Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Republic of the Philippines

Department of Education
Region VI – Western Visayas
Schools Division of Roxas City
CONGRESSMAN RAMON A. ARNALDO HIGH SCHOOL
(Technical – Vocational High School)
Banica, Roxas City

2ND QUARTER SUMMATIVE TEST


IN EIM 10

I. Multiple Choice.

Direction: Choose the letter of the correct answer and write it on the space provided before each number.

______1. This is usually bare solid or stranded conductor used for overhead transmission lines and ground wires.
A. Copper or aluminum conductor
B. Non-metallic Sheath Cable (type NM)
C. Thermoplastic covered fixture wire (type TF)
D. Copper or aluminum PE insulated line wire
______2. This is a flame retardant, moisture resistant wire used for building wiring installation in dry or wet locations.
A. Thermoplastic Portable Cords (Type SJT and ST)
B. Thermoplastic wire (type TW)
C. Control Cable (braided type)
D. Flat Cord (type SPT)
______3. A wire commonly used for wiring motorized engines and appliances with high temperature, and for switch board wiring.
A. Temperature wire (HI)
B. Control Cable (braided type)
C. Asbestos-covered nickel cord (rockbestos)
D. Steel tape armored power cable with ground wire (copper)
______ 4. This is a multi-conductor cable generally used for interior wiring installation in dry and wet location.
A. Power cable C. Royal cable
B. Non-metallic sheath cable (type NMC) D. Submersible pump cable
______5. What is the equivalent diameter size of No.10 AWG wire in millimeter (mm)?
A. 2.05 mm C. 3.26 mm
B. 2.59 mm D. 3.11 mm
______6. What is the equivalent diameter size of No.8 AWG wire in millimeter (mm)?
A. 2.05 mm C. 3.26 mm
B. 2.59 mm D. 3.11 mm
_______7. It is a type of armored flexible cable that has rubber insulation.
A. Type AC C. Type ACV
B. Type ACT D. Type ACL
_______8. The appropriate tool used in cutting flexible armored cable.
A. Pliers C. Hacksaw
B. Backsaw D. Knife
______9. What do you call a metal or plastic material that is used for mounting of convenience outlets and switches on wall?
A. Junction box C. Utility box
B. Frames D. Fitting
_____10. It is used for branching conductors and enclosing splices.
A. Utility box C. Junction box
B. Fastening device D. Adhesive
_____11. What is the safety device that automatically cuts-off current that exceeds the circuit rating?
A. Circuit C. Conduit
B. Circuit breaker D. Galvanic Reaction
_____12. It is a conduit fitting used to make a 900 change in direction of the conduit run a quarter bend?
A. Coupling C. Nipples
B. Offset D. Elbow
_____13. It is a process of removing sharp edges or burrs left after cutting a pipe.
A. Shaping C. Finishing
B. Reaming D. Smoothing
_____14. How many degrees in the direction of conduit run does a quarter angle bend provides?
A. 45 degrees C. 135 degrees
B. 90 degrees D. 180 degrees
_____15. It is the maximum recommended number of 8.0 mm (No.8 AWG) wires a 20 mm (3/4 inch) conduit can
accommodate.
A. 6 C. 10
B. 8 D. 12
_____16. What size of conduit can accommodate at least ten 8.0 mm (No.8 AWG) wires?
A. 3/8 inch C. ¼ inch
B. ½ inch D. 1-¼ inch
_____17. It is a type of conduit which makes conduit run turns to the right.
A. C C. LB
B. LL D. LR
_____18. What is the standard length of Rigid Metallic Conduit?
A. 10 feet C. 14 feet
B. 12 feet D. 20 feet
_____19. It is a type of fitting which is used to change direction.
A. connector C. adaptor
B. coupling D. elbow
_____20. It is a short length conduit or tubing which is used to extend a conduit system and also used between conduit and tubing
such as boxes or enclosures between two boxes.
A. connector C. adaptor
B. coupling D. elbow
_____21. A wire used for wiring electrical ranges, water heaters, stoves and hairdryers where both heat and moisture resistance is
desirable.
A. Duralene (Type WP) C. Asbestos-covered Nickel Cord
B. Coaxial Cable D. Steel Tape Armored Power Cable with Ground Wire
_____22. A wire commonly used for wiring motorized engines and appliances with high temperature, and for switch board wiring.
A. Temperature Wire (Type HI) C. Asbestos-covered Nickel Cord
B. Themoplastic Wire (Type TW) D. Coaxial Cable
_____23. This is a multi-conductor cable generally used for interior wiring installations in dry and wet locations.
A. Durex Wire C. Asbestos-covered Nickel Cord
B. Non-metallic Sheathed Cable D. Steel Tape Armored Power Cable with Ground Wire
_____24. This wire or cable is used for radio frequency antenna installation, and radar transceiver installation.
A. Control Cable C. Duralene (Type WP)
B. Royal Cord D. Co-axial Cable
_____25. This wire or cable has 2, 3, or 4 conductors, stranded, and used for portable cords in electrical equipment.
A. Control Cable C. Duralene (Type WP)
B. Royal Cord D. Co-axial Cable
_____26. This is a polyethylene-insulated line wire used for wiring installation of residential buildings.
A. Intercom Cable C. Duralene (Type WP)
B. Royal Cord D. Flat Cord (Type SPT)
_____27. This is the maximum ampacity of a 5.5 mm2 copper with type THHN insulation if the conductor is to be used in an area
with an ambient temperature of 390 C.
A. 40 A B. 36 A C. 35 A D. 34 A
_____28. This wire cannot be used in wet location.
A. TW B. THW C. THHN D. THWN
_____29. This is the maximum operating temperature of a THHN wire.
A. 600 C B. 750 C C. 850 C D. 900 C
_____30. A copper conductor is to supply an air conditioning load which has a nameplate rating of 22 A. What size of THWN wire
is safe and economical to use?
A. 8.0 mm2 B. 2.0 mm2 C.3.5 mm2 D. 5.5 mm2
_____31. A picture or symbol intended to alert or instruct a person on how to avoid a potentially hazardous
condition.
a. electrical signs c. electrical sketch
b. electrical symbols d. electrical figures
______ 32. An electrical sign which means any activity is not allowed or prohibited.
a. caution c. prohibition
b. danger d. halt
______ 33. It is the unit of electric current.
a. ampere c. watt
b. volt d. ohm
______34. An electrical sign that indicates some precautionary measures against potentially hazardous situation, which, if not
avoided may result to a minor or moderate injury.
a. stop! c. warning
b. caution d. danger
______ 35. It is the unit of electrical resistance.
a. ampere c. watt
b. volt d. ohm
______ 36. It is the unit of electrical power.
a. ampere c. watt
b. volt d. ohm
______ 37. A kind of drawing which shows the object in three dimensional view.
a. isometric drawing c. orthographic drawing
b. sketch d. plan
______ 38. A drawing that shows the top front and side view of an object.
a. isometric drawing c. orthographic drawing
b. sketch d. plan
______ 39. The unit of electrical pressure or electromotive force.
a. ampere c. watt
b. volt d. ohm
_____ 40. An electrical sign that specifies hazardous situation, which, if not avoided, will result to serious injury or even death.
a. stop! c. warning
b. caution d. danger
_____ 41. It is the unit of apparent electrical power.
a. volt c. ohm
b. watts d. volt-ampere
_____ 42. Two (2) Kilowatts is equal to:
a. 200 watts c. 1000 watts
b. 20 watts d. 2000 watts
_____43. The unit of electrical energy or work performed.
a. kilowatt-hour c. ampere-hour
b. kilovolt-hour d. kilometer
_____44. Small drawings or pictograms used to represent various electrical devices in an electrical diagram or plan.
a. electrical signs c. electrical sketch
b. electrical symbols d. electrical figures
_____ 45. The PEC is used nationally as the basis for safeguarding persons, buildings and its contents from hazards that may arise
from the use of electricity. PEC stands for;
a. Philippine Electrical Corporation c. Philippine Electrical Code
b. Philippine Electrical Commission d. Provincial Engineering Corps
______46. It is a written or printed request of something that is needed. It is also called Purchase Request Form.
a. job order form c. requisition slip form
b. inventory form d. borrower’s form
______47. A list of tools, equipment or materials made on a particular date by a qualified personnel. It also provides information on
the quantity and condition of the items listed.
a. job order form c. requisition slip form
b. inventory form d. borrower’s form
______48. A ‘terms and conditions” on borrowing tools or equipment is found on this form.
a. borrower’s form c. requisition slip form
b. inventory form d. job order form
______49. An electrical equipment that is used to make holes on metal sheets, wood or concrete.
a. portable electric grinder c. electric planer
b. portable electric drill d. screw driver
______50. A device inserted into a convenience outlet to conduct electric current.
a. socket c. tester
b. plug d. screw driver

Prepared by;

JOHN REY H. VIDAL


Teacher I – TVE

You might also like