ry
Registered Data Sheet Perforating System Evaluation, API RP 19B Section 1
‘API Form 196-Secton 1 J Conforms to Al Requirements of Section 1 1 Special Test- See Remats/Excopions below
Service Company AVAILABLE TO ALL FROM OWEN OIL TOOLS Eelosve weight 150 fm. tx power, Case Moteal_ STEEL
Gun 0D & TadeName 276° OD.TAG.O.SPF. OY 15. HEROMRISDPZris.sin) —_MaxTemp,°F 400 Var 3h x 2th 100
Charge Nome _PERFORATOR. 2750" SOP, 156, HX Maximum Pesire Rating 2500 al Carer Materiales
Manufacurer Charge Pat No. SOP2TI5-10 __Dateof Manufacture 1502019 Shot Density ested. & Souk
‘cunType SCALLOPED, EXPENDABLE, HOLLOW CARRIER Recommended Minimum 0 for Running 315° x
Phasing Tested 60 depres, Fring Order _XTopdown x Battomup Avalable Fiiog Mode:_x eecive Simuaneous
Debris Description _ SMALL STEEL PIECES. DebrisWeigh: _X ‘arvcharge, “Debes _X inveharge
ROX VERSION AVAILABLE AS SOP.2715.310,
Remarks/Exceptions per Section 1.1
casing Data 4.5" 00, Weight 14.6 lot, AP.Grade, 1-80 Date of ection 1 Test 7-8-2013
TargetData 96" (00, Amount of Cement B56 b, Amount of ane 16.920 Ib, Amount of Water 4420.02
Date of Compressive Suength Test 7-8-2013, Briquetie Compressive Strength6,527 Ps Age of Target 28
Shot No No3 Nod NoS_— No.6 = CNOT No BNO
Clearance, in 86 as os oz 200 026 296
Casing Hole Diameter, Short Ax 028 ozs ow. ox 038 oa 028
Casing Hole Diameter, Long Asn 030 25 ox 238 ox 03 ow
‘Average Casing Hole Diameter in om ozs oat ron 2 ay om
Total Depth in Lost 10. a 355 0. 2 my
Burr Height in aoe oma 2083 aaa «000
Shot No No1s —No19.——No20 Average
‘Clearance, in. 026 XXX,
Casing Hole Diameter, Shor Axis in oan ast
Casing Hole Diameter, Long Asn ous oz
Average Casing Hole Diameter in. 042 oa
Total Depth, in. 84
Burr Height in 007
Remarks
Manufacturer's Certification
“Type of Certiction: ‘Se Truda Stevens Thid Party
| certty that these tests were made according to the procedures as outlined in API 19B: Recommended Practice for Evaluation of Well Perorators, Second Editon, September 2006. Al ofthe equipment used
in these tests, suchas the guns, jet charges detonator cor, etc, was standard equipment with our company forthe use in the gun being tested and was not changed in any manner for the test. Furthermore,
the equipment was chosen at random ftom stock and therefore wil be substantially the same asthe eculpment that would be furnished to perforate a well for any operater. API nether endorses these tests
nor recommends the use ofthe perforatoreygtem described.
x CERTIFIED BY Matthew ee Z 2 DR salisiestnsnonna Manaser 7-16-2013, ‘Owen OllTools 12001 CR 1000, Godley, Tx 76044
RECERTIFIED (Company Offa Tite) (ate (Company) taaavess)
Name oftest a t should appear on webste. 23/4" OD, TAG, 6 SPF, 60°, 15.0g, HERO-HR (SDP-2715-410)
"Name oft a appears on aplication and appicaton cat: .2 9/4" OD, TAG, 6 SPF. 60°, 15.03, HERO-HR (SDP-2715-410