet covers the VIF, HSEF, HSAF and The VIF pump is a vertical inline centrifugal pump.
HSMF pump range. The pumps have been tested and The drive unit is supported by the pump as the suction
certified by FM to comply with the requirements of the and discharge flanges are approximately on the same
NFPA 20 covering firefighting systems for commercial centerline. The pump has these features:
and private buildings.
• Cast iron pump housing, bronze impeller, carbon
Designations steel shaft, bronze shaft sleeves and wear rings.
• VIF is a fire pump set with a VIF pump and motor. • Shaft sealing is a packed type stuffing box with at
The unit can be incorporated into a fire system. least five rings of a suitable non-asbestos packing.
• HSEF (HSAF or HSMF) is a fire pump set with an The stuffing box is equipped with a lantern ring or a
HSEF (HSAF or HSMF) pump and motor mounted mechanical seal with Ni-resist stationary seat,
on a common base frame. The unit can be carbon washer, ethylene propylene flexible
incorporated into a fire system. members, brass metal parts and 18-9 stainless steel
spring.
Scope of delivery
• Dynamically balanced rotating parts according to
A complete VIF or HSEF pump set assembled and
ISO 1940, class 6.3; hydraulically balanced
supplied from factory typically comprises these
impellers.
elements:
• Integral stuffing box.
• a pump and motor mounted on a common base
plate/frame or on the pump (do not apply to VIF) • Limited space requirement.
• a standard coupling protected by a coupling guard • No pump coupling for alignment.
(HSEF only) • Established installation costs.
• a controller • Fast and simple installation.
• pressure gauges
• a circulation relief valve.
Grundfos offers a flowmeter as an accessory.
The flowmeter has been approved by FM or UL.
All fire pump sets are delivered to order.
Accessories
Grundfos supplies a number of fire pump set
accessories. Please contact your local Grundfos
representative regarding the accessories below:
• flowmeter
• main relief valve
• waste cone

TM06 0083 4813


• eccentric suction reducer
• concentric discharge reducer
• hose valve head
• hose valve head drain valve
• angle hose valve with cap-chain. Fig. 7 VIF in-line pump and motor mounted on a base
plate

9
4 Fire VIF, HSEF, HSAF, HSMF

HSEF, HSAF, HSMF pumps HSMF pumps


Product description

The HSMF pumps are horizontal, split-case multistage


Pump sets available centrifugal pumps. The pumps have these features:
HSEF, HSAF, HSMF pump sets are available in the • Cast iron pump casing, double-suction bronze
following versions: impeller, carbon steel shaft, bronze shaft sleeves
Flex unit: Pump and motor are mounted on the and casing wear rings.
base frame, and the controller is • Two sturdy, grease-lubricated, anti-friction bearings.
mounted on the wall. • Stuffing box is an integral part of the pump casing.
Compact unit: Pump, motor and controller are • Tested according to NFPA performance standard.
mounted on the base frame.

Note: Compact units with VIF pumps are only


available on request.

HSEF and HSAF pumps


The HSEF and HSAF pumps are horizontal, split-case
single-stage centrifugal pumps. The pumps have these
features:
• Double suction neutralises the axial thrust on shaft.
• Double volute neutralises the radial thrust on shaft,
O-rings and sleeves.

TM06 1317 2314


• Easy maintenance of the pump without removing
the motor and disturbing the pipe line.
• Grooved impeller rings improve the efficiency and
reduce damage due to abrasive materials.
Fig. 10 HSMF horizontal, split-case multistage centrifugal
• Available in both clockwise (CW) and counter- pump and motor mounted on a base frame
clockwise (CCW) rotations.
TM06 1316 2314

Fig. 8 HSEF horizontal, split-case single-stage


centrifugal pump and motor mounted on a base
frame
TM06 1530 2514

Fig. 9 HSAF horizontal, split-case pump and motor


mounted on a base frame

10
Fire VIF, HSEF, HSAF, HSMF
4
Model variants

Product description
The fire pump sets VIF and HSEF are available in the following model variants:

Features Standard Optional


• ANSI 125lb suction/250 discharge
Flange ANSI 125 lb suction/125 discharge • ANSI 250lb suction/250 discharge
• DIN adapter
Rotation Clockwise (CW) Counter-clockwise (CCW)
Pump Sealing (HSEF pumps) Stuffing box -
Sealing (VIF pumps) Stuffing box Mechanical seal
Shaft sleeve Bronze Stainless steel 416 grade
Certification UL/FM CE declaration certificate
Terminal block - Available for all NEMA motors
Insulated bearing - Available for all NEMA motors
Motors
Space heater - With space heater
Thermistor - With thermistor
Battery voltage 12 V 24 V
• 250 psi suitable for sea water cooling loop
250 psi standard (galvanised) cooling
Cooling loop • 250 psi 316 stainless steel
loop
• 400 psi high pressure cooling loop
Engine
• Weather proof enclosure
Enclosure -
• Sound attenuated enclosure
Battery Lead acid Nickel cadmium
Cooling system Heat exchanger type Radiator type
Enclosure NEMA 2 NEMA 12.3 R,4&4X
Voltage 50 Hz 380-415 V 220-230 V
440-480 V
Voltage 60Hz 380-400 V
220-240 V
Control panel
Diesel voltage 220-240 V 120 V
• 0-600 psi for fresh water
Pressure transducer 0-300 psi for fresh water • 0-300 psi for sea water
• 0-600 psi for sea water

11
5 Fire VIF, HSEF, HSAF, HSMF

5. Performance range
Performance range

VIF, 2-pole, 50 Hz
H p
[m] [psi]
VIF
200 2-pole, 50 Hz
Electric

150
100
5-11
90
120
80
70 100
60
80
50
3-11
60
40
6-10
50
30
40

30
20

20

15
10

TM06 0765 0914


10
200 300 400 500 600 700 800 1000 1200 1500
Q [US GPM]

46 50 60 70 80 90 100 200 Q [m³/h]

VIF, 4-pole, 50 Hz
H p
[m] [psi]
70 100 VIF
4-pole, 50 Hz
60 Electric
80
50
8-16G
60
40
50
30
40

30
20
8-16

20

15
10
12

10

5
TM06 0764 0914

4
200 300 400 500 600 700 800 1000 1200 1500 2000 3000 4000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 600 700 Q [m³/h]

12
Fire VIF, HSEF, HSAF, HSMF
5
VIF, 2-pole, 60 Hz

Performance range
+ S
>P@ >SVL@

9,)
SROH+]
(OHFWULF

 


 
 





 0  



*










TM06 0767 0914



             
4>86*30@

           4>PñK@

VIF, 4-pole, 60 Hz

H p
[m] [psi]
VIF
90 4-pole, 60 Hz
120 Electric
80

70 100
8-16

60
80

50
8-16G

60
40

50

30
40

30
20
TM06 0766 0914

20
200 300 400 500 600 700 800 1000 1200 1500 2000 3000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 Q [m³/h]

13
5 Fire VIF, HSEF, HSAF, HSMF

HSEF/HSMF, 2-pole, 50 Hz
Performance range

H p
[m] [psi]
400
HSEF/HSMF
2-pole, 50 Hz
HSMF 5-13B-2 Electric
300
200
HSMF 4-11-2
200
4-12 5-15
150
100 5-12 8-14
90
120
80 4-10 6-12
70 100
60
80
50 4-10G 5-11

60
40 5-8 6-10
50
30
40

30
20

20

15
10
12

TM06 0773 0914


10
200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 600 700 800 1000 Q [m³/h]

Note: Models without pump name are HSEF pump models.

HSEF/HSAF, 4-pole, 50 Hz

H p
[m] [psi]
HSEF/HSAF
150 4-pole, 50 Hz
100
Electric
90
120
80
70 100
8-20
10-20
60
80
6-16
50 8-20G HSAF
8-17A 12-19G
60
40
5-14
50
8-17Q
30
40 8-15G

30
20

20

15
10
TM06 0772 0914

10
200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000
Q [US GPM]

4650 60 70 80 90 100 200 300 400 500 600 700 800 1000 Q [m³/h]

Note: Models without pump name are HSEF pump models.

14
Fire VIF, HSEF, HSAF, HSMF
5
HSEF/HSMF, 2-pole, 60 Hz

Performance range
H p
[m] [psi]
400 600 HSEF/HSMF
500 2-pole, 60 Hz
HSMF 5-13B-2
Electric
300
400
HSMF 4-11-2

200 300
4-12/4-12hr
5-12
hr
200 5-12
6-12
100 150
3-9 4-10
90 3-9G
80 120
5-11G
70 100
60 4-10G
80
6-10
50 5-8N

40 60
50
30
40

20 30

5-8

20

10 15

12

TM06 0776 0914


10
200 250 300 400 500 600 800 1000 1500 2000 2500 3000 4000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 600 700 Q [m³/h]

Note: Models without pump name are HSEF pump models.

HSEF, 4-pole, 60 Hz

H p
[m] [psi]
HSEF/HSAF
200 4-pole, 60 Hz
Electric

8-20
150 8-20G
100 6-17 6-18
10-20
90 8-17
120 8-1
S S
80 6-16 7W 8-1 12-19G
6-16N uc 7A
70 100 6- 8-1
16 7W
5-14 G 6-1 8-17Q
60 4Q
80
8-1
50 5-14N 5G 10-16
8-15
60
40 4-11
6-14
50
8-
13

4-11G
30 6-14G
40
6-12

30
20

20

15
10
TM06 0774 0914

12
200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000
Q [US GPM]

4650 60 70 80 100 200 300 400 500 600 700 800 1000 Q [m³/h]

15
5 Fire VIF, HSEF, HSAF, HSMF

HSMF, 4-pole, 60 Hz
Performance range

+ S
>P@ >SVL@
+60)

 SROH+]
(OHFWULF
 



%+LJK5DQJH


 %/RZ5DQJH




%

 




 








TM06 0775 3614



         
4>86*30@

          4>PñK@

HSEF/HSAF, 1470 rpm, diesel

H p
[m] [psi]
HSEF/HSAF
150 1470 rpm
100
Diesel
90
120
80
70 100
10-20
60 8-20G
80
6-16
50 8-20 8- HSAF
17
8- SS 12-19G
17
60 A
40
5-14
50
8-17Q
30
40 8-15G

30
20

20

15
10

12
TM06 0777 0914

10
200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000
Q [US GPM]

4650 60 70 80 90 100 200 300 400 500 600 700 800 1000 Q [m³/h]

Note: Models without pump name are HSEF pump models.

16
Fire VIF, HSEF, HSAF, HSMF
5
HSEF/HSAF, 1760 rpm, diesel

Performance range
H p
[m] [psi]
HSEF/HSAF
1760 rpm
Diesel
200

6-17
150 8-20G
100 10-20
8-20
90
120 6-16
6-18
80 8-17SS HSAF
8 -1 8-17A 12-19G
70 100 8-17
7W
uc
5-14 6-16N W
60 8-17Q
80 6-16G
6-14Q
10-16
50 5-14N 8-1
5 G

60 8-15
40 4-11
6-14
50
4-11G 8-13
6-14G
30
40
6-12

30
20

20

15
10
12

TM06 0778 0914


10
200 300 400 500 600 800 1000 1500 2000 3000 4000 5000 6000 8000 10000
Q [US GPM]

4650 60 70 80 90 100 200 300 400 500 600 700 800 1000 Q [m³/h]

Note: Models without pump name are HSEF pump models.

HSMF, 1760 rpm, diesel

+ S
>P@ >SVL@
+60)

 USP
'LHVHO
 



%+5


 %/5
%+LJK5DQJH






  


 

 







TM06 0779 3614


           
4>86*30@

           4>PñK@

17
5 Fire VIF, HSEF, HSAF, HSMF

HSEF, 1900 rpm, diesel


Performance range

+ S
>P@ >SVL@
+6()
USP
 'LHVHO











 













TM06 0780 3614



                
4>86*30@

             4>PñK@

HSEF/HSMF, 2100 rpm, diesel

HSMF

TM06 0781 3614

Note: Models without pump name are HSEF pump models.

18
Fire VIF, HSEF, HSAF, HSMF
5
HSEF, 2350 rpm, diesel

Performance range
H p
[m] [psi]
300 HSEF
200 2350 rpm
Diesel
5-14 (2) 5-14 (3)

200 6-17

150
100
5-14
90
120
80
70 100
4-12
60
80
50

60
40
50

30
40

30
20

TM06 0782 0914


20
200 250 300 400 500 600 800 1000 1500 2000 2500 3000 4000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 600 700 Q [m³/h]

HSEF, 2600 rpm, diesel

H p
[m] [psi]
HSEF
200 2600 rpm
Diesel
5-14N
150
100
90
120
80
70 100 5-11

60 4-10
80
50 6-12

60
40
50
30
40

30
20

20

15
10
TM06 0783 0914

10
200 250 300 400 500 600 800 1000 1500 2000 2500 3000
Q [US GPM]

46 50 60 70 80 90 100 200 300 400 500 Q [m³/h]

19
5 Fire VIF, HSEF, HSAF, HSMF

HSEF/HSMF, 2800 rpm, diesel


Performance range

HSMF

TM06 0887 0914


Note: Models without pump name are HSEF pump models.

HSEF/HSMF, 2950 rpm, diesel

HSMF

HSMF

TM06 0888 3614

Note: Models without pump name are HSEF pump models.

20
Fire VIF, HSEF, HSAF, HSMF
5
HSEF/HSMF, 3000 rpm, diesel

Performance range
HSMF

HSMF

TM06 0889 3614


Note: Models without pump name are HSEF pump models.

21
6 Fire VIF, HSEF, HSAF, HSMF

6. Nameplates
Nameplates

12 1 2 3 4 5 6 7 13

TM06 0002 4613


8 9 10 11

Fig. 11 Nameplate, VIF in-line pumps

12 1 2 3 4 5 6 7 13
TM06 0001 4613

8 9 10 11
Fig. 12 Nameplate, HSEF, HSAF, HSMF horizontal
split-case pumps

Pos. Description
1 Model
2 Rated capacity
3 Impeller number
4 Impeller diameter
5 Rated pressure
6 Serial number
7 Rated speed
8 Net pressure at 150 % rated capacity
9 Maximum pressure
10 Maximum absorbed power
11 Maximum suction pressure
12 FM approval
13 UL listing

22
Fire VIF, HSEF, HSAF, HSMF
7

7. Construction

Construction
Sectional drawing, VIF

TM06 0006 4713


Fig. 13 Sectional drawing, VIF pump

Material specification, VIF


Bronze fitted pump Iron fitted pump
Pos. Description
Material Material code ASTM Material Material code ASTM
1 Casing Cast iron - Class 30 A 48 Cl 30 Cast iron - Class 30 A 48 Cl 30
2 Impeller Nickel, aluminium, bronze B148 Cast iron A48 Cl 30 / A48 Cl 25
6 Shaft (motor manufacture) (motor manufacture) (motor manufacture) (motor manufacture) (motor manufacture)
7 Casing ring Bronze Steel A-36-81a
143-184JP Graphite braided ACR Graphite braided ACR
13 Packing ring
213-364JP PTFE synthetic packing PTFE synthetic packing
14 Shaft sleeve Bronze OPT 416 stainless steel A582 condition A
17 Packing gland Cast iron A743 grade CF-8 Cast iron A743 grade CF-8
17b Gland bolt or stud Steel A-36-81a Steel A-36-81a
17c Gland bolt nut Plated steel A194 grade 8M Plated steel A194 grade 8M
17d Gland bolt washer Plated steel A-36-81a Plated steel A-36-81a
26 Impeller lock screw Nylon/18-8 stainless steel F593 Nylon/18-8 stainless steel F593
26a Impeller lock washer Nylon/plated steel F594 Nylon/plated steel F594
27 Adapter ring Bronze Steel A-36-81a
29 Lantern ring (optional) TFE polymer TFE polymer
32 Impeller key Steel A108 or A26 Steel A108 or A26
40 Deflector (motor manufacture) (motor manufacture) (motor manufacture) (motor manufacture) (motor manufacture)
53 Casing support Cast iron - Class 30 A 48 Cl 30 Cast iron - Class 30 A 48 Cl 30
71 Adapter Cast iron - Class 30 A 48 Cl 30 Cast iron - Class 30 A 48 Cl 30
73 Casing gasket Fibre vegetable (vellumoid) F104 Fibre vegetable (vellumoid) F104
83 Stuffing box Cast iron - Class 30 A 48 Cl 30 Cast iron - Class 30 A 48 Cl 30
119 O-ring Viton Viton

23
7 Fire VIF, HSEF, HSAF, HSMF

Sectional drawing, HSEF


Construction

18 43 33 40A 29 127 14 31 2 1B 7 14A 14B 169 16 41 32 73B 35

73B 40B

37
6
123
46

18A
47

169
40A
17
17B

TM06 1061 1514


1A 8 63 13

Fig. 14 Sectional drawing, HSEF pump

Material specification, HSEF


Bronze fitted pump 316L stainless steel pump
Pos. Description
Material Material code ASTM Material Material code ASTM
1A, 1B Upper and lower casing Cast iron - Class 35 A48 Cl35 316L cast stainless steel A743 grade CF3M
2 Right hand impeller Nickel, aluminum, bronze B148 316L cast stainless steel A743 grade CF3M
6 Pump shaft Steel A193 416 stainless steel A582 type 416
7 Casing ring Bronze 316 stainless steel A276 type 316
8 Impeller ring (optional) Bronze 416 stainless steel A582 type 416
13 Packing ring PTFE synthetic packing PTFE synthetic packing
14A, 14 Left and right shaft sleeve Bronze 316 Stainless steel A276 type 316
14B Shaft sleeve O-ring Buna-N rubber Buna-N rubber
16 Inboard ball bearing Assembly Assembly
17 Packing gland 304 stainless steel A743 304 stainless steel A743
17A Gland clip (when used) 304 stainless steel A743 304 stainless steel A743
17B Gland bolt Steel A-36-81a Steel A-36-81a
18 Outboard ball bearing Assembly Assembly
18A Bearing-retaining ring Zinc plated steel A165 Zinc plated steel A165
29 Lantern ring (optional) Glass filled teflon Glass filled teflon
31 Impeller key Cast iron - Class 30 A48 Cl30 Cast iron - Class 30 A48 Cl30
32 Inboard bearing housing 316 stainless steel A582 303 stainless steel A582 type 303
33 Outboard bearing housing Cast iron - Class 30 A48 Cl30 Cast iron - Class 30 A48 Cl30
35 Inboard bearing housing cover Cast iron - Class 30 A48 Cl30 Cast iron - Class 30 A48 Cl30
37 Outboard bearing housing cover Cast iron - Class 30 A48 Cl30 Cast iron - Class 30 A48 Cl30
40A Inboard deflector Rubber Rubber
40B Outboard deflector Rubber Rubber
41 Inboard bearing housing cap Cast iron - Class 30 A48 Cl30 316L cast stainless steel A743 grade CF3M
43 Outboard bearing housing cap Cast iron - Class 30 A48 Cl30 316L cast stainless steel A743 grade CF3M
46 Coupling key Carbon steel A108 Carbon steel A108
47 Inboard bearing cover seal Rubber Rubber
63 Stuffing box bushing Stainless steel A582 Stainless steel A582
73A Casing gasket (not shown) Fibre vegetable (vellumoid) F104 Fibre vegetable (vellumoid) F104
73B Bearing cover gasket Fibre vegetable (vellumoid) F104 Fibre vegetable (vellumoid) F104
123 Bearing end cover Steel A-36-81a Steel A-36-81a
127 Water-seal piping (optional) Copper w/brass fittings Copper w/brass fittings
169 Bearing housing seal Rubber Rubber

24
Fire VIF, HSEF, HSAF, HSMF
7

Construction
18 43 33 40A 29 127 14 31 2 1B 7 14A 14B 169 16 41 32 73B 35

73B 40B

37
6
123
46

18A
47

169
40A
17
17B

TM06 1061 1514


1A 8 63 13

Fig. 15 Sectional drawing, HSEF pump

Continued table
CD4MCu duplex stainless pump
Pos. Description
Material Material code ASTM
1A, 1B Upper and lower casing CD 4MCuN duplex cast stainless steel A890 grade 1B
2 Right hand impeller CD4MCuN duplex cast stainless steel A890 grade 1B
6 Pump shaft 416 stainless steel A582 type 416
7 Casing ring 2205-Duplex A479 2205
8 Impeller ring (optional) 416 stainless steel A582 type 416
13 Packing ring PTFE synthetic packing
14A, 14 Left and right shaft sleeve 2205-Duplex A479 2205
14B Shaft sleeve O-ring Buna-N rubber
16 Inboard ball bearing Assembly
17 Packing gland 304 stainless steel A743
17A Gland clip (when used) 304 stainless steel A743
17B Gland bolt Steel A-36-81a
18 Outboard ball bearing Assembly
18A Bearing-retaining ring Zinc plated steel A165
29 Lantern ring (optional) Glass filled teflon
31 Impeller key Cast iron - Class 30 A48 Cl30
32 Inboard bearing housing A890
33 Outboard bearing housing Cast iron - Class 30 A48 Cl30
35 Inboard bearing housing cover Cast iron - Class 30 A48 Cl30
37 Outboard bearing housing cover Cast iron - Class 30 A48 Cl30
40A Inboard deflector Rubber
40B Outboard deflector Rubber
41 Inboard bearing housing cap CD 4MCuN duplex cast stainless steel A890 grade 1B
43 Outboard bearing housing cap CD4MCuN duplex cast stainless steel A890 grade 1B
46 Coupling key Carbon steel A108
47 Inboard bearing cover seal Rubber
63 Stuffing box bushing Stainless steel A582
73A Casing gasket (not shown) Fibre vegetable (vellumoid) F104
73B Bearing cover gasket Fibre vegetable (vellumoid) F104
123 Bearing end cover Steel A-36-81a
127 Water-seal piping (optional) Copper w/brass fittings
169 Bearing housing seal Rubber

25
7 Fire VIF, HSEF, HSAF, HSMF

Sectional drawing, HSAF


Construction

69A 18 41 73B 35 40A 17B 29 14 7 127 2 1B 8 32 63 13 14B 17 20 68 16 31 46

22
6

33

TM06 1278 2014


1A

Fig. 16 Sectional drawing, HSAF pump

Material specification, HSAF


Pos. Description Material Material code ASTM
1A, 1B Upper and lower casing Cast iron A48 class 40
2 Impeller Nickel, aluminium, bronze B148
4140 steel A193 grade
6 Pump shaft 300 series stainless steel (optional) RF
416 stainless steel (optional) RF
7 Casing ring Bronze
8 Impeller ring Bronze
13 Packing ring Graphited TFE
Bronze
14 Shaft sleeve 416 stainless steel (optional) A582 condition A
416 hardened stainless steel (optional) A582 condition A
14B Shaft sleeve O-ring Buna-N rubber
16 Inboard ball bearing Assembly
17 Assembly gland 304 stainless steel A743
17B Gland bolt Steel A-36-81a
18 Outboard ball bearing Assembly
Bronze
Sleeve nut R. H
416 stainless steel (optional) A582 condition A
20
Bronze
Sleeve nut L. H.
416 stainless steel (optional) A582 condition A
22 Bearing locknut Steel A-36-81a
29 Lantern ring Glass filled teflon
Steel A108
31 Impeller key
Stainless steel (for stainless steel shaft) A276
32 Inboard bearing housing Cast Iron A48 class 30
33 Outboard bearing housing Cast Iron A48 class 30
35 Bearing cover Cast Iron A48 class 30
40A Set screw - deflector 18-8 stainless steel
41 Casing assembly Cast iron A48 class 40
46 Coupling key Steel A108
63 Stuffing box bushing Stainless steel
68 Shaft collar Steel A-36-81a
69A Bearing lock washer Steel A-36-81a
73A Casing gasket (not shown) Vegetable fibre F104
73B Bearing housing gasket Vegetable fibre D1170
127 Seal piping Copper w/brass fittings

26
Fire VIF, HSEF, HSAF, HSMF
7
Sectional drawing, HSMF

Construction
TM06 1272 2014
Fig. 17 Sectional drawing, HSMF pump, type 1

TM06 1281 2014


Fig. 18 Sectional drawing, HSMF pump, type 2

35 41 16 31 40
69A 18 68 73B 40A

6
17B 1B 63 2 113 2A 7A 29 14
17 127 7 128 58 32 14B 13 46
22

33

1A
TM06 1280 2014

Fig. 19 Sectional drawing, HSMF pump, type 3

27
7 Fire VIF, HSEF, HSAF, HSMF

Material specification, HSMF


Construction

Pos. Description Material Material code ASTM


1A, 1B Upper and lower casing Cast iron - Class 35 A48 Cl 35
2A, 2 Left and right hand impeller Nickel, aluminium, bronze B148
6 Pump shaft Steel A193
7A, 7 Left and right hand casing ring Bronze
13 Packing PTFE synthetic packing
14 Shaft sleeve Bronze
14B Shaft sleeve O-ring Buna-N rubber
16 Inboard bearing Assembly steel
17 Packing gland 304 stainless steel A743
17B Gland bolt Steel A-36-81a
18 Outboard bearing Assembly steel
22 Bearing locknut Steel A-36-81a
29 Lantern ring Glass filled teflon
31 Inboard bearing housing Cast iron - Class 30 A48 Cl30
32 Impeller key Steel A276
33 Outboard bearing housing Cast iron - Class 30 A48 Cl 30
35 Bearing cover Cast iron - Class 30 A48 Cl 30
40 Water deflector Stainless steel A582 condition A
40A Set screw - deflector 18-8 stainless steel
41 Bearing cap Cast iron - Class 30 A48 Cl30
46 Coupling key Carbon steel A108
58 Interstage sleeve Aluminium, bronze B505
58A Interstage sleeve A Aluminium, bronze B505
63 Stuffing box bushing Stainless steel A582 condition A
68 Shaft collar Steel A-36-81a
69A Bearing lock washer Steel A-36-81a
73A Casing gasket (not shown) Fibre vegetable (vellumoid) F104
73B Bearing cover gasket Fibre vegetable (vellumoid) F104
113 Interstage bushing Bronze
127 Seal piping Copper w/brass fittings
128 Interstage sleeve key Steel A108

28
Fire VIF, HSEF, HSAF, HSMF
7
Mechanical construction Motor adaptor

Construction
VIF
Pump housing
The motor adaptor is made of cast iron, 040.
VIF The motor adaptor fits the NEMA frame up to 365 JP.
It has an integral stuffing box.and holes for flush lines.
The cast iron volute pump housing has an axial suction
port and axial discharge port. The flange dimensions
are according to ANSI16.1.
The pump housing has a drain hole closed by plugs.

TM06 0031 4713


TM06 0004 4613
Fig. 22 Motor adaptor, VIF

Bearing bracket and shaft


Fig. 20 Pump housing, VIF HSEF
The bearing bracket has two sturdy, anti-friction,
HSEF
grease-lubricated bearings.
The cast iron volute pump housing has a radial suction The bearing bracket supports are cast integral with the
and discharge port. The flange dimensions are lower casing half for permanent alignment of bearings
according to ANSI 16.1. and all rotating parts. The material is as minimum
The pump housing has a priming hole and a drain hole class-35 cast iron.
closed by plugs. The shaft is made of steel, ASTM A193.
A rubber deflector on the shaft prevents water from
entering the bearing bracket.
TM06 0017 3514

Fig. 21 Pump housing, HSEF TM03 4598 2306

Fig. 23 Bearing bracket and shaft, HSEF

29
7 Fire VIF, HSEF, HSAF, HSMF

Stuffing box Impeller


Construction

The stuffing box is sealed with braided packing rings. The closed impeller in the VIF pump is made of bronze
The braided material ensures a long service life of the and has double-curved blades with smooth surfaces
packing rings and protects the pump shaft (sleeve). for high efficiency.
The packing rings are fitted symmetrically with parallel
faces to prevent tilting. The packing ring joints are
alternately staggered to aid sealing. The upper casing

TM06 0077 4813


can be removed and allows for ease of inspection and
service of the stuffing box.
Packing ring materials
PTFE-impregnated fibre packing rings and EPDM Fig. 27 Impeller for a VIF pump
O-rings in the pump housing.
The impeller of the HSEF pump is dynamically
Barrier fluid balanced together with the shaft. The HSEF
VIF and HSEF pumps use internal barrier fluid. See fig. double-suction pump is hydraulically balanced which
24. compensates for the axial thrust. See fig. 28.

TM06 0005 4613


Fig. 28 Double-suction impeller for an HSEF pump

The direction of rotation of the impeller is clockwise


TM06 0078 4813

when viewed from the motor.


Note: HSEF pumps with counter-clockwise rotation are
available on request.
The impeller is adapted to the duty point required by
Fig. 24 Sectional view of uncooled stuffing box with
the customer by trimming the impeller.
internal barrier liquid

Coupling
Electrical-powered HSEF pumps are available with
flexible couplings:
TM06 0047 4713

Fig. 25 ISO grid coupling


TM06 0048 4713

Fig. 26 Exploded grid coupling

The split-case construction of the HSEF pump enables


removal and dismantling of the internal pump parts,
e.g. bearings, wear rings, impeller and packing rings
without disturbing the motor or pipework.

30
Fire VIF, HSEF, HSAF, HSMF
7
Foundation

Construction
Electrical-powered VIF pumps rest on a stand.
Vertical motors are directly coupled to the pump
impeller. See fig. 29.

TM06 0016 4713


Fig. 29 Schematic view of VIF

Electric-powered HSEF pumps and motors are


mounted on a common base frame. See fig. 30.
TM06 0015 4713

Fig. 30 Schematic view of HSEF, electric-powered

Diesel-powered HSEF pumps and motors are mounted


on a common base frame. See fig. 31.
TM06 0014 4713

Fig. 31 Schematic view of HSEF, diesel-powered

31
8 Fire VIF, HSEF, HSAF, HSMF

8. Pump shaft rotation


Pump shaft rotation

Pump shaft rotation must be correctly specified when


the fire pump system is ordered. The correct rotation
must be determined before attempting a piping layout
and design.
You determine the pumps shaft rotation as follows:
• if the top of the shaft revolves from the left to the
right, the rotation is right handed or clockwise (CW).
• if the top of the shaft revolves from the right to the
left, the rotation is left handed or counter-clockwise
(CCW).
Note: The rotation of a horizontal pump is based on
that the person standing at the driver end and facing
the pump. See fig. 32.

DNs DNd DNs

TM06 1030 1414

CCW CW

Fig. 32 Pump shaft rotation

32
Fire VIF, HSEF, HSAF, HSMF
9

9. Operating conditions

Operating conditions
Location
The pump set is designed for installation in a
non-aggressive and non-explosive atmosphere.
The relative air humidity must not exceed 95 %.

Ambient temperature and altitude


The ambient temperature must not exceed 40 °C
(104 °F).
If the ambient temperature exceeds 40 °C (104 °F), or
if the motor is installed more than 1000 metres
(3280 ft) above sea level, the motor must not be fully
loaded due to the low density and consequently low
cooling effect of the air. In such cases, it may be
necessary to use a motor with a higher output.
See fig. 33.

P1
[%]
100
90
80
70
60
TM00 2189 1003

50
20 25 30 35 40 45 50 55 60 65 70 75 80
t [°C]
1000 2250 3500 m

Fig. 33 Relationship between motor output (P2) and


ambient temperature/altitude

Inlet pressure
Maximum inlet pressure
The inlet pressure is limited by the maximum operating
pressure of the pump and the packing material.
Minimum inlet pressure
Refer to the latest National Fire Protection Association
pamphlet 20 (NFPA 20) for rules and exceptions.

33
10 Fire VIF, HSEF, HSAF, HSMF

10. Motor data


Motor data

General
Grundfos electric-powered firefighting systems are
equipped with NEMA design B motors, used for fire
pump service complying with the NFPA standards.
Note: Only NEMA motors are in compliance with the
NFPA standard.

Motors for VIF


The motors fully comply with federal motor efficiency
requirements as described in the Energy
independence and security act of 2007 also known as
EISA. All fire pump motors provide the nameplate data.

TM06 0908 1214

Fig. 34 Vertical motor

Features
• Class F insulation, Class B service factor
• rolled steel frame 180-320, cast iron frame on 360
• aluminium end shields 180-250, cast iron end
shields 280-360
• premasked Mylar nameplate 180-320, stainless
steel on 360
• 40 °C ambient, NEMA design, B performance on
60 Hz sine wave power
• regreasable bearings, 180 frame and larger
• double shielded bearings
• lifting provisions, 210 frame and larger
• suitable for star-delta, start 250 frame and larger
• dual voltage ratings suitable for part winding start
(PWS) on low voltage
• 575 V rating comply with NRCan standards
• oversized connection diagram, "CE" mark on
nameplate.

34
Fire VIF, HSEF, HSAF, HSMF
10
Motor range, 2-pole, 50 Hz

Motor data
Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: 40 °C
Insulation class: F
Enclosure class: IP23
Synchronous speed: 3000 rpm

Moment of inertia Weight Noise level Efficiency Full-load current


Output HP Frame size
[kg.m 2] [kg] [dB(A)] [%] [A]
7.5 213JP 0.0134 49.90 67 88.5 11.4
10 213JP 0.0134 49.90 67 86.5 14.8
15 215JP 0.018 63.50 67 86.5 21.5
20 256JP 0.0552 112.50 69 91.0 26.7
25 256JP 0.0552 112.50 69 88.5 34
30 284JP 0.1054 136.08 71 92.4 39
40 286JP 0.118 158.80 72 92.4 52.4
50 326JP 0.1606 174.60 73 93.0 65
60 364JP 0.1888 263.08 78 93.0 78.7
75 404JP 0.69531 369.60 76 94.5 93
100 404JP 0.69531 369.60 76 94.5 125

Motor range, 4-pole, 50 Hz


Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: 40 °C
Insulation class: F
Enclosure class: IP23
Synchronous speed: 1500 rpm

Moment of inertia Weight Noise level Efficiency Full-load current


Output HP Frame size
[kg.m2] [kg] [dB(A)] [%] [A]
7.5 213 0.0134 49.90 54 89.5 11
10 215 0.018 63.50 54 89.5 14.7
15 254 0.0447 108.90 63 91.0 22.2
20 284 0.1231 136.00 65 91.7 28.5
25 286 0.1644 158.80 62 93.0 34
30 286 0.1644 158.80 65 92.4 41
40 324 0.2929 174.60 63 93.0 54
50 364 0.4888 263.00 64 93.0 67
60 364 0.4888 263.00 65 94.1 82
75 365 0.55203 272.20 65 94.1 108
100 404 0.69531 274 66 94.5 131

35
10 Fire VIF, HSEF, HSAF, HSMF

Motor range, 2-pole, 60 Hz


Motor data

Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: 40 °C
Insulation class: F
Enclosure class: IP23
Synchronous speed: 3600 rpm

Moment of inertia Weight Noise level Efficiency Full-load current


Output HP Frame size
[kg.m2] [kg] [dB(A)] [%] [A]
7.5 184JP 0.0084 34.02 67 88.5 10.3
10 213JP 0.0134 49.90 67 88.5 14.6
15 215JP 0.018 63.50 67 89.5 20.7
20 254JP 0.0447 72.57 69 90.2 27.1
25 256JP 0.0552 113.40 69 91.0 33
30 284JP 0.1054 136.08 72 92.4 39
40 286JP 0.118 158.76 72 91.7 53
50 324JP 0.1281 174.63 74 92.4 67
60 326JP 0.1606 281.23 74 93.0 78
75 364JP 0.1888 263.08 78 93.0 98
100 365JP 0.2297 272.16 78 93.0 129

Motor range, 4-pole, 60 Hz


Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: 40 °C
Insulation class: F
Enclosure class: IP23
Synchronous speed: 1800 rpm

Moment of inertia Weight Noise level Efficiency Full-load current


Output HP Frame size
[kg.m2] [kg] [dB(A)] [%] [A]
7.5 213 0.0134 56.70 57 89.5 10.9
10 215 0.018 68.00 57 90.2 14.2
15 254 0.0447 108.90 64 91.7 21.8
20 256 0.0771 113.40 64 91.0 29.1
25 284 0.1231 136.08 65 91.7 35
30 286 0.1644 158.80 65 93.6 40
40 324 0.2929 174.60 64 93.6 53
50 326 0.3295 208.70 64 93.6 65
60 364 0.4888 263.00 66 94.1 80
75 365 0.55203 272.00 66 94.1 99
100 404 0.69531 401.00 68 94.5 130

36
Fire VIF, HSEF, HSAF, HSMF
10
Motors for HSEF, HSAF and HSMF Optional features

Motor data
Three phase - foot Mount and flange Mount • cable glands
High efficiency motors are specifically designed to • special voltages
meet or exceed all EISA 2007 requirements for energy • cast iron NEMA C-flange or D-flange (D-flange only
efficiency. They are certified by the Department of for frames 254T and up)
Energy with our Certificate of Compliance number • specially designed shaft
CC029A. • second shaft end
These fire pump duty (ODP) motors are designed for • thermistors, thermostats or RTDs (PT100)
environments where dirt and moisture are minimal and
• roller bearings on drive end
that provide maximum ventilation and heat dissipation.
These ODP motors are with design B torque and high • IEC metric frames (on request) for frame 160 up to
efficiency design from 143T through 449T frames. 280
• insulated bearings
• shaft grounding
• TEFC (total enclosed fan cooled).

Specific features
For frame 143/5T only
TM06 0909 1214
• Welded steel plate frames (welded feet)
• ZZ bearings (double shielded)
• degree of protection: IP21.
Fig. 35 Horizontal ODP electrical motor For frame 182/4T and 213/5T only
Below you see fire pump applications driven by VFD's • aluminium end shields and terminal box
10:1 speed range (6 to 60 Hz) and SF 1.15 fire pump • cooling system with finned rotor.
motor. For frame 254/6T and up
• cast iron frames
TM06 0900 1214

TM06 0901 1214

TM06 0902 1214

TM06 0903 1214

APPROVED BY
VERT
APPROVED BY
N • cast iron end shields and terminal box
ER
I

• cooling system with finned rotor


RA
TED E 104590 LR 38324 • regreasable bearings with positive pressure
lubrication system
Standard features • degree of protection: IP23.
• efficiency certification number CC029A according to
US Department of Energy Regulations for EISA
2007 efficiency levels
• 2 and 4 pole, 50/60 Hz
• voltage: 380-400-415 (D) V, 2-pole, 50 Hz
380-400 (YY) / 440-460 (D) V, 2-pole, 60 Hz
400 V, 4-pole, 50 Hz
380 V, 4-pole, 60 Hz
• open drip proof (ODP)
• NEMA dimensions
• NEMA design B ratings
• service factor: 1.15
• class F insulation for all frames, class B rise
• continuous duty (S1)
• ambient temperature: 50 °C, 2-pole
40 °C, 4-pole
• 1045 heat treated and stress relieved carbon steel
shaft
• motors are supplied with ball bearings as standard.
• F1 mounted (also available as flanged motors)
• paint: enamel alkyd resin base
• colour: red - RAL 3002
• NPT threaded terminal box
• at stainless steel nameplate - laser etched
• meets NEMA MG-1 Part 31 for inverter use at
1000:1 variable torque.

37
10 Fire VIF, HSEF, HSAF, HSMF

Motor range, 2-pole, 50 Hz


Motor data

Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: -20-50 °C
Synchronous speed: 3000 rpm
Insulation class: F
Enclosure class: IP23
Altitude: 1000 m
Duty: S1

Moment of inertia Weight Noise level Efficiency Rated current


Output HP Frame size
[kg/m2] [kg] [dB(A)] [%] [A]
15 254T 0.0319 93 66 89.5 20.6
20 256T 0.0431 102 66 90.2 27.3
25 284TS 0.0753 151 70 91 33.6
30 286TS 0.0941 151 70 91 39.7
40 324TS 0.1522 240 70 91.7 54.9
50 326TS 0.1734 256 72 92.4 67.2
60 364/5TS 0.2687 331 72 93 79.4
75 364/5TS 0.3107 352 78 93 97
100 404/5TS 0.4245 432 78 93 132
125 404/5TS 0.4737 455 81 93.6 156
150 444/5TS 1.05 685 85 93.6 193
200 444/5TS 1.18 664 85 94.5 257
250 444/5TS 1.31 694 85 94.5 317
300 447/9TS 1.38 825 85 94.5 338
350 447/9TS 1.81 970 85 95 441
400 447/9TS 2.07 1070 85 95 509

Motor range, 4-pole, 50 Hz


Standard: NEMA
Voltage: 400 V
Service factor: 1.15
Ambient temperature: -20-50 °C
Synchronous speed: 1500 rpm
Insulation class: F
Enclosure class: IP23
Altitude: 1000 m
Duty: S1

Moment of inertia Weight Noise level Efficiency Rated current


Output HP Frame size
[kg/m2] [kg] [dB(A)] [%] [A]
10 254T 0.06315 100 57 89.5 15.1
15 256T 0.07772 114 57 91 21.9
20 284T 0.11312 123 60 91 28.7
25 286T 0.13923 162 60 91.7 35.1
30 324T 0.21884 204 62 92.4 41.9
40 326T 0.24536 244 62 93 56.8
50 364/5T 0.50581 287 65 93 67.5
60 364/5T 0.65756 374 65 93.6 79.8
75 404/5T 0.74186 400 67 94.1 96.9
100 404/5T 0.92445 477 67 94.1 132
125 444/5T 1.35329 560 75 94.5 160
150 444/5T 1.77861 789 75 95 195
200 444/5T 2.31407 810 75 95 268
250 447/9T 2.62262 950 75 95.4 322
300 447/9T 3.08543 1050 75 95.4 378
350 447/9T 3.70252 1150 75 95.4 447

38
Fire VIF, HSEF, HSAF, HSMF
10
Motor range, 2-pole, 60 Hz

Motor data
Standard: NEMA
Voltage: 380 V
Service factor: 1.15
Ambient temperature: -20-50 °C
Synchronous speed: 3600 rpm
Insulation class: F
Enclosure class: IP23
Altitude: 1000 m
Duty: S1

Moment of inertia Weight Noise level Efficiency Rated current


Output HP Frame size
[kg/m2] [kg] [dB(A)] [%] [A]
15 254T 0.0319 93 66 89.5 21.5
20 256T 0.0431 102 66 90.2 28.7
25 284TS 0.0753 151 70 91 35.1
30 286TS 0.0941 151 70 91 41.7
40 324TS 0.1522 240 70 91.7 57.1
50 326TS 0.1734 256 72 92.4 69.9
60 364/5TS 0.2687 331 72 93 83.5
75 364/5TS 0.3107 352 78 93 102
100 404/5TS 0.4245 432 77 93 139
125 404/5TS 0.4737 455 84 93.6 164
150 444/5TS 1.05 685 85 93.6 203
200 444/5TS 1.18 664 85 94.5 271
250 444/5TS 1.31 694 85 94.5 334
300 447/9TS 1.38 825 85 95 378
350 447/9TS 1.81 970 85 95.4 460
400 447/9TS 2.07 1070 85 95.4 531

Motor range, 4-pole, 60 Hz


Standard: NEMA
Voltage: 380 V
Service factor: 1.15
Ambient temperature: -20-50 °C
Synchronous speed: 1800 rpm
Insulation class: F
Enclosure class: IP23
Altitude: 1000 m
Duty: S1

Moment of inertia Weight Noise level Efficiency Rated current


Output HP Frame size
[kg/m2] [kg] [dB(A)] [%] [A]
15 254T 0.06524 100 59 91 22.6
20 256T 0.07779 114 60 91 30.9
25 284T 0.11661 123 62 91.7 36.4
30 286T 0.14352 162 63 92.4 43.1
40 324T 0.22753 204 64 93 59.8
50 326T 0.24132 244 65 93 72.9
60 364/5T 0.5249 287 67 93.6 85
75 364/5T 0.68237 374 68 94.1 103
100 404/5T 0.76986 400 69 94.1 143
125 404/5T 0.87484 477 69 94.5 177
150 444/5T 0.14052 560 77 95 207
200 444/5T 1.84681 789 78 95 278
250 444/5T 2.24829 810 79 95.4 330
300 447/9T 2.93 1020 77 95.4 325
350 447/9T 3.27 865 77 95.5 380
400 447/9T 3.68 1150 77 95.6 453

39
11 Fire VIF, HSEF, HSAF, HSMF

11. Controller
Controller

Controller types
Electric-powered or diesel-powered VIF and HSEF
pumps use the following standard controller types:
• FTA 1100 (diesel)
• FTA 1000 (DOL)
• FTA 1300 (Y/D).
The controllers are UL listed and FM approved.
They meet the latest NFPA 20 and NFPA 70
requirements.
Note: Other controller types and manufacturers are
available on request.

Electric controllers
Electric controllers are available with the starting
methods below:
Motor full-load starting
Torque
Controller type Starting method current Advantages Disadvantages
[Nm]
[% of FLA]
Low costs
FTA 1000 DOL 600 100 High starting torque High starting current
Standard motors
Low starting current Power line transients
FTA 1300 Star-delta open 200 33
Medium starting torque Special motors
Low starting current
FTA 1350* Star-delta closed 200 33 Medium starting torque High costs
No line transients
150-50 % tap 25 Highest starting torque
FTA 1800* Auto transformer 252-65 % tap 42 Low starting current High costs
384-80 % tap 64 Standard motors
Soft start and stop
Reduced water hammer
FTA 1930* Solid state soft start 240-340 15 High costs
Redundant power circuit
Standard motors
FTA 1250* Part winding 390 42 Low costs Special motors
Standard motors High starting current
FTA 1500* Primary resistor 300 25
Low starting torque Resistive heating
Pressure limiting
Soft start and stop
High costs
FTA 3100/3130* VFD 100 100 Reduced water hammer
Large footprint
Redundant power circuit
Standard motors

* Available starting methods on request

40
Fire VIF, HSEF, HSAF, HSMF
11
Features • overvoltage message

Controller
• Voltage surge protector • NEMA type 2 (IEC IP22) enclosure
• main switch sized for connected motor horsepower • suitable for use as service equipment
and voltage • each standard controller comes with user set
• fire pump circuit breaker options for:
• single handle isolating disconnect switch/circuit – interlock alarm
breaker mechanism – low pressure audible alarm
• motor contactor – low suction alarm
• manual emergency mechanism to close the motor – pump run
contactor mechanically in an emergency condition – user defined input
• built-in start and stop push-buttons to bypass – weekly test.
automatic start circuits
• minimum run timer/off delay timer Technical data
• daylight saving time option
Enclosure class: NEMA type 2 - IP22
• weekly test timer
Operation: 200-600 VAC
• elapsed time meter
Short circuit current 100 kA RMS 350 Hp Less@ 380-415 V
• door mounted display/interface panel featuring a rating: 100 kA RMS 500 Hp Less@ 440-480 V
128 x 64 pixel backlit LCD graphical display, user
Operating temperature: 5-50 °C
control push-buttons and easy to read LED
indicators for:
Dimensions
– power available
– alarm
– normal transfer switch (if the unit is ordered with
an automatic power transfer switch)
– emergency transfer switch (if the unit ordered with
and automatic power transfer switch)
– system pressure low
– pump running
– deluge valve open
– remote start
– interlock on
– failure to start
– motor overload

TM06 0080 4813


– emergency isolation switch off (if the unit is
ordered with an automatic power transfer switch)
– phase failure
– phase reversal
– automatic shutdown disabled Dimensions
Motor size [mm] Weight
– overvoltage Type
[hp] [kg]
D2
– undervoltage W1 H1 HL* D1
(door open)
• digital pressure display 2.2 - 75 660 1565 305 305 876 125
FTA 1000
• USB host controller and port 92-147 737 1768 305 356 1003 152
FTA 1300
184-258 914 2032 - 457 1334 295
• solid state pressure transducer
* The HL dimension applies to panels supplied with legs.
• data log
Note: For other controller dimensions, please contact
• event log (3000 events) Grundfos.
• true RMS metering with simultaneous 3-phase
display of amps, volts, frequency, pressure and
alarm messages
• disk error message
• disk almost full message
• pressure error message
• motor over 320 % message
• local start message
• remote start message
• emergency start message
• failure to start message
• undervoltage message

41
11 Fire VIF, HSEF, HSAF, HSMF

Diesel controllers • 300 psi (20.7 bars) wet parts (solid state pressure
Controller

transducer, solenoid valve, plumbing) for fresh


The controllers - FTA 1100 are available with water applications
120/240 VAC input. They can be used with 12/24 VDC
• NEMA type 2 enclosure (IEC IP22)
engines.
• Each standard controller comes with user set
Features options for:
– AC power loss start
• AC line and battery circuit breakers
– interlock alarm
• manual-off-auto selector switch
– low pressure audible alarm
• manual test push-button
– low suction alarm
• two manual crank push-buttons
– main switch not in automatic position
• two 10 A battery chargers with four-stage charging
cycle, selectable AC voltage (110/220), selectable – manual test
DC voltage (12/24), and selectable battery type – pump run alarm
(lead acid, Ni-Cad 9/18 cell, Ni-Cad 10/20 cell) – remote start
• door mounted display/interface panel featuring a – user defined input
128 x 64 pixel backlit LCD graphical display, – weekly test setup
membrane type user control push-buttons and easy
– low pump room temperature
to read LED Indicators for:
– low reservoir
– AC power available
– relief valve open
– alarm
– high fuel level
– main switch in automatic position
– high reservoir.
– main switch in manual position
– low system pressure Technical data
– engine running
Enclosure class: NEMA type 2 - IP22
– engine fail to start
– high engine temperature Operation: Input 120/1 or 230/1

– low engine oil pressure Engine: 12/24 VDC

– engine overspeed Operating temperature: 5-50 °C

– engine alternate ECM (engine control module)


– malfunction of engine fuel injector
Dimensions
– low fuel level low
– automatic shutdown disabled
– malfunction of charger
– malfunction of battery 1
– malfunction of battery 2
• minimum run timer/off delay timer
• programmable daylight saving time option
• weekly test timer
• engine run time meter
• digital pressure display
TM06 0081 4813

• usb host controller and port


• solid state pressure transducer
• data log
• event log (3000 events)
• simultaneous display of battery voltages, charging
Dimensions
rates, AC volts, pressure and alarm messages [mm] Weight
Type
[kg]
• disk error message W1 H1 HL D1
• disk almost full message FTA 1100 665 914 305 300 91
• pressure error message
Note: The HL dimension applies to panels supplied
• failure to start message with legs.
• low suction pressure message
• crank cycle status indication (displays cranking
battery, number of starting attempts and crank/rest
time remaining)

42
Fire VIF, HSEF, HSAF, HSMF
12

12. Diesel engine data

Diesel engine data


General Junction box - integral with monitoring and control
panel, for DC wiring interconnections to engine cooler.
Diesel engines for firefighting pumps are of the
The engine requires these devices:
compression ignition type. The engines must be
approved/listed for the fire pump application. The mark • a regulator for regulating the engine speed within a
of the listing laboratory (FM and/or UL) is displayed on range of 10 % between shut-off and maximum load.
the engine nameplate showing compliance with the • an overspeed shut down device arrangement to
performance rating and functional requirements. shut down the engine at a speed approximately
The engines are rated according to the SAE conditions 20 % above the engine's rated speed.
of 29.61 inches (752.1 mm) Hg barometer and 77 °F • the engine must be an open type self contained
(25 °C) inlet air temperature (approximates 300 ft. power unit including the following equipment
(91.4 m) above sea level) by the testing laboratory – stub shaft
(see SAE Standard J 1349). – fuel pump and filters
– air cleaners
Engine type – lube oil pump
The diesel engine conforms to the requirement of the – lube oil filter
National Fire Protection Association, pamphlet 20 – exhaust flex connection
(NFPA 20). – fuel connections
The compression ignition diesel engine must be – starters.
approved/listed for fire pump services. • Each engine must be provided with two storage
Listed engine have an additional 10 % power reserve battery
of the pump's maximum requirement. Required gauges
• Tachometer - indicates rotations per minute.
Monitoring and control devices • Oil pressure gauge.
The monitoring and control devices on the engine are • Coolant temperature gauge.
shown in fig. 36. • Hour meter- records engine run time.
Additional gauges
XXXXXXXXX
TO START ENGINE 3 • Two voltmeters - one for each set of batteries.
1 1.Position MODE SELECTOR switch to MANUAL RUN.
2.Lift and hold MANUAL CRANK #1 until engine starts, or release

2
Battery charger
after 15 seconds. If unit fails to start, wait for 15 seconds,
use MANUAL CRANK #2 and repeat step.
3.If COOLING WATER is not flowing or engine TEMPERATURE is too HIGH,
open cooling system manual by-pass valve.
TO STOP ENGINE

There should be two means for recharging the storage


1.Push and hold MANUAL STOP until Engine Stops.
2.Return MODE SELECTOR switch to AUTOMATIC and MANUAL STOP position,
4 engine will stop.
3.Close cooling system manual by-pass valve.

batteries.
IMPORTANT
DO leave
NOT the MODE SELECTOR switch in the MANUAL RUN position
during AUTOMATIC operation.

OVERSPEED RESET
XXXXXXX 1.After problem has been corrected, reset the speed sensing device by
lifting the OVERSPEED RESET and hold for 30 seconds.

• The battery chargers in the diesel controller is the


5 6 7 8
primary source.
• The alternator on the engine is the secondary
TM03 5402 3606

9 10 11 12
source.
Engine rotation - clockwise, rotation viewed from heat
exchanger/front of engine.
Engines are to be used for stationary emergency
Fig. 36 Monitoring and control devices on the engine
standby fire pump services only. Engines are to be
tested in accordance with NFPA 25.
Pos. Description Pos. Description
Each engine is factory tested to verify power and
Tachometer (rpm) with
1
hour meter (run time)
7 Manual start contactor 2 performance.
2 Mode selector switch 8 Overspeed verification UL-FM power ratings are shown at specific speeds.
3
Manual operating
9 Engine oil pressure gauge The engine can be applied at a single rated rpm setting
instructions
± 50 rpm.
4 Warning light, red 10 Voltmeter for battery set 1
5 Overspeed reset switch 11 Voltmeter for battery set 2 The diesel engine is fully assembled and factory tested
6 Manual start contactor 1 12 Coolant temperature gauge by the engine manufacturer prior to shipment.

43
12 Fire VIF, HSEF, HSAF, HSMF

Starting system Engine exhaust


Diesel engine data

Each engine is provided with two storage battery units. Each engine must have an independent exhaust
Lead-acid batteries are used in dry charge conditions system.
with electrolyte liquid in a separate container. If the exhaust system exceeds 15 ft (4.5 m) in length,
Nickel-cadmium batteries can be used if they meet the the pipe size must be one pipe size larger than the
engine requirements. engine exhaust outlet size for each 5 ft (1.5 m) in
added length.
Coupling A flexible connection is used between the engine and
the exhaust pipe to provide thermal expansion and to
The engine is connected to the horizontal shaft pump isolate engine vibrations to the rest of exhaust run.
by means of a flexible coupling. The flexible coupling The flex connector must not be used for misalignment.
or flexible connecting shaft is directly attached to the The exhaust pipe must not be smaller in diameter than
engine flywheel adapter or stub shaft. the engine exhaust outlet and must be as short as
possible.
The exhaust pipe and silencer must be suitable for the
use intended, and the exhaust back pressure must not
exceed the engine manufacturer's recommendations.

TM06 0828 1014


A particularly high number of twists, bends, turns and
right angles could be described as having particularly
high back pressure. Always follow the NFPA 20
guidelines and the engine manufacturer's
recommendation. Exhaust pipes must be installed with
Fig. 37 Coupling
a clearance of at least 9 inches (229 mm) to
The engine can be connected to the pump by the drive combustible material.
shaft Exhaust pipes passing directly through combustible
roofs must be guarded at the point of passage by
ventilated metals thimbles that extend the pipes with at
TM06 0829 1014

least 9 inches (229 mm) above and 9 inches (229 mm)


below the roof construction and which are at least 6
inches (152 mm) larger in diameter than the exhaust
pipe.
Fig. 38 Drive shaft The exhaust system must be building-supported, not
engine-supported.

Engine speed control


Fuel arrangement
Engines are provided with a regulator capable of
regulating the engine speed within a range of 10 % Diesel fuel storage tanks preferably are to be located
between shut-off and maximum load condition of the inside the pump room or pump house, if permitted by
pump. local regulation. Diesel fuel supply tanks must be
located above the ground in accordance with municipal
The regulator is of the speed adjustable type, set and
or other authorities and in accordance with the
secured to maintain rated speed at maximum pump
requirements of the authority having the jurisdiction.
load
The fuel storage tank must not be buried.
The fuel tank must be sized for 1 gallon/Hp plus 10 %
Engine cooling (5 % expansion and 5 % for the sump)
The engine cooling system is of the closed circuit heat In areas with temperatures below 0 °C, the fuel tank
exchanger type. must be located in the pump room
Cooling water is piped through a threaded, rigid pipe The storage tank should be located so the fuel supply
from the pump discharge to the inlet of the heat pipe connection to the engine is no lower than the level
exchanger. The wastewater can be discharged into a of the engine fuel transfer pump.
visible, open waste cone or go back to a suction Fuel supply and return lines must be flame-resistant,
reservoir. reinforced flexible hoses.
Engines with radiator cooling are also available on
request for selected models.

44
Fire VIF, HSEF, HSAF, HSMF
12
Ambient temperature Ventilation

Diesel engine data


The ambient temperature must not exceed 25 °C For optimum room ventilation, the air supply ventilator
(77 °F). and air discharge must be located on opposite walls.
If the ambient temperature exceeds 25 °C (77 °F), or if The inlet louvre and ventilation system must ensure
the engine is installed more than 90 meters above sea that the temperature in the room does not exceed
level, the engine power must be derated according to 49 °C (120 °F) and supply adequate air for engine
figure x and y. combustion and for ventilated radiated heat from both
the engine and exhaust system.
P2
[%] Ventilation must be provided for the following
100 functions:
90 1. To control the maximum temperature to 49 °C
80 (120 °F) at the combustion air cleaner inlet with the
70
engine running at rated load.
60
2. To supply air for engine combustion.

TM06 0905 1214


3. To remove any hazardous vapour.
50
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 4. To supply and exhaust air as necessary for radiator
T [ O C]
cooling of the engine when required.
80 100 120 140 160 180 T [ O F]

Fig. 39 Relation between engine output (P2) and ambient


temperature

P2
[%]
100

90

80

70

60
TM06 0904 1214

50

TM06 0907 1214


0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
[m]

0 2000 4000 6000 8000 10000 12000 14000 [ft]

Fig. 40 Relation between engine output (P2) and altitude

Engine protection
The engine must be protected against possible
interruption of operation through explosion, fire, flood,
earthquake, freezing and other adverse condition.
The engine can be supplied with enclosures which
provide shelter from rain, wind borne debris and
control of unwanted pests.

45
13 Fire VIF, HSEF, HSAF, HSMF

13. Fuel tanks


Fuel tanks

Description
Firefighting systems running with a diesel engine must
be equipped with a suitable fuel tank, capable of
feeding the engine during 8 hours at full speed.
A range of a tank is available in different sizes,
including a range of tanks that are UL certified.

Sizing
The fuel tank must have a capacity that is at least
equal to 1 gallon per hp (5.07 l per kW), plus 10 %
(5 % expansion and 5 % for the sump).
For example, a 150 hp engine should be supplied with
a fuel tank of at least 165 gallons.

Construction
• The usual fuel volume is 90 % of the tank volume.
This will provide a sump volume of 5 % and an
expansion volume of 5 %.
• Dual wall version is available.
• The filling cap (pos. 1) can be padlocked closed and
the stopping cock (pos. 6) can be padlocked when
open.
• In order to conform to individual job requirements,
vent pipes and pipe lines must be furnished by
others.

Installation
• Diesel fuel storage tanks preferably are to be
located inside the pump room or pump house, if
permitted by local regulation.
• Diesel fuel supply tank must be located above
ground in accordance with municipal or other
authorities and in accordance with the requirements
of the authority having the jurisdiction. The storage
tank must not be buried.
• In areas with temperature below 0 °C, the fuel tank
must be located in the pump room.
• The supply tank should be located so the fuel
supply pipe connection to the engine is no lower
than the level of the engine fuel transfer pump.
• Fuel supply and return lines must be
flame-resistant, reinforced flexible hoses.
• The tank must be pitched 1/4" per foot (1.2 °) toward
the drain plug (pos. 7).

46
Fire VIF, HSEF, HSAF, HSMF
13

Fuel tanks
(3)
(4)

(15)
(10)
(13) H4
(14) (1-2)
(11) (8) (17)

(5) (9)

(12) - O2
d1 (5-6) - O1

H3
H2

TM06 0376 5313


(7)
d2 H1

(16)
W L1 L1
L2

Fig. 41 Fuel tank

Description
Pos. Designation Material
UL labeled Non UL labeled
1 Cap Iron Fill 2" (51 mm)
2 Strainer Steel Mesh 1/16" (1.5 mm)
3 Vent Steel 4" NPT weather resistant 2" NPT weather resistant
4 Bushing Iron - Pipe 2" x 1-1/4" NPT
5 Nipple Steel Pipe SCR 1/2" (13 mm) x close
Stop 1/2" (13 mm) for all fire pump engines /
6 Cock Brass
3/4" (19 mm) for Clarke engines DDFP-08FA & 08FH
7 Plug Iron Pipe 1" NPT
8 Tee Iron Pipe REDG 4" x 4" x 2" NPT Pipe REDG 1-1/4" x 1-1/4" x 1/2" NPT
9 Nipple Steel Pipe SCR 4" (102 mm) x close Pipe SCR 1-1/4" (32 mm) x close
10 Bushing Iron Pipe 2" x 1/2"NPT -
11 Tee Iron Pipe 1/2"NPT
12 Hose - Flex, swivel 1/2" NPT x 12" LG
13 Plug for low level fuel switch - -
14 Plug for fuel gauge - -
15 Vent pipe - -
16 Leg Steel -
17 Leak monitor - -

47
13 Fire VIF, HSEF, HSAF, HSMF

Technical data
Fuel tanks

Size Dimension [inch/mm]


[gal/l] L1 L2 H1 H2 H3 H4 W ∅d1 ∅d2
70 / 265 6 / 152 36 / 915 41 / 1041 2 3/4 / 70 65 / 1651 132 / 3353 17 / 432 24 / 610 1 / 25
115 / 435 15 / 381 60 / 1524 41 / 1041 2 3/4 / 70 65 / 1651 132 / 3353 17 / 432 24 / 610 1 / 25
140 / 530 15 / 381 72 / 1829 41 / 1041 2 3/4 / 70 65 / 1651 132 / 3353 17 / 432 24 / 610 1 / 25
200 / 757 15 / 381 60 / 1524 41 / 1041 3 1/4 / 82 73 / 1854 132 / 3353 22 1/2 / 571 32 / 813 1 / 25
250 / 946* 15 / 381 72 / 1829 41 / 1041 3 1/4 / 82 73 / 1854 132 / 3353 23 / 584 32 / 813 1 / 25
350 / 1325* 15 / 381 72 / 1929 41 / 1041 3 1/2 / 89 79 / 2007 132 / 3353 27 / 686 38 / 965 1 / 25
460 / 1741* 15 / 381 60 / 1524 41 / 1041 4 3/4 / 121 89 / 2261 132 / 3353 34 / 864 48 / 1219 1 / 25
550 / 8082* 15 / 381 72 / 1929 41 / 1041 4 3/4 / 121 89 / 2261 132 / 3353 34 / 864 48 / 1219 1 / 25
650 / 2460* 15 / 381 84 / 2137 41 / 1041 4 3/4 / 121 89 / 2261 132 / 3353 34 / 864 48 / 1219 1 / 25
830 / 3142* 15 / 381 60 / 1524 41 / 1041 5 3/4 / 146 105 / 2667 132 / 3353 45 / 1143 64 / 1626 1 / 25

Weight [lb/kg]
Size
Tank Total
[gal/l] Fuel
Single Dual Single Dual
70 / 265 422 / 192 247 / 112 495 / 225 669 / 303 917 / 416
115 / 435 690 / 313 297 / 135 595 / 270 987 / 448 1285 / 583
140 / 530 844 / 383 352 / 160 705 / 320 1196 / 543 1549 / 703
200 / 757 1205 / 547 370 / 168 740 / 336 1575 / 714 1945 / 883
250 / 946* 1507 / 684 387 / 176 775 / 352 1894 / 859 2282 / 1035
350 / 1325* 2110 / 957 472 / 214 945 / 429 2582 / 1171 3055 / 1386
460 / 1741* 2773 / 1258 587 / 266 1175 / 533 3360 / 1524 3948 / 1790
550 / 8082* 3385 / 1535 642 / 291 1285 / 583 4027 / 1827 4670 / 2119
650 / 2460* 3920 / 1778 742 / 337 1485 / 674 4662 / 2115 5405 / 2452
830 / 3142* 5004 / 2270 1107 / 502 2215 / 1005 6111 / 2772 7219 / 3275

* The tank is available for Clarke engines DDFP-08FA & 08FH.

Accessories
• Low level fuel switch (to be located on pos. 13).
• Fuel gauge (to be located on pos. 14).
∅d1 [inch/mm] Product number
24 / 610 2674451000
32 / 813 2674452000
38 / 965 2674453000
48 / 1219 2674454000
64 / 1626 2691156000

• Leg (to be located on pos. 16).


• Leak monitor (to be located on pos. 17).

48
Fire VIF, HSEF, HSAF, HSMF
14

14. Bare shaft pumps

Bare shaft pumps


VIF
s d

DNs DNd

h1

13 mm
14 mm

TM06 0906 2314


n2
n1

Fig. 42 VIF bare shaft pump

DNs DNd Pump [mm] Casing support [mm]


Weight
Pump type
[inch] h1 s d n1 n2 [kg]

VIF 2.5-8
2.5 2.5 220 216 203 254 226 51
VIF 2.5-8M
VIF 3-8 3 3 227 241 216 254 226 63
VIF 3-11
3 3 224 276 289 254 226 75
VIF 3-11M
VIF 4-8G 4 4 243 279 254 254 251 79
VIF 5-7 5 5 254 279 241 279 251 68
VIF 5-11 5 5 249 295 295 279 251 82
VIF 6-10 6 6 356 406 356 279 241 181
VIF 8-16
8 8 353 563 513 457 406 296
VIF 8-16G

49
14 Fire VIF, HSEF, HSAF, HSMF

HSEF
Bare shaft pumps

DNs DNd

TM06 1114 1614


Fig. 43 HSEF bare shaft pump

DNs DNd Pump [mm] Supporting feet [mm]


Pump type
[inch] w1 w2 h1 h2 s d hs hd ss dd qs qd n1 n2 n3 m1 m2 hf ∅c
HSEF 3-9
4 3 305 406 279 178 235 222 140 140 273 251 32 28 273 111 76 279 114 19 19
HSEF 3-9G
HSEF 4-10
5 4 305 406 279 200 279 279 165 165 311 298 35 32 368 152 86 330 140 25 19
HSEF 4-10G
HSEF 4-11
5 4 279 343 279 210 305 254 165 165 311 298 35 32 368 152 86 330 140 22 19
HSEF 4-11G
HSEF 4-12
5 4 305 406 330 219 318 260 165 197 311 330 35 32 368 152 86 330 140 25 19
HSEF 4-12hr
HSEF 5-8
6 5 327 416 279 168 305 305 146 146 292 286 25 24 368 152 86 330 140 25 19
HSEF 5-8N
HSEF 5-11
6 5 330 406 305 203 330 305 171 171 337 318 37 35 406 175 89 305 127 25 19
HSEF 5-11G
HSEF 5-12
6 5 330 406 356 246 356 330 203 216 368 362 37 35 400 175 86 305 127 25 19
HSEF 5-12hr
HSEF 5-14
6 5 343 438 330 244 330 356 178 216 324 362 25 35 476 210 86 381 165 25 19
HSEF 5-14N
HSEF 5-15 6 5 387 521 457 279 510 445 286 286 445 426 37 35 559 241 102 330 178 25 25
HSEF 6-10 8 6 330 406 356 206 330 260 191 171 368 337 28 37 368 152 86 330 140 25 19
HSEF 6-12 8 6 375 483 381 254 419 305 194 210 391 375 41 37 368 152 86 457 197 28 22
HSEF 6-14
HSEF 6-14G 8 6 349 445 381 279 406 368 229 241 425 406 41 37 476 210 86 432 191 25 19
HSEF 6-14Q
HSEF 6-16
HSEF 6-16G
8 6 381 476 381 289 406 457 232 273 409 438 28 37 476 203 86 432 191 25 19
HSEF 6-16N
HESF 6-17
HSEF 6-18 8 6 394 502 381 302 406 432 229 267 406 432 28 37 559 241 102 406 178 25 25

50
Fire VIF, HSEF, HSAF, HSMF
14

Bare shaft pumps


DNs DNd

TM06 1114 1614


Fig. 44 HSEF bare shaft pump

DNs DNd Shaft [mm]


db Keyway Weight
Pump type
[inch] [inch] l v [inch] [kg]

HSEF 3-9
4 3 1.37501) 95 51 0.312 x 0.156 113
HSEF 3-9G
HSEF 4-10
5 4 1.3750 1) 95 51 0.312 x 0.156 143
HSEF 4-10G
HSEF 4-11
5 4 1.12502) 60 51 0.250 x 0.125 116
HSEF 4-11G
HSEF 4-12
5 4 1.37502) 95 51 0.312 x 0.156 171
HSEF 4-12hr
HSEF 5-8
6 5 1.37502) 83 57 0.312 x 0.156 143
HSEF 5-8N
HSEF 5-11
6 5 1.56251) 70 51 0.375 x 0.188 172
HSEF 5-11G
HSEF 5-12
6 5 1.56251) 70 51 0.375 x 0.188 257
HSEF 5-12hr
HSEF 5-14
6 5 1.3750 2) 86 51 0.312 x 0.156 229
HSEF 5-14N
1)
HSEF 5-15 6 5 2.2500 133 102 0.500 x 0.250 535
HSEF 6-10 8 6 1.5625 1) 70 51 0.375 x 0.188 204
HSEF 6-12 8 6 1.87501) 102 76 0.500 x 0.250 340
HSEF 6-14
HSEF 6-14G 8 6 1.56251) 89 51 0.375 x 0.188 277
HSEF 6-14Q
HSEF 6-16
HSEF 6-16G
8 6 1.5625 1) 89 51 0.375 x 0.188 313
HSEF 6-16N
HSEF 6-17
HSEF 6-18 8 6 1.87501) 102 76 0.500 x 0.250 395
1) Tolerance: + 0.000 / - 0.001.
2)
Tolerance: + 0.0000 / - 0.0005.

51
14 Fire VIF, HSEF, HSAF, HSMF
Bare shaft pumps

DNs DNd

TM06 1114 1614


Fig. 45 HSEF bare shaft pump

Continued table
DNs DNd Pump [mm] Supporting feet [mm]
Pump type
[inch] w1 w2 h1 h2 s d hs hd ss dd qs qd n1 n2 n3 m1 m2 hf ∅c
HSEF 8-13 10 8 356 451 406 273 432 457 254 254 483 451 48 41 584 254 102 432 191 25 19
HSEF 8-14 10 8 483 610 483 305 425 330 270 270 492 460 48 41 457 191 89 483 210 32 22
HSEF 8-15
HSEF 8-15A 10 8 375 483 406 305 449 406 229 254 457 451 48 41 457 191 86 483 210 28 22
HSEF 8-15G
HSEF 8-17A
HSEF 8-17Q
HSEF 8-17SS 10 8 394 502 457 353 483 381 254 305 483 502 48 41 559 241 102 483 210 28 25
HSEF 8-17W
HSEF 8-17Wuc
HSEF 8-20
10 8 476 610 457 378 508 533 279 330 489 527 30 41 559 241 102 483 210 28 25
HSEF 8-20G
HSEF 10-16 12 10 476 610 457 340 533 419 279 305 527 514 32 30 559 241 102 559 241 28 25
HSEF 10-20 12 10 521 660 495 403 559 584 279 356 527 584 32 48 559 216 102 660 292 32 25

52
Fire VIF, HSEF, HSAF, HSMF
14

Bare shaft pumps


DNs DNd

TM06 1114 1614


Fig. 46 HSEF bare shaft pump

DNs DNd Shaft [mm]


db Keyway Weight
Pump type
[inch] [inch] l v [inch] [kg]

HSEF 8-13 10 8 1.56251) 89 51 0.375 x 0.188 341


HSEF 8-14 10 8 2.50001) 127 95 0.625 x 0.312 408
HSEF 8-15
HSEF 8-15A 10 8 1.87501) 102 76 0.500 x 0.250 386
HSEF 8-15G
HSEF 8-17A
HSEF 8-17Q
HSEF 8-17SS 10 8 1.87501) 102 76 0.500 x 0.250 458
HSEF 8-17W
HSEF 8-17Wuc
HSEF 8-20
10 8 2.25001) 124 102 0.500 x 0.250 603
HSEF 8-20G
HSEF 10-16 12 10 2.2500 1) 124 102 0.500 x 0.250 671
HSEF 10-20 12 10 2.5000 1) 127 95 0.625 x 0.313 907
1)
Tolerance: + 0.000 / - 0.001.
2) Tolerance: + 0.0000 / - 0.0005.

53
14 Fire VIF, HSEF, HSAF, HSMF

HSAF
Bare shaft pumps

TM06 1277 2014


Fig. 47 HSAF bare shaft pump

DNs DNd Pump [mm]


Pump type
[inch] w1 w2 h1 h2 s d hs hd ss dd qs qd
HSAF 12-19G 14 12 765 914 533 371 610 711 305 343 546 610 35 32

DNs DNd Supporting feet [mm] Shaft [mm]


db Keyway Weight
Pump type
[inch] n1 n2 n3 m1 m2 m3 m4 m5 hf øc [inch] l v [inch] [kg]

HSAF 12-19G 14 12 813 660 152 610 533 368 813 102 51 32 2.99901) 143 121 0.750 x 0.375 1489
1) Tolerance: + 0.000 / - 0.001.
2)
Tolerance: + 0.0000 / - 0.0005.

54
Fire VIF, HSEF, HSAF, HSMF
14
HSMF

Bare shaft pumps


l1
l

TM06 1276 2014


Fig. 48 HSMF bare shaft pump

DNs DNd Pump [mm]


Pump type
[inch] w1 w2 w3 w4 s d hs hd h h1 h2
HSMF 4-5-2 4 5 702 549 282 1153 356 356 140 229 - 305 355
HSMF 5-7-2 5 6 768 597 325 1267 406 406 152 254 1080 356 -
HSMF 5-13B-2 5 6 854 683 325 1422 381 381 178 222 1048 368 -
HSMF 6-10-2 6 8 943 727 381 1556 406 457 191 273 1165 406 -
HSMF 8-15-2
8 10 1086 845 419 1803 457 508 216 292 1340 457 -
HSMF 8-15-6

DNs DNd Supporting feet [mm] Shaft [mm]


db Keyway
Pump type
[inch] [inch]
[inch] n n1 n2 n3 n4 m m1 m2 p1 p2 hf ∅c l l1 v
1.750 1)
HSMF 4-5-2 4 5 616 210 362 83 324 457 206 76 22 60 51 19 121 108 83 0.375 x 0.188
1.749 2)
2.000 1)
HSMF 5-7-2 5 6 699 238 409 102 365 508 229 76 25 70 57 22 2) 121 108 83 0.50 x 0.25
1.999
2.250 1)
HSMF 5-13B-2 5 6 787 257 429 127 409 559 254 76 51 70 64 22 2) 152 127 102 0.50 x 0.25
2.249
2.250 1)
HSMF 6-10-2 6 8 876 279 495 127 445 610 276 89 51 102 57 25 152 127 102 0.50 x 0.25
2.249 2)
HSMF 8-15-2 2.750 1)
8 10 991 318 559 152 495 711 318 102 57 121 83 32 165 130 121 0.625 x 0.312
HSMF 8-15-6 2.749 2)

1) Tolerance: + 0.000 / - 0.001.


2)
Tolerance: + 0.0000 / - 0.0005.

55
14 Fire VIF, HSEF, HSAF, HSMF
Bare shaft pumps

l1

TM06 1283 2014


Fig. 49 HSMF bare shaft pump

DNs DNd Pump [mm]


Pump type
[inch] w1 w2 w3 w4 s d hs hd h h1 h3
HSMF 4-14-3 4 5 702 752 282 1356 356 356 140 229 1095 356 505
HSMF 5-16B-3
HSMF 5-16B-3 low range
HSMF 5-16B-3 high range 5 6 841 899 325 1626 406 406 152 273 1229 406 603
HSMF 5-16B-3 LR
HSMF 5-16B-3 HR

DNs DNd Supporting feet [mm] Shaft [mm]


db Keyway
Pump type
[inch] [inch]
[inch] n n1 n2 n3 n4 m m1 m2 mm1 mm2 p1 p2 pp1 pp2 hf ∅c l l1 v
1.750 1) 0.375 x
HSMF 4-14-3 4 5 819 397 346 353 302 508 229 102 273 216 38 83 311 51 140 22 121 108 83
1.749 2) 0.188
HSMF 5-16B-3
HSMF 5-16B-3 low
range
2.250 1) 0.50 x
HSMF 5-16B-3 5 6 946 451 394 451 343 610 276 89 318 248 51 102 406 57 152 25 152 127 102
2.249 2) 0.25
high range
HSMF 5-16B-3 LR
HSMF 5-16B-3 HR
1) Tolerance: + 0.000 / - 0.001.
2)
Tolerance: + 0.0000 / - 0.0005.

56
Fire VIF, HSEF, HSAF, HSMF
14

Bare shaft pumps


TM06 1284 2014
Fig. 50 HSMF bare shaft pump

DNs DNd Pump [mm]


Pump type
[inch] w1 w3 w2 w4 s d hs hd h1 h2
HSMF 4-11-2 4 6 759 362 572 1226 356 356 191 191 356 343

DNs DNd Supporting feet [mm] db Shaft [mm] Keyway


Pump type
[inch] n n1 n2 n3 m m1 m2 hf ∅c [inch] l v [inch]

1.7501)
HSMF 4-11-2 4 6 1,022 559 368 102 419 178 76 19 22 111 83 0.375 x 0.188
1.749 2)
1)
Tolerance: + 0.000 / - 0.001.
2)
Tolerance: + 0.0000 / - 0.0005.

57
14 Fire VIF, HSEF, HSAF, HSMF

Flange dimensions
Bare shaft pumps

DN

TM03 4591 2306


q
dz

Fig. 51 Flange

Flange dimensions, ASME/ANSI 125 lb

DNs Number Flange [mm]


[inch] of holes D K q dz
2 4 152 121 16 19
2.5 4 178 140 17 19
3 4 191 152 19 19
3.5 8 216 178 21 19
4 8 229 191 24 19
5 8 254 216 24 22
6 8 279 241 25 22
8 8 343 298 29 22
10 12 406 362 30 25
12 12 483 432 32 25
14 12 533 476 35 29

Flange dimensions, ASME/ANSI 250 lb

DNs Number Flange [mm]


[inch] of holes D K q dz
2 4 152 121 16 19
2.5 4 178 140 17 19
3 4 191 152 19 19
3.5 8 216 178 21 19
4 8 229 191 24 19
5 8 254 216 24 22
6 8 279 241 25 22
8 8 343 298 29 22
10 12 406 362 30 25
12 12 483 432 32 25
14 12 533 476 35 29

58
Fire VIF, HSEF, HSAF, HSMF
15

15. Curve charts

Curve charts
How to read the curve charts
Size of impeller QH curve of the individual pump

H p
[m] [psi]
110
160 /228.6 HSEF 3-9G
150 n nom = 3525 min-1
100 ANSI/HI 1.6-2000 Pump type and rated
140
/214.4 pump speed
90 130

120
80
110

70 100

90
60
80
50 70

60
40
50
30
40

20 30
The power curve
20 indicates pump input
power, P2, of the
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM] individual pump.

0 40 80 120 160 200 240 Q [m³/h]


P2 P2
[kW] [hp]
80 /228.6

50 70
/214.4
60
40
50
30 40

30
20
20
10
10
0 0
The eta curve indicates
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM] the pump efficiency of
Eff the individual pump.
[%]
80

70

60

50

40 /228.6
TM06 0358 4513

30 /214.4

20
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

59
15 Fire VIF, HSEF, HSAF, HSMF

Curve conditions
Curve charts

Selection of pumps
The guidelines below apply to the performance curves
shown in the curve charts, pages 62 to 243.
• Tolerances according to ANSI/HI 1.6-2000.
• The curves show pump performance with different
impeller diameters at the rated speed.
• The curves apply to the pumping of water at a
temperature of +20 °C (68 °F) and a kinematic
viscosity of 1 mm2/s (1 cSt).

Calculation of total head


The total pump head consists of the height difference
between the measuring points + the differential head +
the dynamic head.

H = H +H +H
total geo stat dyn

Hgeo: Height difference between measuring points.

Hstat: Differential head between the suction and the


discharge side of the pump.

Hdyn: Calculated values based on the velocity of the


pumped water on the suction and the
discharge side of the pump.
Note: Selection of the pump is based on the head
given by the customer.

Performance tests
The requested duty point of every pump is tested
according to ANSI/HI 1.6-2000. The curve of the
performance test is supplied with the pump.
If the customer requires either more points on the
curve to be checked or certain minimum performances
or certificates, individual measurements must be
made.

60
16

Performance curves
16. Performance curves
Overview
VIF HSEF, HSAF, HSMF

Pump type See page Pump type See page Pump type See page Pump type See page
50 Hz 50 Hz HSEF 10-16 133 HSEF 6-16, 1780 min-1 190
VIF 3-11 62 HSEF 4-10 77 HSEF 10-20 134 HSEF 6-16G, 1760 min-1 191
VIF 5-11 63 HSEF 4-10G 78 HSAF 12-19G 135 HSEF 6-16N, 1780 min-1 192
VIF 6-10 64 HSEF 4-12 79 HSMF 4-5-2 136 HSEF 6-17, 1760 min-1 193
VIF 8-16 65 HSEF 5-8 80 HSMF 4-11-2 137 HSEF 6-17, 2100 min-1 194
VIF 8-16G 66 HSEF 5-11 81 HSMF 4-14-3 138 HSEF 6-17, 2350 min-1 195
60 Hz HSEF 5-12 82 HSMF 5-7-2 139 HSEF 6-18, 1770 min-1 196
VIF 2.5-8 67 HSEF 5-14 83 HSMF 5-13B-2 140 HSEF 8-13, 1760 min-1 197
VIF 2.5-8M 68 HSEF 5-15 84 HSMF 5-16B-3 141 HSEF 8-14, 2950 min-1 198
VIF 3-8 69 HSEF 6-10 85 HSMF 5-16B-3 low range 142 HSEF 8-15, 1760 min-1 199
VIF 3-11M 70 HSEF 6-12 86 HSMF 5-16B-3 high range 143 HSEF 8-15A, 2100 min-1 200
VIF 4-8G 71 HSEF 6-16 87 HSMF 6-10B-2 144 HSEF 8-15G, 1470 min-1 201
VIF 5-7 72 HSEF 8-14 88 HSMF 8-15-6 145 HSEF 8-15G, 1780 min-1 202
VIF 5-11 73 HSEF 8-15G 89 Diesel HSEF 8-15G, 2100 min-1 203
VIF 6-10 74 HSEF 8-17A 90 HSEF 4-10, 2600 min-1 146 HSEF 8-17A, 1460 min-1 204
VIF 8-16 75 HSEF 8-17Q 91 HSEF 4-10, 2800 min-1 147 HSEF 8-17A, 1780 min-1 205
VIF 8-16G 76 HSEF 8-20 92 HSEF 4-10, 2950 min-1 148 HSEF 8-17Q, 1470 min-1 206
HSEF 8-20G 93 HSEF 4-10, 3000 min-1 149 HSEF 8-17Q, 1780 min-1 207
HSEF 10-20 94 HSEF 4-10G, 2950 min-1 150 HSEF 8-17Q, 2100 min-1 208
HSAF 12-19G 95 HSEF 4-10G, 3000 min-1 151 HSEF 8-17SS, 1460 min-1 209
HSMF 4-11-2 96 HSEF 4-11, 1760 min-1 152 HSEF 8-17SS, 1780 min-1 210
HSMF 5-13B-2 97 HSEF 4-11G, 1760 min-1 153 HSEF 8-17W, 1770 min-1 211
60 Hz HSEF 4-12, 2100 min-1 154 HSEF 8-17W, 2100 min-1 212
HSEF 3-9 98 HSEF 4-12, 2350 min-1 155 HSEF 8-17Wuc, 1780 min-1 213
HSEF 3-9G 99 HSEF 4-12, 2950 min-1 156 HSEF 8-17Wuc, 2100 min-1 214
HSEF 4-10 100 HSEF 4-12, 3000 min-1 157 HSEF 8-20, 1470 min-1 215
HSEF 4-10G 101 HSEF 5-8, 2950 min-1 158 HSEF 8-20, 1780 min-1 216
HSEF 4-11 102 HSEF 5-8, 3000 min-1 159 HSEF 8-20, 2100 min-1 217
HSEF 4-11G 103 HSEF 5-11, 2600 min-1 160 HSEF 8-20G, 1470 min-1 218
HSEF 4-12 104 HSEF 5-11, 2800 min-1 161 HSEF 8-20G, 1780 min-1 219
HSEF 4-12hr 105 HSEF 5-11, 2950 min-1 162 HSEF 8-20G, 2100 min-1 220
HSEF 5-8 106 HSEF 5-11, 3000 min-1 163 HSEF 10-16, 1775 min-1 221
HSEF 5-8N 107 HSEF 5-12, 2950 min-1 164 HSEF 10-16, 1900 min-1 222
HSEF 5-11G 108 HSEF 5-12, 3000 min-1 165 HSEF 10-20, 1470 min-1 223
HSEF 5-12 109 HSEF 5-14, 1460 min-1 166 HSEF 10-20, 1780 min-1 224
HSEF 5-12hr 110 HSEF 5-14, 1760 min-1 167 HSEF 10-20, 1900 min-1 225
HSEF 5-14 111 HSEF 5-14, 2100 min-1 168 HSAF 12-19G, 1480 min-1 226
HSEF 5-14N 112 HSEF 5-14, 2300 min-1 169 HSAF 12-19G, 1760 min-1 227
HSEF 6-10 113 HSEF 5-14, 2350 min-1 170 HSMF 4-5-2, 1760 min-1 228
HSEF 6-12 114 HSEF 5-14, 2400 min-1 171 HSMF 4-11-2, 2800 min-1 229
HSEF 6-14 115 HSEF 5-14N, 1760 min-1 172 HSMF 4-11-2, 2950 min-1 230
HSEF 6-14G 116 HSEF 5-14N, 2600 min-1 173 HSMF 4-11-2, 3000 min-1 231
HSEF 6-14Q 117 HSEF 5-15, 2950 min-1 174 HSMF 4-14-3, 1750 min-1 232
HSEF 6-16 118 HSEF 5-15, 3000 min-1 175 HSMF 5-7-2, 1760 min-1 233
HSEF 6-16G 119 HSEF 6-10, 2800 min-1 176 HSMF 5-7-2, 2100 min-1 234
HSEF 6-16N 120 HSEF 6-10, 2950 min-1 177 HSMF 5-13B-2, 2800 min-1 235
HSEF 6-17 121 HSEF 6-10, 3000 min-1 178 HSMF 5-13B-2, 2950 min-1 236
HSEF 6-18 122 HSEF 6-12, 1760 min-1 179 HSMF 5-13B-2, 3000 min-1 237
HSEF 8-13 123 HSEF 6-12, 2600 min-1 180 HSMF 5-16B-3 HR, 1775 min-1 238
HSEF 8-15 124 HSEF 6-12, 2800 min-1 181 HSMF 5-16B-3 LR, 1775 min-1 239
HSEF 8-15G 125 HSEF 6-12, 2950 min-1 182 HSMF 5-16B-3 high range, 1775 min-1 240
HSEF 8-17A 126 HSEF 6-12, 3000 min-1 183 HSMF 6-10-2, 1775 min-1 241
HSEF 8-17Q 127 HSEF 6-14, 1760 min-1 184 HSMF 8-15-2, 1770 min-1 242
HSEF 8-17SS 128 HSEF 6-14Q, 1760 min-1 185 HSMF 8-15-6, 1750 min-1 243
HSEF 8-17W 129 HSEF 6-14Q, 2100 min-1 186
HSEF 8-17Wuc 130 HSEF 6-14G, 1760 min-1 187
HSEF 8-20 131 HSEF 6-14G, 2100 min-1 188
HSEF 8-20G 132 HSEF 6-16, 1460 min-1 189

61
16
Performance curves

VIF - 50 Hz
VIF 3-11

H p
[m] [psi]
VIF 3-11
100 140 n nom = 2950 min-1
/266.7 ANSI/HI 1.6-2000
120
80

100 /228.6

60
80
/198.4
/184.2
60
40

40

20
20

0 0
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]

0 20 40 60 80 100 120 Q [m³/h]


P2 P2
[kW] [hp]
40
/266.7
25 35
30
20
25 /228.6

15 20

15 /198.4
10
/184.2
10
5
5
0 0
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]
Eff
[%]
70

60

50

40 /184.2 /198.4 /266.7


/228.6
30
TM05 9805 4513

20

10
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]

62
16

Performance curves
VIF 5-11

H p
[m] [psi]
180
/266.7 VIF 5-11
120 n nom = 2950 min-1
160 ANSI/HI 1.6-2000

100 140
/231.6

120
80
/203.2
100
/190.5
60
80

60
40

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]


P2 P2
[kW] [hp]
100
/266.7
60 80

60 /231.6
40

40 /203.2
/190.5
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]
Eff
[%]
80

70

60
/266.7
50
/231.6
40

30 /203.2
TM05 9806 4513

/190.5
20

10
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

63
16
Performance curves

VIF 6-10

H p
[m] [psi]
VIF 6-10
100 140 n nom = 2950 min-1
/247.7 ANSI/HI 1.6-2000
120
80

100

60
80
/174.8
60
40

40

20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
80
/247.7
50 70
60
40
50
30 40 /174.8
30
20
20
10
10
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
Eff
[%]
80
/247.7
70

60

50 /174.8

40

30
TM05 9807 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

64
16

Performance curves
VIF 8-16

H p
[m] [psi]
90
VIF 8-16
60 /406.4
n nom = 1450 min-1
80 ANSI/HI 1.6-2000

50 70

60
40

50 /304.8

30
40

30
20

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2
[kW] [hp]
120 /406.4
80
100

60 80

60
40
/304.8
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]
Eff
[%]
80

70

60

50
/406.4
40

30
TM05 9804 4513

20
/304.8
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

65
16
Performance curves

VIF 8-16G

H p
[m] [psi]
90
VIF 8-16G
60 /431.8 n nom = 1450 min-1
80 ANSI/HI 1.6-2000
/406.4
50 70
/355.6
60
40 /297.2

50

30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 Q [m³/h]
P2 P2
[kW] [hp]
60 /431.8
80
/406.4
70
50

60
40
50
/355.6
30 40
/297.2
30
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Q [US GPM]
Eff
[%]
90

80
/431.8
70 /355.6 /406.4

60 /297.2

50
TM05 9803 4513

40

30
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Q [US GPM]

66
16

Performance curves
VIF - 60 Hz
VIF 2.5-8

+ S
>P@ >SVL@
 9,)
  QQRP PLQ

$16,+,
 


 


 



 




 





 
          4>86*30@

     4>PñK@
3 3
>N:@ >KS@
 



 





 


 
          4>86*30@
(II
>@






 



TM06 1524 2414




          4>86*30@

67
16
Performance curves

VIF 2.5-8M

+ S
>P@ >SVL@
 9,)0
  QQRP PLQ

$16,+,
 


 


 



 




 





 
          4>86*30@

     4>PñK@
3 3
>N:@ >KS@





 





 


 
          4>86*30@
(II
>@












TM05 9810 2414



          4>86*30@

68
16

Performance curves
VIF 3-8

H p
[m] [psi]
120 VIF 3-8
80
110 /203.2 n nom = 3500 min-1
ANSI/HI 1.6-2000
70 100
/190.5
90
60 /177.8
80

50 70 /165.1

60
40
50 /149.9

30
40

20 30

20
10
10

0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]

0 20 40 60 80 100 120 140 Q [m³/h]


P2 P2
[kW] [hp]
25 35
/203.2
30
20 /190.5
25

15 20 /177.8

15 /165.1
10
10 /149.9
5
5

0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
Eff
[%]
80

70

60
/203.2
50 /190.5

40
/177.8
30
/165.1
TM05 9812 4513

20
/149.9
10
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]

69
16
Performance curves

VIF 3-11M

H p
[m] [psi]
180
/266.7 VIF 3-11
120 n nom = 3500 min-1
160 ANSI/HI 1.6-2000
/235.0
100 140

120
80
/198.4
100
/184.2
60
80

60
40

40
20
20

0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]

0 20 40 60 80 100 120 140 Q [m³/h]


P2 P2
[kW] [hp]
60 /266.7
40
50
/235.0
30 40

30
20 /198.4
20 /184.2
10
10

0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
Eff
[%]
80

70

60
/266.7
50 /235.0

40
TM05 9811 4513

30 /184.2
/198.4
20
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]

70
16

Performance curves
VIF 4-8G

+ S
>P@ >SVL@

9,)*

 QQRP PLQ
 $16,+,

 

















 
               4>86*30@

         4>PñK@


3 3
>N:@ >KS@





 








 
               4>86*30@
(II
>@



 


 



 
TM06 1525 2414




               4>86*30@

71
16
Performance curves

VIF 5-7

H p
[m] [psi]
90
VIF 5-7
/177.8
60 n nom = 3520 min-1
80 ANSI/HI 1.6-2000
/165.1

50 70
/152.4
60
40 /139.7
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
30 40
/177.8
35
25
/165.1
30
20
25 /152.4

15 20
/139.7
15
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
90

80

70

60

50
/177.8
40
/165.1
TM05 9815 4513

30
/139.7 /152.4
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

72
16

Performance curves
VIF 5-11

H p
[m] [psi]
140 200
VIF 5-11
/266.7 n nom = 3550 min-1
180 ANSI/HI 1.6-2000
120
160

100 140 /231.7

120
80
/203.2
100
/190.5
60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
90 /266.7
60 80

50 70
60 /231.7
40
50
30 40 /203.2
/190.5
30
20
20
10
10
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]
Eff
[%]
80

70

60
/266.7
50
/231.7
40

30 /203.2
TM05 9814 4513

20 /190.5

10
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

73
16
Performance curves

VIF 6-10

H p
[m] [psi]
180 /247.7
VIF 6-10
120 n nom = 3550 min-1
160 ANSI/HI 1.6-2000

100 140 /215.9

120
80

100 /174.8

60
80

60
40

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
120 /247.7
80
100
/215.9
60 80

60 /174.8
40
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
Eff
[%]
90

80

70
/247.7
60
/215.9
50
/174.8
40
TM05 9816 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

74
16

Performance curves
VIF 8-16

H p
[m] [psi]
90
130 VIF 8-16
120 /396.2 n nom = 1780 min-1
80 ANSI/HI 1.6-2000
110

70 100

90
60
80

50 /304.8
70

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2
[kW] [hp]
180 /396.2
120 160

100 140
120
80
100
60 /304.8
80
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
80
/396.2
70
/304.8
60

50

40
TM05 9809 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

75
16
Performance curves

VIF 8-16G

H p
[m] [psi]
VIF 8-16G
100 140 n nom = 1780 min-1
/431.8 ANSI/HI 1.6-2000
120
80 /406.4

100
/355.6
60
80

/297.2
60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2
[kW] [hp]
160
/431.8
100 140
/406.4
120
80
100
60 80 /355.6

60
40 /297.2
40
20
20
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
90

80
/406.4 /431.8
/355.6
70 /297.2

60

50

40
TM05 9808 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

76
16

Performance curves
HSEF, HSAF, HSMF - 50 Hz
HSEF 4-10

H p
[m] [psi]
140 HSEF 4-10
130 n nom = 2950 min-1
90 /254.0 ANSI/HI 1.6-2000
120
80
110

70 100 /228.6

90
60
80

50 70

60
40
50
30
40

20 30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
70 /254.0
50

60
40
50 /228.6

30 40

30
20
20
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
Eff
[%]
80
/254.0
70

60 /228.6

50

40
TM05 9833 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

77
16
Performance curves

HSEF 4-10G

H p
[m] [psi]
HSEF 4-10G
70 100
/228.6 n nom = 2950 min-1
ANSI/HI 1.6-2000
90
60
80
/203.2
50 70

60
40 /177.8

50

30
40

30
20

20
0 100 200 300 400 500 600 700 800 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
35
25 /228.6
30
20 /203.2
25

15 20 /177.8

15
10
10
5
5
0 100 200 300 400 500 600 700 800 Q [US GPM]
Eff
[%]
80
/228.6
70
/177.8 /203.2
60

50

40
TM05 9834 4513

30

20
0 100 200 300 400 500 600 700 800 Q [US GPM]

78
16

Performance curves
HSEF 4-12

H p
[m] [psi]
200
HSEF 4-12
140
/307.8 n nom = 2950 min-1
180 ANSI/HI 1.6-2000
120
160 /279.4

100 140
/254.0

120 /241.3
80

100 /231.9

60
80

60
40

40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
120
80 /307.8
100
/279.4
60 80
/254.0
/241.3
60
40 /231.9

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
80

70

60 /307.8
/279.4
/241.3 /254.0
50 /231.9

40
TM05 9835 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

79
16
Performance curves

HSEF 5-8

H p
[m] [psi]
90 /206.3
HSEF 5-8
60 n nom = 2950 min-1
80 ANSI/HI 1.6-2000
/190.5
50 70
/180.9

60
40 /175.5

50

30
40

30
20

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
60
40
50 /206.3

30 40 /190.5
/180.9
30 /175.5
20
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
80

70 /190.5 /206.3
/175.5 /180.9
60

50

40
TM05 9838 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

80
16

Performance curves
HSEF 5-11

H p
[m] [psi]
150
/266.7
HSEF 5-11
100 140 n nom = 2950 min-1
ANSI/HI 1.6-2000
90 130

120 /241.3
80
110

70 100

90 /209.6
60
80

50 70

60
40
50
30
40

20 30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
120 /266.7
80
100

60 /241.3
80

60 /209.6
40
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]
Eff
[%]
80

70
/241.3 /266.7
60 /209.6

50

40
TM05 9836 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

81
16
Performance curves

HSEF 5-12

H p
[m] [psi]
140 200
HSEF 5-12
/304.5
n nom = 2950 min-1
180 ANSI/HI 1.6-2000
120 /279.4
160
/266.7
100 140

120
80
100

60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
200

/304.5
120 160
/279.4
120 /266.7
80

80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70 /304.5

60 /279.4

50 /266.7

40
TM05 9837 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

82
16

Performance curves
HSEF 5-14

H p
[m] [psi]
HSEF 5-14
80
n nom = 1460 min-1
ANSI/HI 1.6-2000
50 70 /381.0

60 /355.6
40 /330.2

50
/304.8
30
40 /279.4

30
20

20

10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
60
40
/381.0
50

30 40 /355.6
/330.2
30
20 /304.8
/279.4
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70

60
/355.6
50
/381.0
40 /330.2
/304.8
TM05 9830 4513

30
/279.4
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

83
16
Performance curves

HSEF 5-15

H p
[m] [psi]
/390.7
HSEF 5-15
200 280 n nom = 2950 min-1
ANSI/HI 1.6-2000
/368.3
240
160 /345.4

200
/321.3

120
160

120
80

80

40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
300
200 /390.7
250
/368.3
150 200 /345.4
/321.3
150
100
100
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80
/321.3
70
/390.7
60 /345.4 /368.3

50

40
TM06 1211 1914

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

84
16

Performance curves
HSEF 6-10

H p
[m] [psi]
90 130 /247.7 HSEF 6-10
120 n nom = 2950 min-1
80 /228.6 ANSI/HI 1.6-2000
110

70 100

90 /206.5
60
80

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/247.7
120
80
100 /228.6

60 80
/206.5
60
40
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
80

70

60

50
/247.7
40
/228.6
TM05 9839 4513

30
/206.5
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

85
16
Performance curves

HSEF 6-12

H p
[m] [psi]
220 HSEF 6-12
/311.2 n nom = 2950 min-1
140 200
ANSI/HI 1.6-2000
180
120
160 /273.1

100 140
/247.7
120 /235.0
80
100
60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
200 280
/311.2
240
160
200
/273.1
120 160 /247.7
/235.0
120
80
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
80

70

60

50 /311.2

40 /235.0 /273.1
TM05 9840 4513

30 /247.7

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

86
16

Performance curves
HSEF 6-16

H p
[m] [psi]
70 100
HSEF 6-16
/425.5 n nom = 1460 min-1
90 ANSI/HI 1.6-2000
60 /406.4
80
/381.0
50 70
/355.6
60
40
50

30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
100
/425.5
60 80
/406.4
60 /381.0
40
/355.6
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
90

80
/355.6
70 /381.0 /425.5
/406.4
60

50

40
TM05 9829 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

87
16
Performance curves

HSEF 8-14

H p
[m] [psi]
280 /370.9 HSEF 8-14
180 260 n nom = 2950 min-1
ANSI/HI 1.6-2000
240 /342.9
160
220

140 200
/304.8
180
120
160
/266.7
100 140 /254.0
120
80
100
60
80

40 60

40
20
20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
500 /370.9
350
450
300 400 /342.9

250 350
300 /304.8
200
250
/266.7
150 200 /254.0

150
100
100
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
80
/370.9
70 /342.9
/266.7 /304.8
/254.0
60

50

40
TM05 9841 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

88
16

Performance curves
HSEF 8-15G

H p
[m] [psi]
HSEF 8-15G
80
n nom = 1470 min-1
/387.4 ANSI/HI 1.6-2000
50 70
/358.9
60
40

50
/308.1
30
40

30
20

20

10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
90
/387.4
60 80
/358.9
50 70

60
40 /308.1
50

30 40

30
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
90 /387.4
80 /358.9
/308.1
70

60

50

40
TM05 9828 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

89
16
Performance curves

HSEF 8-17A

H p
[m] [psi]
70 100
HSEF 8-17A
/457.2
n nom = 1460 min-1
/431.8
90 ANSI/HI 1.6-2000
60
80
/396.8
50 70

60 /349.3
40
50

30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
240
160 /457.2
200
/431.8
120 160
/396.8
120
80
/349.3
80
40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%] /349.3
90
/431.8 /457.2
80
/396.8
70

60

50

40
TM05 9827 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

90
16

Performance curves
HSEF 8-17Q

H p
[m] [psi]
70 100
HSEF 8-17Q
/489.0 n nom = 1470 min-1
90 ANSI/HI 1.6-2000
60
80 /457.2

50 70 /431.8

60 /406.4
40
50

30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
180
120 160 /489.0

100 140
/457.2
120
80 /431.8
100
/406.4
60 80
60
40
40
20
20
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
Eff
[%]
90
/489.0
80
/457.2
/431.8
70 /406.4

60

50

40
TM05 9826 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]

91
16
Performance curves

HSEF 8-20

H p
[m] [psi]
90 130 HSEF 8-20
120 n nom = 1470 min-1
/489.0
80 ANSI/HI 1.6-2000
110
/457.2
70 100

90 /431.8
60
/406.4
80

50 70

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
160 /489.0

100 140
/457.2
120 /431.8
80
100 /406.4

60 80

60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
80 /489.0

70 /457.2
/431.8
60
/406.4
50

40

30
TM05 9825 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

92
16

Performance curves
HSEF 8-20G

H p
[m] [psi]
90
130
/508.0
HSEF 8-20G
120 n nom = 1470 min-1
/482.6
80 ANSI/HI 1.6-2000
110
/457.2
70 100
/431.8
90
60 /406.4
80

50 70

60
40
50
30
40

20 30

20
10
10
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
200 /482.6

/457.2
120 160
/431.8
/406.4
120
80

80
/508.0
40
40

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
80
/508.0
70 /482.6
/457.2
60 /406.4 /431.8

50

40

30
TM05 9824 4513

20

10
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

93
16
Performance curves

HSEF 10-20

H p
[m] [psi]
140 /508.0 HSEF 10-20
130 n nom = 1470 min-1
90
/482.6 ANSI/HI 1.6-2000
120
80
110

70 100
/425.5
90
60
80

50 70

60
40
50
30
40

20 30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
250 350
/508.0
300
200 /482.6
250

150 200 /425.5

150
100
100
50
50

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
Eff
[%]
90

80

70

60 /482.6
/425.5 /508.0
50

40
TM05 9832 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

94
16

Performance curves
HSAF 12-19G

H p
[m] [psi]
90 130 /482.6 HSAF 12-19G
120 n nom = 1480 min-1
80 ANSI/HI 1.6-2000
110

70 100
/406.4
90
60
80 /393.7

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

0 500 1000 1500 2000 Q [m³/h]


P2 P2
[kW] [hp]
500
/482.6
300 400

300 /406.4
200 /393.7
200
100
100

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
Eff
[%]
80

70

60
/482.6
50

40
TM05 9831 4513

30 /393.7 /406.4

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

95
16
Performance curves

HSMF 4-11-2

H p
[m] [psi]
360
HSMF 4-11-2
/292.1
240 n nom = 2950 min-1
320 ANSI/HI 1.6-2000
/266.7
200 280

240
160 /225.6

200

120
160

120
80

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
240 /292.1
160
200
/266.7
120 160

120
80 /225.6
80
40
40
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
70

60

50 /292.1

40
/225.6 /266.7
30
TM05 9842 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

96
16

Performance curves
HSMF 5-13B-2

H p
[m] [psi]
450
HSMF 5-13B-2
300
/330.2 n nom = 2950 min-1
400 ANSI/HI 1.6-2000

250 350

300
200

250 /249.2

150
200

150
100

100
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
450
300 400 /330.2

250 350
300
200
250
150 200
/249.2
150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70

60 /330.2

50 /249.2

40

30
TM05 9843 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

97
16
Performance curves

HSEF, HSAF, HSMF - 60 Hz


HSEF 3-9

H p
[m] [psi]
150 /228 HSEF 3-9
100 140 n nom = 3525 min-1
/215 ANSI/HI 1.6-2000
90 130

120
80 /196
110

70 100

90
60
80
50 70

60
40
50
30
40

20 30

20
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800Q [US GPM]

0 20 40 60 80 100 120 140 160 180 Q [m³/h]


P2 P2
[kW] [hp]
60
/228
40 /215
50

30 /196
40

30
20
20
10
10

0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800Q [US GPM]
Eff
[%]
80
/228
70 /196
/215
60

50

40
TM06 0357 4513

30

20
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800Q [US GPM]

98
16

Performance curves
HSEF 3-9G

H p
[m] [psi]
110
160 /228.6 HSEF 3-9G
150 n nom = 3525 min-1
100 140 ANSI/HI 1.6-2000
/214.4
90 130

120
80
110

70 100

90
60
80
50 70

60
40
50
30
40

20 30

20
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0 40 80 120 160 200 240 Q [m³/h]


P2 P2
[kW] [hp]
80 /228.6

50 70
/214.4
60
40
50
30 40
30
20
20
10
10
0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]
Eff
[%]
80

70

60

50

40 /228.6
TM06 0358 4513

30 /214.4

20
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

99
16
Performance curves

HSEF 4-10

H p
[m] [psi]
140 200
HSEF 4-10
n nom = 3525 min-1
180 /254.0
ANSI/HI 1.6-2000
120
160

100 /228.6
140

120
80 /203.2

100
/193.5
60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 40 80 120 160 200 240 280 320 Q [m³/h]


P2 P2
[kW] [hp]
/254.0
120
80
100
/228.6
60 80
/203.2
60
40 /193.5
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70 /254.0

60

50 /228.6

40 /203.2
TM06 0359 4513

30
/193.5
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

100
16

Performance curves
HSEF 4-10G

H p
[m] [psi]
140 /228.6 HSEF 4-10G
90 130 n nom = 3525 min-1
120 ANSI/HI 1.6-2000
80
110

70 100
/190.5
90
60 /179.1
80
50 70
/155.5
60
40
50
30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0 40 80 120 160 200 240 Q [m³/h]


P2 P2
[kW] [hp]
50 70

60
40 /228.6
50

30 40 /190.5
/179.1
30
20
/155.5
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]
Eff
[%]
80

70

60 /228.6

/190.5
50

40 /179.1
TM06 0360 4513

30 /155.5

20
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

101
16
Performance curves

HSEF 4-11

H p
[m] [psi]
45
65 HSEF 4-11
/285.8 n nom = 1760 min-1
60
ANSI/HI 1.6-2000
40
55 /273.1

35 50 /260.4

45 /249.2
30
40

25 35

30
20
25
15
20

10 15

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
50

30 40
/285.8
/273.1
30
20 /260.4
/249.2
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
90

80
/285.8
70 /273.1
/260.4
60

50 /249.2

40
TM05 9847 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

102
16

Performance curves
HSEF 4-11G

H p
[m] [psi]
60
HSEF 4-11G
40 /285.8 n nom = 1760 min-1
55 ANSI/HI 1.6-2000

35 50

45 /254.0
30
40

25 35

30
20
25

15
20

10 15

10
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
25
/285.8
15 20
/254.0
15
10

10
5
5

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
Eff
[%]
90

80

70 /285.8
60 /254.0

50

40
TM05 9848 4513

30

20
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

103
16
Performance curves

HSEF 4-12

H p
[m] [psi]
HSEF 4-12
200 /307.8
280 n nom = 3550 min-1
/304.8 ANSI/HI 1.6-2000
240
/279.4
150
200
/254.0
/245.1
160 /231.9

100

120

80
50

40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0 40 80 120 160 200 240 280 320 Q [m³/h]


P2 P2
[kW] [hp]
200 /307.8
/304.8
120 160 /279.4

/254.0
120 /245.1
80
/231.9
80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
Eff
[%]
80
/304.8
70

60 /307.8
/231.9 /245.1 /279.4
50 /254.0

40
TM06 0363 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

104
16

Performance curves
HSEF 4-12hr

H p
[m] [psi]
/314.5 HSEF 4-12hr
200 280
/308.1 n nom = 3550 min-1
ANSI/HI 1.6-2000
240

150
200

160
100

120

80
50

40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0 40 80 120 160 200 240 280 320 Q [m³/h]


P2 P2
[kW] [hp]
200 /314.5
/308.1

120 160

120
80

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
Eff
[%]
70

60 /308.1
/314.5
50

40

30
TM06 0362 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

105
16
Performance curves

HSEF 5-8

H p
[m] [psi]
140 HSEF 5-8
90 130 /206.2 n nom = 3550 min-1
120 ANSI/HI 1.6-2000
80 /190.5
110

70 100

90
60
80 /162.1
50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
100

/206.2
60 80
/190.5
60
40

40
/162.1
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70

60

50
/190.5
40
/206.2
30
TM06 0364 4513

20
/162.1
10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

106
16

Performance curves
HSEF 5-8N

H p
[m] [psi]
90
130 HSEF 5-8N
/209 n nom = 3550 min-1
120
ANSI/HI 1.6-2000
80
110

70 100 /190

90
60
80
/165
50 70

60
40
50
30
40

20 30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
100

60 /209
80
/190
60
40
/165
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
90

80
/209
/190
70

60
/165
50

40
TM06 0356 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

107
16
Performance curves

HSEF 5-11G

H p
[m] [psi]
220 HSEF 5-11G
/266.7
n nom = 3550 min-1
140 200
ANSI/HI 1.6-2000
/254.0
180
120
160
/228.6
100 140

120 /203.2
80
100
60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
200 /266.7

120 160
/254.0

120 /228.6
80
/203.2
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80

70 /266.7
/228.6 /254.0
60
/203.2
50

40

30
TM06 0365 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

108
16

Performance curves
HSEF 5-12

H p
[m] [psi]
/304.8
200
280 HSEF 5-12
n nom = 3550 min-1
260
180 ANSI/HI 1.6-2000
/279.4
240
160
220

140 200 /254.0

180
120
160

100 140

120
80
100
60
80

60
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
300 /304.8
200
250
/279.4
150 200
/254.0
150
100
100
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80

70
/304.8
/279.4
60
/254.0
50

40

30
TM060366 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

109
16
Performance curves

HSEF 5-12hr

H p
[m] [psi]
300
/311.2 HSEF 5-12hr
200 /305.1 n nom = 3550 min-1
280
ANSI/HI 1.6-2000
260
180

240
160
220

140 200

180
120
160

100 140

120
80
100
60
80
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
350 /311.2
250

300 /305.1
200
250

150 200

150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
80

70
/305.1
60

50 /311.2

40

30
TM060367 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

110
16

Performance curves
HSEF 5-14

H p
[m] [psi]
70 100 /381.0
HSEF 5-14
/355.6 n nom = 1760 min-1
90 ANSI/HI 1.6-2000
60
80 /330.2

50 70 /304.8

60 /279.4
40
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
90 /381.0
60 80

50 70
/355.6
60
40 /330.2
50 /304.8
30 40 /279.4
30
20
20
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]
Eff
[%]
80

70
/355.6
60

50 /330.2
40
/304.8
30
TM05 9849 4513

20 /279.4 /381.0
10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

111
16
Performance curves

HSEF 5-14N

H p
[m] [psi]
70 100
HSEF 5-14N
n nom = 1760 min-1
90 /355.6
ANSI/HI 1.6-2000
60
80
/330.2
50 70
/304.8
60
40 /279.4
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
60
40
50 /355.6

30 40 /330.2

30 /304.8
20 /279.4
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
80

70

60
/355.6
50 /330.2
/304.8
40
/279.4
30
TM05 9850 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

112
16

Performance curves
HSEF 6-10

H p
[m] [psi]
200
HSEF 6-10
140
/247
n nom = 3550 min-1
180 ANSI/HI 1.6-2000
120
160
/222

100 140

120 /198
80
/193
100

60
80

60
40

40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
250
/247
150 200

/222
150
100
/198
100 /193
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]
Eff
[%]
90

80

70

60 /222
/193 /247
50 /198

40
TM06 0355 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

113
16
Performance curves

HSEF 6-12

H p
[m] [psi]
300 /311 HSEF 6-12
200 280 n nom = 3550 min-1
ANSI/HI 1.6-2000
180 260

240 /279
160
220

140 200 /254

180
120 /228
160

100 140

120
80
100
60
80

40 60

40
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
450 /311
300 400
350 /279
250
300
200 /254
250
150 200 /228

150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]
Eff
[%]
80

70
/311
60 /228 /254 /279

50

40
TM06 0354 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

114
16

Performance curves
HSEF 6-14

H p
[m] [psi]
/355.6 HSEF 6-14
90
n nom = 1760 min-1
60
ANSI/HI 1.6-2000
80 /330.2

50 70
/304.8

60
40 /279.4

50 /263.7
/254.0
30
40

30
20

20

10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
90
/355.6
60 80

50 70
/330.2
60
40 /304.8
50
/279.4
30 40 /263.7
/254.0
30
20
20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
90

80 /355.6
/330.2
/254.0 /263.7 /304.8
70
/279.4
60

50

40
TM05 9852 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

115
16
Performance curves

HSEF 6-14G

H p
[m] [psi]
/355.6
HSEF 6-14G
90
n nom = 1760 min-1
60
ANSI/HI 1.6-2000
80 /330.2

50 70
/304.8

60
40 /279.4

50 /251.5

30
40

30
20

20

10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
120
/355.6
80
100
/330.2
60 80
/304.8
60 /279.4
40 /251.5
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]
Eff
[%]
90

80

70 /355.6
/279.4 /304.8 /330.2
60
/251.5
50

40
TM05 9853 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

116
16

Performance curves
HSEF 6-14Q

H p
[m] [psi]
120 HSEF 6-14Q
/387.4
80 n nom = 1760 min-1
110
ANSI/HI 1.6-2000
/374.7
70 100
/342.9
90
60 /317.5
80
/307.9
50 70

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
180
/387.4
120 160
/374.7
100 140
/342.9
120 /317.5
80 /307.9
100
60 80
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [US GPM]
Eff
[%]
90

80

70
/387.4
/374.7
60 /342.9
/307.9
50 /317.5
40
TM05 9854 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 Q [US GPM]

117
16
Performance curves

HSEF 6-16

H p
[m] [psi]
140 /425.5 HSEF 6-16
90 130 n nom = 1780 min-1
ANSI/HI 1.6-2000
120 /400.1
80
110
/371.3
70 100
/355.6
90
60
80
50 70 /300.0

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
160
/425.5

100 140

120 /400.1
80
100 /371.4
/355.6
60 80
/300.0
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]
Eff
[%]
90

80 /425.5

70
/400.1
60 /371.3

50 /355.6

40 /300.0
TM05 9855 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

118
16

Performance curves
HSEF 6-16G

H p
[m] [psi]
90 130 /431.8 HSEF 6-16G
120 /425.5
n nom = 1760 min-1
80 /406.4 ANSI/HI 1.6-2000
110

70 100 /381.0

90 /355.6
60
80
/330.2
50 70
/304.8
60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/431.8
120
80
100 /425.5
/406.4
60 80
/381.0
60 /355.6
40 /330.2
40 /304.8
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
90

80 /425.5
70 /304.8 /406.4
/330.2 /381.0 /431.8
60 /355.6

50

40
TM05 9856 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

119
16
Performance curves

HSEF 6-16N

H p
[m] [psi]
90 130 HSEF 6-16N
/425.5
120 n nom = 1780 min-1
80 /406.4 ANSI/HI 1.6-2000
110

70 100 /381.0

90
60 /355.6
80

50 70

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
120
80
100 /425.5
/406.4
60 80
/381.0
60 /355.6
40
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70 /425.5
/355.6 /381.0 /406.4
60

50

40

30
TM05 9857 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

120
16

Performance curves
HSEF 6-17

H p
[m] [psi]
90 130 /425.5 HSEF 6-17
120 n nom = 1760 min-1
/406.4 ANSI/HI 1.6-2000
80
110 /393.7
/381.0
70 100 /368.3
/355.6
90
60 /342.9
80

50 70

60
40
50
30
40

20 30

20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
/406.4
100 /425.5
/393.7
/381.0
60 /368.3
80 /355.6
/342.9
60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
80

70

60

50 /393.7
/381.0
40 /406.4
/368.3
30 /355.6
/342.9
TM05 9858 4513

20 /425.5

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

121
16
Performance curves

HSEF 6-18

H p
[m] [psi]
150 /444.5 HSEF 6-18
100
140 n nom = 1770 min-1
/425.5 ANSI/HI 1.6-2000
90 130

120
80 /387.4
110

70 100

90
60
80

50 70

60
40
50
30
40

30
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
200 /444.5

/425.5
120 160
/387.4
120
80

80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
80
/444.5
70 /425.5
/387.4
60

50

40

30
TM05 9859 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

122
16

Performance curves
HSEF 8-13

H p
[m] [psi]
HSEF 8-13
80 /330.2
n nom = 1760 min-1
ANSI/HI 1.6-2000
50 70
/304.8

60
40 /279.4

50
/247.7
30
40

30
20

20

10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/330.2
120
80
100 /304.8
60 80 /279.4
60
40 /247.7
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]
Eff
[%]
90

80

70 /330.2
/247.7 /304.8
60 /279.4

50

40
TM05 9860 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

123
16
Performance curves

HSEF 8-15

H p
[m] [psi]
110
/393.7 HSEF 8-15
n nom = 1760 min-1
70 100 /368.3 ANSI/HI 1.6-2000
90
60 /342.9
80
/317.5
50 70
/295.4
60
40
50
30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
240
160 /393.7
200
/368.3
120 160 /342.9

120 /317.5
80 /295.4
80
40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
90
/393.7
80
/342.9 /368.3
/295.4 /317.5
70

60

50

40
TM05 9861 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

124
16

Performance curves
HSEF 8-15G

H p
[m] [psi]
110 HSEF 8-15G
/387.4
n nom = 1780 min-1
70 100
ANSI/HI 1.6-2000
/358.9
90
60
80
/317.5
50 70

60
40 /279.4

50
30
40

20 30

20
10
10

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
160

140 /387.4
100
/358.9
120
80
100 /317.5

60 80
/279.4
60
40
40
20
20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]
Eff
[%]
90
/387.4
80 /317.5 /358.9
70 /279.4

60

50

40
TM05 9862 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

125
16
Performance curves

HSEF 8-17A

H p
[m] [psi]
HSEF 8-17A
100 /457.2
140
/431.8
n nom = 1780 min-1
ANSI/HI 1.6-2000
120 /406.4
80
/381.0
100
/355.6
60
80 /330.2

/304.8
60
40

40

20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
400
/457.2
250 350
/431.8
300
200 /406.4
250
/381.0
150 200
/355.6
150 /330.2
100
/304.8
100
50
50
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
Eff
[%]
90 /457.2
/406.4
80 /381.0
/304.8 /330.2 /431.8
/355.6
70

60

50

40
TM05 9864 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

126
16

Performance curves
HSEF 8-17Q

H p
[m] [psi]
HSEF 8-17Q
100 /431.8
140 n nom = 1780 min-1
ANSI/HI 1.6-2000
120 /406.4
80
/381.0
100
/355.6
60
80

60
40

40

20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
300 /431.8
200
250
/406.4
150 200 /381.0

150 /355.6
100
100
50
50

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]
Eff
[%]
90
/431.8
80 /355.6 /406.4
/381.0

70

60

50

40
TM05 9865 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

127
16
Performance curves

HSEF 8-17SS

H p
[m] [psi]
HSEF 8-17SS
100 /457.2
140
/431.8 n nom = 1780 min-1
ANSI/HI 1.6-2000
120 /406.4
80
/381.0
100
/355.6
60
80 /330.2

/304.8
60
40

40

20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
400
/457.2
250 350
/431.8
300
200 /406.4
250
/381.0
150 200
/355.6
150 /330.2
100
/304.8
100
50
50
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
Eff
[%]
90 /457.2
/406.4
80 /381.0 /431.8
/304.8 /330.2
/355.6
70

60

50

40
TM05 9863 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

128
16

Performance curves
HSEF 8-17W

H p
[m] [psi]
HSEF 8-17W
100 140 n nom = 1770 min-1
/431.8 ANSI/HI 1.6-2000
120
80 /406.4

100 /381.0

60
80

60
40

40

20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

0 200 400 600 800 Q [m³/h]


P2 P2
[kW] [hp]
160
/381.0
100 140 /406.4
/431.8
120
80
100

60 80

60
40
40
20
20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]
Eff
[%]
90
/381.0
80 /406.4
/431.8
70

60

50

40
TM05 9866 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

129
16
Performance curves

HSEF 8-17Wuc

H p
[m] [psi]
HSEF 8-17Wuc
100 140
/457.2 n nom = 1780 min-1
ANSI/HI 1.6-2000
/431.8
120
80 /406.4

100

60
80

60
40

40

20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

0 200 400 600 800 Q [m³/h]


P2 P2
[kW] [hp]
240
160 /457.2
200

120 160 /431.8


/406.4
120
80

80
40
40
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]
Eff
[%]
90 /406.4 /457.2
80 /431.8

70

60

50

40
TM05 9867 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

130
16

Performance curves
HSEF 8-20

H p
[m] [psi]
180
HSEF 8-20
/489.0 n nom = 1780 min-1
120
160 ANSI/HI 1.6-2000
/457.2
100 140
/431.8

120 /406.4
80

100

60
80

60
40

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 200 400 600 800 Q [m³/h]


P2 P2
[kW] [hp]
280 /489.0
200

240
/457.2
160
200 /431.8
/406.4
120 160

120
80
80
40
40
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90

80
/489.0
70
/406.4 /457.2
60 /431.8
50

40
TM05 9868 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

131
16
Performance curves

HSEF 8-20G

H p
[m] [psi]
/508.0 HSEF 8-20G
180 n nom = 1780 min-1
120 /482.6 ANSI/HI 1.6-2000
160
/457.2
100 140
/431.8

120 /406.4
80

100

60
80

60
40

40
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
300 /508.0
400
/482.6
300 /457.2
200 /431.8
/406.4
200

100
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
90

80

70 /457.2
/482.6 /508.0
60 /406.4
/431.8

50

40
TM05 9869 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

132
16

Performance curves
HSEF 10-16

H p
[m] [psi]
140 HSEF 10-16
/406.4
130 n nom = 1775 min-1
90
ANSI/HI 1.6-2000
120
/378.0
80
110

70 100

90 330.2
60
80

50 70

60
40
50
30
40

20 30

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

0 400 800 1200 1600 2000 Q [m³/h]


P2 P2
[kW] [hp]
450
/406.4
300 400

250 350
/378.0
300
200
250
/330.2
150 200

150
100
100
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
Eff
[%]
90

80
/406.4
70 /330.2
/378.0
60

50

40
TM05 9844 4513

30

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

133
16
Performance curves

HSEF 10-20

H p
[m] [psi]
220 HSEF 10-20
/508.0 n nom = 1780 min-1
140 200
ANSI/HI 1.6-2000
180
120
160

100 /425.5
140

120
80 /368.3
100
60
80

40 60

40
20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]

0 200 400 600 800 1000 1200 1400 Q [m³/h]


P2 P2
[kW] [hp]
600 /508.0
400
500

300 400
/425.5
300
200
/368.3
200
100
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]
Eff
[%]
90

80

70
/425.5
60 /508.0

50

40 /368.3
TM05 9845 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]

134
16

Performance curves
HSAF 12-19G

H p
[m] [psi]
140 200
HSAF 12-19G
n nom = 1760 min-1
/482.6
180 ANSI/HI 1.6-2000
120
160

100 140
/406.4

120
80 /393.7
100

60
80

40 60

40
20
20

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

0 400 800 1200 1600 2000 Q [m³/h]


P2 P2
[kW] [hp]
600 800
/482.6
700
500

600
400
500 /406.4
/393.7
300 400

300
200
200
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
Eff
[%]
90

80
/482.6
70

60
/393.7
50 /406.4
40
TM05 9846 4513

30

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

135
16
Performance curves

HSMF 4-5-2

H p
[m] [psi]
140 200
HSMF 4-5-2
/355.6 n nom = 1760 min-1
180 ANSI/HI 1.6-2000
120
160

100 140

120 /285.8
80
100

60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
120
80 /355.6
100

60 80

60
40 /285.8
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
Eff
[%]
80

70

60
/355.6
50 /285.8

40

30
TM05 9870 4513

20

10
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

136
16

Performance curves
HSMF 4-11-2

H p
[m] [psi]
350 500 /292.1 HSMF 4-11-2
n nom = 3525 min-1
450 ANSI/HI 1.6-2000
300
400

250 350
/225.5
300
200
250

150
200

100 150

100
50
50

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 40 80 120 160 200 240 280 320 360 Q [m³/h]


P2 P2
[kW] [hp]
400 /292.1

250 350

300
200
250

150 200
/225.5
150
100
100
50
50
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
70

60
/292.1
50

40

30
/225.5
TM06 0361 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

137
16
Performance curves

HSMF 4-14-3

+ S
>P@ >SVL@
 +60)

 QQRP PLQ

$16,+,




  





 







 


          4>86*30@

     4>PñK@


3 3
>N:@ >KS@


 



 

 






          4>86*30@
(II
>@






 




TM06 1526 2414




          4>86*30@

138
16

Performance curves
HSMF 5-7-2

H p
[m] [psi]
220 HSMF 5-7-2
/381.0 n nom = 1760 min-1
140 200
ANSI/HI 1.6-2000
180
120
160

100 140

120 /300.0
80
100
60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
160

140 /381.0
100
120
80
100

60 80
/300.0
60
40
40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70

60 /381.0
/300.0
50

40

30
TM05 9872 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

139
16
Performance curves

HSMF 5-13B-2

H p
[m] [psi]
600 HSMF 5-13B-2
/304.8
400
550 n nom = 3550 min-1
ANSI/HI 1.6-2000
350 500

450
300
400

250 350

300 /254.0
200
250
150
200

100 150

100
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
600
400 /304.8
500

300 400

300 /254.0
200
200
100
100

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80
/304.8
70
/254.0
60

50

40

30
TM060368 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

140
16

Performance curves
HSMF 5-16B-3

H p
[m] [psi]
440 HSMF 5-16B-3
/431.8 n nom = 1775 min-1
280 400
ANSI/HI 1.6-2000
360
240
/382.5
320

200 280

240
160
200
120
160

80 120

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
400 /431.8

250 350
300
200 /382.5
250
150 200
150
100
100
50
50
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
80

70
/382.5 /431.8
60

50

40

30
TM05 9873 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

141
16
Performance curves

HSMF 5-16B-3 low range

H p
[m] [psi]
280 400
HSMF 5-16B-3 Low Range
n nom = 1775 min-1
360 ANSI/HI 1.6-2000
/406.4
240
320

200 280

240 /330.2
160
200

120
160

80 120

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
250 /406.4

150 200

150
100 /330.2
100
50
50

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
Eff
[%]
80

70
/330.2 /406.4
60

50

40

30
TM05 9874 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

142
16

Performance curves
HSMF 5-16B-3 high range

H p
[m] [psi]
320 450
HSMF 5-16B-3 High Range
n nom = 1775 min-1
/436.4
280 400 ANSI/HI 1.6-2000
/432.1

350
240

300
200

250
160
200
120
150

80
100

40 50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
450
300 /436.4
400
/432.1
250 350
300
200
250
150 200
150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70 /436.4
/432.1
60

50

40

30
TM05 98750 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

143
16
Performance curves

HSMF 6-10B-2

H p
[m] [psi]
240 HSMF 6-10B-2
160 /406.4 n nom = 1750 min-1
220
ANSI/HI 1.6-2000

140 200

180
120
160

100 140
/317.5
120
80
100
60
80

40 60

40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
240

150 /406.4
200

160
100
120
/317.5
80
50
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500Q [US GPM]
Eff
[%]
90

80
/406.4
70 /317.5
60

50

40
TM05 9876 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500Q [US GPM]

144
16

Performance curves
HSMF 8-15-6

H p
[m] [psi]
550
HSMF 8-15-6
/381.0 n nom = 1750 min-1
350 500 ANSI/HI 1.6-2000
/355.6
450
300
400

250 350

300
200
250

150
200

100 150

100
50
50
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
450
300 400 /381.0
/355.6
250 350
300
200
250
150 200
150
100
100
50
50
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%] /381.0
80
/355.6
70

60

50

40

30
TM05 98777 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

145
16
Performance curves

HSEF, HSAF, HSMF - diesel


HSEF 4-10, 2600 min-1

H p
[m] [psi]
70 100
HSEF 4-10
/254.0
n nom = 2600 min-1
90 /241.3 ANSI/HI 1.6-2000
60
80

50 70

60
40
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
50
/254.0
30 40 /241.3

30
20

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]
Eff
[%]
80

70
/254.0
60
/241.3
50

40

30
TM05 9941 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

146
16

Performance curves
HSEF 4-10, 2800 min-1

H p
[m] [psi]
120 HSEF 4-10
/254.0
80
110 n nom = 2800 min-1
ANSI/HI 1.6-2000
/241.3
70 100

90
60
80

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
60
40 /254.0
50 /241.3

30 40

30
20

20
10
10
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]
Eff
[%]
80

70 /254.0

60 /241.3

50

40

30
TM05 9945 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

147
16
Performance curves

HSEF 4-10, 2950 min-1

H p
[m] [psi]
90
130 HSEF 4-10
/254.0
120 n nom = 2950 min-1
80 ANSI/HI 1.6-2000
110

70 100 /228.6

90
60
80

50 70

60
40
50
30
40

20 30

20
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
70 /254.0
50

60
40
50 /228.6

30 40

30
20
20
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
Eff
[%]
80
/254.0
70

60 /228.6
50

40

30
TM05 9951 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

148
16

Performance curves
HSEF 4-10, 3000 min-1

+ S
>P@ >SVL@
   +6()
 QQRP PLQ
 $16,+,


 




 







 





 
           4>86*30@

      4>PñK@


3 3
>N:@ >KS@


 


 


 






           4>86*30@
(II
>@











TM05 9962 3614




           4>86*30@

149
16
Performance curves

HSEF 4-10G, 2950 min-1

H p
[m] [psi]
70 100 /228.6
HSEF 4-10G
n nom = 2950 min-1
90 ANSI/HI 1.6-2000
60
80
/203.2
50 70

60 /177.8
40
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
25 35
/228.6
30
20 /203.2
25

15 20 /177.8

15
10
10
5
5

0 0
0 100 200 300 400 500 600 700 800 Q [US GPM]
Eff
[%]
80
/228.6
70
/203.2
60 /177.8

50

40

30
TM05 9952 4513

20

10
0 100 200 300 400 500 600 700 800 Q [US GPM]

150
16

Performance curves
HSEF 4-10G, 3000 min-1

+ S
>P@ >SVL@
   +6()*
QQRP PLQ
 $16,+,



 

 






 





 
          4>86*30@

     4>PñK@


3 3
>N:@ >KS@


 


 


  






          4>86*30@
(II
>@




 


 


TM05 9963 3614




          4>86*30@

151
16
Performance curves

HSEF 4-11, 1760 min-1

H p
[m] [psi]
HSEF 4-11
50 70 n nom = 1760 min-1
ANSI/HI 1.6-2000
/285.8
60
40 /273.1

50 /260.4
/249.2
30
40

30
20

20

10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
40
/285.8
25 35
/273.1
30
20 /260.4
25 /249.2

15 20

15
10
10
5
5
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
Eff
[%]
90

80
/285.8
70
/273.1
/260.4
60

50 /249.2

40
TM05 9891 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

152
16

Performance curves
HSEF 4-11G, 1760 min-1

H p
[m] [psi]
HSEF 4-11G
50 70 n nom = 1760 min-1
ANSI/HI 1.6-2000
60
40 /285.8

50
/254.0
30
40

30
20

20

10
10

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
25
/285.8
15 20
/254.0
15
10

10
5
5

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
Eff
[%]
80

70 /285.8
60 /254.0

50

40

30
TM05 9892 4513

20

10
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

153
16
Performance curves

HSEF 4-12, 2100 min-1

H p
[m] [psi]
70 100 /307.9 HSEF 4-12
n nom = 2100 min-1
90 ANSI/HI 1.6-2000
60
80 /279.4

50 70

/241.3
60
40
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
40 /307.9

25 35
/279.4
30
20
25
/241.3
15 20
15
10
10
5
5
0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]
Eff
[%]
80

70

60

50
/307.9
40

30 /279.4
TM05 9934 4513

20
/241.3
10
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]

154
16

Performance curves
HSEF 4-12, 2350 min-1

H p
[m] [psi]
90 130
/307.9
HSEF 4-12
120 n nom = 2350 min-1
80 ANSI/HI 1.6-2000
110
/279.4
70 100

90
60
80 /241.3
50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
60
40 /307.9
50
/279.4
30 40
/241.3
30
20
20
10
10

0 0
0 100 200 300 400 500 600 700 800 Q [US GPM]
Eff
[%]
80

70 /307.9
/279.4
60 /241.3
50

40

30
TM05 9936 4513

20

10
0 100 200 300 400 500 600 700 800 Q [US GPM]

155
16
Performance curves

HSEF 4-12, 2950 min-1

H p
[m] [psi]
140 200
HSEF 4-12
/307.9
n nom = 2950 min-1
180 ANSI/HI 1.6-2000
120
160 /279.4

100 140
/254.0

120
80 /241.3
/231.9
100

60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

0 50 100 150 200 250 Q [m³/h]


P2 P2
[kW] [hp]
120
/307.9
80
100
/279.4
60 80
/254.0
/241.3
60 /231.9
40
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
Eff
[%]
80
/241.3
70
/307.9
60 /254.0
/279.4
50 /231.9

40

30
TM05 9953 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]

156
16

Performance curves
HSEF 4-12, 3000 min-1

+ S
>P@ >SVL@
   +6()
QQRP PLQ
  $16,+,



 








 





 
              4>86*30@

       4>PñK@


3 3
>N:@ >KS@
 




 

 








 
              4>86*30@
(II
>@






 

 

 
TM05 9964 3614




              4>86*30@

157
16
Performance curves

HSEF 5-8, 2950 min-1

H p
[m] [psi]
70 100
HSEF 5-8
n nom = 2950 min-1
90 /206.3
ANSI/HI 1.6-2000
60
80
/190.5
50 70
/180.9

60
40 /175.5

50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
60
40
50 /206.3

30 40 /190.5
/180.9
30 /175.5
20
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70 /206.3
/175.5 /180.9 /190.5
60

50

40

30
TM05 9956 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

158
16

Performance curves
HSEF 5-8, 3000 min-1

+ S
>P@ >SVL@
 
+6()
 QQRP PLQ
 $16,+,



  








 





 
                4>86*30@

        4>PñK@


3 3
>N:@ >KS@

 


 







 
                4>86*30@
(II
>@












TM05 9967 3614




                4>86*30@

159
16
Performance curves

HSEF 5-11, 2600 min-1

H p
[m] [psi]
120 HSEF 5-11
80
110
/266.7 n nom = 2600 min-1
ANSI/HI 1.6-2000
70 100
/241.3
90
60
80

50 70 /209.6

60
40
50
30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
80 /266.7
50 70
60 /241.3
40
50
30 40 /209.6

30
20
20
10
10
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
Eff
[%]
80
/241.3 /266.7
70

60

50 /209.6

40

30
TM05 9942 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

160
16

Performance curves
HSEF 5-11, 2800 min-1

H p
[m] [psi] /266.7
90 130 HSEF 5-11
120 /254.0 n nom = 2800 min-1
80 ANSI/HI 1.6-2000
110

70 100
/228.6
90
60
80 /209.6
50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
100 /266.7

/254.0
60 80

/228.6
60
40
/209.6
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
80

70 /254.0
/228.6 /266.7
60
/209.6
50

40

30
TM05 9946 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

161
16
Performance curves

HSEF 5-11, 2950 min-1

H p
[m] [psi]
HSEF 5-11
160
n nom = 2950 min-1
/266.7
ANSI/HI 1.6-2000
100 140

120 /241.3
80

100
/209.6
60
80

60
40

40

20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
120 /266.7
80
100

60 /241.3
80

60 /209.6
40
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]
Eff
[%]
80

70
/241.3 /266.7
60 /209.6

50

40

30
TM05 9954 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

162
16

Performance curves
HSEF 5-11, 3000 min-1

+ S
>P@ >SVL@
+6()

 QQRP PLQ
$16,+,
 


















 
          4>86*30@

          4>PñK@


3 3
>N:@ >KS@
 

 



 







 
          4>86*30@
(II
>@








  


TM05 9965 3614




          4>86*30@

163
16
Performance curves

HSEF 5-12, 2950 min-1

H p
[m] [psi]
140 200 /304.8
HSEF 5-12
n nom = 2950 min-1
180 ANSI/HI 1.6-2000
120 /279.4
160
/266.7
100 140

120
80
100

60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
180 /304.8
120 160

100 140
/279.4
120 /266.7
80
100
60 80
60
40
40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]
Eff
[%]
80
/304.8
70

60 /279.4

50 /266.7
40

30
TM05 9955 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

164
16

Performance curves
HSEF 5-12, 3000 min-1

+ S
>P@ >SVL@
 
 +6()
QQRP PLQ
  $16,+,

 

 








 





 
          4>86*30@

         4>PñK@


3 3
>N:@ >KS@
 
 
 

 


 





          4>86*30@
(II
>@




 

 




TM05 9966 3614




          4>86*30@

165
16
Performance curves

HSEF 5-14, 1460 min-1

H p
[m] [psi]
70
/381.0
HSEF 5-14
45 65 /355.6 n nom = 1460 min-1
ANSI/HI 1.6-2000
60
40 /330.2
55

35 50
/304.8
45
30
40 /279.4

25 35

30
20
25
15
20

10 15

10
5
5
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
/381.0
50

30 40
/355.6
/330.2
30
20 /304.8
/279.4
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70

60
/355.6
50
/381.0
40 /330.2
30 /304.8
/279.4
TM05 9880 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

166
16

Performance curves
HSEF 5-14, 1760 min-1

H p
[m] [psi]
70 100 /381.0 HSEF 5-14
/355.6 n nom = 1760 min-1
90 ANSI/HI 1.6-2000
60
80 /330.2

50 70 /304.8

60 /279.4
40
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
90 /381.0
60 80

50 70
/355.6
60
40 /330.2
50 /304.8
30 40 /279.4
30
20
20
10
10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]
Eff
[%]
80

70
/355.6
60

50 /330.2
40
/304.8
30
TM05 9893 4513

20 /279.4 /381.0

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Q [US GPM]

167
16
Performance curves

HSEF 5-14, 2100 min-1

H p
[m] [psi]
HSEF 5-14
160
n nom = 2100 min-1
ANSI/HI 1.6-2000
100 /381.0
140

/355.6
120
80
/317.5
100

60 /279.4
80

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
140 /381.0
100
120 /355.6
80
100
/317.5
60 80
/279.4
60
40
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70

60 /381.0

50
/317.5 /355.6
40

30 /279.4
TM05 9933 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

168
16

Performance curves
HSEF 5-14, 2300 min-1

H p
[m] [psi]
180
HSEF 5-14
120 /381.0 n nom = 2300 min-1
160 ANSI/HI 1.6-2000
/355.6
100 140
/317.5
120
80

100 /279.4

60
80

60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
200
/381.0
120 160 /355.6

120 /317.5
80

80 /279.4

40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80

70

60 /279.4
/381.0
/317.5
50

40 /355.6

30
TM05 9837 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

169
16
Performance curves

HSEF 5-14, 2350 min-1

H p
[m] [psi]
180
HSEF 5-14
/381.0
120 /355.6
n nom = 2350 min-1
160 ANSI/HI 1.6-2000

100 140
/317.5

120
80
/279.4
100

60
80

60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 50 100 150 200 250 300 350 400 450 Q [m³/h]


P2 P2
[kW] [hp]
200
/381.0
/355.6
120 160

120 /317.5
80
/279.4
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80

70

60

50 /381.0
40 /355.6

30 /317.5
TM05 9938 4513

20
/279.4
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

170
16

Performance curves
HSEF 5-14, 2400 min-1

H p
[m] [psi]
180
/381.0 HSEF 5-14
/355.6
120 n nom = 2400 min-1
160 ANSI/HI 1.6-2000

100 140 /317.5

120
80
/279.4
100

60
80

60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 50 100 150 200 250 300 350 400 450 Q [m³/h]


P2 P2
[kW] [hp]
200 /381.0
/355.6
120 160
/317.5
120
80
/279.4
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
80

70
/381.0
60

50
/355.6
40

30 /317.5
TM05 9939 4513

20
/279.4
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

171
16
Performance curves

HSEF 5-14N, 1760 min-1

H p
[m] [psi]
70 100
HSEF 5-14N
n nom = 1760 min-1
90 /355.6
ANSI/HI 1.6-2000
60
80
/330.2
50 70
/304.8
60
40 /279.4
50

30
40

20 30

20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
60
40
50 /355.6

30 40 /330.2

30 /304.8
20 /279.4
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
80

70

60
/355.6
50 /330.2

/304.8
40

30 /279.4
TM05 9894 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

172
16

Performance curves
HSEF 5-14N, 2600 min-1

H p
[m] [psi]
220 HSEF 5-14N
n nom = 2600 min-1
140 200 /355.6
ANSI/HI 1.6-2000
180
120
160

100 140

120
80
/254.0
100
60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
180
/355.6
120 160

100 140
120
80
100
60 80
/254.0
60
40
40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
80

70
/355.6
60

50

40

30
TM05 9943 4513

20
/254.0
10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

173
16
Performance curves

HSEF 5-15, 2950 min-1

+ S
>P@ >SVL@

+6()
  QQRP PLQ
$16,+,


 















 
          4>86*30@

     4>PñK@


3 3
>N:@ >KS@

 


  







 
          4>86*30@
(II
>@




  






TM06 2093 3614


          4>86*30@

174
16

Performance curves
HSEF 5-15, 3000 min-1

+ S
>P@ >SVL@

+6()
  QQRP PLQ
$16,+,


 















 
          4>86*30@

     4>PñK@


3 3
>N:@ >KS@

 


  







 
          4>86*30@
(II
>@




  






TM06 2094 3614


          4>86*30@

175
16
Performance curves

HSEF 6-10, 2800 min-1

H p
[m] [psi]
120 /254.0
HSEF 6-10
80
110 n nom = 2800 min-1
/247.7
ANSI/HI 1.6-2000
70 100 /228.6

90
60
/203.2
80

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 Q [m³/h]
P2 P2
[kW] [hp]
120
/254.0
80
100 /247.7

/228.6
60 80

/203.2
60
40

40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]
Eff
[%]
90
/247.7
80
/203.2
70 /228.6 /254.0
60

50

40
TM05 9947 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

176
16

Performance curves
HSEF 6-10, 2950 min-1

H p
[m] [psi]
/247.7
90 130 HSEF 6-10
120 n nom = 2950 min-1
80 /228.6 ANSI/HI 1.6-2000
110

70 100
/206.5
90
60
80
50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/247.7
120
80
100 /228.6

60 80
/206.5
60
40
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
90

80

70

60

50
/247.7
40
TM05 9957 4513

30 /228.6
/206.5
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

177
16
Performance curves

HSEF 6-10, 3000 min-1

+ S
>P@ >SVL@ 
  +6()
 QQRP PLQ
 $16,+,
 

 




 







 





 
             4>86*30@

       4>PñK@


3 3
>N:@ >KS@
 




 

  






             4>86*30@
(II
>@











TM05 9968 3614




             4>86*30@

178
16

Performance curves
HSEF 6-12, 1760 min-1

H p
[m] [psi]
HSEF 6-12
80
/330.2 n nom = 1760 min-1
ANSI/HI 1.6-2000
50 70 /311.2
/292.1
60
40
/261.9
50

30
40

30
20

20

10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
/330.2
60
40 /311.2
50
/292.1
30 40
/261.9
30
20
20
10
10

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
80

70 /330.2

60 /311.2
/261.9 /292.1
50

40

30
TM05 9895 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

179
16
Performance curves

HSEF 6-12, 2600 min-1

H p
[m] [psi]
/311.2
HSEF 6-12
160
n nom = 2600 min-1
ANSI/HI 1.6-2000
100 140
/284.8

120
80

100
/235.0
60
80

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
180
120 /311.2
160
/284.8
100 140
120
80
100
/235.0
60 80
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
80

70
/311.2
60 /284.8

50

40 /235.0

30
TM05 9944 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

180
16

Performance curves
HSEF 6-12, 2800 min-1

H p
[m] [psi]
140 200
HSEF 6-12
/311.2 n nom = 2800 min-1
180 ANSI/HI 1.6-2000
120
160
/273.1
100 140

120
80 /235.0
100

60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2
[kW] [hp]
240
160 /311.2
200

120 160 /273.1

120
80 /235.0
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
80

70

60
/311.2
50
/235.0 /273.1
40

30
TM05 9948 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

181
16
Performance curves

HSEF 6-12, 2950 min-1

H p
[m] [psi]
/311.2
140 200
HSEF 6-12
n nom = 2950 min-1
180 ANSI/HI 1.6-2000
120
160 /273.1

100 140
/247.7

120 /235.0
80
100

60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
200 280
/311.2
240
160
200 /273.1
120 160 /247.7
/235.0
120
80
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
80

70

60

50 /311.2

40 /235.0 /273.1
30 /247.7
TM05 9958 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

182
16

Performance curves
HSEF 6-12, 3000 min-1

+ S
>P@ >SVL@
 +6()

QQRP PLQ
 
$16,+,

 


  









 





 
             4>86*30@

       4>PñK@


3 3
>N:@ >KS@
 


 


  









 
             4>86*30@
(II
>@




  






TM05 9969 3614




             4>86*30@

183
16
Performance curves

HSEF 6-14, 1760 min-1

H p
[m] [psi]
70 100
HSEF 6-14
/355.6 n nom = 1760 min-1
90 ANSI/HI 1.6-2000
60
80 /330.2

50 70
/304.8

60
40 /279.4
50 /263.7

30 /254.0
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
90
/355.6
60 80

50 70
/330.2
60
40 /304.8
50
/279.4
30 40 /263.7
/254.0
30
20
20
10
10
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
90

80 /330.2
/355.6
/254.0
70 /263.7 /304.8
/279.4
60

50

40
TM05 9896 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

184
16

Performance curves
HSEF 6-14Q, 1760 min-1

H p
[m] [psi]
120
/387.4
HSEF 6-14Q
80
110 n nom = 1760 min-1
/374.7 ANSI/HI 1.6-2000
70 100
/342.9
90
60 /317.5
80

50 /307.9
70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
180 /387.4
120 160
/374.7
100 140
/342.9
120 /317.5
80 /307.9
100
60 80
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]
Eff
[%]
90

80
/387.4
70
/374.7
60 /342.9
/317.5
50 /307.9
40
TM05 9898 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

185
16
Performance curves

HSEF 6-14Q, 2100 min-1

H p
[m] [psi]
180
HSEF 6-14Q
120 n nom = 2100 min-1
160 /387.4 ANSI/HI 1.6-2000

100 140
/355.6

120
80

100 /311.5

60
80

60
40

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 Q [m³/h]
P2 P2
[kW] [hp]
200 280
/387.4
240
160
200 /355.6
120 160 /311.5
120
80
80
40
40

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000Q [US GPM]
Eff
[%]
90

80

70

60
/387.4
50
/355.6
40
TM05 9931 4513

30
/311.5
20
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000Q [US GPM]

186
16

Performance curves
HSEF 6-14G, 1760 min-1

H p
[m] [psi]
70 100
HSEF 6-14G
/355.6 n nom = 1760 min-1
90 ANSI/HI 1.6-2000
60
80 /330.2

50 70
/304.8

60
40 /279.4

50 /251.5
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
120
/355.6
80
100
/330.2
60 80
/304.8
/279.4
60
40 /251.5
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]
Eff
[%]
90

80

70 /355.6
/279.4 /330.2
60 /304.8
/251.5
50

40
TM05 9897 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

187
16
Performance curves

HSEF 6-14G, 2100 min-1

H p
[m] [psi]
HSEF 6-14G
100 140
/355.6 n nom = 2100 min-1
ANSI/HI 1.6-2000
120 /330.2
80

100 /304.8

60 /279.4
80
/254.0

60
40

40

20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
200 /355.6

120 160 /330.2

120 /304.8
80
/279.4
80
/254.0
40
40

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90

80

70

60

50

40 /254.0 /355.6
/279.4 /304.8 /330.2
TM05 9932 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

188
16

Performance curves
HSEF 6-16, 1460 min-1

H p
[m] [psi]
70 100
HSEF 6-16
/425.5 n nom = 1460 min-1
90 ANSI/HI 1.6-2000
60 /406.4
80
/381.0
50 70
/355.6
60
40
50

30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
100
/425.5
60 80
/406.4
60 /381.0
40
/355.6
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
Eff
[%]
90

80
/355.6
70 /425.5
/381.0 /406.4
60

50

40
TM05 9881 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

189
16
Performance curves

HSEF 6-16, 1780 min-1

H p
[m] [psi]
HSEF 6-16
100 140 /425.5 n nom = 1780 min-1
ANSI/HI 1.6-2000
120 /400.1
80
/371.4
100
/355.6

60
80
/300.0

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
160
/425.5

100 140

120 /400.1
80
100 /371.4
/355.6
60 80
/300.0
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]
Eff
[%]
90

80 /425.5

70
/400.1
60 /371.4

50 /355.6

40 /300.0
TM05 9899 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

190
16

Performance curves
HSEF 6-16G, 1760 min-1

H p
[m] [psi]
HSEF 6-16G
100 140 n nom = 1760 min-1
/431.8 ANSI/HI 1.6-2000
/425.5
120
80 /406.4

100 /381.0

/355.6
60
80 /330.2

/304.8
60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/431.8
120
80
100 /425.5
/406.4
60 80
/381.0
60 /355.6
40 /330.2
40 /304.8
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
90

80 /425.5
70 /304.8 /355.6 /406.4
/431.8
/330.2 /381.0
60

50

40
TM05 9900 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

191
16
Performance curves

HSEF 6-16N, 1780 min-1

H p
[m] [psi]
HSEF 6-16N
100 140 n nom = 1780 min-1
ANSI/HI 1.6-2000
/425.5
120
80 /406.4

100 /381.0

60 /355.6
80

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
100 /425.5
/406.4
60 80
/381.0
60 /355.6
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
90

80

70 /425.5
/355.6 /406.4
/381.0
60

50

40
TM05 9901 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

192
16

Performance curves
HSEF 6-17, 1760 min-1

H p
[m] [psi]
HSEF 6-17
100 140 n nom = 1760 min-1
/425.5 ANSI/HI 1.6-2000
120 /406.4
80 /393.7
/381.0
100 /368.3
/355.6
60 /342.9
80

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

0 100 200 300 400 500 Q [m³/h]


P2 P2
[kW] [hp]
/425.5 /406.4
100 /393.7
/381.0
60 /368.3
80 /355.6
/342.9
60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
Eff
[%]
80

70

60

50 /393.7
/381.0
40 /406.4
/368.3
30 /355.6
/342.9
TM05 9902 4513

20 /425.5

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]

193
16
Performance curves

HSEF 6-17, 2100 min-1

H p
[m] [psi]
180 /425.5
HSEF 6-17
120 n nom = 2100 min-1
160 /406.4 ANSI/HI 1.6-2000
/393.7
/381.0
100 140
/368.3
/355.6
120 /330.2
80

100

60
80

60
40

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2
[kW] [hp]
180 /425.5 /406.4
/393.7
120 160 /381.0
/368.3
100 140 /355.6
/330.2
120
80
100
60 80
60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]
Eff
[%]
80

70

60
/381.0
/393.7
50
/368.3
/355.6
40 /406.4
30 /330.2
TM05 9930 4513

/425.5
20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [US GPM]

194
16

Performance curves
HSEF 6-17, 2350 min-1

H p
[m] [psi] /425.5
220 HSEF 6-17
/406.4
n nom = 2350 min-1
140 200 /393.7
ANSI/HI 1.6-2000
/381.0
180 /368.3
120 /342.9
160
/355.6
100 140

120
80
100
60
80

40 60

40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
P2 P2
[kW] [hp]
/406.4
240 /425.5 /393.7
160 /381.0
200 /368.3
/355.6
/342.9
120 160

120
80
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]
Eff
[%]
80

70

60

50 /393.7
/381.0
40 /425.5 /368.3
/406.4
30 /355.6
/342.9
TM05 9940 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

195
16
Performance curves

HSEF 6-18, 1770 min-1

H p
[m] [psi]
HSEF 6-18
160
n nom = 1770 min-1
/444.5
ANSI/HI 1.6-2000
100 140 /425.5

120
80 /311.2

100

60
80

60
40

40

20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
200 /444.5
/425.5
120 160
/311.2
120
80

80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
80
/444.5
70 /425.5
/311.2
60

50

40

30
TM05 9903 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

196
16

Performance curves
HSEF 8-13, 1760 min-1

H p
[m] [psi]
90
HSEF 8-13
60 n nom = 1760 min-1
80 /330.2 ANSI/HI 1.6-2000

50 70
/304.8

60
40 /279.4

50
/247.7
30
40

30
20

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
100 140
/330.2
120
80
100 /304.8
60 80 /247.7
60
40 /279.4
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]
Eff
[%]
90

80

70
/330.2
/247.7 /304.8
60 /279.4

50

40
TM05 9904 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [US GPM]

197
16
Performance curves

HSEF 8-14, 2950 min-1

H p
[m] [psi]
280 /370.8 HSEF 8-14
180 260 n nom = 2950 min-1
/366.7 ANSI/HI 1.6-2000
240
160
220

140 200
/342.9
180
120
160
/304.8
100 140

120 /254.0
80
100
60
80

40 60

40
20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
600
400
500 /370.8

300 400 /366.7

300 /342.9
200
/304.8
200 /254.0
100
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
80
/370.8
70 /366.7
/254.0 /304.8 /342.9
60

50

40

30
TM05 9959 4513

20

10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

198
16

Performance curves
HSEF 8-15, 1760 min-1

H p
[m] [psi]
110
/393.7 HSEF 8-15
n nom = 1760 min-1
70 100 /368.3 ANSI/HI 1.6-2000
90
60 /342.9
80

50 /317.5
70
/295.4
60
40
50
30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
240
160 /393.7
200
/368.3
120 160 /342.9

120 /317.5
80 /295.4
80
40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
90

80 /393.7
/342.9 /368.3
/295.4 /317.5
70

60

50

40
TM05 9905 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

199
16
Performance curves

HSEF 8-15A, 2100 min-1

H p
[m] [psi]
180
HSEF 8-15A
120 /406.4 n nom = 2100 min-1
160 ANSI/HI 1.6-2000

/393.7
100 140 /368.3

120 /339.9
80

100

60
80

60
40

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 P2
[kW] [hp]
450
300 /406.4
400
350 /393.7
250
/368.3
300
200
250 /339.9

150 200
150
100
100
50
50
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
Eff
[%]
90 /406.4
/393.7
80 /368.3
/339.9
70

60

50

40
TM05 9929 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]

200
16

Performance curves
HSEF 8-15G, 1470 min-1

H p
[m] [psi]
HSEF 8-15G
80
n nom = 1470 min-1
/387.4 ANSI/HI 1.6-2000
50 70
/358.9
60
40

50
/308.1
30
40

30
20

20

10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
100

/387.4
60 80
/358.9

60
40 /308.1
40
20
20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
Eff
[%]
90 /387.4
80 /358.9
/308.1
70

60

50

40
TM05 9882 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]

201
16
Performance curves

HSEF 8-15G, 1780 min-1

H p
[m] [psi]
110 HSEF 8-15G
/387.4
n nom = 1780 min-1
70 100
ANSI/HI 1.6-2000
/358.9
90
60
80
/317.5
50 70

60
40 /279.4

50
30
40

20 30

20
10
10

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
160

140 /387.4
100
/358.9
120
80
100 /317.5

60 80
/279.4
60
40
40
20
20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]
Eff
[%]
90
/387.4
80 /317.5 /358.9
70 /279.4

60

50

40
TM05 9906 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

202
16

Performance curves
HSEF 8-15G, 2100 min-1

H p
[m] [psi]
HSEF 8-15G
160
n nom = 2100 min-1
/387.4 ANSI/HI 1.6-2000
100 140
/358.9

120
80
/317.5
100

60
80 /279.4

60
40

40

20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
250
/387.4
/358.9
150 200

/317.5
150
100
/279.4
100
50
50

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90
/387.4
80 /358.9
/317.5
70 /279.4

60

50

40
TM05 9928 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

203
16
Performance curves

HSEF 8-17A, 1460 min-1

H p
[m] [psi]
70 100
HSEF 8-17A
/457.2
n nom = 1460 min-1
/431.8
90 ANSI/HI 1.6-2000
60
80
/396.8
50 70

60 /349.3
40
50

30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 P2
[kW] [hp]
240
160 /457.2
200
/431.8
120 160
/396.8
120
80
/349.3
80
40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%] /349.3
90
/457.2
80 /431.8
/396.8
70

60

50

40
TM05 9984 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

204
16

Performance curves
HSEF 8-17A, 1780 min-1

H p
[m] [psi]
140
/457.2 HSEF 8-17A
/431.8
130 n nom = 1780 min-1
90
ANSI/HI 1.6-2000
120 /406.4
80
110
/381.0
70 100

90 /355.6
60
80 /330.2

50 70
/304.8
60
40
50
30
40

20 30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]

300 400
/457.2
/431.8
300
200 /406.4
/381.0
200
/355.6
/330.2
100
/304.8
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
Eff
[%]
90
/457.2
/406.4
80 /431.8
/304.8 /330.2 /381.0
70 /355.6

60

50

40
TM05 9908 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

205
16
Performance curves

HSEF 8-17Q, 1470 min-1

H p
[m] [psi]
70 100
HSEF 8-17Q
/431.8 n nom = 1470 min-1
90 ANSI/HI 1.6-2000
60
80 /406.4

50 70 /381.0

60 /355.6
40
50

30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 P2
[kW] [hp]
200

120 160 /431.8

/406.4
120
80 /381.0
80 /355.6

40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
Eff
[%]
90

80 /431.8
/406.4
/355.6 /381.0
70

60

50

40
TM05 9885 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]

206
16

Performance curves
HSEF 8-17Q, 1780 min-1

H p
[m] [psi]
140 /431.8 HSEF 8-17Q
130 n nom = 1780 min-1
90
ANSI/HI 1.6-2000
120
/406.4
80
110
/381.0
70 100

90 /355.6
60
80

50 70

60
40
50
30
40

20 30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
300 /431.8
200
250
/406.4
150 200 /381.0

150 /355.6
100
100
50
50

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]
Eff
[%]
90
/431.8
80 /355.6 /381.0 /406.4

70

60

50

40
TM05 9909 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

207
16
Performance curves

HSEF 8-17Q, 2100 min-1

H p
[m] [psi]
180
HSEF 8-17Q
120 n nom = 2100 min-1
160 /400.1 ANSI/HI 1.6-2000

100 /381.0
140

/355.6
120
80

100

60
80

60
40

40
20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
350 /400.1
250
/381.0
300
200
250 /355.6

150 200

150
100
100
50
50

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]
Eff
[%]
90
/400.1
80 /381.0
/355.6
70

60

50

40
TM05 9927 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

208
16

Performance curves
HSEF 8-17SS, 1460 min-1

H p
[m] [psi]
70 100
HSEF 8-17SS
/457.2
n nom = 1460 min-1
/431.8
90 ANSI/HI 1.6-2000
60
80
/396.8
50 70

60 /349.3
40
50

30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 P2
[kW] [hp]
240
160 /457.2
200
/431.8
120 160
/396.8
120
80
/349.3
80
40
40

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%] /349.3
90
/457.2
80 /431.8
/396.8
70

60

50

40
TM058983 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

209
16
Performance curves

HSEF 8-17SS, 1780 min-1

H p
[m] [psi]
HSEF 8-17SS
160 n nom = 1780 min-1
ANSI/HI 1.6-2000
100 /457.2
140
/431.8

120 /406.4
80
/381.0
100
/355.6
60
80 /330.2

/304.8
60
40

40

20
20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]

300 400
/457.2
/431.8
300
200 /406.4
/381.0
200 /355.6
/330.2
100
/304.8
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]
Eff
[%]
90
/406.4 /457.2
80 /381.0
/304.8 /330.2 /431.8
/355.6
70

60

50

40
TM05 9907 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000Q [US GPM]

210
16

Performance curves
HSEF 8-17W, 1770 min-1

H p
[m] [psi]
90
130 HSEF 8-17W
/431.8
n nom = 1770 min-1
120
ANSI/HI 1.6-2000
80 /406.4
110

70 100 /381.0

90
60
80

50 70

60
40
50
30
40

20 30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
160
/381.0
100 140 /406.4
/431.8
120
80
100

60 80

60
40
40
20
20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90
/381.0
80 /406.4
/431.8
70

60

50

40
TM05 9910 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

211
16
Performance curves

HSEF 8-17W, 2100 min-1

H p
[m] [psi]
180 /431.8
HSEF 8-17W
120 n nom = 2100 min-1
160 ANSI/HI 1.6-2000
/406.4

100 140 /381.0

120 /330.2
80

100

60
80

60
40

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
300
200 /431.8
250 /406.4
/381.0
150 200 /330.2

150
100
100
50
50

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90 /330.2
/381.0
/406.4
80 /431.8
70

60

50

40
TM05 9926 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

212
16

Performance curves
HSEF 8-17Wuc, 1780 min-1

H p
[m] [psi]
140 HSEF 8-17Wuc
/457.2
n nom = 1780 min-1
130
90 /431.8 ANSI/HI 1.6-2000
120
80 /406.4
110

70 100

90
60
80

50 70

60
40
50
30
40

30
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

0 100 200 300 400 500 600 700 Q [m³/h]


P2 P2
[kW] [hp]
240
160 /457.2
200

120 160 /431.8


/406.4
120
80
80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]
Eff
[%]
90
/406.4 /457.2
/431.8
80

70

60

50

40
TM05 9911 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

213
16
Performance curves

HSEF 8-17Wuc, 2100 min-1

H p
[m] [psi]
140 200
HSEF 8-17 Wuc
/457.2 n nom = 2100 min-1
180 ANSI/HI 1.6-2000
120 /431.8
160

100 140

120
80
100

60
80

40 60

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
250 350 /457.2

300
200
250
/431.8
150 200

150
100
100
50
50

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90
/457.2
80
/431.8
70

60

50

40
TM05 9925 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

214
16

Performance curves
HSEF 8-20, 1470 min-1

H p
[m] [psi]
120
/489.0
HSEF 8-20
80
110 n nom = 1470 min-1
ANSI/HI 1.6-2000
/457.2
70 100

90 /431.8
60
/406.4
80

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

0 100 200 300 400 500 600 Q [m³/h]


P2 P2
[kW] [hp]
160 /489.0

100 140
/457.2
120
/431.8
80
100 /406.4

60 80

60
40
40
20
20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]
Eff
[%]
90

80 /489.0

70 /457.2
/431.8
60
/406.4
50

40
TM05 9886 4513

30

20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [US GPM]

215
16
Performance curves

HSEF 8-20, 1780 min-1

H p
[m] [psi]
180
HSEF 8-20
/489.0 n nom = 1780 min-1
120
160 ANSI/HI 1.6-2000
/457.2
100 140
/431.8

120 /406.4
80

100

60
80

60
40

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
200 280 /489.0

240 /457.2
160
200 /431.8
/406.4
120 160

120
80
80
40
40

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90

80
/489.0
70
/457.2
60 /406.4 /431.8
50

40
TM05 9912 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

216
16

Performance curves
HSEF 8-20, 2100 min-1

H p
[m] [psi]
240 /482.6
HSEF 8-20
160
220 n nom = 2100 min-1
/457.2 ANSI/HI 1.6-2000
140 200
/431.8
180
120 /406.4
160

100 140

120
80
100
60
80

40 60

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
500
/482.6
300 400 /457.2
/431.8
300 /406.4
200

200
100
100

0 0
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]
Eff
[%]
80 /482.6
/457.2
/406.4
70 /431.8

60

50

40

30
TM05 9924 4513

20

10
0 400 800 1200 1600 2000 2400 2800 3200 Q [US GPM]

217
16
Performance curves

HSEF 8-20G, 1470 min-1

H p
[m] [psi]
90
130 /508.0 HSEF 8-20G
120 n nom = 1470 min-1
/482.6
80 ANSI/HI 1.6-2000
110
/457.2
70 100
/431.8
90
60 /406.4
80

50 70

60
40
50
30
40

20 30

20
10
10
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

0 100 200 300 400 500 600 700 800 Q [m³/h]


P2 P2
[kW] [hp]
240 /508.0
160
200 /482.6
/457.2
120 160 /431.8
/406.4
120
80
80
40
40

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
Eff
[%]
90

80

70
/406.4 /482.6 /508.0
60 /431.8
/457.2
50

40
TM05 9887 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]

218
16

Performance curves
HSEF 8-20G, 1780 min-1

H p
[m] [psi]
140 200
HSEF 8-20G
508.0 n nom = 1780 min-1
180 ANSI/HI 1.6-2000
120 /482.6
160
/457.2

100 140 /431.8

/406.4
120
80
100

60
80

40 60

40
20
20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]

0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 P2
[kW] [hp] /508.0
400
280
350 /482.6
240
300 /457.2
200 /431.8
250
/406.4
160
200
120
150
80 100

40 50
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]
Eff
[%]
90

80

70 /457.2 /508.0
/431.8 /482.6
60 /406.4
50

40
TM05 9913 4513

30

20
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]

219
16
Performance curves

HSEF 8-20G, 2100 min-1

H p
[m] [psi]
220 /463.6
HSEF 8-20G
n nom = 2100 min-1
140 200
/431.8 ANSI/HI 1.6-2000
180
120 /406.4
160

100 140

120
80
100
60
80

40 60

40
20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 200 400 600 800 1000 Q [m³/h]


P2 P2
[kW] [hp]
600
400
500 /463.6
/431.8
300 400
/406.4

300
200
200
100
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]
Eff
[%]
80

70 /463.6

60
/431.8
/406.4
50

40

30
TM05 9923 4513

20

10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

220
16

Performance curves
HSEF 10-16, 1775 min-1

H p
[m] [psi]
140
/406.4
HSEF 10-16
90 130 n nom = 1775 min-1
ANSI/HI 1.6-2000
120
/378.0
80
110

70 100

90 /330.2
60
80

50 70

60
40
50
30
40

20 30

20
10
10
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

0 400 800 1200 1600 2000 Q [m³/h]


P2 P2
[kW] [hp]
450
320 /406.4
400
280
350
240 /378.0
300
200
250
160 /330.2
200
120
150
80 100
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
Eff
[%]
90

80 /330.2 /406.4
70 /378.0

60

50

40
TM05 9888 4513

30

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

221
16
Performance curves

HSEF 10-16, 1900 min-1

+ S
>P@ >SVL@

+6()
 QQRP PLQ
 $16,+,


 
















 
               4>86*30@

          4>PñK@
3 3
>N:@ >KS@





 

 





 
               4>86*30@
(II
>@


 








TM05 9921 3614




               4>86*30@

222
16

Performance curves
HSEF 10-20, 1470 min-1

H p
[m] [psi]
140 /508.0 HSEF 10-20
130 n nom = 1470 min-1
90
/482.6 ANSI/HI 1.6-2000
120
80
110

70 100 /425.5

90
60
80

50 70

60
40
50
30
40

20 30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0 200 400 600 800 1000 1200 Q [m³/h]


P2 P2
[kW] [hp]
350
250 /508.0
300
200 /482.6
250

150 200 /425.5

150
100
100
50
50
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
Eff
[%]
90

80

70

60 /482.6
/425.5 /508.0
50

40
TM05 9878 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

223
16
Performance curves

HSEF 10-20, 1780 min-1

H p
[m] [psi]
220 HSEF 10-20
/508.0 n nom = 1780 min-1
140 200
ANSI/HI 1.6-2000
180
120
160

100 /425.5
140

120
80 /368.3
100
60
80

40 60

40
20
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]

0 200 400 600 800 1000 1200 1400 Q [m³/h]


P2 P2
[kW] [hp]
600 /508.0
400
500

300 400
/425.5
300
200
/368.3
200
100
100

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]
Eff
[%]
90

80

70
/425.5
60 /508.0

50

40 /368.3
TM05 9889 4513

30

20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]

224
16

Performance curves
HSEF 10-20, 1900 min-1

+ S
>P@ >SVL@


+6()
 QQRP PLQ

$16,+,
  



 
 







 





 
            4>86*30@

        4>PñK@


3 3
>N:@ >KS@
 


 


  

 





 
            4>86*30@
(II
>@





 





TM05 9922 3614




            4>86*30@

225
16
Performance curves

HSAF 12-19G, 1480 min-1

H p
[m] [psi]
90 130 /482.6 HSAF 12-19G
120 n nom = 1480 min-1
80 ANSI/HI 1.6-2000
110

70 100
/406.4
90
60
80 /393.7

50 70

60
40
50
30
40

20 30

20
10
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500Q [US GPM]

0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
P2 P2
[kW] [hp] /482.6
450
300 400

250 350

300 /406.4
200 /393.7
250

150 200

150
100
100
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500Q [US GPM]
Eff
[%]
90

80

70

60

50 /482.6

40
TM05 9879 4513

30
/393.7 /406.4
20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500Q [US GPM]

226
16

Performance curves
HSAF 12-19G, 1760 min-1

H p
[m] [psi]
140 200
HSAF 12-19G
n nom = 1760 min-1
/482.6
180 ANSI/HI 1.6-2000
120
160

100 140
/406.4

120
80 /393.7
100

60
80

40 60

40
20
20

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

0 400 800 1200 1600 2000 Q [m³/h]


P2 P2
[kW] [hp]
800
/482.6
500 700

600
400
500 /406.4
/393.7
300 400

300
200
200
100
100
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
Eff
[%]
90

80
/482.6
70

60
/393.7 /406.4
50

40
TM05 9890 4513

30

20
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]

227
16
Performance curves

HSMF 4-5-2, 1760 min-1

H p
[m] [psi]
140 200
HSMF 4-5-2
/355.6 n nom = 1760 min-1
180 ANSI/HI 1.6-2000
120
160

100 140

120 /285.8
80
100

60
80

40 60

40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

0 50 100 150 200 Q [m³/h]


P2 P2
[kW] [hp]
120
80 /355.6
100

60 80

60
40 /285.8
40
20
20

0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
Eff
[%]
80

70

60 /355.6
/285.8
50

40

30
TM05 9914 4513

20

10
0 100 200 300 400 500 600 700 800 900 Q [US GPM]

228
16

Performance curves
HSMF 4-11-2, 2800 min-1

H p
[m] [psi]
HSMF 4-11-2
320 /292.1
n nom = 2800 min-1
ANSI/HI 1.6-2000
200 280
/266.7

240
160

200 /225.6

120
160

120
80

80

40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
200 /292.1

120 160
/266.7

120
80
/225.6
80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
70

60

50 /292.1
40
/225.6 /266.7
30

20
TM05 9949 4513

10

0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

229
16
Performance curves

HSMF 4-11-2, 2950 min-1

H p
[m] [psi]
360
HSMF 4-11-2
240
/292.1 n nom = 2950 min-1
320 ANSI/HI 1.6-2000

/266.7
200 280

240
160 /225.6
200

120
160

120
80

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
250
/292.1
150 200
/266.7
150
100

100 /225.6

50
50

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
70

60

50 /292.1

40
/225.6 /266.7
30
TM05 9960 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

230
16

Performance curves
HSMF 4-11-2, 3000 min-1

H p
[m] [psi]
360 /292.1
HSMF 4-11-2
240 n nom = 3000 min-1
320 ANSI/HI 1.6-2000
/266.7
200 280

240
160 /225.6

200

120
160

120
80

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
200 280

240 /292.1
160
200
/266.7
120 160

120
80 /225.6
80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
70

60

50 /292.1

40
/225.6 /266.7
30
TM05 9970 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

231
16
Performance curves

HSMF 4-14-3, 1750 min-1

+ S
>P@ >SVL@
 +60)

 QQRP PLQ

$16,+,




  





 







 


          4>86*30@

     4>PñK@


3 3
>N:@ >KS@


 



 

 






          4>86*30@
(II
>@






 




TM06 1526 2514




          4>86*30@

232
16

Performance curves
HSMF 5-7-2, 1760 min-1

H p
[m] [psi]
220
HSMF 5-7-2
n nom = 1760 min-1
/381.0 ANSI/HI 1.6-2000
140 200

180
120
160

100 140

120 /300.0
80

100

60
80

60
40

40
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
160

140 /381.0
100
120
80
100

60 80
/300.0
60
40
40
20
20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70

60 /381.0
/300.0
50

40

30
TM060249 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

233
16
Performance curves

HSMF 5-7-2, 2100 min-1

+ S
>P@ >SVL@

+60)
  QQRP PLQ
$16,+,
















 
         4>86*30@

         4>PñK@


3 3
>N:@ >KS@
 



 

 





 
         4>86*30@
(II
>@











TM05 9935 3614




         4>86*30@

234
16

Performance curves
HSMF 5-13B-2, 2800 min-1

H p
[m] [psi]
HSMF 5-13B-2
400 /355.6
n nom = 2800 min-1
ANSI/HI 1.6-2000
250 350

300
200

250
/249.2
150
200

150
100

100

50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
250 350 /355.6

300
200
250

150 200

150 /249.2
100
100
50
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70
/355.6
60

50 /249.2

40

30
TM05 9950 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

235
16
Performance curves

HSMF 5-13B-2, 2950 min-1

H p
[m] [psi]
440 /330.2
HSMF 5-13B-2
n nom = 2950 min-1
280 400
ANSI/HI 1.6-2000
360
240
320

200 280
/249.2
240
160
200
120
160

80 120

80
40
40

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
400 /330.2

250 350

300
200
250

150 200
/249.2
150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70
/330.2
60
/249.2
50

40

30
TM05 9961 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

236
16

Performance curves
HSMF 5-13B-2, 3000 min-1

H p
[m] [psi]
320 450 /330.2
HSMF 5-13B-2
n nom = 3000 min-1
280 400 ANSI/HI 1.6-2000

350
240

300
200
/249.2
250
160
200
120
150

80
100

40 50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 100 200 300 400 Q [m³/h]


P2 P2
[kW] [hp]
450
/330.2
300 400

250 350
300
200
250
150 200 /249.2
150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70
/330.2
60

50 /249.2

40

30
TM060098 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

237
16
Performance curves

HSMF 5-16B-3 HR, 1775 min-1

H p
[m] [psi]
440 HSMF 5-16B-3 HR
/431.8 n nom = 1775 min-1
280 400
ANSI/HI 1.6-2000
360
240
/382.5
320

200 280

240
160
200
120
160

80 120

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0 50 100 150 200 250 300 350 Q [m³/h]


P2 P2
[kW] [hp]
400 /431.8

250 350
300
200
250 /382.5

150 200
150
100
100
50
50
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]
Eff
[%]
80
/431.8
70
/382.5
60

50

40

30
TM05 9916 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

238
16

Performance curves
HSMF 5-16B-3 LR, 1775 min-1

H p
[m] [psi]
280 400
HSMF 5-16B-3 LR
n nom = 1775 min-1
360 ANSI/HI 1.6-2000
/406.4
240
320

200 280

240 /330.2
160
200

120
160

80 120

80
40
40

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
300
200 /406.4
250

150 200

150
100 /330.2
100
50
50

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]
Eff
[%]
80

70
/330.2
60 /406.4

50

40

30
TM05 9917 4513

20

10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

239
16
Performance curves

HSMF 5-16B-3 high range, 1775 min-1

H p
[m] [psi]
320 450
HSMF 5-16B-3 High Range
n nom = 1775 min-1
/436.4
280 400 ANSI/HI 1.6-2000
/432.1

350
240

300
200

250
160
200
120
150

80
100

40 50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 50 100 150 200 250 300 350 400 Q [m³/h]


P2 P2
[kW] [hp]
450
300 /436.4
400
/432.1
250 350
300
200
250
150 200
150
100
100
50
50
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
Eff
[%]
80

70 /436.4
/432.1
60

50

40

30
TM05 9918 4513

20

10
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

240
16

Performance curves
HSMF 6-10-2, 1775 min-1

+ S
>P@ >SVL@
 +60)

 QQRP PLQ

$16,+,

 





 








 




               4>86*30@

        4>PñK@


3 3
>N:@ >KS@



 




 




 
               4>86*30@
(II
>@


 
 





TM05 9919 4513




               4>86*30@

241
16
Performance curves

HSMF 8-15-2, 1770 min-1

+ S
>P@ >SVL@
 +60)
 QQRP PLQ
 
$16,+,





 







 





 
            4>86*30@

            4>PñK@
3 3
>N:@ >KS@
 



 
 







 
            4>86*30@
(II
>@




 






TM06 2092 3614




            4>86*30@

242
16

Performance curves
HSMF 8-15-6, 1750 min-1

H p
[m] [psi]
600 HSMF 8-15-6
400 n nom = 1750 min-1
550
/381.0 ANSI/HI 1.6-2000

350 500
/355.6
450
300
400

250 350

300
200
250
150
200

100 150

100
50
50
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0 50 100 150 200 250 300 Q [m³/h]


P2 P2
[kW] [hp]
/381.0
300 400

250 350 /355.6


300
200
250
150 200
150
100
100
50
50
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]
Eff
[%]
90
/381.0
80
/355.6
70

60

50

40
TM05 9920 4513

30

20
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

243
ECM: 1146723
98777372 1114

GRUNDFOS A/S

www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. © Copyright Grundfos Holding A/S

You might also like