Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

POWER MAGNETICS

Current Transformers for Electronic Watt-Hour Meters


DC tolerant
Toroidal Series
For use in electronic watt-hour meter applications
DC current inmunnity
Comply to Class 1.0 (IEC10636) standards
120/240V and 50/60 Hz applications
DC current capability up to 150 Apk
AC current up to 480 Apk for defined errors
Epoxy potted finished

ELECTRICAL SPECIFICATIONS
1
Irms max IDC max Ipk rms DCR (Ω)
FALCO PART NUMBER
L(H) @ 50Hz Tol. Turns Ratio (A) (A) (A) F(I) % φ (I) ° NOM. RB (Ω )
T75A11 4.6 ±20% 1:2500 20 20 125 <0.06 3.62 54.0 37.50
T81C15 3.7 ±15% 1:2500 40 40 215 <0.04 4.15 66.0 10.00
T87C23 3.0 ±15% 1:2500 60 60 245 <0.04 4.06 55.0 12.50
T10G20 2.1 ±17% 1:2500 100 100 314 <0.05 4.48 44.0 7.50
T12A04 1.7 ±17% 1:2500 120 158 480 <0.03 4.07 36.0 6.25

MECHANICAL SPECIFICATIONS
Front View Right View Schematic

D
A
BLUE
FP SP

C B
Primary* Secondary
E
FP

SP WHITE
* ONLY FOR REFERENCE

BLUE WHITE

A max. B max. C min. D max. E nom. F nom. G nom.


FALCO PART NUMBER
in / mm in / mm in / mm in / mm in / mm in / mm in / mm
T75A11 1.122 / 28.5 1.185 / 30.0 0.197 / 5.0 0.591 / 15.0 0.571 / 14.5 7.08 / 180 0.394 / 10.0
T81C15 1.102 / 28.0 1.122 / 28.5 0.216 / 5.5 0.630 / 16.0 0.561 / 14.25 7.08 / 180 0.394 / 10.0
T87C23 1.200 / 30.5 1.279 / 32.5 0.315 / 8.0 0.590 / 15.0 0.630 / 16.0 7.87 / 200 0.394 / 10.0
T10G20 1.358 / 34.5 1.358 / 34.5 0.413 / 10.5 0.571 / 14.5 0.669 / 17.0 7.87 / 200 0.394 / 10.0
T12A04 1.594 / 40.5 1.614 / 41.0 0.472 / 12.0 0.689 / 17.5 0.846 / 21.5 7.09 / 180 0.394 / 10.0

1. L & DCR tested at Ta= 25°C


2. Imax.= Maximum ac primary current with defined errors
3. IDCmax.= Maximum half wave rectified AC amplitude without saturation, F(Idc)<3%
4. Ipk= Maximum achievable AC primary current without saturation for F(I)<1%
5. φ (I)= Maximum phase error for Irms<Irms max. (IEC1036)
6. F(I)= Maximum amplitude error for Irms<Irms max. (IEC1036)
7. RB= Suggested burden resistor
8. Turns tolerance is ± 1 % typ
9. Operating Temperature Range: -40°C to +85°C

+1.305.662.7276 | www.falco.com | sales@falco.com CTWH_DC.PDF REV: A2 06/2005 1-2


POWER MAGNETICS

LINEARITY AMPLITUDE & PHASE ANGLE ERROR BIPOLAR

T75A11 T10G20

6.0 6.0

F (I) [%] & f [°] @ 25°C


F (I) [%] & f [°] @ 25°C

4.0 4.0

2.0 2.0

0.0 0.0

-2.0 -2.0
0.5

1.0

4.0

8.0

12.0

16.0

20.0

24.0

28.0

1
5
10
20
30
40
50
60
70
80
90
100
110
120
130
Irms (A) @ 60 Hz Irms(A) @ 60 Hz

T81C15 T12A04
6.0 6.0

5.0
F (I) [%] & f [°] @ 25°C
F (I) [%] & f [°] @25°C

4.0
4.0

2.0 3.0

2.0
0.0
1.0

-2.0 0.0
0.5

1.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

1
2
5
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Irms(A) @ 60 Hz Irms(A) @ 60 Hz

Phase Amplitude

T87C23
6.0
F (I) [%] & f [°] @ 25°C

4.0

2.0

0.0

-2.0
1

10

20

30

40

50

60

70

80

90

100

Irms(A) @ 60 Hz

+1.305.662.7276 | www.falco.com | sales@falco.com CTWH_DC.PDF REV: A2 06/2005 2-2