Fyfe Asia Pte LTD: (ACI 318-05 Sect. 11.3.1)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FYFE ASIA PTE LTD

PROJECT: PAGE: OF
DATE:
LOCATION: DESIGNED BY:

SHEAR STRENGTH OF RECTANGULAR BEAM WITH TYFO COMPOSITE SYSTEMS:

®
Material: TYFO Code Used:

hf1 hf2

Asv
d
D df1 As df2

d' = Eff. Cover to Long. Steel


b

Design Data:
Required Shear Capacity, Vpr = kN

Geometry :
Web Width: b= mm Steel properties: layer(s) - mm
Depth: D= mm layer(s) - mm
Flange height - Side 1: hf1 = mm layer(s) - mm
Flange height - Side 2: hf2 = mm Concrete Cover = mm
Beam length: L= mm Effective depth,d = mm
Concrete grade: f'c = N/mm2 Eff. Cover, d'
Steel grade of links: fyv = N/mm2 Existing shear links: legged,
mmT dia. @ mm c/c

Existing Shear Capacity: (ACI 318-05)

Shear Capacity of Concrete


ØVc = Ø 1/6 sqrt(f'c) * (bw) * d = #N/A kN ( ACI 318-05 Sect. 11.3.1)

Shear Capacity of Stirrups


ØVs = Ø (Av) * (fyv) * (d) /s = #N/A kN ( ACI 318-05 Sect. 11.5.6)

Total existing shear capacity at the section

ØVt = ØVc + ØVs = kN Not Ok. Needs Strengthening!

Required Additional shear force, Vaddr = - kN

Strengthening for Shear with TYFO ® Systems


Select Member Exposure:
Select Wrapping Scheme:
Material Selected: TYFO®
Number of layers: nf = layer(s)
Spacing of Strip Sf = - mm
Width of Strip wf = - mm
Thickness per layer: tf = - mm
Composite depth, Side 1= d-hf1 = dfv1 = - mm
Composite depth, Side 2= d-hf2 = dfv2 = - mm

Vaddf = Additional Ult. Shear Capacity provided by TYFO ® System.

ØVaddf = Ø*Yf*Vf = - kN

ØVnew = ØVt + ØVaddf = - kN

Conclusion:
®
Provide: layer(s) of TYFO #N/A