Chapter 1. Preface …………………………………….. 3 page

Chapter 2. Specification …………………………………….. 4 page

Chapter 3. Installation …………………………………….. 8 page

Chapter 4. Calibration …………………………………….. 9 page

Chapter 5. Set-Up …………………………………….. 14 page

Chapter 6. F-Function …………………………………….. 17 page

Chapter 7. Interface …………………………………….. 33 page

Chapter 8. Error and Treatment …………………………………….. 42 page

Warrantee …………………………………….. 45 page

2
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 1. Preface
1. Introduction
This DN610 series Digital Weighing Indicator(DN610,DN630) model is din size powerful performance
for the industrial weighing system application.
RS-232 serial port can be expended up to 4pots, easy to connect with other devices and PC.
In case of DN630 model has 6pcs control relay output as a standard, easy to make weighing
automation system.
Please estimated this user manual and enjoy the performance of DN830 series digital weighing
Indicator.

2. Feature
2-1. Isolation from the external noise
2-2. Watch-dog function
2-3. Display resolution, up to 1/20,000
2-4. 2pcs Digital input terminal built in (Zero, Tare/Reset)
2-5. AC 85V~265V power supply.
2-6. Data back-up function
2-7. Full Automatic Calibration method
2-8. Simulating Calibration Method (without Span weight)
2-9. Option : RS-422

3. Caution
3-1. Weak for the drop damage or physical shock.
3-2. Do not install heavy electric noise place.
3-3. Do not install the heavy vibrating place.
3-4. Avoid from the humidity or rain damage.
3-5. Please Turn off the main power, when make connect with other devices.

4. Accessories
4-1. User Manual

5. Inquiries
If you have any kinds of inquiries for this model, please contact with your local agent or Head Office.
Head Office : DACELL co.,Ltd.
Website : http://www.dacell.com

Email : info@dacell.com

3
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 2. Specification
1. Analogue Input and A/D Conversion
Input Sensitivity 0.2㎶ / Digit
Load Cell Excitation DC 10V ( - 5V ~ + 5V )
Max. Signal Input Voltage Max.32mV
Temperature Coefficient [Zero] ±10PPM/℃ / [Span] ±10PPM/℃
Input Noise ±0.6㎶ P.P
Input Impedance Over 10㏁
A/D Conversion Method Sigma-Delta
A/D Resolution(Internal) 520,000 Count(19bit)
A/D Sampling Rate Max. 200times / Sec
Non-Linearity 0.01% FS
Display Resolution(External) 1/20,000

2. Digital Part

Display Parts Specification


7Segments, 6 Digit RED FND Display
Main Display
Size :14.1mm(H)×8.1mm(W)
Display Min. Division ×1, ×2, ×5, ×10, ×20, ×50
Max. display value +999,950
Under Zero value "-" (Minus display)
1. DN610 Model
- Steady, Zero, Tare,
Gross, Comm., Auto,
Print, Hold
Status lamp 2. DN630 Model
Green LED Display(3Ø)
- Steady, Zero, Tare,
Hold, Comm., Hi, Low,
End
Key Function keys Zero / F / Set / Enter (4pcs function keys)

3. General Part
Power Supply SMPS Free Voltage (AC85~265V)
Operating Temperature Range -5℃ ~ 40℃
Operating Humidity Range Under 85% Rh (non-condensing)
External Dimension 96mm(W)x96mm(H)x135mm(L)
Net Weight(kg) About 600g
Gross Weight(kg) About 800g

4. Option
Option No.1 RS-422
Option No.2 RS-232 (Standard Installation)
Option No.5 4~20mA (Analogue Output)
Option No.6 0~10V (Analogue Output)

4
Digital Weighing Indicator – DN610/630 Model
Din Size Series

5. Front Panel Display

5-1. Weight Display


- Current Weight value will be Display

- In case of DN630 model, display set value, whenever press key.

5-2. Status Lamp (From Left to Right) – DN610 model


- Steady : Lamp is “ON”, when the weight value is stable condition.
- Zero : Lamp is “ON”, when the weight value is Zero(including Tare weight)
- Tare : Lamp is “ON”, when the TARE function is activated
- Gross : Lamp is “ON”, when the displayed weight is Gross weight.
- RTxD. : Lamp is “ON”, when the Comm. is activated
- Auto : Automatic Print Function is Activated, Lamp is “ON”
- Print : Lamp is “ON”, when the print function is activated
- Hold : Lamp is “ON”, when the Hold function is activated

5-3. Status Lamp (From Left to Right) – DN630 model


- Steady : Lamp is “ON”, when the weight value is stable condition.
- Zero : Lamp is “ON”, when the weight value is Zero(including Tare weight)
- Tare : Lamp is “ON”, when the TARE function is activated
- Low : Lamp is “ON”, when the weight value reaches to “Low set value”.
- Hi : Lamp is “ON”, when the weight value reaches to “HI set value”.
- END : Lamp is “ON”, when the single weighing Batch is finished.
- Hold : Lamp is “ON”, when the Hold function is activated
- RTxD. : Lamp is “ON”, when the Comm. is activated

5
Digital Weighing Indicator – DN610/630 Model
Din Size Series

6. Key Pad (Basic Function)


Make current display value to Zero (within the Range)
- F08 function setting check

Zero SET UP Mode : Exit SET Up Mode.


Set / Reset “TARE” function.
- F09 function setting check

Function Move to “TEST Mode”. (press under SET-CAL mode)

DN610 model

SET UP Mode : (Press key with Power in)


Function Mode : Increase Function No.

DN630 model
Set
SET UP Mode : (Press key with Power in)
Function Mode : Increase Function No.
Low set value or HI set value check or change.

Save new set value


Enter

7. Hot key function

1. Increasing the set value


2. Exit for the “Set-Cal” condition
Zero

1. Move the display position


2. Move the “TEST mode” from “SET-CAL” mode
Function

1. Increasing the Function No. under Function setting mode


2. Enter to “Function mode” from “SET-CAL” mode
Set

1. Start Calibration mode, under “SET-CAL” mode


2. Save new set value and move next step
Enter

6
Digital Weighing Indicator – DN610/630 Model
Din Size Series

8. Rear Panel

8-1. Load Cell Terminal : +EXC ~ SHIELD


8-2. Earth : Right side of ACIN port
8-3. Power input : ACIN (2 port)
8-4. Digital input : C1 ~ X4
8-5. Relay output : C2 ~ R6 (Function 21 check – only for MI-730 model)

7
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 3. Installation

1. External Dimension

2. Panel Cutting Size

93mm

93mm 8
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 4. Calibration

1. SPAN Calibration
- Adjust weight balance between “Real weight” on the load cell(Weight Part) and “Displayed weight of
Indicator”. When you replace LOAD CELL or Indicator, you have to do Calibration process once again

- Applicable model DN610,DN830 series


Prepare at least 10% of Max. capacity of your weighing scale.

Step 1. Enter to the “SET-CAL” mode

SET-CAL
Pressing key during 7sec. then display will show .

SET-CAL
Or turn on the Power + with pressing  display.

Press key to start “Calibration Mode”.

Remarks : Go to next step with save key / Back to previous step key

Step 2. Digit/Division setting

- Whenever pressing key, digit value will be increased as 01-02-05-10-20-50.

- Whenever pressing key, digit value will be decreased as 50-20-10-05-02-01.

- Press key to save new set value and move to next step.

※ If you want to exit this mode, press key.

9
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Step 3. Max. Capacity setting

- Determine the Max. capacity of your scale.

Whenever pressing key, value will be increased, Whenever pressing key,


you can move to the left digit

※ Move to previous step, press key

Then, Press key to save new set value and move to next step.

Remarks
- The Max. capacity cannot be exceed Max. capacity of load cell.
- (Digit/Max. Capacity) value must be less than 1/20,000.

Step 4. Measure/Adjustment optimal Zero balance of Scale

- Press key to measure and adjustment Zero balance of Scale.

※ Before press key, please make clear on the scale part.

10
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Step 5. Input Prepared Test weight value and load on the Scale.

SPAn
- Then display will show and then, input prepared test weight value whenever

pressing key, value will be increased, Whenever pressing key, you can move to the
left digit

- Press key, value will be saved.

C_UP_
- Then display will show and then, load prepared test weight unit on the scale.

※ Move to previous step, press key.

- After a few seconds (to remove the vibration effect), press key.

Then, indicator will calculate Span value and move the next step.

Remarks : - Please prepare at least 10% of Max. Capacity.

Step 6. End Calibration and Auto Reset

- Calculated Span value will be displayed and automatically reset and move the normal weight
indicating mode.

11
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 5. Set-Up

1. Set-Up
Set-up means set the F-function and make DN610 series weighing controller will perform more
accuracy. (Considering external / internal environmental condition)

2. Enter to Set-up mode


- Applicable model : DN610 series
To make more accuracy performance of Digital Weighing Indicator, through this Function setting.

SET-CAL
Pressing key during 7sec. then display will show .

Press key to start “Function Mode”.

Step 2. Change Function No.

Whenever pressing key, function No. will be increased.


(Increase up to “01-53” and return to “01-01”)

Stop increase at the desired function No., press key.

If you press key, current set value will be saved.

If you press key one more, back to the “ST.CAL” mode.

Step 3. Change New set value for each Function No.

At the function No. display, input new set value with key and .

Press key to save new set value.

If you don’t press key, new set value will not be saved.

12
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Step 4. Exit Function Mode.

After save new set value with pressing key, then press key to Function mode.

To Exit Normal mode, press key.

13
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 6. F-Function List

1. F-Function List

General Function Setting


F00 Set-up & Calibration Selection
With and key
F01 Decimal Point setting 0 / 0.0 / 0.00 / 0.000
F02 Back up Mode Normal / Back up
F03 MOTION BAND Range setting 0, 1, 2, 3
F04 ZERO TRACKING Range setting 0, 1, 2, 3
F05 Auto Zero Range setting 00 ~ 99

F06 Digital Filter setting 00 ~ 49

F07 “Zero/Tare” key Operation mode select 0, 1

F08 “Zero” key operation range selection 0, 1, 2, 3, 4

F09 “Tare” key operation range selection 0, 1, 2, 3, 4

F10 “Hold” Mode selection 0, 1, 2

F11 External input selection 0, 1. 2, 3

F12 Key pad setting 0, 1, 2, 3, 4, 5, 6

F13 Code No. setting 0, 1, 2

F14 Hold Off time setting 00~99

Relay Output Mode setting (Only for DN630 model)


F21 Weighing Mode Selection 0, 1, 2, 3, 4, 5

F22 Weighing Finish Relay “ON” delay time 00~99


Weighing Finish Relay “ON” duration
F23 00~99
time
F24 Weighing Judge Relay “ON” delay time 00~99
Weighing Judge Relay “ON” duration
F25 00~99
time
F28 Weighing N.G Relay “ON” duration time 00~99

14
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Communication Mode setting


F30 Parity Bit selection Mode 0, 1, 2

F31 Serial Communication Speed selection 0~9

F32 DATA Transference Mode selection 0, 1, 2

F33 DATA Transference Method selection 0, 1, 2, 4

F34 Equipment No.(ID No.) Selection 1~99

F35 Data Format 0, 1

F36 BCC selection 0, 1

Serial Print Setting


F40 Weight Unit Selection (Printer) Setting range : 0~2
F41 Auto print Setting Setting range : 0~1
F42 Print format selection Setting range : 0~1
F43 Sub-Total Data delete Selection Setting range : 0~1
F44 Paper withdraw rate Selection Setting range : 0~9
F45 Print Line interval Selection Setting range : 0~9
F46 Auto Print Mode Setting range : 0~1
F47 Print Language Selection Setting range : 0~1
Print Delay time selection
F48 Setting range : 0.0 ~ 9.9
(DN610 Model)

Other setting
F80 Empty Range setting XXXXXX

F81 Zero display Range setting X. X X X X X

F89 Calibration Span value check X.XX X.XX. X

F90 Date Check and Change XX.XX.XX

F91 Time Check and Change XX.XX.XX

15
Digital Weighing Indicator – DN610/630 Model
Din Size Series

2. F-function Details

Set-up & Calibration Selection

F00
key : Move to Set-up mode key : Move to Calibration mode
Decimal Point Setting
0 No Decimal Point

1 1point under Zero


F01
Ï 2 2point Under Zero

3 3point Under Zero


Weight-Back up selection
Ï 0 Normal Mode
F02
1 Weight Back up Mode
Motion Band Range
This is set “Steady” acceptable range of weighing part.
If there is vibration on weighing part, you can set this function and
reduce the vibration effect on weighing process.
F03 1 0~3
0 : Weak vibration
+
50 : Strong Vibration
Zero Tracking Compensation Range setting

Due to external causes(Temperature, wind, and dust), there are small


weight difference, indicator will ignore the weight difference and
0 display Zero.
F04 1 + For this compensation function, indicator will estimate the weight
3 difference is over the set range during fixed time period.
If there is large weight difference over set range within fixed time
period, the “Zero” is breaking and will find new zero point.

Example) Max. Capacity : 100.00kg, Digit : 0.05kg, F04-03 setting


Zero Tracking Compensation Range : 0.5 ⅹ digit ⅹ F04 set value = 0.0025ⅹ3 = 0.075kg
Fixed time period : about 5msec. (Fixed time period will be effected on F06(digital filter) setting)

Weight
Zero breaks
Display Current weight
0.075kg
(1.5ⅹdigit)

Display Zero

time
about 5msec.

16
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Auto Zero Range setting

Within the “Auto Zero” range, weighing part is steady, indicator will
00 display current weight as “Zero”
F05 00 + If the weighing part is not “Steady”, indicator will display current
99 weight.
(Auto Zero Range : ± Set value + weight unit)

※ Using this function, you can get the Zero value without pressing “Zero” key, when there is
remained material in the hopper within Auto Zero Range.

Example) Max. Capacity : 10kg, Digit : 0.02kg, F005-30 setting,


Under this setting, Indicator will display “Zero” automatically, when the weight is within ± 0.30kg(Set
value + weight unit) and Steady.

Motion Band Range F03-01


+0.30kg
Steady
Range
Zero

-0.30kg
Motion Band Range F03-01

Digital Filter setting

A : Frequency Filter setting value


If “B” set value is fixed, “A”
01 (0~3)
set value is large, the
F06 5 ~ (0 : about 200Hz/sec, 1 : about
indicator will response more
49 500Hz/sec)
sensitive.
B : Buffer Filter setting value (1~9)

Zero /Tare key Operation mode selection

Ï 0 Activate when “Steady” condition, only


F07
1 Always activated

Zero key Operation Range selection


0 Activated within 2% of Max. Capacity
1 Activated within 5% of Max. Capacity

F08 2 Activated within 10% of Max. Capacity

Ï 3 Activated within 20% of Max. Capacity

4 Activated within 100% of Max. Capacity

17
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Tare key Operation Range selection


0 Activated within 10% of Max. Capacity

1 Activated within 20% of Max. Capacity


F09
2 Activated within 50% of Max. Capacity
Ï 3 Activated within 100% of Max. Capacity
“Hold” Mode selection
Ï 0 Peak Hold : Measure Max. weight value and hold on display.

F10 1 Sample Hold : Hold current weight until “Hold Reset”.

2 Average Hold : Make Average during 5sec and “Hold Display”.

External Input Selection – DN610 model


Set Value In 1. In 2. In. 3 In 4.
0 Zero Tare Tare Reset Print

Ï 1 Zero Tare/Reset Hold Hold Reset

F11 2 Zero Tare/Reset Sub Total Print


3 Zero Hold Hold Reset Print
4 Zero Sub Total Grand Total Print

External Input Selection – DN630 model


Set Value In 1. In 2. In. 3 In 4.
0 RUN Stop Tare Tare Reset

1 RUN/STOP Tare/Reset Zero Print

F11 2 Zero Tare/Reset Judge Print


Ï 3 Zero Tare/Reset Hold Hold Reset
4 Zero Tare Tare Reset Print
5 Zero Sub Total Grand Total Print
Key Pad Setting – DN610 Mode

Set Value

Ï 0 ZERO TARE/RESET SET PRINT

1 ZERO HOLD SET Hold Reset

F12 2 ZERO Sub Total SET PRINT

3 ZERO Hold/Reset SET PRINT


4 ZERO Tare SET Tare Reset
5 ZERO Tare/Reset SET Hold/Reset
6 ZERO Tare Tare Reset Gross/Net

18
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Key Pad Setting – DN630 Model

Set Value

Ï 0 Zero Tare/Reset SET PRINT

1 Zero Hold SET Hold Reset

2 Zero Run SET Stop


F12
3 Zero Sub Total SET PRINT
4 Zero Hold/Reset SET PRINT
5 Zero Run/Stop SET PRINT et
6 Zero Tare SET Tare Reset
7 Zero Tare/Reset SET Hold/Reset

Code No. Setting

Ï 0 Fixed Code

F13 1 Increase one by one, whenever finish the batch

2 Decrease one by one, whenever finish the batch

Hold Off time setting (only for F10-1/2 setting)

F14 00 00~99 00sec ~ 99set : Hold function will be off

19
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Relay Output Mode Setting – only for DN630 model

Weighing Mode selection

Ï 1 Normal Batch – Limit

2 Programming Batch – Packer

F21 3 Comparison 1. (Checker 1)

4 Comparison 2. (Checker 2)

5 Comparison 3.(Checker 3)

Weighing Mode Selection

Relay Output Out 1 Out 2 Out 3 Out 4 Out 5 Out 6


Under Over
1 Limit SP1 SP2 Finish Empty
N.G N.G
Under Over
2 Packer SP1 SP2 Finish Empty
N.G N.G
Checker LOW HIGH OK Under Over
3 Empty
1 (Empty~SP1) (SP2<~) (SP1<OK<SP2) N.G N.G

Checker LOW HIGH OK Under Over


4 Empty
2 (Empty~SP1) (SP2<~) (SP1<OK<SP2) N.G N.G

Checker LOW HIGH OK Under Over


5 Empty
3 (Empty~SP1) (SP2<~) (SP1<OK<SP2) N.G N.G

Checker Mode 1. : Will start checking the weight, after “Judge” input.
Checker Mode 2. : Will start checking the weight, after “Hold” input.
Checker Mode 3. : Check the weight and relay output, after “Steady Lamp”.

20
Digital Weighing Indicator – DN610/630 Model
Din Size Series

◆ Weighing Mode 1. Limit Mode 1. (F21-01 setting) - Relay “ON” when weight reaches to set
value
Weight

SP2 FINISHED WEIGHT

SP1

Near Zero

TARE(IN)
Output 1
SP1
Output 2
SP2
t1 t2 Output 3
FINISH
t5 Output 4
LOW NG
t5 Output 5
HI NG
Output 6
EMPTY

1. Set value setting : SP1(BULK), SP2(FINAL)


2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
※ Finish Relay will be “OFF”, after “t2” time set or weight is under “Empty Range”.
4. Output Relay
Relay Contents Relay Contents
Current weight e LOW(ON) After “t1” time,
SP1 LOW NG
Current weight < LOW(OFF) “On” during “t5” time
Current weight e HIGH(ON) After “t1” time,
SP2 HIGH NG
Current weight < HIGH(OFF) “On” during “t5” time
After “t1” time,
FINISH Near Zero Within “EMPTY” range (ON)
“On” during “t2” time

21
Digital Weighing Indicator – DN610/630 Model
Din Size Series

◆ Weighing Mode 2. Packer Mode (F21-02 setting)


Weight

SP2 FINISHED WEIGHT

SP1

Near Zero

TARE(IN)

RUN(IN)

SP1 Output 1
SP2 Output 2

FINISH t1 t2 Output 3

LOW NG t5 Output 4
HIGH NG t5 Output 5

EMPTY Output 6

1. Set value setting : SP1(BULK), SP2(FINAL)


2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
4. Relay Output
Relay Contents Relay Contents
RUN input : ON RUN input : ON
SP1 LOW NG
Current weight=SP1(OFF) Current weight=SP4(OFF)
RUN input : ON After “t1” time,
SP2 HIGH NG
Current weight=SP2(OFF) “On” during “t2” time
RUN input : ON
FINISH Near Zero Within “EMPTY” range (ON)
Current weight=SP3(OFF)

22
Digital Weighing Indicator – DN610/630 Model
Din Size Series

◆ Weighing Mode 3. Comparison Mode (F21-03 setting) - Checker Mode 1.


Weight HIGH

SP2
OK

SP1 LOW

EMPTY

JUDGE Input
t3 t4
Output 1
SP1
t3 t4 Output 2
SP2
t3 t4Output 3
OK
t5
Output 4
LOW N.G
t5 Output 5

Output 6
HI N.G
Empty

1. Set value setting


LOW (Low Limit), HIGH(Over Limit), OK will be within LOW and HIGH.
2. Each relay will be “ON” within its own acceptable range after “t3”time, during “t4” time.
3. Weight Judgment will be started after “Judgment” input.
4. Relay Output

Relay Contents Relay Contents

SP1 Less than LOW set value, “ON” LOW N.G Less than LOW set value, “ON”

SP2 More than HIGH set value, “ON” HI N.G More than HIGH set value, “ON”

LOW <Steady Weight<HIGH, NEAR


OK Within “EMPTY” range (ON)
“ON” ZERO

23
Digital Weighing Indicator – DN610/630 Model
Din Size Series

◆ Weighing Mode 4. Comparison Mode (F21-04 setting) - Checker Mode 2.


Weight HI

SP2
OK

SP1 LOW

EMPTY

HOLD Input
t3 t4
Output 1
SP1
t3 t4 Output 2
SP2
t3 t4Output 3
OK
t5
Output 4
LOW N.G
t5 Output 5

Output 6
HI N.G
Empty

1. Set value setting


LOW (Low Limit), HIGH(Over Limit), OK will be within LOW and HIGH.
2. Each relay will be “ON” within its own acceptable range after “t3”time, during “t4” time.
3. Weight Judgment will be started after “HOLD” input.
After Finishing Judgment, press “HOD RESET” and start new weight judgment.
4. Relay Output

Relay Contents Relay Contents

SP1 Less than LOW set value, “ON” LOW N.G Less than LOW set value, “ON”

SP2 More than HIGH set value, “ON” HI N.G More than HIGH set value, “ON”

LOW <Steady Weight<HIGH, NEAR


OK Within “EMPTY” range (ON)
“ON” ZERO

24
Digital Weighing Indicator – DN610/630 Model
Din Size Series

◆ Weighing Mode 5. Comparison Mode (F21-05 setting) - Checker Mode 3.


Weight HI

SP2
OK

SP1 LOW

EMPTY

t4
Output 1
SP1
t4
Output 2
SP2
t4
Output 3
OK
t5
Output 4
LOW N.G
t5 Output 5
HI N.G
Empty Output 6

1. Set value setting


LOW (Low Limit), HIGH(Over Limit), OK will be within LOW and HIGH.
2. Each relay will be “ON” within its own acceptable range after “Steady”, during “t4” time.
3. Relay Output

Relay Contents Relay Contents

SP1 Less than LOW set value, “ON” LOW N.G Less than LOW set value, “ON”

SP2 More than HIGH set value, “ON” HI N.G More than HIGH set value, “ON”

LOW <Steady Weight<HIGH, NEAR


OK Within “EMPTY” range (ON)
“ON” ZERO

25
Digital Weighing Indicator – DN610/630 Model
Din Size Series

“FINISH Relay” delay time(t1) setting (Under F21- 01, 02 setting)


After current weight is reached to FINAL, you can set some delay
time of “FINISH relay ON time.
Steady point
00

F22 10 +
FINISH Relay
Com-Out5
99
“00” setting : At Steady point, FINISH relay output
“20” setting : After 2.0sec from Steady point, FINISH relay output
“99” setting : After 9.9sec from Steady point, FINISH relay output
FINISH Relay “ON” time(t2) setting (Under F21-01, 02 setting)
You can set duration time for FINISH relay.

01 Steady point

F23 10 +
t2
FINISH Relay
99 Com-Out5
“01” setting : FINISH relay will be “ON during 0.1sec.
“20” setting : FINISH relay will be “ON” during 2.0sec.
“STEADY” Judging delay time(t3) setting (Only for F21-03, 04 Check mode)
After current weight is reached to each set point, you can set some
delay time of “STEADY”.
Steady point
01

F24 10 + t3

Com-Out5
99
“00” setting : At Steady point, FINISH relay output
“20” setting : During 2.0sec, hold “Steady” relay
“99” setting : During 9.9sec, hold “Steady” relay
“STEADY” Judging “ON” time(t4) setting (Only for F21-03, 04 Check mode)
After current weight is reached to each set point, you can set some
delay time of “STEADY”.
Steady point
00

F25 10 +
t4

99 Com-Out5

“00” setting : During the weight reaches to “Empty Range”..


“20” setting : During 2.0sec, Relay will be on.
“99” setting : During 9.9sec, Relay will be on.

26
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Weighing N.G Relay “ON” Duration time


01 01 : N.G relay will be “ON”, during 0.1sec
F34 01 +
99 99 : N.G relay will be “ON”, during 9.9sec

Communication Mode setting


Parity Bit selection Mode
Ï 0 No Parity

F30 1 Odd Parity

2 Even Parity

Serial Communication Speed selection


0 115,200bps
1 76,800bps
2 57,600bps
3 38,400bps
F31 4 28,800bps
5 19,200bps
6 14,400bps
Ï 7 9,600bps
8 4,800bps
9 2,400bps
DATA Transference Mode selection (Under F32-00, F35-00 setting, only)
Ï 0 Stream Mode : Weighing Data will be transferred continuously.

F32 1 Finish Mode : When Finish Relay output, only 1 time transferred.

2 Manual Mode : When “Print” key input, 1 time transferred.

DATA Transference Method selection


Ï 0 Simplex Mode / Stream Mode

1 Duplex Mode / Command Mode


F33
2 LCD Mode

4 External Display Mode

Equipment No. setting


01 Equipment No. setting with No. key.
F34 01 +
99 (01 ~99 settable)
DATA Transference Format selection
Ï 0 Standard Format 1.
F35
1 Standard Format 2

BCC Selection Mode


Ï 0 BCC not use
F36
1 BCC use

27
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Serial Printer Setting

Weight Unit selection (Printer)


Ï 0 kg

F40 1 g

2 t

AUTO Print Selection – DN610 Model, Only

When Weight is steady over than Empty Range, Automatically print.


Ï 0
- Check Empty Range
F41
Over than Empty Range, Steady Lamp is “ON”, Automatically Print.
1
- Will not check Empty Range

Print Format selection

Continuous Print
Ï 0
Serial No. and Weight will be printed continuously.
F42
Single Print
1
Date, Time, S/N, ID No. Weighing Data will be print

SUB/GRAND Total Data Delete selection

Manual Delete Mode


Ï 0 SUN Total Delete : “Clear” key + “SUB” key
GRAND Total Delete : “Clear” key + “GRAND” key
F43
Automatic Delete Mode
1
After SUB/GRAND Total Print, Automatically Deleted.

Paper Withdraw Rate setting (After Finish Printing process)

1
F44 3 + Whenever set value increased, 1line will be added.
9

Printer Line Interval Selection (Only for Continuous Printer format)

1
F45 3 + Whenever set value increased, 1line will be added.
9

Auto Print Selection – DN630 Model, Only

Ï 0 Manual : Print output, when “Print Input”.


F46
1 Auto : Print output, when Finish Relay output.

28
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Printing Language Selection

Ï 0 KOREAN
F47
1 ENGLISH

Print Delay time Setting – DN610 Model, Only

00 00 : No Delay time
F48 00 +
99 99 : 9.9sec later, print output

Other Setting

EMPTY Range setting


You can set “EMPTY” Range.
Within set range, indicator will not display current weight and just
display “Zero”.
X.X.X.X.X.X.
F80
(0.0.0.0.1.0) “0.000” setting : When Net Zero, “Zero” status lamp and Near Zero
relay will be output.
“0.190” setting : Within 190, “Zero” Status lamp and Near Zero relay
will be output.

Zero Display Range

Zero display range setting


X.X.X.X.X.X. If you set 50 as a set value, under 50 weight value will
F81
(0.0.0.0.1.0) be displayed as Zero.
Display will show “0” to “51” directly.

Span Calibration Value

Check the Span Calibration value.


X.X.X.X.X.X.
F89
(0.0.0.0.1.0)
Or set the new value.( Authorized personnel only)

DATE Check / Change

F90 Check Current DATE data or you can Change to new date

TIME Check / Change

F91 Check Current TIME data or you can Change to new TIME

29
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 7. Interface
1. Rs-232C (Standard Installed)
RS-232C Serial Interface is sensitive/weak for electric Noise.
So, please isolate with AC power cable and use shield cable to reduce the electric noise effect.

1-1. Connection

RXD2 ---------------------- Pin3 TXD

TXD2 ---------------------- Pin2 RXD

GND2---------------------- Pin5

DN610 Series Indicator GND PC(D-Sub 9Pin)

TXD2 --------------------------- RXD

GND2 -------------------------- GND

DN610 Series Indicator Remote Display

1-2. Signal Format


①. Type : EIA-RS-232C
②. Communication Method : Half-Duplex, Full Duplex, Asynchronous
③. Serial Baud Rate : Selectable
④. Data Bit : 8(No Parity mode, only)Bit.
⑤. Stop Bit : 1
⑥. Parity Bit : Non, Even, Odd (Selectable)
⑦ Code : ASCII

1-3. Data Protocol (Data Format 1. – Total 18byte)

, , K g CR LF

Header1 Header2 Data(8) unit


30
Digital Weighing Indicator – DN610/630 Model
Din Size Series

▶ Header 1
- OL : OVER LOAD or UNDER LOAD
- ST : Weight Stable
- US : Weight Unstable

▶ Header 2
- NT : Net Weight (Without TARE Weight)
- GS : Gross Weight (With TARE Weight)

▶ DATA(8) Symbol(1) , Decimal Point(1) , Weight (6) = total 8BYTE, like +000.190
- 2B(H): "+"PLUS
- 2D(H): "-"MINUS
- 2O(H): " "SPACE
- 2E(H): "."Decimal point

▶ UNIT
- Kg , g

1-4. Data Protocol (Format 2 – Total 22byte)

, , , K g CR LF

Lamp DATA(8) Blank


Header1 Header2 ID No. unit

▶ Header 1
- OL : OVER LOAD or UNDER LOAD
- ST : Weight Stable
- US : Weight Unstable

▶ Header 2
- NT : Net Weight (Without TARE Weight)
- GS : Gross Weight (With TARE Weight)

▶ ID No. : Function 34 setting (Default No is 1)

▶ Lamp : Status Lamp Condition


bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
1 Stable 1 Hold Print Gross TARE Zero

▶ DATA(8) Symbol(1) , Decimal Point(1) , Weight (6) = total 8BYTE, like +000.190
- 2B(H): "+"PLUS
- 2D(H): "-"MINUS
- 2O(H): " "SPACE
- 2E(H): "."Decimal point

▶ UNIT
- Kg , g

31
Digital Weighing Indicator – DN610/630 Model
Din Size Series

2. Rs-422 Serial Interface (Option)


RS-422/485 serial interface is more stable for electric noise effect compare with other communication
method, using electric current difference.
But, install isolated place from Power cable or other electric cables and wires, and please use shielded
cable for better performance.
Recommendable communication distance is about 1.2km.

2-1. Connection

Pin6 RXD+ ------------------- TXD+

Pin7 RXD- -------------------- TXD-

Pin8 TXD+ ------------------- RXD+

DN610 Series Indicator PC(D-Sub 9Pin)


Pin9 RXD- -------------------- RXD-

2-2. Signal Format (As Same as “Rs-232C Serial interface)


①. Type : EIA-RS-232C
②. Communication Method : Half-Duplex, Full Duplex, Asynchronous
③. Serial Baud Rate : Selectable
④. Data Bit : 8(No Parity mode, only)Bit.
⑤. Stop Bit : 1
⑥. Parity Bit : Non, Even, Odd (Selectable)
⑦ Code : ASCII

2-3. Data Protocol (Data Format 1. – Total 18byte) - As same as “Rs-232c Serial Interface

, , K g CR LF

Header1 Header2 Data(8) unit

2-4. Data Protocol (Format 2 – Total 22byte) - As same as “Rs-232c Serial Interface

, , , K g CR LF

Lamp DATA(8) Blank


Header1 Header2 ID No. unit

32
Digital Weighing Indicator – DN610/630 Model
Din Size Series

▶ COMMAND MODE

1. READ COMMAND [Start(STX ), End(ETX ), Succeed(ACK ), Failed(NAK )]

RxD & TxD Transfer & Response display Command


PCIndicator (ASCII)
Format (HEX)
Date Data
Response (ASCII)
from
(HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Time Data
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Serial No.
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Code No.
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Part No.
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
TARE weight
Response (ASCII) value
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Current
Response (ASCII) Weight value
from
Indicator
(HEX)

33
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Remark STX(1) ID(2) Command(4) Status1(2) Status2(2) Symbol(1)


Weight (Include decimal point)(7) Unit(2) ACK(1) ETX(1)
= Total 23 BYTE

PCIndicator (ASCII)
Format (HEX)

Response (ASCII)
from (HEX)
Sub-Total
Indicator Data

Remark STX(1) ID(2) Command(4) P/N(2) Code(6) Sub-Total times(6)


Sub-Total Weight(8) ACK(1) ETX(1) = Total 31 BYTE

PCIndicator (ASCII)
Format (HEX)

Response (ASCII)
from
Grand-Total
Indicator
Data
(HEX )

Remark STX(1) ID(2) Command(4) P/N(2) Code(6) Grand-Total times(6)


Grand-Total Weight(10) ACK(1) ETX(1) = Total 33 BYTE

PCIndicator (ASCII)
Format (HEX)
Weighing
Response (ASCII) Condition
from (HEX)
Indicator

PCIndicato (ASCII)
r Format (HEX)

Response
from
Indicator
Memorized
Data

(HEX)

Remark STX(1) ID(2) Command(4) Date(6) Time(6) P/N(2) Code(6)


Sub-Total times(6) Tare(6) Current Weight(6)
Grand-Total Weight(6) ACK(1) ETX(1) = Total 53 BYTE

PCIndicator (ASCII)
Format (HEX) Low (SP1)
Response (ASCII) DATA
from

34
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Indicator (HEX)

PCIndicator (ASCII)
Format (HEX)
High (SP2)
Response (ASCII) DATA
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Free Fall
Response (ASCII) DATA
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX )
Under
Response (ASCII) Weight DATA
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Over Weight
Response (ASCII) DATA
from (HEX)
Indicator

2. WRITE COMMAND [Start(STX ), End(ETX ), Succeed(ACK ), Failed(NAK )]

RxD & Transfer & Response display Command

TxD
PCIndicator (ASCII)
Format (HEX)
TARE input
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
TARE RESET
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
ZERO input
Response (ASCII)
from (HEX)
Indicator

35
Digital Weighing Indicator – DN610/630 Model
Din Size Series

PCIndicator (ASCII)
Format (HEX)
Print input
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format ( HEX)
Sub-Total Print
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Grand-Total
Response (ASCII) Print
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) Date(6) ETX(1) Date setting


Response (ASCII)
from (HEX)
Indicator
PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) Time(6) ETX(1) Time setting


Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) S/N(6) ETX(1) Serial No.


Change
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) P/N(2) ETX(1) Part No.


Change
Response (ASCII)
from (HEX)
Indicator

36
Digital Weighing Indicator – DN610/630 Model
Din Size Series

PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) Code(6) ETX(1) Code No.


Change
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Hold input
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Hold RESET
Response (ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Sub-Total Data
Response (ASCII) Clear
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Grand-Total
Response (ASCII) Data Clear
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX) Start(Run) Input
Response (ASCII)
(F21 – 02)
from (PACK MODE)
(HEX)
Indicator

PCIndicator (ASCII)
Format (HEX) STOP Input
Response (ASCII)
(F21 – 02)
from (PACK MODE)
(HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Low (SP1) set
Remark STX(1) ID(2) Command(4) Low<SP1>(6) ETX(1) value change
Response (ASCII)

37
Digital Weighing Indicator – DN610/630 Model
Din Size Series

from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Remark STX(1) ID(2) Command(4) High<SP2>(6) ETX(1) High (SP2) set
Response value change
(ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)

Remark STX(1) ID(2) Command(4) Free Fall(6) ETX(1) Free Fall set
Response value change
(ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Remark STX(1) ID(2) Command(4) Under(4) ETX(1) Under Limit set
Response value change
(ASCII)
from (HEX)
Indicator

PCIndicator (ASCII)
Format (HEX)
Remark STX(1) ID(2) Command(4) Over(4) ETX(1) Over Limit set
Response (ASCII)
value change
from (HEX)
Indicator

38
Digital Weighing Indicator – DN610/630 Model
Din Size Series

Chapter 8. Error and Treatment


1. TEST Mode
- Using several Test modes, you can test indicator performance.

5-1. Enter to TEST mode

Press key during 7sec.

Display will show “TEST”, then select each test mode, with pressing key.

Press key for the certain TEST mode, and enter to that TEST mode.

After checking or test each mode, press key to Exit.

Under TEST display, press key, then enter to Calibration mode.

TEST Modes Guide

TEST 1 - Check Zero Value with Digital Signal.

TEST 2 - Key test Mode or Analogue Option Card Test

- Calibration Mode
TEST 3
☞ Back to the TEST mode, press key.

TEST 4
- Display Test Mode. key to back to the other TEST Mode.

TEST 5
- Relay Test Mode. key to back to the other TEST Mode.

TEST 6
- Input Test Mode. key to back to the other TEST Mode.

TEST 7
- Analogue Value amplification Test. key to back to the other TEST Mode.

※If you installed Analogue Option card, you can test Analogue output test with “TEST 2”
mode. (Please check detailed information)

39
Digital Weighing Indicator – DN610/630 Model
Din Size Series

2. Error and Treatment


2-1. Load Cell Installation
Error Cause Treatment Remark

1).Input Resistance
1). Load cell broken of “EX+” and “EX-
1). Measure
2). Load cell “ is about
input/output resistance
isolation 350& ~450& .
of Load cell.
resistance error
3). Weighing part 2). Output
Weight Value is 2). Measure Load cell
touches other Resistance of “EX-
unstable isolation resistance
devices or some “ and “EX+” is
weight is on the about 350& .
3) Check attach point
weighing part
with other devices.
4). Summing Board 3). Isolate
Error Resistance is more
than 100&

Weight Value is 1). Check Load cell


1). Load cell Error
increased regular connection
2). Load cell
rate, but not return 2). Measure Load cell
connection Error
to “Zero” Resistance

Weight Value is Load cell Output wire


increased to under (SIG+, SIG-) is Make wire correction
Zero switched

Load cell broken or Load cell Check


Indicator connection Load cell connection
Error Check

“UN PASS” display

Power was “ON”


Remove weight on the
when some weight is
Load cell
on the load cell?

“OL” or “UL” display 1). Load cell broken 1). Load cell Check
or Indicator 2). Load cell connection
connection Error Check
2). Loading over than 3). Remove over
Max. Capacity loaded weight

40
Digital Weighing Indicator – DN610/630 Model
Din Size Series

2-2. Calibration Process


Error Cause Treatment

When Max.capacity/digit Re-input the Max. Capacity, less than 20.00


Err 01
value is over 20.00 (Max. Capacity / Digit)

Standard weight value is Re-input Standard weight value with Number


Err 04
over than Max. Capacity keys, under Max. Capacity

Standard weight value is


Re-input Standard weight value with Number
Err 05 less than 10% of Max.
keys, more than 10% of Max. Capacity
Capacity

1. Amp. Gain is too big Check standard weight’s weight with set value.
2. Sig+ and Sig- wire If there is difference between set value and real
Err 06
connection error weight, please re-input the value
3. Test weight is not loaded (set value is too small)
1. Amp. Gain is too small Check standard weight’s weight with set value.
2. Sig+ and Sig- wire If there is difference between set value and real
Err 07
connection error weight, please re-input the value
3. Test weight is not loaded (set value is too big)

Under “F-function” model,


Err 08 Check the correct value and re-input
set value is “N.A”

When Y.Y has the value


between 3.9 ~ 9.9 at
Y.YXXXX as Span value, Change the Max.capacity/digit value
Err 09
If standard weight value is (Ex: digit 01  05)
less than 10% of Max.
Capacity

When there is continuous


- Find vibration cause and remove
vibration on the weighing
- Load cell check
Err A part,, indicator can not
- Load cell cable and connecting condition
process calibration any
check
more.

41