STORAGE

PCS
Power Converter Stations

Modular Design What’s in it for You


• Can be adapted to each project’s needs.
Grid-Scale
• Ensures scalability & simplicity for any configuration & voltage level.
Solutions
• PCS's wide range of full power operation, enables integration with large
for a Changing
battery energy storage systems.
World
• Our PCS meets some of the most complex grid codes around the world.
• Our solution provides large-scale inertia services to improve power system By adopting PCS, you get:
reliability and stability, allowing systems to respond and rebalance supply
and demand during failures.
• A complete AC energy storage
Quick Dynamic Response platform
Quick dynamic response, providing advanced power management, • Advanced controls to support
including: microgrid applications and
• Load Leveling • Voltage Support interface with multiple generation
• Frequency Regulation • Islanding assets
• Capacity Firming • Black Start • Easy integration to any grid:
• Peak Shaving • Grid Inertia advanced power control functions
that ensure complete stability
Robust
• Higher efficiency to ensure the
• Designed for harsh environments.
best performance
• Filters and top-to-bottom cooling systems prevent dust contamination.
• Advanced power management
• Wide-ranging operating parameters maintain effectiveness in high
handles demanding environments
altitude mountainous regions.
• Internal electronics and components are coated to resist salty or for ramp rate, frequency response,
corrosive conditions. and energy shifting
• Sealed design elements of the standard IP54 enclosure protects from • Reliable system uptime and fast
rain and humidity. service response
• Supply chain security

Dust Protected >1000 m.a.s.l. IP54 / IP65 Salty air ready

eks Energy offers a integration of any energy storage technology to meet the most challenging requirements to
improve grid stability, match generation and consumption, optimize profits and increase the share of renewables.
Each project is evaluated using the most advanced calculation tools to optimize the battery systems required to
meet all technical requirements.

sales@eksenergy.com
eksenergy.com Shaping the energy of tomorrow
TECHNICAL SPECIFICATIONS
PCS - 1500V FULL POWER

PCS 1Ms PCS 2Ms PCS 3Ms


DC Intput 
DC input voltage range [VDC] 592 .. 1359 to 1550
DC input voltage range @ full power [VDC] (1) 592 .. 1359 to 1500
Max. DC voltage [VDC] 1550
Rated input current at VDC min @35ºC [A] 1600 3200 4800
Whistand current 80kA/50ms 2 x 80kA/50ms 3 x 80kA/50ms
120kA/4ms 2 x 120kA/4ms 3 x 120kA/4ms

AC Output 
Nominal AC voltage 400 - 950
AC/DC
Max. AC voltage range (2) 80% - 120%
Frequency [Hz] 50/60
Frequency operation range [Hz] 40 - 70
Rated AC current @ 50ºC @ 1500VDC up to [A] 852 1704 2556
Rated AC current @ 35ºC @ 1500 VDC up to [A] 951 1902 2853
Maximum output current [A] <1250 <2500 <3750
Rated AC POWER @ 35ºC @ 1500 VDC & 950 VAC [kVA] 1564 3128 4694
Rated AC POWER @ 50ºC @ 1500 VDC & 950 VAC [kVA] 1408 2816 4224
Total Harmonic Distortion (THD) <3%
Power factor Adjustable
Maximum Peak Efficiency (3) >98.5%
European Efficiency (3) >98.2 %
CEC Efficiency (3) >98.3%

Operation ambient temperature (4) -4ºF / 140ºF (-20ºC / 60ºC)


Operation ambient temp. (without de-rating) (5) -4ºF / 122ºF (-20ºC / 50ºC)
Storage and transport temperature -40ºF / 149ºF (-40ºC / 65ºC)
Enviromental Storage and transport humidity 5% ... 85%
Condicions Maximum relative humidity 100%
Max. altitude above sea level without derating 1000 masl
Max. altitude above sea level allowed 4000 masl
Protection degree (5) Type 3R, IP54

IEEE 1547
UL 1741 – Supplement SA (HI Rule No.14, 17 and CA Rule No.21)
Legal IEC 62109-1, IEC 62109-2, IEC62109-UL840
Standards IEC 61000-3-4, IEC 61000-3-11, IEC 61000-3-12, IEC 61000-6-4
IEC 60529
CE Marking
NEC Compliance
G99

Note: Specifications in the above table are design estimates only and are not guaranteed.
Contact eks for a project-specific estimate as final values depend on system design, location, and use case.
(1) At 100% Uac_nom, full power and cos ϕ = 1
(2) Other voltage configurations are possible under request
(3) Self-consumption is not considered in the efficiency measurement
(4) An extended operating temperature range is possible under request