28/06/2023 09:20 1 of 3
Status Index Description Value Drive Value Default Range Units
Restart Power?
d081.7 Fault Monitor 1 (power-o 863 --- 0 0 to 1193028 Hour(s)
d082.1 Fault Monitor 2 (factor) 1: Over-current --- 0 0 to 255
d082.2 Fault Monitor 2 (inverter 3: Constant-spe --- 0 0 to 255
d082.3 Fault Monitor 2 (frequenc 37,79 --- 0,00 0,00 to 400,0 Hz
d082.4 Fault Monitor 2 (current) 3,76 --- 0,00 0,00 to 655,3 A
d082.5 Fault Monitor 2 (voltage) 524,3 --- 0,0 0,0 to 1000,0 V
d082.6 Fault Monitor 2 (running t 208 --- 0 0 to 1193028 Hour(s)
d082.7 Fault Monitor 2 (power-o 738 --- 0 0 to 1193028 Hour(s)
d083.1 Fault Monitor 3 (factor) 1: Over-current --- 0 0 to 255
d083.2 Fault Monitor 3 (inverter 3: Constant-spe --- 0 0 to 255
d083.3 Fault Monitor 3 (frequenc 46,51 --- 0,00 0,00 to 400,0 Hz
d083.4 Fault Monitor 3 (current) 3,78 --- 0,00 0,00 to 655,3 A
d083.5 Fault Monitor 3 (voltage) 514,0 --- 0,0 0,0 to 1000,0 V
d083.6 Fault Monitor 3 (running t 208 --- 0 0 to 1193028 Hour(s)
d083.7 Fault Monitor 3 (power-o 738 --- 0 0 to 1193028 Hour(s)
d084.1 Fault Monitor 4 (factor) 1: Over-current --- 0 0 to 255
d084.2 Fault Monitor 4 (inverter 3: Constant-spe --- 0 0 to 255
d084.3 Fault Monitor 4 (frequenc 46,51 --- 0,00 0,00 to 400,0 Hz
d084.4 Fault Monitor 4 (current) 3,64 --- 0,00 0,00 to 655,3 A
d084.5 Fault Monitor 4 (voltage) 524,2 --- 0,0 0,0 to 1000,0 V
d084.6 Fault Monitor 4 (running t 208 --- 0 0 to 1193028 Hour(s)
d084.7 Fault Monitor 4 (power-o 738 --- 0 0 to 1193028 Hour(s)
d085.1 Fault Monitor 5 (factor) 1: Over-current --- 0 0 to 255
d085.2 Fault Monitor 5 (inverter 3: Constant-spe --- 0 0 to 255
d085.3 Fault Monitor 5 (frequenc 46,51 --- 0,00 0,00 to 400,0 Hz
d085.4 Fault Monitor 5 (current) 3,69 --- 0,00 0,00 to 655,3 A
d085.5 Fault Monitor 5 (voltage) 524,4 --- 0,0 0,0 to 1000,0 V
d085.6 Fault Monitor 5 (running t 208 --- 0 0 to 1193028 Hour(s)
d085.7 Fault Monitor 5 (power-o 738 --- 0 0 to 1193028 Hour(s)
d086.1 Fault Monitor 6 (factor) 1: Over-current --- 0 0 to 255
d086.2 Fault Monitor 6 (inverter 3: Constant-spe --- 0 0 to 255
d086.3 Fault Monitor 6 (frequenc 37,79 --- 0,00 0,00 to 400,0 Hz
d086.4 Fault Monitor 6 (current) 3,73 --- 0,00 0,00 to 655,3 A
d086.5 Fault Monitor 6 (voltage) 513,2 --- 0,0 0,0 to 1000,0 V
d086.6 Fault Monitor 6 (running t 208 --- 0 0 to 1193028 Hour(s)
d086.7 Fault Monitor 6 (power-o 738 --- 0 0 to 1193028 Hour(s)
F001 Output Frequency Settin 0,00 --- 6,00 0,00 to 200,0 Hz
F002 1st Acceleration Time 1 8,00 --- 10,00 0,00 to 3600, Sec
F003 1st Deceleration Time 1 5,00 --- 10,00 0,00 to 3600, Sec
H104 PM Motor Poles Setting 3: 8 poles --- 1 0 to 23 Pole(s)
H105 PM Motor Rated Current 0,78 --- 1,60 0,00 to 1,80 A
28/06/2023 09:20 2 of 3
Status Index Description Value Drive Value Default Range Units
Restart Power?
H106 PM Motor Constant R 14,530 --- 4,408 0,001 to 65,5 Ohm(s)
H107 PM Motor Constant Ld 81,90 --- 40,70 0,01 to 655,3 mH
H108 PM Motor Constant Lq 94,10 --- 44,40 0,01 to 655,3 mH
H109 PM Motor Constant Ke 0,1619 --- 0,1709 0,0001 to 6,5 Vpeak/(r
H110 PM Motor Constant J 0,075 --- 0,001 0,001 to 999 Kgm^2
H116 PM Speed Response 165 --- 100 1 to 1000
H117 PM Starting Current 45,00 --- 70,00 20,00 to 100, %
H118 PM Starting Time 0,50 --- 1,00 0,01 to 60,00 Sec
H119 PM Stabilization Constan 81 --- 100 0 to 120 %
H121 PM Minimum Frequency 10,0 --- 8,0 0,0 to 25,5 %
H122 PM No-Load Current 15,00 --- 10,00 0,00 to 100,0 %
P055 Pulse Train Frequency S 1,5 --- 25,0 1,0 to 32,0 kHz
28/06/2023 09:20 3 of 3