Sl no Test Items Test Condition Specification/ Acceptance Criteria Sample No. Remarks
CONFORMATION:-
1 Fan Image Provide the fan image from that all Specific to model 1
external parts must be visible
3 Height of fans As per caluse 8.1 of IS 1169- 1969 As per clause 8.1 of IS 1169 - 1969 1 to 10
4 Marking As per caluse 15.1 of IS 1169- 1969 As per clause 8.1 of IS 1169 - 1969 1 to 10
5 Motor specification Specify the motor type, pole, stack height, material of Specific to model 1 to 10
lamination & capacitor specification of motor.
8 Rotor complete height Specify the full height of rotor Specific to model 1 to 10
9 Skew angle of rotor Specify the skew angle of rotor Specific to model 1 to 10
10 Blade specification Specify the blade details Specify the blade details 1 to 10
PERFORMANCE:-
13 No load power & current Operate the fan in no load condition Specific to model 1 to 10 Take the reading after
@ 230V (H/M/L) 5 mins of running.
14 Lock rotor power & current Operate the fan at lock rotor condition Specific to model 1 to 10 Take the reading after
@ 230V (H/M/L) 5 mins of running.
15 Full load power & current Operate the fan in full load condition Specific to model 1 to 10 Take the reading after
@ 245V (H/M/L) 5 mins of running.
20 Speed at 180V (H/M/L) Operate the fan at 180V, 50hz Specific to model 1 to 10 Take the reading after
and check the RPM(H/M/L) 5 mins of running.
21 Low voltage stability Operate the fan with oscillation & blade load Specific to model 1 to 10
at low speed
22 Motor winding resistancce Specify the main & aux winding Specific to model 1 to 10
data with wire gauge.
31 Cord grip test As per clause 16.5 of IS 1169 - 1969 As per clause 16.5 of IS 1169 - 1969 7
Mechanical endurance
32 test ( for regulators only) As per clause 16.6 of IS 1169 - 1969 As per clause 16.6 of IS 1169 - 1969 1,2
33 Power factor test As per clause 16.7 of IS 1169 - 1969 As per clause 16.7 of IS 1169 - 1969 01 to 10
should not be less than 0.9
34 Leakage current Check current between common As per clause 16.8 of IS 1169 - 1969 01 to 10
wire and motor body
35 High voltage test As per clause 16.9 of IS 1169- 1969 As per clause 16.9 of IS 1169 - 1969 3,4,5
36 Earting continuity Check the continuity between earthing therminal As per clause 16.10 of IS 1169 - 1969 3,4,5
and motor body at 25 amp and check voltage.
37 Flash test As per clause 16.13 of IS 1169 - 1969 As per clause 16.13 of IS 1169 - 1969 3,4,5
Apply 500V DC between common wire &
38 Insulation resistance motor body As per clause 16.14 of IS 1169 - 1969 3,4,5
39 Protection against direct contact As per clause 6.14 of IS 1169 - 1969 As per clause 6.14 of IS 1169 - 1969 3,4,5
41 Protective measures As per clause 6.13 of IS 1169 - 1969 As per clause 6.13 of IS 1169 - 1969 3,4,5
Operation the at high speed and check the noise due Fan to be put on continous
43 Noise during fan operation to plastic parts, tik- tik, noise, distance noise etc. No abnormal noise 1 to 10 running at laest for 20 days.
STRENGTH/ RELAIBILITY
45 Strength test of blade (8 nos) Lock the blade in motor & switch on / off No brekage in blade. 6
the fan for 168 hrs.
Intermittent operate of the fan at line voltage at 50K cycles at main supply ( 20 sec On &
47 On / Off cycle test at main supply high speed Off till complete fan stop) 8
Unbalance blade of 5 gm and run fan at line Check the motor of the fan with fresh Perform all performance
48 Unbalance test voltage for 15 days blade for power & speed 9 test before and after the drop
test
49 Hot chamber test Run the fan at full speed at rated voltage at 60°C No abnormal noise/ vibration 7
for 10 days / malfunction
50 Oscillating and tilting mech Put 3 kg weight on guard and oprate It sound not tilt it by own 6
fan oscillation for 3 hours
51 Inverter test Run tha fan on square wave inverter for 24 hrs No abnormalities 5
54 Paint reliability(Liquid / powder) Adhesion test & salt spray test As per BEL standard 6