Professional Documents
Culture Documents
MEDC DB3 Data Sheet
MEDC DB3 Data Sheet
Ex d(e), Weatherproof
Features
Ex d / Ex de IIC/IIIC T4/T5/T6.
ATEX certified.
IECEx certified.
UL listed for USA and Canada
Class I, Div 2, Groups A-D
Class I, Zone 1, Ex d IIC/AEx d IIC Gb
Class II, Div 2, Groups F & G
Zone 21, AEx tb IIIC
Class III, Div. 1
Fire alarm and general use
CUTR Certified.
CQST Certified.
Brazilian (Inmetro) certified.
Certified temperature -55ºC to +70ºC.*
IP66 & IP67/NEMA 4X & 6.
Optional Ex e terminal chamber.
Up to 125dB output @ 1m.
Integral volume control.
28 tones, user selectable.
3 stage unit remotely switchable.
Tones can be programmed to customer’s
specification.
The unit is provided with versatile control options allowing compatibility with Optional swivel bracket available.
a wide range of control methods and PLCs. The standard DC unit provides
3 tone stages, each stage has 28 tones available which can be independently
*Model Dependent.
selected. The unit can be controlled by reversing the polarity of the power
supply (2 stage) or providing a common negative and switching between
multiple positive supplies. The DB3B proves its versatility by additionally
Short Flare Version
being able to work with a common positive supply and switching the
negatives. The tone stages of the DB3B can also be controlled via voltage
free contacts provided by a control panel.
The flexibility of the range continues with a wide range of supply voltages.
The short flare option is a worthy addition to the range offering a high SPL in
a compact unit.
ATEX Ex d Gas & Dust: Cert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31.
30 ±1
POS. 1
Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. 19°
143 ±2
200 ±2
ATEX Ex de Gas: Cert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7. POS. 3
19°
Ex II 2G, Ex de IIC T4/T5/T6 Gb.
30 ±1
POS. 2
ATEX Ex de Gas & Dust: Cert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31.
Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. 2 ENTRIES MAX. FIXING HOLE FIXING HOLES
13 ±1
IECEx Ex d Gas: Cert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1. 185 ±2 9 ±1
2 POSITIONS
Ex d IIC T4/T5/T6 Gb. Ex de SHORT FLARE VERSION
WITH OPTIONAL SWIVEL BRACKET
IECEx Ex d Gas & Dust: Cert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31. 255.5 3
323.5 3 FOR LONG FLARE VERSION
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. 230 ±2 37 ±1 147.5 2 25°
IECEx Ex de Gas: Cert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7.
Ex de IIC T4/T5/T6 Gb.
IECEx Ex de Gas & Dust: Cert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31.
145.5 ±2
30° 25°
Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number
by inserting the code for each component into the appropriate box.
Model Certification Ex Atmosphere Voltage Labels Entries Options Finish
DB3B
Certification Code Ex Atmosphere Code Voltage Code Labels Code Entries Code Options Code Finish Code
ATEX Ex d D None N* 12-48V d.c. 048* None N 1 x M20 1B* None N Natural Black N†
ATEX Ex de E
IECEx Ex d DJ IIC Gas G 110V a.c. 110 Duty D* 2 x M20 2B Swivel bracket B Natural Red R
IECEx Ex de EJ IIIC Gas & Dust GD 120V a.c. 120* Tag T* 2 x M20 2BP EOL E* Yellow Y
UL UL 220V a.c. 220 Inc 1 x plug Earth cont. G† Grey G
UL(ordinary locations) UW 230V a.c. 230 1
1 x /2” NPT 1C* Alternative tone activation M** Blue B
Dual ATEX/UL AU
Dual IECEx/UL JU
240V a.c. 240* 2 x 1/2” NPT 2C* Volt free activation (remote) R** Special S*
CUTR Ex d DG * If Weatherproof or UL 254V a.c. 254† * Please specify. 2 x 1/2” NPT 2CP* Short flare S
CUTR Ex de EG (ordinary locations), select Inc 1 x plug Custom tones (not std 28) T‡ * Please specify.
CQST EX d Q N for Ex Atmosphere. * Complies with UL regulated † Short flare painted black.
Inmetro Ex d DM power supply requirements.
Inmetro Ex de EM
* Not available Ex e. * Specify value (Min 470Ω).
† Not available UL. Please note voltage limitation.
Weatherproof W
** These options cannot be selcted together
† Ex e only. ‡ Specify details
All specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice.
No liability is accepted for any consequence of use.
6DS159/C 12/14