Professional Documents
Culture Documents
PIOM Catalogue
PIOM Catalogue
PIOM Catalogue
NPEFM;!QJPN.YQ
FNH FMFDUSPNZPHSBQIZ
FFH
TFQ
FMFDUSPFODFQIBMPHSBQIZ
TPNBUPTFOTPSZ!FWPLFE!QPUFOUJBM
16 32
NFQ NPUPS!FWPLFE!QPUFOUJBM
WFQ WJTVBM!FWPLFE!QPUFOUJBM
CBFQ CSBJOTUFN!BVEJUPSZ!FWPLFE!QPUFOUJBMT 9
By monitoring evoked potentials, EMG, TOF and other items, it provides surgeons with objective
evaluation indicators of central nerves, peripheral nerves, muscles and narcotics, provides
real-time feedback on the activity of nerves during surgery, and guides surgeons (e.g. neurosur-
gery, orthopedics, ENT, vascular surgery, thyroid surgery, thoracic surgery, etc.) on whether nerves
are touched during the progress of surgery or whether there is any damage to nerves and the site
of the damage.
TECHNICAL SPECIFICATIONS
AMPLIFIER
1 Number of channels: amplifier 16/ 32 channels.
*2 supports up to 32 channels of signal acquisition, with multiple channels integrated into
a single output port for connection to consumables, and supports quick connection of
acquisition electrodes.
3 Noise level: ≤ 2.0 μV p-p (0.2-200Hz)
*4 Input impedance: ≥ 3000M
5 With filtering function: high frequency filtering, 10HZ-7000HZ, low frequency filtering
0.1-500Hz, multi-position adjustable.
6 Common mode rejection ratio ≥ 120dB.prevent accidental vocal cord injury, and the elec-
trode placement ring is designed for improved muscle contact.
• Computer operating system software: Windows 10 Pro system, professional version of Office
software.
• Nerve monitoring software items: EEG, EMG, cortical localization, somatosensory evoked
potentials(SEP), motor evoked potentials(MEP), automatic vertebral pedicle stimulation program,
near nerve detection function, auditory evoked potentials(AEP), visual evoked potentials(VEP),
etc.
• Multiple inspections are carried out simultaneously on the same screen and can be switched
freely.
• Various monitoring modes for all modules can be edited and added according to the needs of the
operation, and can be saved as a template to facilitate future monitoring of similar operations.
• TOF test function.
• Noise analysis shielding software.
• With multiple data windows display: Real-time waveforms, trend graphs, data tables, video
images, event windows, etc., it can be displayed on the same screen, or can be viewed window
by window in separate screens.
• Report: Template function, can generate report with one click, user can edit and save it by them-
selves.
• Screen printing function: The monitoring waveform can be copied to the screen and automatical-
ly imported into the report or saved as a picture format.
ANTI-INTERFERENCE CAPABILITY
Anti-interference cable of integrated
Consumables greatly increase the resistance
of interference, avoiding interference with origi-
nal waveform, increasing the fidelity of the
waveform, avoiding misjudgment caused by
excessive interference.
SPIRAL ELECTRODE
Screw into patient's scalp, are firmly attached
and not easily dislodged.
Intraoperative stimulation current output, acting
on motor evoked potential monitoring.
SURFACE ELECTRODE
Patch type surface electrode, apply to the skin
surface of near nerves, e.g. median nerve,
tibial nerve.
Intraoperative stimulation current output, acting
on somatosensory evoked potential monitoring.