Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

IES ROAD REPORT

PHOTOMETRIC FILENAME : DIANA.LDT

DESCRIPTIVE INFORMATION (From Photometric File)

EULUMDAT
[MANUFAC]
[_EULUMDAT_ITYP] 1
[_EULUMDAT_HDIST] 0
[_EULUMD_VDIST] 0
[TEST] ZEM037
[LUMINAIRE] LDF3150C
[LUMCAT] 150lm 1h IP42
[_EULUM_FILENAME] DIANA
[ISSUEDATE] 21/04/2015\Carlos Sierra
[_EULUM_AREALENGTH] 300
[_EULUM_AREAWIDTH] 100
[_EULUM_C0_LUM] 300
[_EULUM_C90_LUM] 80
[_EULUM_C180_LUM] 900
[_EULUM_C270_LUM] 80
[_EULUM_DOWN_FLUX] 995
[_EULUM_EFFICIENCY] 997
[_EULUM_CONV] 10
[_EULUM_TILT] 0.0
[_EULUM_LAMP_1_NUM] 1
[_EULUM_LAMP_1_TYPE] LED
[_EULUM_LAMP_1_FLUX] 150
[_EULUM_LAMP_1_COLOR] 4000
[_EULUM_LAMP_1_CRG] 80
[_EULUM_LAMP_1_WATTS] 4
[LAMP] LED
[_EULUM_DR_0] 0
[_EULUM_DR_1] 0
[_EULUM_DR_2] 0
[_EULUM_DR_3] 0
[_EULUM_DR_4] 0
[_EULUM_DR_5] 0
[_EULUM_DR_6] 0
[_EULUM_DR_7] 0
[_EULUM_DR_8] 0
[_EULUM_DR_9] 0

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 1
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

CHARACTERISTICS

IES Classification Type VS


Longitudinal Classification Very Short
Lumens Per Lamp 150 (1 lamp)
Total Lamp Lumens 150
Luminaire Lumens 14964
Downward Total Efficiency 9953 %
Total Luminaire Efficiency 9976 %
Luminaire Efficacy Rating (LER) 3740
Total Luminaire Watts 4
Ballast Factor 1.00
Upward Waste Light Ratio 0.00
Maximum Candela 4870
Maximum Candela Angle 90H 5V
Maximum Candela (<90 Degrees Vertical) 4870
Maximum Candela Angle (<90 Degrees Vertical) 90H 5V
Maximum Candela At 90 Degrees Vertical 160 (106.7% Lamp Lumens)
Maximum Candela from 80 to <90 Degrees Vertical 780 (520.0% Lamp Lumens)
Cutoff Classification (deprecated) Non-Cutoff

LUMINAIRE CLASSIFICATION SYSTEM (LCS)

Lumens % Lamp % Luminaire


FL - Front-Low (0-30) 1811.1 1207.4 12.1
FM - Front-Medium (30-60) 3642.5 2428.3 24.3
FH - Front-High (60-80) 1819.7 1213.1 12.2
FVH - Front-Very High (80-90) 191.6 127.7 1.3
BL - Back-Low (0-30) 1811.1 1207.4 12.1
BM - Back-Medium (30-60) 3642.5 2428.3 24.3
BH - Back-High (60-80) 1819.7 1213.1 12.2
BVH - Back-Very High (80-90) 191.6 127.7 1.3
UL - Uplight-Low (90-100) 33.7 22.5 0.2
UH - Uplight-High (100-180) 0.0 0.0 0.0

Total 14959.0 9972.0 100.0

BUG Rating B3-U2-G2

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 2
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

CANDELA TABULATION

Vert. Horizontal Angles


Angles
90 105 120 135 150 165 180 195 210 225
0 4800 4800 4800 4800 4800 4800 4800 4800 4800 4800
5 4870 4800 4660 4530 4460 4440 4440 4440 4460 4530
10 4800 4620 4300 4140 3980 3980 4070 3980 3980 4140
15 4670 4410 4050 4170 4330 4380 4410 4380 4330 4170
20 4510 4190 3870 4240 4670 4770 4750 4770 4670 4240
25 4390 4160 3900 4160 4440 4490 4510 4490 4440 4160
30 4250 4120 3980 4050 4120 4150 4170 4150 4120 4050
35 4000 3930 3840 3810 3790 3710 3650 3710 3790 3810
40 3730 3710 3670 3560 3450 3280 3150 3280 3450 3560
45 3350 3330 3300 3220 3140 3140 3140 3140 3140 3220
50 2920 2930 2910 2870 2840 3010 3190 3010 2840 2870
55 2150 2310 2490 2620 2760 3100 3400 3100 2760 2620
60 1370 1700 2070 2390 2710 3170 3560 3170 2710 2390
65 880 1260 1690 2350 3000 3130 3240 3130 3000 2350
70 460 860 1330 2280 3120 2950 2760 2950 3120 2280
75 300 660 1050 1530 1980 1870 1750 1870 1980 1530
80 180 470 780 730 760 770 760 770 760 730
85 90 240 400 390 390 360 330 360 390 390
90 10 30 50 100 160 110 50 110 160 100
95 0 0 0 30 70 30 0 30 70 30
100 0 0 0 0 0 0 0 0 0 0
105 0 0 0 0 0 0 0 0 0 0
110 0 0 0 0 0 0 0 0 0 0
115 0 0 0 0 0 0 0 0 0 0
120 0 0 0 0 0 0 0 0 0 0
125 0 0 0 0 0 0 0 0 0 0
130 0 0 0 0 0 0 0 0 0 0
135 0 0 0 0 0 0 0 0 0 0
140 0 0 0 0 0 0 0 0 0 0
145 0 0 0 0 0 0 0 0 0 0
150 0 0 0 0 0 0 0 0 0 0
155 0 0 0 0 0 0 0 0 0 0
160 0 0 0 0 0 0 0 0 0 0
165 0 0 0 0 0 0 0 0 0 0
170 0 0 0 0 0 0 0 0 0 0
175 0 0 0 0 0 0 0 0 0 0
180 0 0 0 0 0 0 0 0 0 0

Vert. Horizontal Angles


Angles
240 255 270
0 4800 4800 4800
5 4660 4800 4870
10 4300 4620 4800
15 4050 4410 4670
20 3870 4190 4510
25 3900 4160 4390
30 3980 4120 4250
35 3840 3930 4000
40 3670 3710 3730
45 3300 3330 3350
50 2910 2930 2920
55 2490 2310 2150
60 2070 1700 1370
65 1690 1260 880
70 1330 860 460
75 1050 660 300

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 3
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

CANDELA TABULATION - (Cont.)

80 780 470 180


85 400 240 90
90 50 30 10
95 0 0 0
100 0 0 0
105 0 0 0
110 0 0 0
115 0 0 0
120 0 0 0
125 0 0 0
130 0 0 0
135 0 0 0
140 0 0 0
145 0 0 0
150 0 0 0
155 0 0 0
160 0 0 0
165 0 0 0
170 0 0 0
175 0 0 0
180 0 0 0

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 4
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

COEFFICIENTS OF UTILIZATION

1.0

0.9

0.8

0.7

0.6
Coeff.
Of
0.5
Utiliz.

0.4

0.3

0.2

0.1

0.0 0 1 2 3 4 5
Street Width / Mounting Height

FLUX DISTRIBUTION
Percent
Lumens Of Lamp

Downward Street Side 7464.9 4976.6


Downward House Side 7464.9 4976.6
Downward Total 14928.0 9952.0

Upward Street Side 16.9 11.2


Upward House Side 16.9 11.2
Upward Total 32.0 21.3

Total Flux 14960.0 9973.3

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 5
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

POLAR GRAPH

4870
2

3652

2435

1217

Maximum Candela = 4870 Located At Horizontal Angle = 90, Vertical Angle = 5


# 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.)

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 6
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINANCE

3
.1 .2 .5 1

2
2

1 10

20
House
Side
0
Street
Side

1.75
2

2.75
3

5
0 1 2 2.25 3 3.75 4 5 6 7
Distance In Units Of Mounting Height
Values Based On 10 Foot Mounting Height
1/2 Maximum Candela Trace Shown As Dashed Curve
(+) = Maximum Candela Point

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 7
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
IES ROAD REPORT
PHOTOMETRIC FILENAME : DIANA.LDT

LUMINAIRE CLASSIFICATION SYSTEM (LCS) GRAPH

Luminaire Lumens Uplight


3642

2731

1821

100 910 100

90 90

80 80

60 60

30 30

Back 0 Front

Luminaire Lumens:
Front: Low=1811.1, Medium=3642.5, High=1819.7, Very High=191.6
Back: Low=1811.1, Medium=3642.5, High=1819.7, Very High=191.6
Uplight: Low=33.7, High=0.0

BUG Rating : B3-U2-G2

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 8
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

You might also like