METHOD STATEMENT

FOR DOUBLE REGULATING VALVE

Obje ctive

The objective of this method statement is to provide general guidelines for calibrating
double regulating valve at customer’s premises.

Scope

Scope of this method statement covers the following topics.


 Preparation
 Test
 Test report information

Reference Procedure

 Phoenix Calibration Technical Manual- PCW-P02:2021.

Master Equipment

 Calibrated pressure gauge.

Preparation prior to Test

 Reach the calibration location accompanied by the site engineer or In-charge.

 Check the environment suitability to execute the calibration process.

 Get the valve location details from site engineer / In-charge.

Test

 Check the regulating valve and flow line physical condition and make
sure it is free from defects.
 Note the valve details like make, model, serial no., location, ID No., etc.
on the relevant worksheet.

Page. 1 of 2
 Connect the pressure gauge to first flow line.
 Exercise the regulator with open position of 25%, 50%, 75% and 100%
range of its maximum rotation limit.
 Observe the pressure gauge reading on the flow line.
 Note down the pressure readings at each step of valve position on its
relevant work sheet.
 Connect the pressure gauge to second flow line and repeat the steps as
mentioned above.
 Complete the test and paste the identification sticker on the appropriate
part of the valve.

Test Certificate Information


 Test Certificate Number
 Work order number
 Procedure number
 Valve details
 Reference instrument details
 Valve location, ID details,
 Test date & Recommended due date
 Pressure Readings Vs valve positions
 Calibration engineer name & signature
 Approving authority name & signature
 Stamp of certification

****END OF METHOD STATEMENT****