Professional Documents
Culture Documents
Final Abiera Duplexplan Mechanical
Final Abiera Duplexplan Mechanical
Final Abiera Duplexplan Mechanical
7. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH INSULATION 7. FCU (CC) FAN COIL UNIT (CEILING CASSETTE)
TYPICAL TO REFRIGERANT PIPING. (REFER TO PIPE INSULATION DETAIL.)
8. ALL DUCT WORKS SHALL BE PROVIDED WITH ANGULAR BAR SUPPORTS. (SUBMIT 8. FCU (CS) FAN COIL UNIT (CEILING SUSPENDED)
SHOP DRAWING PRIOR TO INSTALLATION)
9. THE CONTRACTOR SHALL SUBMIT CATALOUGE / BROCHURES SUBJECT FOR 9. FCU (WM) FAN COIL UNIT (WALL MOUNTED)
FURTHER TECHNICAL EVALUATION BY THE CONCERNED AUTHORITY (BOD)
PRIOR TO PROCUREMENT / INSTALLATIONOF THE EQUIPMENT/UNIT.
10. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH 10. W-2 WINDOW TYPE AC
INSULATION TYPICAL TO REFRIGERANT PIPING. (REFER TO PIPE
INSULATION DETAIL.)
11. SP-3 (CS) SPLIT TYPE ACU (CEILING SUSPENDED)
11. ALL NECESSARY GOVERNMENT PERMITS SHALL BE SECURED AND FOR ACCOUNT OF
THE CONTRACTOR.
12. AS-BUILT PLANS SHALL BE PROVIDED BY THIS CONTRACTOR AFTER COMPLETION OF 12. VD VOLUME DAMPER
WORKS.
13. ALL INSTALLATION WORKS SHALL BE DONE IN A NEAT AND WORK- MANLIKE MANNER. 13. RAG REGISTER AIR GRILLE
16. ALL ACCU's AND FCU's SHALL BE PROVIDED WITH ANGULAR BAR SUPPORTS.
SUBMIT SHOP DRAWING PRIOR TO INSTALLATION)
16. CF CEILING FAN
17. ALL ACU DRAIN SHALL TAP TO NEAREST STORM DRAINAGE.
PRC NO: PROJECT & LOCATION: SHEET CONTENTS: APPROVED: SHEET NO.
PTR NO:
CONSTRUCTION OF TWO (2) - STOREY
DATE: MILAGROS ABIERA M-1
PLACE:
RESIDENTIAL BUILDING
OWNER
1 3
PROFESSIONAL MECHANICAL ENGINEER TIN: 511 PETUNIA ST., QUEENS ROW SUBDIVISION, BACOOR, CAVITE
PRC NO: PROJECT & LOCATION: SHEET CONTENTS: APPROVED: SHEET NO.
PTR NO:
CONSTRUCTION OF TWO (2) - STOREY
DATE: MILAGROS ABIERA M-2
PLACE:
RESIDENTIAL BUILDING
OWNER
2 3
PROFESSIONAL MECHANICAL ENGINEER TIN: 511 PETUNIA ST., QUEENS ROW SUBDIVISION, BACOOR, CAVITE
A B C D E A B C D E
1 1
LAUNDRY LAUNDRY
AREA A AREA B MASTER T&B A MASTER T&B B
CR A1 CR B1
2 2 ACU DRAIN ACU DRAIN
KITCHENETTE
ACU DRAIN
BEDROOM A-2
ACU DRAIN
DINING AREA B
3 3 CR B2
ACU DRAIN
ACU DRAIN
KITCHEN A &
BEDROOM A-1 LIVING AREA B DINING AREA A
BEDROOM B2
4 ACU DRAIN
4
UP
UP
STO.
DOWN
DOWN
5 5
FOYER A FOYER B
LIVING AREA A BEDROOM B1
PLANT PLANT
BOX BOX
7 LOT LINE 7
PRC NO: PROJECT & LOCATION: SHEET CONTENTS: APPROVED: SHEET NO.
PTR NO:
CONSTRUCTION OF TWO (2) - STOREY
DATE: MILAGROS ABIERA M-3
PLACE:
RESIDENTIAL BUILDING
OWNER
3 3
PROFESSIONAL MECHANICAL ENGINEER TIN: 511 PETUNIA ST., QUEENS ROW SUBDIVISION, BACOOR, CAVITE