Catálogo Conveyor Components
Catálogo Conveyor Components
11-22
HEAVY DUTY
QUALITY
S I N C E
COMPLETE
CO
LE
AE
BE
SA
OT
VE
RA
LT
FE
NT
PRODUCT CATALOG
IO
LC
TY
TO
CL
RO
EA
RS
ON
GA
LS
CO
NE
TE
TR
www.conveyorcomponents.com
S
RS
TR
OL
OL
S
MODEL BA
10
MODEL FS
Flow Switch for Bulk Material 17
MODEL DB
Bulk material handling customers and Damaged Belt Detector
LEVEL CONTROLS
18
MODEL CT
processing industries have come to depend on Tilt Level Controls
MODEL CR
20
Roto-Level Control 24
Conveyor Components Company As a PREMIER MODEL DLC
Diaphragm Level Control 28
AERATION
manufacturer of conveyor controls, motion As a manufacturer of quality engineered products for the bulk handling
MODEL AD
Bin Aerator 30
industry throughout the world, Conveyor Components Company prides itself MOTION CONTROLS
controls, level controls, bin aerators, and as a leading supplier in both foreign and domestic markets by maintaining MAG-NEAT-O™
and expanding market share and pursuing new product opportunities. The Magnetically Coupled Motion Control 32
scope of the Conveyor Components Company Quality Management System MODEL BSD
conveyor belt cleaners. covers conveyor safety controls, motion controls, level controls, bin aerators, Belt Speed Detector
MODEL BSDC
34
skirtboard clamps, and conveyor belt cleaners, as certified by NQA Global for Compact Belt Speed Detector 36
ISO 9001:2015. MODEL RMS
TO MAINTAIN THIS LEADING ROLE WE: Non-Contact Motion Monitoring System 37
MODEL MSD
• Provide a quality product to the market that meet customers expressed Motion Sensing Control 38
requirements. MODEL CMS
Compact Motion Control 40
• Maintain good communication with customers MODEL CMS-DSPO
• Maintain the shortest possible lead time while pricing products Dual Setpoint & Pulse Output 43
competitively. BELT CLEANERS
• Continually improve designs, service, and products. MODEL SC
Skirtboard Clamp 42
• Comply with applicable standards, legislation, and regulations. MODEL BK
Rubber Belt-Kleen 43
• Focus on occupational, health & safety standards. MODEL BR
• Invest in our future for continued growth. Brush Type Belt Cleaner 44
MODEL SBR
• Provision of needed resources and infrastructure. Small Brush Type Belt Cleaner 46
Conveyor Components Company strives to maintain to highest standards of MODEL HS
Helically Shaped Rotary Brush 48
integrity. By strictly following and enforcing a high code of ethics we make our MODEL LP
company a better place to work and our community a better place to live. Blade Style Belt Cleaner 50
Conveyor Components Company ensures that we meet the needs of our MODEL FA
Spring Arm Belt Cleaner 52
internal and external customers by training our employees to understand MODEL PT/HPT
and support the requirements of our Management System. By focusing on Plow Style Belt CleanerS 54
continual improvement of our Management System, we will ensure meeting READY PRODUCTS
the future needs of Conveyor Components Company customers.
READY GATE
Self-Closing Safety Gate 56
Conveyor Components Company
®
MODEL
CABLE OPERATED SAFETY STOP
CONTROL FOR CONVEYORS
RS AVAILABLE MODELS
MODEL DESCRIPTION
NPT
SHPG.
WT.
TECHNICAL SPECIFICATIONS
Standard Construction - Rubber gaskets seal unit for outside
applications. Listed by UL for NEMA 4/4X dust-tight and rain
LBS. tight construction, applies to general purpose units.
RS-2 2 Single Pole Double Throw (SP/DT) Microswitches * 13 Housing - Cast aluminum. Epoxy coating available.
RS-5 2 Double Pole Double Throw (DP/DT) Microswitches * 13 Conduit Opening - 3/4” NPT standard. 1” NPT optional
2 Single Pole Double Throw (SP/DT) Microswitches and (non UL). All RS units have three conduit openings.
4 Conveyorcomponents.com Conveyorcomponents.com 5
PC
CONTROLS
MODEL
5-29/32”
[150 mm]
7”
1” [25 mm] [178 mm]
NPT CONDUIT
13/32” [10 mm]
FLAG ARM DIA. HOLES C/L OF HOUSING AND
FLAG ARM (TRIPPED POSITION) CONDUIT OPENING
CABLE OPERATED
(NORMAL POSITION)
16# PULL
FIELD
ADJUSTABLE
[76 mm]
SAFETY STOP SWITCH
[126 mm]
4-15/16”
3”
[70 mm]
[76 mm]
2-3/4”
Rugged Construction withstands
3”
the hardest usage, in the C/L OF HOUSING AND
3/4”
[19 mm]
harshest environments.
CONDUIT OPENINGS CONDUIT ENTRY
3-7/16” 7-3/4” 3-1/4” 1” - 11½ N.P.T. 3/4”
[87 mm] [197 mm] [83 mm] 3/8” [19 mm]
5” 2-7/8” [10 mm]
[127 mm] [73 mm] 1-1/4”
[32 mm]
FRONT VIEW (DOUBLE END UNIT) SIDE VIEW
MOUNTING PLATE
AVAILABLE MODELS
MODEL PCD-4SL SHPG.
ACCESSORIES
MODEL DESCRIPTION WT. CABLE SUPPORT EYE BOLT PIGTAIL-STYLE CABLE
1” eye x 6” zinc plated. SUPPORT EYE BOLT
LBS. ½”-13 x 2½” thread. 1/2” x 6” Plated, with
RUGGED CONSTRUCTION
Includes two nuts and (2) hex nuts and (1) lock
Left Ended unit with 2 Single Pole Double Throw one lock washer. washer.
PCL-2S 12
EXCLUSIVE FEATURES (SP/DT) Microswitches* PC-27 Item # RS-27P
WITHSTANDS THE HARDEST USAGE 1. The housing is cast aluminum, with optional epoxy coating PCR-2S
Right Ended unit with 2 Single Pole Double Throw
12
DOUBLE-ENDED CABLE
CABLE END FITTING
(SP/DT) Microswitches* SUPPORT EYE BOLT
The PC Stop Control can be used for emergency shutdown available (for additional corrosion resistance). Drilling is not required to Forged steel saddle and steel
of conveyor systems, elevator equipment, bulk handling install this cable support. U-bolt. Galvanized.
Dual Ended unit with 2 Single Pole Double Throw PC-28
systems, cranes, production and assembly lines, or any other 2. Single ended units are actuated via a cable pull from PCD-4S 16 Installs under idler
(SP/DT) Microswitches per end* bolt.
equipment which may require immediate, positive shutdown. one direction, while double-ended units can be actuated Item # RS-23 CONDUIT PLUG
from either or both directions. The model PC units come Right Ended unit with 2 Two Circuit Double Break 1” metal, socket
A cable is connected from a fixed point to the cable end PCR-2T 12
standard with a 16 lb. pull force, however units can be (TC/DB) Microswitches* SAFETY CABLE head conduit plug.
connection clevis. Pulling on the cable will actuate the switch, manufactured with a 25 lb pull force. Add “-25” to the end 3/32” x 7x7 preformed, PC-29
trip the flag arm down into the walkway and lock the switch Left Ended unit with 2 Two Circuit Double Break galvanized aircraft cable.
of the model number. PCL-2T 12 Available with either orange
in the actuated position. The unit is reset by returning the flag (TC/DB) Microswitches* vinyl or orange nylon
3. The unit is mounted on the conveyor by drilling (4) 13/32” protective coating.
arm to the normal up position. Dual Ended unit with 2 Two Circuit Double Break 3/16” O.D. PC MOUNTING
diameter holes. PCD-4T 16 BRACKET
(TC/DB) Microswitches per end* Vinyl Coated PC-25
PC-30
DETERMINATION OF NUMBER OF UNITS REQUIRED 4. General purpose (weatherproof) units and explosion proof Nylon Coated PC-26
Left Ended unit with 2 Single Pole Double Throw
The Model PC control is designed so that a maximum of units have (2) 1” NPT conduit openings. PCL-2SX 12
(SP/DT) Microswitches**
100 feet (30m) of cable can be used. The electrical
5. The units with “S” type microswitches (SP/DT) have dry, Right Ended unit with 2 Single Pole Double Throw
characteristics of the application will determine the type of
unpowered microswitch(es) rated for 20A @ 120 VAC, PCR-2SX 12
microswitches to be specified in the unit. The environmental (SP/DT) Microswitches**
240 VAC, and 480 VAC.
considerations will determine whether or not the unit is to Dual Ended unit with 2 Single Pole Double Throw
be explosion proof or require available epoxy coating. The 6. The units with “T” type microswitches (Two-Circuit Double- PCD-4SX 16
(SP/DT) Microswitches per end**
possibility of a light to aid in identification of actuated units Break) have dry, unpowered microswitch(es) rated for
should be considered. 15A @ 120 VAC, 240 VAC, 480 VAC and 600 VAC. Right Ended unit with 2 Two Circuit Double Break
PCR-2TX 12
(TC/DB) Microswitches**
Our galvanized aircraft cable with either vinyl or nylon 7. Highly visible red polyester powder coated flag arm for PCD-K PCLR-K
coating should be used with the control to assure proper Left Ended unit with 2 Two Circuit Double Break Double-ended (PCD units) Single-ended (PCL & PCR
quick identification of actuation. PCL-2TX 12 accessory mounting kit units) accessory mounting
actuation with no stretching. The cable should be supported (TC/DB) Microswitches** includes: 2 pieces (105 feet kit includes: 1 piece (105
by eyebolts every 8-10 feet (3m). These supports ensure that 8. Optional red warning light available for dark or remote each) pull cable (PC-25), feet) pull cable (PC-25),
locations. Dual Ended unit with 2 Two Circuit Double Break 20 eyebolts (PC-27), 8 10 eyebolts (PC-27), 4
the weight of the cable alone will not actuate the control. For PCD-4TX 16 cable clamps (PC-28), 1 cable clamps (PC-28), 1
(TC/DB) Microswitches per end** mounting bracket (PC-30). mounting bracket (PC-30).
ease of installation, we offer a kit (PCD-K and PCLR-K) that 9. The ambient temperature range is -14º-104°F (-25º- 40°C).
includes all components and correct quantities for the proper Dual Ended unit with 2 Single Pole Double Throw
PCD-4SD 16
installation of one unit. (SP/DT) Microswitches per end***
Right Ended unit with 2 Two Circuit Double Break LEFT HAND RIGHT HAND
PCR-2TD 12 PCL-1S PCR-1S
Eyebolts (TC/DB) Microswitches***
10’ SPACING
Left Ended unit with 2 Two Circuit Double Break
PCR-2S PCL-2S PCL-2TD 12
(TC/DB) Microswitches***
Dual Ended unit with 2 Two Circuit Double Break
PCD-4TD 16
(TC/DB) Microswitches per end***
*GENERAL PURPOSE NEMA TYPE 3, 3S, 4, 4X
Cable ends Cable ends ** EXPLOSION PROOF NEMA TYPE 7: Class I (Div. 1 & 2), Groups C, D; Type 9: Class II (Div. 1 & 2), Groups E, F, G
***DUAL RATED NEMA TYPE 4, Type 9: Class II (Div. 1 & 2), Groups E, F & G Compliant
100’ 100’ 100’ 100’
MAXIMUM MAXIMUM
PCD-4S MAXIMUM MAXIMUM
6 Conveyorcomponents.com 7
RSB
CONTROLS
MODEL RSB DIMENSIONAL INFORMATION
MODEL
SIDE VIEW FRONT VIEW
8-1/2” [216mm]
100’ [30.5m] MAX.
6”
The Model RSB is a heavy-duty safety control that provides a MOUNTING [152mm]
13/32” [10 mm]
dia. holes
positive shut off of dangerous equipment in an emergency. A PATTERN
cable pulled by endangered personnel actuates it. The output
contacts of the Model RSB can control up to two separate 1-3/8” [35mm]
circuits, one for machinery shutdown and one for an alarm. The 1-3/8” [35mm]
Model RSB has the built-in-advantage of cable break detection.
AVAILABLE MODELS
MODEL RSB-2 SHPG.
MODEL DESCRIPTION WT.
EXCLUSIVE FEATURES LBS.
BUILT IN BROKEN CABLE DETECTION 1. The housing is cast aluminum, with optional epoxy RSB-2 2 Single Pole Double Throw (SP/DT) Microswitches * 13
Designed to act as an emergency stop pull cord control on coatings available. RSB-5 2 Double Pole Double Throw (DP/DT) Microswitches * 13 RS-30 BRACKET for mounting the Model RSB
conveyors and other moving machinery that incorporates built-in stop switch to the conveyor stringer at an idler.
2. The unit can be actuated via a cable pull from either 2 Single Pole Double Throw (SP/DT) Microswitches and
broken cable detection. The Model RSB has extension springs, RSB-2L 14
direction, in other words, the unit is “double-ended”. Pull Red Incandescent signal lamp *
attached to opposite ends of the pull cable, which maintain the
cable is required on EACH side of RSB unit (+/- 5 feet).
cable under constant tension. The RSB is mounted so that it 2 Double Pole Double Throw (DP/DT) Microswitches and
is centered between the end springs. In this way, temperature 3. The unit is mounted on the conveyor by drilling (3) 13/32” RSB-5L 14
Red Incandescent signal lamp *
changes, which cause cable length changes, are canceled out. diameter holes.
The operating handle is held in the center vertical position with the RSB-2X 2 Single Pole Double Throw (SP/DT) Microswitches ** 13
4. All units have (3) 3/4” NPT conduit openings.
internal switch in a normally closed condition. RSB-5X 2 Double Pole Double Throw (DP/DT) Microswitches ** 13 Spring Tensioning Kit with cable
5. The standard units have dry, unpowered SP/DT safety link. (included with every RSB unit)
If the cable is pulled or the cable breaks, the handle rotates to microswitch(es) rated for 20A @ 120 VAC, 240 VAC, and 2 Single Pole Double Throw (SP/DT) Microswitches and
release the switch lever. In this way, the alarm signal is generated RSB-2XL 14
480 VAC; 1/2 amp at 125 VDC and 1/4 amp at 250 VDC. Red Incandescent signal lamp **
for either condition. The operating handle must be manually reset
back to the center position after the cause has 6. Special spring tensioning kits included with each RSB 2 DP/DT Microswitches and Red Incandescent signal RS PULL CORD ACCESSORY
RSB-5XL 14 MOUNTING KIT
unit provide stability due to temperature fluctuations, and lamp **
been corrected. Includes everything you need to
ease of cable adjustment. RSB-2D 2 Single Pole Double Throw (SP/DT) Microswitches *** 13
properly install the CCC MODEL
RS Pull Cord Safety Stop Switch.
DETERMINATION OF NUMBER OF UNITS REQUIRED 7. All models are rated ambient -13º to 104ºF RSB-5D 2 Double Pole Double Throw (DP/DT) Microswitches *** 13
(2) 105’ Pull Cable (RS-25)
The Model RSB control is designed so that a maximum of (-25º to 40ºC). (20) Eyebolts (RS-27)
(8) Cable Clamps (RS-28)
100 feet (30m) of cable can be used on each side of the unit. *GENERAL PURPOSE NEMA TYPE 1, 3, 3R, 4, 4X
8. The general purpose units are rated NEMA type 4/4X **EXPLOSION PROOF NEMA TYPE e 7: Class I (Div. 1 & 2), Groups C & D; Type 9: Class II (1) Mounting Bracket (RS-30)
A single control can therefore cover a maximum of 200 feet of Item # RS-K
weatherproof and corrosion-resistant. Explosion proof (Div. 1& 2), Groups E, F & G”
conveyor belt or other machinery. The electrical characteristics
units are rated NEMA type 7/9 for dust ignition proof ***DUAL RATED NEMA TYPE 3, 4, 4X; Type 9: Class II (Div. 1 & 2), Groups E, F & G
of the application will determine the type of microswitches to
and vapor explosion proof. Specifically, they are listed
be specified in the unit. The environmental considerations will CABLE SUPPORT EYE BOLT PIGTAIL-STYLE CABLE DOUBLE-ENDED CABLE
for Class I, Div. 1, Groups C and D; and Class II, Div. 1, SUPPORT EYE BOLT SUPPORT EYE BOLT
determine whether or not the unit is to be explosion proof or 1/2” x 6” plated 2-1/2” long
Groups E, F and G. The dual-rated “D” units are rated N.C. thread. 1” eye, two nuts 1/2” x 6” Plated, with (2) hex Drilling is not required to
require available epoxy coating. The possibility of a light to aid
NEMA type 4X weatherproof and NEMA type 9 dust and one lock washer. nuts and (1) lock washer. install this cable support.
in identification of actuated units should be considered. Item # RS-27 Item # RS-27P Installs under idler
ignition proof. Specifically, they are listed for Class II, bolt.
Our galvanized aircraft cable with either vinyl or nylon coating Groups E, F and G. Item # RS-23
should be used with the control to assure proper actuation
with no stretching. The cable should be supported by eyebolts 9. The general purpose controls meet or exceed IP65.
every 8-10 feet (3m). These supports ensure that the weight 10. UL Listed and CSA Certified.
of the cable alone will not actuate the control. For ease of SAFETY CABLE CONDUIT PLUG CABLE END FITTING
installation, we offer a kit (RS-K) that includes all components 3/32” x 7x7 preformed, 3/4” metal, socket Secures protective cable to
galvanized aircraft cable. head conduit plug. switch hand and supports.
and correct quantities for the proper installation of one unit. Protective coating in either Item # RS-28
Item # RS-29
orange coated vinyl or nylon. or # RS-29X
3/16” O.D.
Item # RS-25 (vinyl)
RS-26 (nylon)
8 Conveyorcomponents.com Conveyorcomponents.com 9
MODEL TA DIMENSIONAL INFORMATION
TA
CONTROLS
6”
TOP VIEW WITH 6-3/4” MOUNTING FEET 13/32” DIA.
[10 mm] [152 mm]
[171 mm]
COVER REMOVED DIMENSIONS
MODEL
1-3/8”
[35 mm]
1-3/8”
6” [35 mm]
[152 mm]
4” [102 mm]
CENTER LINES
Ø 1-1/4”
[32 mm]
ROLLER ARM
ALTERNATE ROLLER 9-3/4”
MOVES 90° IN [248 mm]
BOTH DIRECTIONS LENGTHS AVAILABLE
(5” to 12”)
AVAILABLE MODELS
SHPG.
MODEL DESCRIPTION WT.
LBS. EXCLUSIVE FEATURES
TA-2 2 Single Pole Double Throw (SP/DT) Microswitches* 11 1. MANUAL RESET: A positive lock-out model with manual reset is available. 11. Enclosure Ratings: TA-2, TA-4, TA-5: C-UL-US Types 3S, 4, 4X & 5.
Available only on General Purpose units. 12. TA-2X, TA-4X, TA-5X: C-UL-US for Class I, Groups C & D; Class II, Groups E, F
TA-5 2 Double Pole Double Throw (DP/DT) Microswitches* 11
2. SP/DT microswitches: Individually adjustable. Rated 20 amp at 125, 250, or & G; Class III Hazardous Locations.
TA-2X 2 Single Pole Double Throw (SP/DT) Microswitches** 11 480 VAC, 1/2 Amp 125 VDC; 1/4 Amp 250 VDC. 13. TA-2D, TA-4D, TA-5D: C-UL-US Types 3S, 4, 4X & 5; Class II, Groups E, F & G;
TA-5X 2 Double Pole Double Throw (DP/DT) Microswitches** 11 3. DP/DT microswitches: Individually adjustable. Rated 15 amp at 125, 250 VAC. Class III Hazardous Locations.
4. Switches may be wired for single throw operation, either normally open or 14. CERTIFICATION: cULus Listed.
TA-2D 2 Single Pole Double Throw (SP/DT) Microswitches*** 11 normally closed as required. 15. Special 5” (shorter) height roller available, add “-R5” to end of model number.
TA-5D 2 Double Pole Double Throw (DP/DT) Microswitches*** 11 5. STANDARD CONSTRUCTION: Rubber gaskets seal units against dust and Other alternate roller lengths available (5” minimum to 12” maximum, standard
rain for NEMA 4, 4X outdoor applications. Applies to weatherproof units only. style roller only, not ball bearing style).
*GENERAL PURPOSE NEMA TYPE 3S, 4, 4X, & 5 NEMA 7/9 units also available (without gasket). 16. Special 304 stainless steel roller (with red polyester powder coating) available,
“**EXPLOSION PROOF NEMA TYPE 7: Class I (Div. 1 & 2), Groups C & D; Type 9: Class II
6. HOUSING: Aluminum. Epoxy coating available. add “SS” to end of model number and $ to the price. Currently not available in
(Div. 1 & 2), Groups E, F & G”
7. CONDUIT OPENING: One 3/4” NPT conduit opening. ball bearing version.
***DUAL RATED NEMA TYPE Type 3S, 4, 4X, 5; Type 9: Class II (Div. 1 & 2), Groups E, F & G
8. ACTUATING ARM: Red powder-coated steel roller with stainless steel shaft. 17. Special roller with ball bearing ends available, add “-RBB” to end of model
number and $82.00 to the price. The “-RBB” roller is 9-3/4” inches in length,
9. EXTERNAL HARDWARE: Stainless steel.
same length as the standard roller. Shorter “-RBB” lengths possible, such as
10. All models are rated ambient -13º to 104ºF [-25º to 40ºC]. 5” (-RBB-R5), 6” (-RBB-R6), 7” (-RBB-R7), 8” (-RBB-R8) or 9” (-RBB-R9).
10 Conveyorcomponents.com Conveyorcomponents.com 11
BA
CONTROLS
MODEL BA DIMENSIONAL INFORMATION
MODEL
4”
3/4” [102 mm] 3/4”
[19 mm] [19 mm]
3/4” 2-1/2”
6-1/8” [19 mm] [64 mm]
4” [156 mm] 5-1/8”
[102 mm] [130 mm]
5-1/8”
4” 2-1/4”
[19 mm]
[19 mm]
2-1/2” [131 mm]
3/4”
3/4”
1-5/8” 7/8” [102 mm] [57 mm] 9/16”
[64 mm] [42 mm] [23 mm] [14 mm]
HOLES 7”
1-3/8” [35 mm] 4 Places [178 mm]
9/16” 3-1/8” ia. 3-1/4”
CONDUIT OPENING
CONVEYOR BELT RUN-OFF
[89 mm] [80 mm]
9”
1/2” - 14 NPSM
[229 mm]
7/8”
[13 mm]
[23 mm] 2-3/8”
1-1/4” [32 mm] [61 mm]
OPTIONAL
• Inexpensive protection for conveyor belts. 9/16” [14 mm] HOLES
1-5/16”
[34 mm]
SWITCH
BELTS FROM SEVERE DAMAGE then to get out of the way if the belt does run-off, preventing
serious damage to switches and belts. The breakaway mount
BA-1 1 Single Pole Double Throw (SP/DT) Microswitch* 1 18
Model BA heavy duty conveyor belt alignment control protects is spring loaded and automatically returns the Model BA to BA-1X 1 Double Pole Double Throw (DP/DT) Microswitch* 3 18
valuable conveyor belts from severe damage due to belt its original position when the conveyor belt is realigned. It is BA-2 1 Single Pole Double Throw (SP/DT) Microswitch** 2 21
misalignment or run-off. The Model BA makes sure that the designed so that the Model BA roller assumes a horizontal
belts are tracking properly. Prevents costly down time and position when the breakaway mounting is actuated. BA-2X 1 Double Pole Double Throw (DP/DT) Microswitch** 2 21
unnecessary maintenance expense. Designed especially for
bulk handling conveyor applications, it maintains a safeguard Breakaway mount is available with an optional microswitch
over equipment and keeps conveyor belts running. to indicate the breakaway condition has occurred. Thus, two
signals can be generated: First, a signal from the Model BA MODEL BA - ACCESSORIES
Sometimes called a “side slip switch” or a “belt misalignment unit that the belt has deviated. Second, a signal from the SWITCH ELECTRICAL RATINGS
switch,” the Model BA operates on a very simple principal. breakaway switch that the belt has deviated further. SHPG. WT.
MODEL DESCRIPTION 1. 20 Amp @ 125, 250, or 480 VAC:
Two controls are positioned close to the belt, one on each LBS 10 Amp @ 125 VAC “L”; 1 HP @ 125 VAC;
side, so that undesirable side to side motion of the belt will BA-5* Optional “Break Away” Mounting 10 2HP @ 250 VAC; 1/2 Amp @ 125 VDC;
contact a switch roller. The roller “gives” just enough to 1/4 Amp @ 250 VDC.
actuate the switch. The signal generated by the actuated Optional “Break Away” Mounting with additional SP/DT 2. 10 Amp @ 125 or 250 VAC; 0.3 Amp @ 125 VDC;
BA-55* 15
switch can be used to take appropriate action to re-align the Microswitch 0.15 Amp @ 250 VDC
conveyor belt, thus eliminating conveyor damage and serious BA-55 Optional “Break Away” Mounting with additional Explosion
3. 10 Amp @ 125, 250 or 480 VAC;
BA-55X* 15 1/2 Amp @ 125 VDC; 1/4 Amp @ 250 VDC.
down time. Proof SP/DT Microswitch
*BA Belt Alignment Control purchased separately
CONSTRUCTION AND OPERATION
The Model BA belt alignment control has two basic welded
steel components. The base housing and the roller housing. NUMBER OF UNITS RECOMMENDED
The roller housing contains the sensing roller and is attached No less than four alignment controls should be installed on each WELDED STEEL
to the base housing with a stainless steel pivot. The stainless conveyor, one on each side of the belt near the head and tail pulleys. ROLLER HOUSING ROLLER
steel pivot assures that movement will not be inhibited by For longer conveyors, we recommend an additional pair every 250 to STAINLESS STEEL
corrosion. The roller and roller housing together are designed 500 feet. BALL BEARINGS
(BOTH ENDS)
to pivot slightly when the roller is touched by the conveyor
LABYRINTH NYLON
belt. The roller housing assembly actuates an enclosed STAINLESS SEALS (BOTH ENDS)
switch mounted at the bottom of the base housing, it moves STEEL PIVOT
STAINLESS STEEL
approximately 1/4” to actuate the switch. A stainless steel
SPRINGS
spring is mounted with a bolt at the bottom of the roller
assembly to hold it away from the control except during WELDED STEEL
actuation. BASE HOUSING
Microswitches are housed in either the standard weather-tight, 1/2” CONDUIT
or optional explosion proof enclosures. SWITCH ACTUATOR OPENING
WITH RUBBER BOOT
The roller has stainless steel ball bearings and nylon labyrinth WEATHER TIGHT OR
seals to prevent corrosion and entry of water or dirt. EXPLOSION PROOF
Shown are two BA units protecting a valuable conveyor belt from damage MICROSWITCH
due to belt misalignment or run-off at an aggregate facility
12 Conveyorcomponents.com Conveyorcomponents.com 13
VA
CONTROLS
NEW & IMPROVED! MODEL VA TECHNICAL INFORMATION
properly. could also be wired to stop the conveyor motor. Drawing “A”
shows a range of roller orientations and the allowable travel for
Normally installed in pairs on each side of the conveyor belt each stage.
near the head pulley and/or the tail pulley, these heavy-duty
controls consist of a conveyor roller with sealed bearings, MODELS SPECIFICATIONS
four bar linkage and a double pole/double throw microswitch.
The roller detects any belt run-off and will trigger the first BELT CONTACT MODEL DESCRIPTION SHPG. WT. LBS. EXPLOSION PROOF MICROSWITCH
pole of the microswitch to sound a warning alarm, illuminate DRAWING “A”
P1 TO FLANGE GASKET • Meets NEMA Standards: 1, 3, 4, 6, 7, 9 and 13
P2 VA 1 sequential double break Microswitch * 10
an indicator light, or stop the conveyor completely when the FIELD ADJUSTMENT
vertical belt strays beyond 15° from horizontal. The second SCREWS VA-X 1 sequential double break Microswitch ** 10 • Class I, Div. 1, Groups B, C and D
pole is triggered when the belt strays 25° from horizontal and *GENERAL PURPOSE NEMA TYPE 3,4,4X, 6P & 13 • Class II, Div. 1, Groups E, F and G
can be wired to stop the conveyor motor. To eliminate false **EXPLOSION PROOF NEMA TYPE 1, 3, 4, 6, 13; Type 7: Class I (Div. 1 & 2), Groups B, C & D; Type 9:
signals the controls should be mounted about one inch away Class II (Div. 1 & 2), Groups E, F & G • UL Listed and CSA Certified
from the belt.
GENERAL PURPOSE MICROSWITCH
• Meets NEMA standards: 1, 3, 4, 4X, 6P and 13
• UL Listed and CSA Certified
ELECTRICAL OUTPUT
15° 10° • Double Pole/Double Throw
CT
TA • 10 Amp - 120, 240, 480 VAC
C ON LLER ON”
LT RO IS
BE ITH CH
W WIT • 0.8 Amp - 120 VDC
“S ¾” NPT conduit opening
NI N TCH
ANGLE°
• 0.4 Amp - 240 VDC
AR ATIO WI
CH
“W TU 1 S
CAST ALUMINUM
NG
“S TUATI WIT
OF
TCH ON
PO
MODEL VA-X
(epoxy coating available)
AND GASKET
WI
PO
14 Conveyorcomponents.com Conveyorcomponents.com 15
CONTROLS
MODEL
TPS FS
MODEL FS
TRIPPER MODEL
FLOW SWITCH FOR BULK MATERIAL
POSITION Control
FS Flow Switch
The Model FS Flow Switch is designed to produce a signal This versatile switch can be mounted on all types of conveyors
if the flow of material at any critical point is interrupted. This and feeders: in discharge openings of bins, bunkers, or
signal can then be used to correct the difficulty and/or warn hoppers; in angled and vertical chutes; or in discharge chutes
HEAVY DUTY LIMIT SWITCH EXCLUSIVE FEATURES
1. The housing is cast aluminum, with optional epoxy coating
the operator.
Several switches can be used, each one placed at critical
of any configuration. It is available with aluminum housing, and
in standard or explosion proof models. The paddle and shaft
The Model TA-TPS is a tripper position switch, which is a are both stainless steel.
available. The roller is a heavy duty white acetal material of points along the conveying system. A continuous flow of
heavy duty limit switch commonly used to aid in positioning of
3” diameter. material past the switch holds the paddle-shaft-counter- The Model FS is versatile enough to be used in a variety of
the “tripper” on a conveyor with multiple discharge points or
2. The unit is mounted on the conveyor by drilling weight assembly out of the actuated position. If flow stops, the applications; it can provide proof that material is actually
discharge chutes. The output contacts of the Model TA-TPS can
(3) 13/32” diameter holes. paddle is allowed to pivot and actuate the switch. flowing from a chute onto a conveyor belt, or it can be used to
control up to two separate circuits, one for machinery shutdown
and one for an alarm. The Model TA-TPS is relatively inexpensive Fully adjustable, the paddle and counterweight assemblies actuate a misting system to reduce dust only when material
3. General purpose (weatherproof) units and explosion proof
protection that provides benefit by saving time, money, and labor can be positioned at various points along the shaft and rotated is present.
units have (1) 3/4” NPT conduit opening.
associated with bulk material transfer. to any angular position. The shaft itself will adjust laterally.
4. SP/DT microswitches: Individually adjustable. Rated 20 Inside, the actuating cams can be rotated so that switch
AVAILABLE MODELS amp at 125, 250, or 480 VAC, 1/2 Amp 125 VDC; 1/4 Amp actuation will occur at pre-determined points.
250 VDC.
SHPG.
MODEL DESCRIPTION WT. 5. DP/DT microswitches: Individually adjustable. Rated 15 MODELS
LBS. amp at 125, 250 VAC. Microswitches
TA-2-TPS 2 Single Pole Double Throw (SP/DT) 6. The roller arm can move up to 90 degrees in either SHPG.
9 MODEL DESCRIPTION WT.
Microswitches* direction. Roller is spring loaded to automatically reset LBS
Cover Gasket
(Weatherproof units only)
*GENERAL PURPOSE NEMA TYPE 3S, 4, 4X, & 5 **EXPLOSION PROOF NEMA 7/9: Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1 &
“**EXPLOSION PROOF NEMA TYPE 7: Class I (Div. 1 & 2), Groups C & D; Type 9: Class II 2, Groups E, F & G
(Div. 1 & 2), Groups E, F & G” ***DUAL RATED NEMA TYPE Type 3S, 4, 4X, 5; Type 9: Class II (Div. 1 & 2), Groups
***DUAL RATED NEMA TYPE 3S, 4, 4X, 5; Type 9: Class II (Div. 1 & 2), Groups E, F & G E, F & G
16 Conveyorcomponents.com Conveyorcomponents.com 17
TOP VIEW OF OPEN ACTUATION
CONTROLS DB-100 UNIT MECHANISM
detected when an object or a piece of damaged belt hangs by comparison. Other than internally wired belts (tears are
below the belt’s surface and sweeps away one or both cables. electronically indicated). 6”
[153 mm]
As the cable is detached, it pulls a spring-loaded ball out of 5”
a socket, causing two microswitches to sound an alarm or to [127 mm]
shut down the conveyor. One end of each cable is permanently 3-7/16” 2-1/2” 1-1/2”
affixed to the bracket preventing the loss of the cable. [78 mm] [64 mm] [38 mm]
1” NPT
The Damaged Belt Detector operates using a spring-loaded [26 mm]
ball and socket connected to two plunger type microswitches. Conduit Opening
As an object hanging below the belt sweeps away the cable,
it pulls the ball connector from its socket (only 4 lbs. of force MODELS ACCESSORIES
required). When this happens, a spring-loaded shaft is released SHPG. SHPG.
causing the plungers of the two microswitches to ride down MODEL DESCRIPTION WT. MODEL DESCRIPTION WT.
cam surfaces machined on the shaft. This deactuates the LBS LBS
switches causing them to sound an alarm, turn on a warning 2 Single Pole Double Throw (SP/DT) DB-28 Cable End Fitting 1 oz.
light, or shut down the system. To reactivate the detectors, all DB-100 11
Microswitch, 4 lbs of pull force*
that’s required is to snap the ball connector and cable back into DB-29 Conduit Plug, 1” NPT 6 oz.
its socket. 2 Double Pole Double Throw (DP/DT)
DB-500 11 DB Ball & 10 foot cable assembly with
Microswitch, 4 lbs of pull force* 20340008 0.75
protective rubber boot
CROSS-SECTION OF CONVEYOR BELT 2 Single Pole Double Throw (SP/DT)
DBX-100 11 Housing: Aluminum (Standard). Epoxy coating available.
SHOWING INSTALLATION OF UNITS AND CABLE Microswitch, 4 lbs of pull force**
Conduit Opening: Two 1” NPT. Standard units and explosion proof models have two conduit
2 Double Pole Double Throw (DP/DT) openings.
DBX-500 11
Microswitch, 4 lbs of pull force** External Hardware: Stainless Steel
Switches: SP/DT microswitch. Rated 20 amp at 125, 250 or 480V AC, 1/2 Amp 125 VDC; 1/4
2 Single Pole Double Throw (SP/DT) Amp 250 VDC. Controls may be wired for single throw operation, either normally open or nor-
DBD-100 11 mally closed as required. DP/DT microswitches also available.
Microswitch, 4 lbs of pull force***
Max. 2” [51 mm] 2 Double Pole Double Throw (DP/DT) Standard unit “-100” is 4 lb.pull force. For optional 8 lb. or 16 lb. pull force retaining ring,
below conveyor belt DBD-500 11 add $ USD to price, and change “-100” to either “-108” or “-116”.
Microswitch, 4 lbs of pull force***
*GENERAL PURPOSE NEMA TYPE 4 & 4X
**EXPLOSION PROOF NEMA TYPE 7: Class I (Div. 1 & 2), Groups C & D; Type 9: Class II (Div. 1 & 2), Groups E, F & G”
18 ***DUAL RATED NEMA TYPE 4, 4X; Type 9: Class II (Div. 1 & 2), Groups E, F & G Conveyorcomponents.com 19
LEVEL
CONTROLS
CONSTRUCTION DETAILS
The Model CT Control Unit is enclosed in a rugged cast the end of the delay period, as well as upon failure of
6” [152 mm]
CT-105B 8
240 VAC* CT-200G Compact 6” probe with 25 feet of cable 5 • Probe ratings: 1.5 A @ 120VAC, 1.5mA
at 5 VDC
1 Double Pole Double Throw (DP/DT) relay for Compact 6” tilt probe with 25’ feet of 16-3
CT-105C 8 • Probe actuation angle: 15° from vertical
24 VAC/VDC* CT-200GC SO cable included. 3/4”NPT coupling weld- 5.5
CT-201GN: Non-Mercury heavy-duty 6-1/16”
1-1/4” [32 mm] ed to probe.
1 Double Pole Double Throw (DP/DT) relay for 13/32” [10 mm] probe; 9” [23 cm] long [154 mm]
CT-106 8 2” [51 mm] 1-3/8” [35 mm] MOUNTING
120 VAC*** HOLES Compact 6” tilt probe with 25’ feet of 16-3 CT-200GN: Non-Mercury compact probe; 9-1/16”
[230 mm]
TOP VIEW SIDE VIEW 2-3/4” [70 mm]
3 PLACES
CT-200GN SO cable included. Non-mercury (mercury 5.5 6” [15 cm] long
1 Double Pole Double Throw (DP/DT) relay for
CT-106B 8 MOUNTING PLAN free). • Probe signal voltage: 12 VDC when used
240 VAC*** CONTROL UNIT SPECIFICATIONS: with CCC controller
CT-105/CT-105B: NEMA Type 4, 4X Compact 6” tilt probe with 25’ feet of 16-3 • Probe ratings: 0.25 A max., 60 V max
1 Double Pole Double Throw (DP/DT) relay for 1” PIPE
CT-107 8 CT-106/CT-106B: NEMA Type 4, 4X CT-200GNC SO cable included. Non-mercury (mercury 5.5 • Probe actuation angle: 25° from vertical
120 VAC** 1-7/16” [33 mm]
NEMA Type 9 Class II, Groups E, F and G
free), 3/4” NPT coupling welded to probe. • Each steel Probe contains one SP/ST,
1 Double Pole Double Throw (DP/DT) relay for normally closed contact. Stainless steel,
CT-107B 8 CT-107/CT-107B: NEMA Type 7 Class I, Groups C and D Compact 6” tilt probe with 25’ feet of 16-3 paddles, epoxy coating and threaded
1-1/2” PIPE
240 VAC** CT-200GP 5.5 coupling options are available
NEMA Type 9 Class II, Groups E, F and G SO cable included. With welded-on paddle. 1-7/8” [48 mm]
*GENERAL PURPOSE NEMA TYPE 3, 4, 4X
**EXPLOSION PROOF NEMA TYPE 7: Class I (Div. 1 & 2), Groups C & D; Type 9: Class II (Div.1 & 2), • Input Supply Voltage: Standard 120 VAC @ 50/60 Hz; or available 240 VAC Standard 9” tilt probe with 25’ feet of 16-3
Groups E, F & G @ 50/60 Hz (add suffix B to Model number) CT-201GNC-3/4 SO cable included. Non-mercury (mercury 5.5
***DUAL RATED NEMA TYPE 3, 4, 4X; Type 9: Class II (Div. 1 & 2), Groups E, F & G
• Power Consumption: 10 Watts
free), 3/4” NPT coupling welded to probe.
COUPLING OPTIONS
• Probe Voltage Output: 12 VDC
• Output Relay: DP/DT; 5 Amps, 120 VAC Resistive; 5 Amps, 240 VAC Standard 9” tilt probe with 25’ feet of 16-3 CT-200GC CT-201GC - 3/4 CT-201GC
Resistive. CT-201GP 5.5 COMPACT PROBE PROBE PROBE
SO cable included. With welded-on paddle.
• Time Delay VR1: 0.1 to 35 Seconds. This adjustment will delay output
relay action.
2-5/8” [65 mm]
• Indicator Light: Normal (green): Illuminated when relay is energized.
• Indicator Light: Alarm (red): Illuminated when relay is de-energized.
MODEL CT - PROBES STANDARD 9” 3-3/8” [86 mm] 3-3/8” [86 mm]
Probe Models CT-200G and CT-201G are cULus Listed and CT-201GC SO cable included. 1-1/4” NPT coupling 8.5
intrinsically safe when connected with CT-300G Cable to Conveyor welded to probe. 3/4” NPT INTERNAL
THREAD
Components Company’s Control Units: Models CT-105, CT-106 and Standard 9” tilt probe with 25’ feet of 16-3
1-1/2” PIPE 1-1/2” PIPE
Ø1-5/16” [33 mm]
CT-107, and when used as intended and installed according to the
CT-201GC-3/4 SO cable included. 3/4” NPT coupling 8.5
manufacturer’s instructions. Any other use or installation is not cULus
MODEL CT-107 welded to probe.
Listed or intrinsically safe.
1-1/4” NPT
Standard 9” tilt probe with 25’ feet of 16-3 3/4” NPT INTERNAL
THREAD INTERNAL THREAD
CT-201GN SO cable included. Non-mercury (mercury 8.5
1-7/8” [48 mm] 1-15/16” [49 mm]
free)
ACCESSORIES Standard 9” tilt probe with 25’ feet of 16-3
CT-201GNC SO cable included. Non-mercury (mercury 8.5
MODEL CT - ACCESSORIES PROBE DIMENSIONS: with welded on paddle
free), 1-1/4” NPT coupling welded to probe.
CT-200GP/CT-200SGP CT-201GP/CT-201SGP 3 3/8” [86 mm]
SHPG. Standard 9” tilt probe with 25’ feet of 16-3 COMPACT PROBE STANDARD PROBE
WITH PADDLE WITH PADDLE
MODEL DESCRIPTION WT. CT-201GNC-3/4 SO cable included. Non-mercury (mercury 8.5
LBS free), 3/4” NPT coupling welded to probe.
2 5/8” [65 mm]
0.09 Standard 9” tilt probe with 25’ feet of 16-3
CT-300G 16-3 SO Probe Cable CT-201GP 8.5
lb./ft SO cable included. With welded-on paddle. 1 7/8” [48 mm]
9 1/16” [230 mm]
CT-400 Probe Mounting Bracket 0.75 10 1/16” [256 mm]
*For Non-Mercury Probe add option “N” to Model number. 1 7/16” [33 mm]
1 1/2” PIPE
CT-500 S-Hook 0.5 *For ¾ NPT or 1¼ NPT threaded coupling add option “C” to Model
6 1/16” [154 mm]
number. 1” PIPE
CT-600S Stainless Steel 4” Diameter Float Ball 0.5
*For Stainless Steel Probe add option “S” to Model number.
CT-700 Paddle Attachment Adapter 0.15 *For welded Paddle add option “P” to Model number.
4 3/4” [121 mm]
*For High Temperature use, add option “H” to Model number. 4 3/4” [121 mm]
CR-61 4 Vane Stainless Steel Paddle 0.4 4” 4” 13 1/16” [332 mm]
Tilt Probes are cULus Listed and Intrinsically Safe for Class I, Groups [101 mm] [101 mm]
CR-64 Rubber Flexible Paddle 0.4 A, B, C and D; Class II, Groups E, F and G Hazardous Locations when
CR-65 Stainless Steel Flexible Paddle 0.5 connected to Conveyor Components Company’s Control Units: Models
CT-105, CT-106 or CT-107 with CT-300G Cable and when used as intended 3” 3”
and installed according to manufacturer’s instructions. [76 mm] [76 mm]
22 Conveyorcomponents.com Conveyorcomponents.com 23
LEVEL
CONTROLS
CR
CONSTRUCTION FEATURES COMMON
TO ALL CR MODELS
1. Cover –
MODEL
Cast aluminum used for both NEMA Type 4, 4X
general purpose models and NEMA Type 7: Class I, Groups C
and D; NEMA Type 9: Class II, Groups E, F and G explosion proof
models. Optional epoxy coating is available.
2. Base – Cast aluminum standard with 1 ¼” NPT thread on
neck for installation in ½ coupling or standard mounting plate.
Conduit connection is ¾” NPT thread.
3. Motor –
ROTO-LEVEL CONTROL™
Power: 5 Watts, Frequency: 50/60 Hertz,
Speed: 1 RPM, Voltage: 120V or 240V. Other Voltages available.
4. Microswitches – SP/DT, rated at 20 amps. Unit can be
furnished with 1, 2 or 3 switches. All microswitches can be wired
for single throw operation, either normally open or normally
closed as required.
5. Sensitivity Adjustment – Spring tension is adjustable to
product density.
6. Time Delay Adjustment – Variable to prevent false signals.
7. Terminal Block – For CR motor voltage.
8. Clutch – Slips to prevent damage to motor gears.
9. Bearings – Sealed, permanently lubricated precision ball
bearings.
10. Shaft Seal – Dust and moisture-tight. Rated ½ micron dust
at 30 P.S.I.
11. Mounting Plate – 8” diameter with 1 ¼” welded pipe
coupling. Powder coated steel is standard. Stainless steel is
optional. Flexible to conform to curved bins.