Forklift
ETSONE - X000425

X1 DANGER!
1 Do not connect voltage from a
VBAT+ C201020/RD Fused (1A) power supply (12V-24V)*
preinstalled DC/DC converter
+
CAN1L 2 -
---
DANGER!
CAN2L 3 Always connect input and output signals
---
with the same negative potential
120Ω

VBAT- 4 C201020/BU
* WARNING!

2
5 DO NOT connect directly to battery.
CAN1H --- Connect to a fused (1A) power source.
6 Always connect in accordance to 2006/42/EC
CAN2H ---
ECU WARNING:
Immobilizer signal must be a dedicated port!
Seat switch interruption,
X2 Key switch signal (+)
Key switch interruption, etc.
1 are NOT valid immobilizer signals!
5V C201020/WH
2 C201020/GY Immobilizer COM
RL1 3 C201020/GY
Immobilizer N.O.
4 ---

3
RL2 5 ---

GND 6
---

IP1 7
C201020/PK
X3 Current sensor X200601
IP2 8
--- 1

IP3 9
--- 2

IP4/AI 10 3
C201020/VT

4 OPTIONAL RS232 iButton reader G000030 + G000040

Kiwitron s.r.l. ETS One installation scheme Drawn 29/07/2021 Daniele Parazza REV.
Via Vizzano 44
Approved 08/11/2021 Daniele Parazza
0
Verified
Sasso Marconi 40037 ETS One installation scheme easy 11-2021
Bologna, Italy PAG.
01