Professional Documents
Culture Documents
Cable - Supershot - Protomont 241.1 3x120+3x70E+Pilot
Cable - Supershot - Protomont 241.1 3x120+3x70E+Pilot
1
Extra heavy duty semi conductive screened cable
for mining applications including supply cable for
underground cutting machines and pumping.
222 Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773
PROTOMONT 241.1
APPLICATION
The 241.1 cable is specifically engineered for the Australian mining
industry and manufactured in accordance with AS 1802. It is an extra
heavy duty semi conductive screened cable for mining applications
including supply cable for underground cutting machines and pumping
DESIGN
The Protomont 241.1 cable is for aggressive environments in mining
where high mechanical stresses occur from reeling and trailing. A semi
conductive cradle separator encapsulates the central pilot core and
interstitial earth conductors. The semi conductive layer ensuring a high
conductivity low resistance earth circuit. The conductors consist of very
finely stranded tinned copper wires, rope laid to maximise flexibility.
The power cores have an inner semi-conductive layer around their
conductors. A reinforced polyester braid is embedded between the inner
and outer sheaths forming a vulcanised bond protecting against the
effects of torsional forces during operation. The specially compounded
CPE outer sheath resists damage from hard and abrasive surfaces
protecting the cable from mechanical damage.
OPERATING TEMPERATURE
■ Maximum permissible operating temperature
at conductor 90 °C
■ Maximum permissible short circuit temperature
at conductor 250 °C
(max. 5 s)
■ Minimum permissible temperatures
when in motion -25 °C
when stationary -40 °C
■ Maximum permissible water temperature 40 °C
Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773 223
PROTOMONT 241.1
VOLTAGE RATING
■ Rated voltage: Uo/U = 1.1kV
■ Maximum operating voltages in:
3 phase AC operation Uo/U = 1.1/1.1kV
DC operation Uo/U = 0.9/1.8kV
■ AC test voltage = 3kV
TENSILE STRENGTH
The maximum allowable tensile stress is 15N/mm2. This ensures no
conductor damage will occur in operation.
224 Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773
PROTOMONT 241.1
Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773 225
PROTOMONT 241.1
Selection and ordering data
mm2
PROTOMONT 3 x 6 + 3 x 3 /3E + pilot 5DM6 209
241.1 3 x 10 + 3 x 5 /3E + pilot 5DM6 212
3 x 16 + 3 x 8 /3E + pilot 5DM6 213
3 x 25 + 3 x13/3E + pilot 5DM6 214
3 x 35 + 3 x18/3E + pilot 5DM6 201
3 x 50 + 3 x 25/3E + pilot 5DM6 215
3 x 70 + 3 x 35/3E + pilot 5DM6 208
3 x 95 + 3 x 50/3E + pilot 5DM6 216
3 x 120 + 3 x 70/3E + pilot 5DM6 217
3 x 150 + 3 x 70/3E + pilot 5DM6 218
3 x 185 + 3 x 95/3E + pilot 5DM6 ***
3 x 240 + 3 x 120/3E + pilot 5DM6 ***
3 x 300 + 3 x 150/3E + pilot 5DM6 ***
226 Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773
PROTOMONT 241.1
Current ratings are based on AS/NZS 3008.1.1:2009.
mm mm kg/km A
84 x 0.30 31 1130 46
80 x 0.40 32 1200 66
126 x 0.40 34 1450 87
196 x 0.40 39 1800 116
304 x 0.30 42 2780 144
396 x 0.40 46.5 4530 183
546 x 0.40 51.6 4500 227
724 x 0.40 56.6 5600 273
926 x 0,40 62.6 7000 320
1156 x 0.40 69.1 8150 363
1406 x 0.40 73.3 9770 415
1862 x 0.40 81.6 12750 489
1456 x 0.50 88.2 15870 558
Sales & Order Processing Phone 131 773 then press 1 Fax 1800 060 773 227