Parker Filtration Group - GSF (July 2016)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

The Parker GS&F

Platform Umbrella
• Parker is #1 in GS&F globally
• Many valued brands
• A product for just about every
market and application
• The platform operates as
collective group &
• Whether, we can render our
SERVICES to your esteemed
organization?
Gas Separation & Compressor
Food & Filtration Room
Beverage (Industrial & Lab Gas Generators,
Filters, Dryers & Chillers)

Chemical, Oil,
Power Gen
Electronics
& Gas & Manufacturing
Landfill Gas Paint

NBC Light Ethanol


Alternative
Personal Industry &
Protection Fuels Bio-Diesel
Compressed Air & Gas Products & Systems
Filtration Technology
• Global Brands
• Airtek
• Balston
• domnick hunter
• Hiross
• Zander
• Compressed Air & Gas
Filters
• Coalescing
• Particulate
• Water Separators
• Instrumentation Filters
• Sample Filters
• Steam & Sterile Air Filters
• Vacuum Filters
• Inlet
• Exhaust
• ParFit Elements
Compressed Air & Gas Products & Systems
Drying Technology
• Global Brands of Air Dryer
• Airtek
• Balston
• domnick hunter
• Hiross
• Zander
• Refrigerated Dryer
• Desiccant Dryer
• Heatless
• Heat Regenerative
• Blower Regeneration
• Vacuum Regeneration
• Membrane Dryer
• Dryer Types
• Modular / Twin Tower
• Compressed Air &
Technical Gas
• High Pressure
Drying Technologies Water Vapour Removal

Refrigeration Dryers
Dewpoint’s of Adsorption Dryers Hybrid Dryers
+3°C, +7°C or +10°C & Dewpoint’s of Dewpoint’s of
Operating pressure up -20°C, -40°C or -70°C -20°C, -40°C or -70°C
to 50 Bar [G]

Pressure Swing Vac Assisted PSA Thermal Swing Blower Vacuum


Adsorption (PSA) (VPSA) Adsorption (TSA) Regeneration Regeneration

Twin Tower Modular


Construction up to 400 Bar [G] Operating Pr. Construction up to 13 Bar [G] Operating Pr.
Desiccant Compressed Air Dryers

● Heatless ● Externally Heated ● Blower Purge ● Low Dewpoint Heatless ● High Pressure
● Oil & Gas ● Modular Heatless ● High Pressure Modular

7
Membrane Compressed Air Dryers

● Membrane Modules ● Membrane Dryers ● Cabinet Dryers

8
Air Drying solutions: Refrigeration Dryers

Starlette Plus PoleStar Smart PoleStar Smart HP


11 Models 20 Models 12 Models
Flow rates: 0,2-6 m3/min Flow rates: 4-180 m3/min Flow rates: 3-63 m3/min

Quasar
5 Models
Large Capacity Dryer
Flow rates: 130-350 m3/min 10 Models
Flow rates: 61-450 m3/min
Condensate Management

● Oil/water separators ● Condensate Drain ● Visual Sump Drain ● ZERO LOSS


Electronic Drain Valve ● Adjustable Timed Drain ● Timed Drain Valve ● Float Operated
Drain Trap ● High Pressure Drain Kits
OIL-X EVOLUTION
Technical Die-cast Water Separators
Specifications and Filters
• Min 1 bar g – Max 16 bar g with Float Drain
Pressure Range • Max 20 bar g with manual / alternative drain

• Min 2°C – Max 80°C with Float Drain


Temperature Range
• Max 100°C with manual drain
Flow Range • 36 m3/hr – 3600 m3/hr
Water Separators • 21cfm – 2199 cfm
Flow Range • 22 m3/hr – 3600 m3/hr
Filters • 13 cfm – 2199 cfm

• ¼” – 4” BSPP
Port Sizes
• ¼” – 4” NPT

11
OIL-X EVOLUTION
Technical Fabricated Water
Specifications Separators and Filters

Pressure Range • Min 1 bar g – Max 16 bar g with Float Drain

Temperature Range • Min 2°C – Max 66°C with Float Drain

Flow Range • 1260 m3/hr – 25290 m3/hr


Water Separators • 742 cfm – 14885 cfm
Flow Range • 1548 m3/hr – 28080 m3/hr
Filters • 911 cfm – 16528 cfm

• DN40 – DN300 Water Separators


Port Sizes
• DN80 – DN300 Filters

12
OIL-X EVOLUTION
Technical OVR Oil Vapour Removal
Specifications Filters

Pressure Range • Min 1 bar g – Max 16 bar g

Temperature Range • Min 2°C – Max 50°C

Flow Range • 288m3/hr – 2232 m3/hr Single Units


OVR • 170 cfm – 1314 cfm Single Units
Flow Range • > 2232 m3/hr Multi-banked
OVR • > 1314 cfm Multi-banked

• 1” – 3” BSPP
Port Sizes
• 1” – 3” NPT

13
OIL-X EVOLUTION
Filtration Grades

Initial
Max Remaining Initial Dry Change Precede
Filtration Filter Particle Filtration Saturated
Oil Content at Differential Element with
Grade Type removal Efficiency Differential
21°C (70°F) Pressure Every Grade
Pressure

Water 20 - 100
WS N/A N/A >92% N/A N/A N/A
Separator mbar

WS (for
Down to 1 0.6 mg/m3 <70 mbar <140 mbar
AO Coalescing 99.925% 12 months bulk
micron 0.5 ppm(w) (1psi) (2psi)
liquid)
Down to 0.01 0.01 mg/m3 <140 mbar <200 mbar
AA Coalescing 99.9999% 12 months AO
micron 0.01 ppm(w (2psi) (3psi)

Down to 1 <70 mbar


AR Dry Particulate N/A 99.925% N/A 12 months N/A
micron (1psi)

Down to 0.01 <140 mbar


AAR Dry Particulate N/A 99.9999% N/A 12 months AR
micron (2psi)
OIL-X EVOLUTION
Filtration Grades

Initial
Max Remaining Initial Dry Change Precede
Filtration Filter Particle Filtration Saturated
Oil Content at Differential Element with
Grade Type removal Efficiency Differential
21°C (70°F) Pressure Every Grade
Pressure

Oil Vapour 0.003 mg/m3 <350 mbar


OVR N/A N/A N/A 6000 hrs* AA
Removal 0.003 ppm(w) (5psi)

When oil
Oil Vapour 0.003 mg/m3 <200 mbar vapour
ACS N/A N/A N/A AA
Removal 0.003 ppm(w) (3psi) or odour is
detected
When oil
Oil Vapour 0.003 mg/m3 <775 mbar vapour
AC N/A N/A N/A AO
Removal 0.003 ppm(w) (11psi) or odour is
detected
Respiratory and Medical Products

● Breathing Air Dryers ● Medical Air Dryers ● Vacuum pump Exhaust Filters
● Medical Vacuum Filters ● Helium Gas Filters ● Portable Breathing Air Dryers
● Sterile Air Filters

16
CHILLER - Hyperchill
Precision Chilled Water
Used for –
 Product cooling
 Process cooling
 Equipment cooling
 Cutting Oil
Benefits –
 Compact
 High Reliability
 Very low nose levels
 Low energy consumption
Hyperchill
Technical
Specifications
• Min 5°C – Max 45°C ambient
Temperature Range
• Min 5°C – Max 30°C inlet
Cooling Capacity • 3 kW – 760 kW ICE
Range • 5 kW – 116 kW HLS
Electrical • ICE: 50Hz or 60Hz UL listed
Connections • HLS: 50Hz

Refrigerant • R407c

• IP33 & IP44 for smaller sizes


Protection Index
• IP54 from ICE015 & HLS022

18
Gas Generation
Analytical Gas Systems

 Hydrogen Gas Generators


 Nitrogen Gas Generators
 Zero Air (Hydrocarbon free) Gas Generator
 CO2 free Air
 TOC (total organic carbon) free Air
 Clean Dry Air
 Combination Gas generators (E.g. H2 + Zero
Air)

19
Gas Generation
Analytical Gas Systems

20
Analytical Gas Systems
Hydrogen Generators

 PEM (Proton Exchange Membrane) and Palladium


membrane technology
 Flow rate : 100 to 1,300 cc/min
 Purity : 99.9995% ~ 99.99999+%

21
Analytical Gas Systems
HP & UHP Nitrogen Generators

 Flow rate : 550 cc/min to 14 liters/min


 Purity : 99.5% ~ 99.9999% with respect to O2
 With or without built-in compressors

22
Analytical Gas Systems
Zero Air Generators

 Flow rate : 1 to 30 liters/min. Available in 140 and 280


liters/min
 Particles removal down to 0.01 µm
 Hydrocarbon content < 0.1 ppm
 Explosion-proof model available for 1 Liter/min flow

23
Gas Generation
Industrial Gas Generation

PSA Nitrogen Generators Membrane Nitrogen Generators


 Purity – 95% to 99.9995% Purity – 95% to 99.5%

24
Instrumentation & Gas Sampling Filter

● Bypass or High Pressure Filters ● Particulate Filters ● Small Volume Filters (Glass)
● Aluminium Clear Bowl Filters ● Small Volume Filters (SS) ● High Flow SS Filters
● Low Flow, Dual-Stage In Line Filters ● Nylon Filters ● Disposable Inline Filters

25
Biogas/Landfill Gas Treatment Product

● Shell & Tube Coolers ● Demister/Separators ● Biogas Filters ● Condensate Drains


● Water Chillers ● Siloxane removal systems

26
Natural Gas Filters and Dryer

● ATEX Compliant Natural Gas Filters (Cast & Fabricated, Threaded and Flanged)
● High Pressure CNG dispensing Filters ● CNG Natural Gas Dryers

27
Thank you!

You might also like