Wrong answer summary
Correct answer:
It should automatically operate before the normal start sequence following an engine stopped period of more than 20 to 30 minutes when
manoeuvring.
Page 2/3
Wrong answer summary
Following replacement of a diesel alternator governor the machine is test run on load. It is found that as the load is gradually increased the
voltage and the frequency gradually fall to an unacceptable level. The governor is a mechanical hydraulic type. Select from the options
given the correct adjustment to make to correct the situation.
Selected answer (score 0):
The governor load limit should be increased.
Correct answer:
The governor droop should be reduced.