The status panel report provides information about a Yaskawa drive including:
- The drive type and software version in use
- The project name and user logged in
- Main status and I/O status of the drive
- Details of the last fault which was a main circuit overvoltage
- Monitor signals and fault history are listed but do not have values selected
The status panel report provides information about a Yaskawa drive including:
- The drive type and software version in use
- The project name and user logged in
- Main status and I/O status of the drive
- Details of the last fault which was a main circuit overvoltage
- Monitor signals and fault history are listed but do not have values selected
The status panel report provides information about a Yaskawa drive including:
- The drive type and software version in use
- The project name and user logged in
- Main status and I/O status of the drive
- Details of the last fault which was a main circuit overvoltage
- Monitor signals and fault history are listed but do not have values selected
Reverse Terminal S2 Fault output Ready Terminal S3 Fault Terminal S4 Data Setting Error Terminal S5 Terminal S6 Terminal S7 Terminal S8 Digital Output (M1-M2) Digital Output (M3-M4)
Monitor Signal Signal Value
Signal 1: No Signal Selected 0
Signal 2: No Signal Selected 0 Signal 3: No Signal Selected 0 Signal 4: No Signal Selected 0 Signal 5: No Signal Selected 0 Signal 6: No Signal Selected 0 Signal 7: No Signal Selected 0 Signal 8: No Signal Selected 0
DriveWizard Industrial for Windows (C) by Yaskawa America, Inc. 1/2
Fault History Monitor Code Description
U2-01 Current fault - -
U2-02 Last fault ov Main Circuit Overvoltage U3-01 Most recent fault ov Main Circuit Overvoltage U3-02 Second most recent fault - - U3-03 Third most recent fault - - U3-04 Fourth most recent fault - - U3-05 5th Most Recent Fault - - U3-06 6th Most Recent Fault - - U3-07 7th Most Recent Fault - - U3-08 8th Most Recent Fault - - U3-09 9th Most Recent Fault - - U3-10 10th Most Recent Fault - -
Fault Trace Monitor Value
U2-02 Last fault ov
U2-03 Frequency reference at fault 401.1 Hz U2-04 Output frequency at fault 398.0 Hz U2-05 Output current at fault 531.0 A U2-06 Motor speed at fault 0.0 Hz U2-07 Output voltage at fault 369.4 VAC U2-08 DC bus voltage at fault 760 VDC U2-09 Output power at Fault 323.0 kW U2-10 Torque reference at fault 0.0 % U2-11 Input terminal status at fault 00000001 U2-12 Output terminal status at fault 00000001 U2-13 Operation status at fault 00100001 U2-14 Cumulative operation time at Fault 2701 H U2-15 Speed Reference during Fault at Soft Start 398.0 Hz U2-16 Motor q-Axis Current during Fault 201.1 % U2-17 Motor d-Axis Current during Fault -75.3 % U2-19 d-q Axis Deviation Error at fault 0.0 deg U2-20 Fin Temperature 56 deg