*Baseline pain level/MMT !!!!!!!!

EPT  I  
 US  
Parameter  &  Dosage   Physiological  Effect   Therapeutic  Effect   Contraindication  
-­‐ SH:  Rx  area/3-­‐4   Thermal   -­‐ Promote  healing   -­‐ Pregnancy  over  hip/back/abd  
-­‐ TA:  no.  of  SH/1.5   -­‐ Improve  blood  flow   o Stimulate  cellular  activities   -­‐ Malignancy  
-­‐ Rx  Time  (min)   -­‐ Increase  pain  threshold   o Stimulate  capillary  growth   -­‐ Post  radiotherapy  
o Acute:  1-­‐2/TA   -­‐ Change  nerve  conduction  velocity   o Proliferation  of  capillary   -­‐ Cardiac  pacemaker  &  neural  
o Subacute/Chronic:  2-­‐3/TA   -­‐ Promote  healing   o Break  down  adhesion   implant  
-­‐ Freq.   -­‐ Increase  extensibility   o Increase  extensibility   -­‐ Metal  implant  
o 1MHz:  Deep  (1-­‐2cm)   Mechanical   -­‐ Pain  relief   -­‐ Acute  infection  
o 3MHz:  Superficial  (3-­‐6mm)   -­‐ Cavitation   -­‐ Break  down  scar   -­‐ Vascular  abnormalities  
-­‐ Intensity  (W/cm2)   o Tiny  bubble   -­‐ Normalize  microcirculation   o DVT  
o Acute:  0.5-­‐0.8   o Alter  cell  function   -­‐ Activate  macrophage  reaction   o Severe  atherosclerosis  
o Subacute:  0.8-­‐1.0   -­‐ Acoustic  streaming     acute: stimulate cellular activities; promote o Severe  ischemic  tissue  
o Chronic:  1.0-­‐1.5   o Alter  permeability   -­‐ Recent  venous  thrombosis  
cell membrane permeability (non-thermal)
-­‐ Mode   o Alter  metabolic  process   -­‐ Risk  of  hemorrhage  
proliferative: angiogenesis, fibroblasts
o Acute:  P1:4(20%)   -­‐ Micro-­‐massage   o Hemophiliac  
o Subacute:  P1:2(33%),   o Enhance  fluid  interchange   proliferation -­‐ Over  
P1:1(50%),  Cont’d   o Reduce  edema   remodelling: increase extensibility of o Eye  &  testes  
o Chronic:  Cont’d     collagen, break down adhesion o Stellate  ganglion  
o Cardiac  area  
o Exposed  nerve  tissue  
o Cranium  
o Active  epiphyseal  region  
Preparation   Application   Indication   Precaution  
-­‐ Test   -­‐ Gel   -­‐ TE   -­‐ Anesthetic  area  
o Sharp  &  Blunt   o Smooth  contour   -­‐ OA  knee   -­‐ Subcutaneous  nerve  
o Hot  &  Cold   -­‐ Water  immersion   -­‐ Shoulder  pain   -­‐ Bony  prominence  
-­‐ Checking   o Hand  &  Foot   -­‐ Pressure  sore   -­‐ Keep  moving  
o Cont’d  mode   o 2-­‐3cm  distance   small circular motion -­‐ CTS   carpal tunnel o Standing  wave  
§ Water  ripple   -­‐ No  pain,  discomfort  &  unexpected   -­‐ Heel  spur   -­‐ Perpendicular  
§ Gel  vibration   sensation   -­‐ Calcified  tendinitis   o Shear  wave  
-­‐ No  feeling  or  slightly  warm   -­‐ Localized  neck/back  pain   -­‐ Lowest  intensity  produce  
therapeutic  response  
warning: no pain, don't touch, danger of being burnt
Contraindication?
1. General health ok? (fever) 2. systemic disease (heart disease, hypertension, diabetes) 3. Circulation 4. Skin 5. Implant (metal, cardiac pacemaker, neural implant)
6. medication 7. Radiotherapy? Cancer?
 
SWD  
Parameter  &  Dosage   Physiological  Effect   Therapeutic  Effect   Contraindication  
-­‐ CSWD   -­‐ Electrical  field   -­‐ Thermal  effect  without  depolarize   -­‐ Cardiac  Pacemaker  /  Neural  
o Time:  15-­‐20min   o Vibration  of  ions   nerve  &  muscle   Implant  
o Intensity  (0-­‐1000W)   o Molecular  distortion   o Increase  metabolic  rate   -­‐ Metal  Implant  
§ Adjustment   -­‐ EM  field   o Increase  extensibility   -­‐ Malignant  tumor  
• Dial   o Dipole  rotation   o Improve  circulation   -­‐ Active  TB  
• Distance   -­‐ CSWD   o Pain  relief   -­‐ Open  wound  
o Deep  heat   vasodilation -­‐ Promote  healing   -­‐ Acute  inflammation  
• Towel  
-­‐ PSWD  (100-­‐1000W)  for  Acute   o Decrease  viscosity   -­‐ Impair  thermal  sensation  
o Pulse  freq.:  15-­‐200Hz   o Increase  metabolic  rate   -­‐ Impair  circulation  
§ Acute:  20-­‐82Hz  (100-­‐200W)   o Increase  extensibility   o Thrombosis  
§ Subacute  &  chronic:  200Hz   o Pain-­‐gate  (heat)   o Unstable  BP  
(1000W)   -­‐ PSWD   -­‐ Danger  of  Hemorrhage  
o PD:  400μs  (fixed)   o Restore  cell  membrane   o Hemophiliac  
o Minimal  thermal  effect  (mean   potential   o Menstruating  
power  <25W)   o Restore  membrane  transport  &   -­‐ Pregnancy  
§ 20-­‐40Hz:  1000W   W ion  balance   -­‐ Inability  to  communicate  
§ 40-­‐110Hz:  400-­‐800Hz  
§ 150-­‐200Hz:  100-­‐200W  
Preparation   Application   Indication   Precaution  
-­‐ Test   -­‐ Capacitor  field  (E  field)   -­‐ CSWD   -­‐ Cables  
o Hot  &  Cold   o Disc/Pad  x  2   o OA   o Not  contact  with  patient  
-­‐ Checking   o Contraplanar  cross-­‐fire  /   o Chronic  neck  /  back  pain   o Not  contact  with  each  other  
o Neon  tube   coplanar  /  longitudinal   o Frozen  shoulder   (<25mm)  
o Same  size,  even  space,  parallel,   o Muscle  /  tendon  /  ligament   o Fully  plugged  
Tune the machine
larger  than  body  part   injury   -­‐ Moisture  skin  
put hand under electrode to test the warmth -­‐ Inductothermy  (E  field  +  EM   o Deep  tissue  injury   -­‐ Metal  /  synthetic  material  
field)   -­‐ PSWD   o Watch  
o Diplode/Drum/Flexiplode   o Chronic  condition   o Jewelry  
o Eddy  current   § Pressure  sore   o Metal  bras  
o More  on  muscle   § Open  wound   o Clothes  
-­‐ PSWD  through  wet   o Metal  within  30cm  
dressing/metal  implant   -­‐ Thick  layer  of  subcutaneous  fat  
-­‐ Comfortable  warm  but  not  hot   -­‐ Hearing  aid  should  turn  off  
-­‐ Start  with  mild  warm  only   -­‐ 3m  between  SWD  and  other  
electrical  equipment  
  *Check wet surface *Towel cover untreated area
***Take out all the metal before starting the treatment
 
TENS  
Preparation  &  application   Effect   Indication   Contraindication  &  Precaution  
-­‐ Test   Pain  relief  (Aβ)   -­‐ LBP   -­‐ Cardiac  Pacemaker  /  Neural  
o Sharp  &  Blunt   -­‐ Gate  control  theory   -­‐ Neck  Pain   Implant  
-­‐ Checking   o Stimulate  large  diameter  fiber   -­‐ Post-­‐op  pain   -­‐ Epilepsy  
o On  self   -­‐ Endorphin  release  (Aδ)   -­‐ Labour  pain   -­‐ Over  Carotid  Sinus  
-­‐ Skin  preparation   o Morphine  like  substance   -­‐ Cancer  pain   -­‐ Anterior  Neck  
o Clean  with  warm  water  &  soap   -­‐ Descending  pain  suppressing   -­‐ Phantom  pain   -­‐ Transthoraxic    
-­‐ Placement   system  (Aδ)   -­‐ Frozen  shoulder   -­‐ Pregnant  Uterus  
o Pain  area   o Long  application  (30-­‐60min)   -­‐ Post  stroke  shoulder  pain   -­‐ Acute  inflammatory  condition  
o Same  dermatome   o Aδ  fiber  provoke  impulse  in   -­‐ OA   -­‐ Malignant,  TB,  Osteomyelitis  
o Opposite  border  of  post-­‐op   midbrain  à  track  down  spinal   -­‐ Precaution  
wound   cord  à  inhibit  nociceptive   o Eye  
o Harmful  on  bony  surface   neuron   o Inability  to  communicate  
-­‐ Involve  noradrenalin  &  serotonin   o Open  wound  
o Metal  implant  
 

  Freq.   Intensity   PD   Rx  Time   Feel   Application  


Low  
Conventional   30-­‐ Paresthesias   Acute  Pain  
High  (80-­‐120Hz)   Mild  à  gradual   Short  (30-­‐75μs)  
(  Aβ)   60min   Tingling   1st  Rx  of  chronic  pain  
increase  
Acupuncture     High   Rhythmic  
Low  (1-­‐4Hz)   Long  (150-­‐250μs)   45min   Chronic  dull  pain  
(  Aδ)   Max  tolerable   Pulsing  
BF  (2-­‐4Hz)  Burst  on/off  fixed   Muscle  twitch  
Burst         Deep  aching  chronic  pain  
High  (70-­‐100Hz  /  burst)   Surging  
Quick  &  profound  
High   Strongest  
Brief  Intense   High  (100-­‐150Hz)   Long  (150-­‐250μs)   <15min   analgesia  
Max  tolerable   Less  tolerable  
5-­‐10min  (<15min)  
Oscillate  40-­‐100%   Oscillate  40-­‐100%  
Modulation         Minimize  accommodation  
Oscillation  time  0.1-­‐1.5s   Oscillation  time  0.1-­‐1.5s  
NMES  
 
Parameter  &  Dosage   Progression   Contraindication  
-­‐ PD:  1ms   -­‐ Increase  intensity   -­‐ Cardiac  Pacemaker  /  Neural  
-­‐ Freq.:  0-­‐100Hz  (increase  for  more  sustain  contraction)   -­‐ Increase  frequency   Implant  
-­‐ Train:  1-­‐10/min  (usually  4/min)   -­‐ Increase  on  time   -­‐ Near  Heart  &  ANS  
-­‐ Intensity:  Max.  Tolerable  until  response  is  noted  (tolerable  &  comfortable)   -­‐ Decrease  off  time   o Change  cardiac  rhythm  /  
-­‐ Repetition:  10x3   -­‐ Increase  number  of   autonomic  effect  
  contraction  (treatment   -­‐ Pregnant  uterus  
  Severe  Weakness   Moderate  Weakness   Mild  Weakness   duration)   -­‐ Open  wound  
Freq.   3-­‐10Hz   10-­‐30Hz   30-­‐50Hz   -­‐ Add  active  contraction   -­‐ Infection  
On   2-­‐3s  à5s   5-­‐10s   10-­‐15s   -­‐ Hemorrhage  
Off   25-­‐50s   20-­‐30s   10-­‐30s   -­‐ Acute  inflammation  
Rx  Time   5-­‐10min   15min   15min   -­‐ Inability  to  communicate  
-­‐ Malignant,  TB,  Osteomyelitis  
 

Indication  &  Effect   Application   Preparation   Precaution  


-­‐ Neuromuscular  facilitation   -­‐ Cont’d  for  set  intensity  à  change  to   -­‐ Test   -­‐ Metal  Implant  
-­‐ Muscle  re-­‐education  /  training   train  mode  after  set   o Sharp  &  Blunt   -­‐ Fragile  skin  
-­‐ Prevent  atrophy  /  post-­‐op   -­‐ Monopolar   -­‐ Checking   -­‐ DC  à  skin  irritation  
weakness  à  increase  muscle  bulk   o 1small  active  on  muscle  (Red)   o On  self   -­‐ Poor  circulation  
-­‐ Retain  muscle  strength   o 1  large  inactive  on  bony  part   -­‐ Skin  Preparation   -­‐ Electrode  should  not  touch  each  
-­‐ Reduction  of  spasticity   o Small  muscle   o Clean  with  warm  water  &   other  
-­‐ Maintain  /  increase  ROM   o Sufficient  far  away   soap    
-­‐ Train  peripheral  nerve  damage  with   -­‐ Bipolar   o Protect  lesion  with  
re-­‐innervation   o Equal  size   vaseline  
-­‐ Improve  circulation   o Parallel  to  muscle  fiber  
-­‐ Better  than  exercise  if  exercise   o Large  muscle  
intensity  limited  for  elderly  &   -­‐ Carbonized  rubber  with  sponge  
pre/post-­‐op   -­‐ Probe  with  wet  cloth  
o Motor  point  
-­‐ Some  redness  expected  
IFT  

Parameter  &  Dosage   Physiological  Effect   Therapeutic  Effect   Contraindication  


-­‐ CF:  4000Hz   -­‐ Similar  with  TENS   -­‐ Pain  relief   -­‐ Anticoagulation  drug  
-­‐ BF:  0-­‐100Hz   o Less  skin  resistance  à  less  dose   -­‐ Reduce  swelling   -­‐ PE,  DVT  (Suction)  
-­‐ Intensity:  Max  Tolerable   needed  à  more  comfortable   -­‐ Improve  circulation   -­‐ Not  follow  instruction  
-­‐ PD:  0.1ms   o Penetrate  deeper  than  TENS   -­‐ Reduce  muscle   -­‐ Cardiac  Pacemaker  /  Brain  
-­‐ Sensory   o Pain  relief   tightness   Stimulator  
o Freq.   § Gate  control  theory   -­‐ Muscle  strengthening  &   -­‐ Hemorrhage  
§ Acute:  80-­‐100Hz   § Endorphin  release   re-­‐education   -­‐ Epiphyseal  region  
§ Chronic:  10-­‐25Hz   § Descending  pain  suppressing   -­‐ Circulatory  problem  
o Intensity   system   -­‐ Infection  
§ Acute:  no  contraction   -­‐ Improve  circulation   -­‐ Transthoracic  application  
§ Chronic:  mild  to  mod.  Contraction   o Axon  reflex   -­‐ Pregnancy    
o Rx  Time:  10-­‐15min   -­‐ Reduce  muscle  tension   -­‐ Malignancy  
o Modulation   o Decrease  nerve  conductive  velocity   -­‐ Over  
§ BF:  0-­‐20Hz,  6s  up/  6s  down   -­‐ Massaging  effect   o Eye  
§ Intensity:  10%   o Anterior  neck  
§ Vector:  Max  intensity  in  1  or  2   -­‐ Carotid  sinus  à  Drop  BP  
channel  keep  changing   Preparation  &  Application   Indication   Precaution  
o Progression   -­‐ Sensation  test   -­‐ Sensory   -­‐ Suction  Cup  
§ Increase  intensity   o Sharp  &  Blunt   o Muscle,  tendon,   o Fragile  &  sensitive  skin  
§ Increase  treatment  time   -­‐ Sensory   ligament  injury   o Excessive  /  uneven  
-­‐ Motor   o Electrode:  Suction   o Chronic  pain   pressure  à  bruising  
o Freq.   (Subacute/Chronic)  /  Pad  (Swelling)   o Muscle  tightness   o Distinguish  suction  &  IFT  
§ Smaller  muscle:  0-­‐10Hz   o Arrange   o Joint  stiffness   current  
§ Larger  muscle:  30-­‐50Hz   § Quadripolar  cross  fire  /  Bipolar   -­‐ Motor   -­‐ Uneven  thickness  sponge  
o On  (off)   (pre-­‐modulate)   o Muscle  re-­‐education   -­‐ Abnormal  skin  sensation  
§ Severe  weakness:  2-­‐3s  à  5s  (25-­‐50s)   § Contraplanar  (cross  joint)  /   o Muscle  strengthening   -­‐ Cable  
§ Moderate  Weakness:  5-­‐10s  (20-­‐30s)   Coplanar  (superficial)   -­‐ Hx  of  epilepsy  
§ Mild  Weakness:  10-­‐15s  (10-­‐30s)   o Placement   -­‐ Advance  heart  disease.  Cardiac  
o Rx  Time:  10-­‐20min   § Spine  level   arrhythmia  
o Progression   § Along  nerve  root,  peripheral  nerve,   -­‐ Anterior  chest  
§ Increase  intensity   dermatome,  Myotome  
§ Increase  on  time   § Trigger  point  /  acupuncture  point  
§ Increase  no.  of  contraction   -­‐ Motor  
§ Add  active  contraction   o Pad  
o Bipolar  
*suction: tell patient the erythema is normal
SWD  vs  US  vs  HP  
  SWD   US   HP  
Heat  Depth   Deep   Superficial   Superficial  
Application   Problem  with     Easily  applied  
Difficulties   interference   Use  at  home  
Contraindication   More     Less    
Contact   No   Yes     Yes  
Treatment  Area   Large   Smaller   Large  /  Small  
 

IFT  vs  TENS  


  IFT   TENS  
Area   Large   Small  /  Acupuncture  point  
Effect   Sensory  /  Motor   Sensory  
Sensation   Strong   Mild  
Massage  Effect   Yes   No  
Depth   Deeper   Superficial  
Lasting   Longer   Shorter  
 