A1 A B C D E F G H I J K L M N

21/04/2023 16:27:29
This drawing is the property of ARUP (Mauritius Ltd) and cannot be
H J K reproduced, copied or modified without the permission of the company.

Architect drawing number:


Beach Club REVIT model dated 18.10.2022

1 LEGEND

Direction of flow
Concrete plinth for Access panel
10 10 fresh air fan Dimension on drawing
Axial Extract Fan
EAF-01 Circular sound attenuator

600 Mechanical control panel

11 Opening in slab MCP For deli Mechanical


11 425 mmø
500
Ventilation fan c/w supports
and fittings
500x450mm (LxW) Equipment

Concrete plinth for AC

AC-01
2 Isolator (SP&N)

1100
outdoor unit

1500
Axial Extract Fan VRF outdoor unit
EAF-03
450
MCP-04 MCP-03 Opening in slab
650x450mm (LxW)
500 Split type outdoor unit

600
150 mmø
250 mmø
Extract Duct

650
Dim:300x300 Power point for
Concrete plinth for fresh air fan
mechanical equipment

AC-02

1100
Fresh Air Intake c/w
insectproof wiremesh Axial Supply Fan 250 mmø
AC-05 FAF-01 Flexible duct

1100
400
1100 MCP 01
12 EAF-05 FAF-04 12
1

500
Cable Tray AC-03
for Power & Refrigerant pipe GMS Fresh air duct

400
3
Isolator (SP&N)
12
500 mmx400 mm 600 mmx500 mm 1100 Concrete Plinth for AC
GMS Extract air duct

1900
VRV-01 outdoor unit
1400 Dim: 1100x500x100
600
13 400 mmx400 mm
13 500 (L x W x H)
GMS Kitchen extract air duct

600
700

600

600 mmx500 mm
Cold room unit

500 mmx450 mm
600
1350
6 Refrigerant pipe c/w 19mm
thick closed cell insulation
Concrete Plinth for AC 700 mmx700 mm
outdoor unit
Dim: 1900x1100x100 3000

Cold room unit


(L x W x H) Inline Centrifugal Fan
FAF-03
GENERAL NOTES:
4
1. This drawing should be read in conjunction with all other tender

1200
700 mmx600 mm
14 14 ROOF - Change Room documentation including specification, data sheets, schematics
and engineering preliminaries.
WL-01
900 3 1 : 50

900 mmø
2. This drawing should be read in conjunction with all related
Architects, Structural, Electrical,Mechanical and Public Health
G

600
EAF-06 drawings.

500
AC-11 AC-12 AC-13
Inline Centrifugal Fan
15 EAF-03
1100 1100 1100 15 3. Do not scale from this drawing - refer to Architect's drawings for
building and dimensional information.

MCP for kitchen @ high level for Concrete plinth for


Mechanical Equipment AC outdoor unit
SPECIFIC NOTES:

5 1. All control panel to be IP66.


F G H J K Air Handling Unit
12
1
AHU
Dim:2400x1200x1200mm(LxWxH)
Concrete base
12
Dim:2600x1400x1000(LxWxH)

ROOF - Main Kitchen & Deli


1 1 : 75
Supply Air Duct
Dim:700x500mm(LxW)
Return Air Duct
Dim:600x500mm(LxW) 13
Opening to be provided in beam Opening to be provided in beam

M N P
6
6 6 Air Handling Unit
Dim:2400x1200x1200mm(LxWxH)
Heat Pump for swimming pool Concrete Base:2600x1400x100mm(LxWxH) Heat Pump for Swimming pool C00 24/04/23 WB/DSa FH PN
Dim:990x990x1800mm(LxWxH) Capacity:56 kW
VRV Outdoor pool Dim:990x990x1800(LxWxH) FOR CONTRACT
125 mmø
1500
125 mmø
Dim:1240x760x1760mm(LxWxH)
Capacity:56.0 kW VRV 02
14 Rev Date By Chkd Appd
Capacity:56.0 kW
Dim:1240x760x1760mm
(LxWxH)
400

1950

1860
1500

Concrete Plinth for 7


fresh air fan
M-4502
15
350

MCP-02 Fresh Air Duct


Axial Supply Fan
FAF-02
500
7 Opening in slab for refrigerant pipes
300

and control cables AHU and VRV Control Panel


Opening in slab Dim:500x300mm(LxW)
500x350mm (LxW) Dim:400x400(LxW)
175 Dog House to be provided
7 7
Concrete Plinth for
M N P Q Client
200 mmø

AC outdoor unit
Section 7 KERNER INTERNATIONAL
7
AC-04

1100

1 : 100

500

Axial extract Fan ROOF - AHU plant area Q


2000

Project Title
8
Isolator (SP&N)
EAF-02
6 1 : 75 ONE & ONLY
LE SAINT GERAN
FIRST FLOOR - FAN SCHEDULE
8 8 FLOW RATE PRESSURE POWER SUPPLY TWO SPEED SOUND PRESSURE DIMENSION
600 No. REFERENCE CONNECTED TO FAN LOCATION DESCRIPTION CONTROL RPM WEIGHT /kg NOTE
(m3/h) DROP / Pa (kWe/Ph/V/Hz) OPTION LEVEL (L X W X H) / mm
Concrete Plinth Key Plan
for extract air fan Box fan similar or equivalent to FranceAir Rectilys II ECM 2700 c/w 600mm long sound
YES. Fan to operate on ON/OFF delay timer c/w 1. GMS Covering for fan
1.0 EAF-01 Toilet extraction system Changing room Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 150.00 0.45 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
700.00 low speed Manual override switch 2. Fan to be mounted on anti-vibration pads
dampers

Box fan similar or equivalent to FranceAir Rectilys II ECM 800 c/w 600mm long sound
YES. Fan to operate on ON/OFF delay timer c/w 1. GMS Covering for fan
2.0 EAF-02 Toilet extraction system Kids toilet Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 150.00 0.20 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
9 dampers
200.00 low speed Manual override switch 2. Fan to be mounted on anti-vibration pads

VIEW 3
Controlled on delay timer
Kitchen ventilation - Kitchen extract fan similar to FranceAir XTA 2-630 c/w 2nos sound attenuators, bird YES. Fan to operate on 1. Speed control regulator to be provided
3.0 EAF-03 Kitchen Roof 400.00 9.20 / 3Ø / 400 / 50 and Manual override for 1400 45 2115 x 1875 x 1215 507
Main ventilation canopy protection grille. Fan to be used for smoke extraction rated 300deg / 2hrs 11,988.00 low speed 2. Two speed option
ON/OFF
D E
Box fan similar or equivalent to FranceAir Rectilys II ECM 800 c/w 600mm long sound
Restaurant toilet YES. Fan to operate on ON/OFF delay timer c/w 1. GMS Covering for fan VIEW 2
4.0 EAF-04 Toilet extraction system Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 150.00 0.20 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
block 450.00 low speed Manual override switch 2. Fan to be mounted on anti-vibration pads
ROOF - Bicycle store dampers

2 1 : 50 Kitchen ventilation - Controlled on delay timer


VIEW 1

Kitchen extract fan similar to FranceAir SIMOUN 315 c/w 2nos sound attenuators, bird YES. Fan to operate on 1. GMS Covering for fan
5.0 EAF-05 Pastry & Finishing Kitchen Roof 200.00 0.12 / 1Ø / 230 / 50 and Manual override for 1410 45 616 x 415 x 470 15
protection grille. Fan to be used for smoke extraction rated 300deg / 2hrs 1,188.00 low speed 2. Fan to be mounted on anti-vibration pads
canopy ON/OFF
GMS Covered cable tray Refrigerant pipework c/w 19mm thick Drawing Title
Min Height:75mm closed cell insulation and painted with
10 anti uv-paint Kitchen ventilation - Controlled on delay timer
BEACH CLUB
Width:Vary to number of Kitchen extract fan similar to FranceAir SIMOUN 400 c/w 2nos sound attenuators, bird YES. Fan to operate on 1. GMS Covering for fan
6.0 EAF-06 Central ware wash Kitchen Roof 300.00 0.37 / 1Ø / 230 / 50 and Manual override for 1410 50 930 x 595 x 617 21
refrigerant pipes protection grille. Fan to be used for smoke extraction rated 300deg / 2hrs 3,240.00 low speed 2. Fan to be mounted on anti-vibration pads
canopy ON/OFF ROOF LEVEL
Power and
Control Cable Box fan similar or equivalent to FranceAir Rectilys II ECM 800 c/w 600mm long sound
AC & VENTILATION LAYOUT
YES. Fan to operate on ON/OFF delay timer c/w 1. GMS Covering for fan
7.0 FAF-01 Fresh air system Changing room Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 125.00 0.20 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
200.00 low speed Manual override switch 2. Fan to be mounted on anti-vibration pads
dampers

Concrete Plinth Scale at A1 By / Chkd / Appd


As indicated
100
Min

Box fan similar or equivalent to FranceAir Rectilys II ECM 800 c/w 600mm long sound JN/WB/YM
YES. Fan to operate on ON/OFF delay timer c/w 1. GMS Covering for fan
8.0 FAF-02 Fresh air system Bicycle shop Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 150.00 0.20 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
300.00 low speed Manual override switch 2. Fan to be mounted on anti-vibration pads Role
dampers
MECHANICAL
Controlled on delay timer Status
ROOF SLAB
9.0 FAF-03
Kitchen ventilation -
Kitchen Roof
Kitchen extract fan similar to FranceAir XTA 2-630 c/w 2nos sound attenuators, bird
400.00 7.5 / 3Ø / 400 / 50
YES. Fan to operate on
and Manual override for 1400 45 2115 x 1875 x 1215 507
1. Speed control regulator to be provided CONTRACT
Main ventilation canopy protection grille. Fan to be used for smoke extraction rated 300deg / 2hrs 10,188.00 low speed 2. Two speed option
ON/OFF Arup Job No Rev
11
Box fan similar or equivalent to FranceAir Rectilys II ECM 2700 c/w 600mm long sound 252208-00 C00
YES. Fan to operate on ON/OFF delay timer c/w 1. Speed control regulator to be provided
9.0 FAF-04 Kitchen ventilation Kitchen Roof attenuators at inlet and outlet, external grille, rain shield with bird protection grille and 150.00 0.45 / 1Ø / 230 / 50 1860 40 dBA @ 3m 450 x 420 x 390 14
900.00 low speed Manual override switch 2. Two speed option ID
dampers
Typical detail of Cable Tray OOLSGV-ARUP-BC-RF-DR-M-4502
5 1 : 10
Do not scale © Arup