This release provides the following enhancements:
• Renamed the Manufacturing Operations Management (MOM) Adapter to Execution Core Closed
Loop Manufacturing (EX CR CLM) Adapter
• Added array support to the Open Platform Communications - Unified Architecture (OPC UA) Adapter
• Replaced the open-source SDK used by the OPC UA Adapter with a Unified Automation Assemblies
SDK
• Added Opcenter Connect MOM Setup Wizard to allow installation of all components at one time
Internationalization Enhancements
This release provides the following internationalization enhancements:
Known Issues
The following are known issues in this release:
• Oracle Installation: You must add the Oracle.ManagedDataAccess.dll file to this location when using
the Oracle Database Adapter:
C:\Program Files\Siemens\MIO\Opcenter Connect MOM\Channel Adapter Host
• The values for Retry Count or Time to Live fields will be too low if the Channel Adapter Host starts
processing messages before the Opcenter Connect MOM IIS services have started.
• The broker service may report that the server does not respond during start up and then return a
broker_init message. This is expected behavior while all of the services (Configuration, Router, and
Mapper) are starting.
• The Siemens Web Framework (SWF) user interface times out after 20 minutes by default. This can
be changed by updating the value in the Authentication Expiry (minutes) field on the Settings
configuration object. The application must complete the current timeout period before the setting
modification takes effect.
• The application displays the user interface layout incorrectly in Internet Explorer 11 when the scroll
bar appears. Resize the window to remove the scroll bar and update the display.
• You can create filters for adapters and message channels that have identical names and sequence
order. You should ensure that each filter name is unique.
• The interface in Oracle environments displays adapter instances in the incorrect order if the adapter
names use mixed casing.
• A grid selected in one instance remains in edit mode even if another instance is selected.
• When upgrading from 2.2 or earlier, you must open each custom workflow in Opcenter Connect
MOM Workflow Designer and then save it. You must then perform an IIS reset.
• New adapters, maps, and workflows are not exported until an IIS reset is performed.
Problem Resolutions
This section describes known problems recorded and resolved from the last release to this release. TAC
numbers are provided if available.
This table describes the issues resolved in Release 3.0.
TAC ID Description
9530266 MIO OPC UA Adapter does not respect Settings Maximum Log Level.
Resolution: OPC UA Adapter was updated to respect the Maximum Log Level specified in
Settings.
9587441 Installation fails if domain has period in full name.
Resolution: Installation functionality was updated to allow period in domain name.
9592438 Problem with MIORestClient if token is expired.
Resolution: Token functionality was updated.
9620126 Update User Guide replacing MIOAdapterHostService.exe.config with
CIOAdapterHostService.exe.config.
Resolution: Opcenter Connect MOM User Guide was updated with correct file name.
9622057 MIO Login issue with Domain account.
Resolution: Login functionality was updated.
9622499 MIO 2.3 installation failed due to mio_CreateTables.sql script.
Resolution: Updates were made to mio_CreateTables.sql script.
9624752 MIO - Subscription with old value for the monitored item
Resolution: OPC UA Adapter was updated to use the .NET based OPC UA SDK supplied by
Unified Automation.
User Documentation
The Opcenter Connect MOM documentation library is available in PDF format on the Siemens Global
Technical Access Center (GTAC) Support website. Visit the Support site for the most current documentation:
https://support.industrysoftware.automation.siemens.com/docs/opcenter/connect_mom/ .
Acrobat Reader is required. You can download Acrobat Reader for free from the Adobe Systems website
( http://www.adobe.com ).
The following files are available for Opcenter Connect MOM on the GTAC website.
Security Information
Siemens provides products and solutions with industrial security functions that support the secure operation of
plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement
– and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and
solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems, machines and
networks. Such systems, machines and components should only be connected to an enterprise network or
the internet if and to the extent such a connection is necessary and only when appropriate security measures
(e.g. firewalls and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please visit
https://www.siemens.com/industrialsecurity .
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens
strongly recommends that product updates are applied as soon as they are available and that the latest
product versions are used. Use of product versions that are no longer supported, and failure to apply the latest
updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under
https://www.siemens.com/industrialsecurity .
Change History
Revision Change
Release 3.0 Rev A Original publication.