Download as pdf
Download as pdf
You are on page 1of 6
DPM We / UE / Bh series DEW POINT & HUMIDITY METER ce "HREARt & REST & RET RS RETIRE RRR ARAT : - 69°C OR RRAT ER / RE" =a @DEW POINT & TEMPERATURE SETTABLE @LOWEST DEW POINT DISPLAY : - 69 °C @DEW POINT & HUMIDITY & TEMPERATURE METER ALL IN ONE on. 8, TO DISPLAY DP/TEMP OR HUM/TEMP SELECTABLE XR / ime" MSPECIFICATION/}i FS MODEL @3e DPM-1 DPM-2 DPM-1-S DPM-2-S OUTLINE SHE 48x96 96x48 48x96 96x48 POWER SUPPLY [/FS@AB 90~265 VAC, 50/60 Hz / 5 VA MAX. SENSOR 1 if K, JOR PT TYPE SENSOR 2 8815 r83 RELATIVE HUMIDITY SENSOR <0.800VDC ~3.800VDC> TEMP OUTPUT iiSi2A/R6tH RELAY 1c DP/RH OUTPUT #&3i/RE@SIML RELAY 1a <5A/250VAC> CONTROL METHOD #2417534 ON / OFF DP/RH TRANSMITTER #225 S SiS NON 4~20mA RANGE OF HUMIDITY SRERAT GH 0.0% ~ 99.9% RANGE OF DEW POINT SaRiSAT Oa ~ 69°C ~ 20.0 RANGE OF TEMPERATURE iS/ERA760i81 O'c ~ 999°C ‘ACCURACY OF DISPLAY SAi78 EE + (0.1% OF FS. + 1 DIGIT) SETTING RANGE 80528008 +99 TEMPERATURE SHIFT 3215iE 49.99 HUMIDITY SHIFT sREEVEIE 49.99 RESPONSE TIME R65 f 1SEC MEMORY METHOD f2t753t EEPROM INSULATION RESISTANCE #482805 OVER 50MQ DIELECTRIC STRENGTH Mia OVER 2.5 KV/ 1 MINUTE. OPERATING CIRCUMSTANCE (FIR, 20°C ~ 75°C: 35%~85% RH EMC STANDARD ESD : 8 KVAIR CHARGE < LEVEL 3>/EN-61000-4-2 BURST TEST : 2 KV/ EN61000-4-4 WARE / Se / SeBhat cE DEW POINT & HUMIDITY METER oe SELECTING OF MONITOR (i 7 32 F%) sravoror/7e|/ Od | “yaqtromre:t© DP/TC Rin 00 1 tert RH%/CETC DISPLAY OF RH/TC oor Ca RH/TC Si D0c | 2>-AFTER PRESSING THE “a'KEY 3SEC.MAY SHIFT THE VALUE OF RHBY"a" or"¥" or “SET"KEY SrA‘ + Teaor W "or SET RISA BRE © S> AFTER PRESSING THE “W"KEY 3SEC.MAY SHIFT THE VALUE OF TCBY"A' or" ¥" or SET" KEY HRATSBIE + Tektaor" Wor SET RSA A © PRESS” "KEY 1d DEW POINT /V: SV OF DP::RH / v:SVOFRH Gs ORR: RRR AR |v 2>PRESS THE'SET'a'or"W"KEY TO CHANGE THE SETTING VALUE OF "DP" PR'SET’ "Aor WALA M MMA EEE A + ‘> Vd>SVd/ R2 OFF : PVAS(PVG-HYS) | R2ON [pispayoror/sv|| OOd DP/SV Bt [990 PRESS" 4 "KEY tbe: Ter svorte co: RRA vy: Ee mK | 80. | PRESS THE'SET" aor W'KEY TO CHANGE THE SETTING VALUE OF "TC" AB"SET" "a'or" WS BON ih SAT EL © S>PVo>8VCIRI OFF: Pes(PVCHYS) RY ON DISPLAY OF TC /SV Tc S S by PRESS" €"KEY HOWTO SHIFT THE DISPLAY VALUE OF RELATIVE HUMIDITY (41 {0 (22 TF 2 EE Bi A ) THE DISPLAY VALUE OF RELATIVE HUMIDITY MAYBE DIFFERENT FROM THE ACTUAL VALUE, PLEASE SELECT THE RH/TC MONITOR STATUS, AFTER PRESSING THE" A" KEY 3SEC,__ MAY SHIFT THE VALUE OF RELATIVE VALUE BY"A’,"¥" OR "SET" KEY AAREGAENE RETR ERE : TLE RE RE SRRER » (RABI BILUG' A" "VW" SySET SNEAUASRE IG ° DPM iB / Me / wet ce€ Series _ TEMPERATURE & DEW POINT & HUMIDITY METER m SETTING OF PARAMETER / 3 82442 STATUS ‘SYMBOL REMARKS 1AFTER PRESSING" "5 SEC.MAY ENTER TO THE SETTING OF PARAMETER eC ROMe TEASRRE STATUS OF MONITOR || 00.0d ARE | 00.0¢ PRESS"-4 "KEY | KEYSSEC 1 REGORTVaEEESe || Hyg | 1?PVczSVcIRI OFF, PVos(SVe-HYS)/R1 ON — 2>PVd= SVd/ R2 OFF, PVd=(SVd-HYS) / R2 ON BEBE 00.0 pRess‘ser | KEY aoe EAE ee SeLEGTIIG ETE WEL ink) PINPUTTYPE : K/J/PTSELECTABLE = SRM K/S/PT OR GRRE ¥ press‘ser | KEY | Spee Grae |" SENS GUN Unk | UNIT: °C OR'F SELECTABLE is Flea SS aSGE BERG CORT ORR ¢ | | a a a ter: RH TRANSMITTER : d : DEW POINT. | TRANSMITTER SETTING tr | ee LK =" 1 transMiTTER | AeaRR RH FUME ds RRA HS PRESS"SeT" Kev BRE / MAE / se Bhat DEW POINT & HUMIDITY METER DPM series MSETTING OF TRASNMITTER / {838 23 7E STATUS OF NORMAL es | 80 PRESS "SET yKEY3SEC E SETTING OF LOCK Lee HERE raaaa eer PSY HILIMT OF TRANSMITTER SiH MAERRE 90 PRESS" SET 4 KEY LOUMIT OF TRANSMITTER] Sut eateme | 0 PRESS™ SET | KEY LOUMIT OF DP PL RET RM “st HCONNECTION DIAGRAM / #23 REMARKS 1d: DEW POINT; cor F : TEMPERATURE ds BEBE corr: 8 1> 0: ALL SETTING ARE UNLOCK SV SETTABLE 2: SV SETTABLE ALLLOCK 41> THE SLH IS CONVERTED TO"20.0" mA, “"SLH"#8 0"20.0mA" 41> THE "SLL" IS CONVERTED TO "4.0" mA “SLL“#9A"4.0mA" DPM-1 DPM-2 jum. Sensor] @ [Hum.Sensor atti ||| ooh a | |S =o [pv tw [ov] sav] — Tc | Power | sensor | |& Te Power | TC Sensor SatieEeet & = 7G + pa a See i ar Lo! Se M OUTLINE DIMENSION 4 J +t Since Mul Justaposed eer ET DPM-1-1 DPM-2-1 HS YE RH a ce series HUMIDITY SENSOR @LINEAR VOLTAGE OUTPUT vs %RH MAREN RRR RIG @ HIGH ACCURACY : +2.0% RH BYE + +2.0%RH FAST RESPONSE TIME : 15SEC (RMBES + 15SEC @STABLE & LOW DRIFT PERFORMANCE Reis} BRE & RMSE @CHEMICALLY RESISTANCE niteae MODEL Be HS-1 HS-2 OPERATING VOLTAGE LiF 4.0V DC~ 5.5VDC (CURRENT CONSUMPTION Ree 200 w ATYPICAL OPERATING HUMIDITY RANGE 358508) 0 ~ 100% RH, NON-CONDENSING RH ACCURACY RHE 2.0% RH RH LINEARITY Rt +0.5% RH RH HYSTERESIS B= + 1.2% RH OF FS RH REPEATABILITY matt £0.5% RH RESPONSE TIME meg 15 SEC IN SLOWLY MOVINGAIR @ 25°C RH STABILITY ett £ 1.0% RH TYPICAL AT 50% RH IN 5 YEARS CONNECTION METHOD heeost M12 CONNECTOR OPERATING TEMPERATURE {FIRE - 40°C ~85C COMMENT SER | LIGHT SENSITIVE, SHIELDED FROM BRIGHT LIGHT OR BE ae cE HUMIDITY SENSOR MCONNECTION DIAGRAM elm HOUTLINE DIMENSION HS-1 HS series Bev Box ROM Bl eB ow

You might also like