Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

CONSTRUCTION COST ESTIMATE

Pay Item Unit Price Estimated


Estimated
(Ref. to Section Description Unit Including VAT Amount
Quantity
01150) (SR.) (SR.)

I. FIXED PRICE ITEMS (NOT USED)

II. UNIT PRICE ITEMS

fiyiuy

SW-34.01.04. Construction of Bridge at Ramp-3


SW-34.01.04-01. Lean concrete M³ 16
SW-34.01.04-02. Cast in-situ reinforced concrete (approach slab) M³ 48
SW-34.01.04-03. Cast in-situ prestressed reinforced concrete M³ 1,181
SW-34.01.04-04. Reinforcement bars for Prestressed Girder incl Diaphragms Ton 320
SW-34.01.04-05. Bearing pad EA 6
SW-34.01.04-06. Expansion joint LM 32
SW-34.01.04-07. Waterproofing on substructure exposed to soils SM
SW-34.01.04-08. Waterproofing membrane SM 1,003
SW-34.01.04-09. Asphalt, 50 mm thick SM 1,003
SW-34.01.04-10. Bridge parapet New Jersey barrier LM 143
SW-34.01.04-11. 200 mm thick Perforated layer, incl. weep hole PVC pipes SM
SW-34.01.04-12. 100 mm diameter uPVC scupper drainage pipe with heavy duty road gully SET 2
and gratings
Tendons (0.6 " dia) Prestressed steel Wires in Prestress Multi cell Box KG 46,359
Girder

SUB-TOTAL (CONSTRUCTION OF BRIDGE AT RAMP-3) - SR 0

CCE - 1 Contract No. PIC R-T-7552


CONSTRUCTION COST ESTIMATE

D130: Reinforcement bars for Prestressed Girders only. Please provide the quantities in Ton.

D133: Kindly provide and include the Waterproofing on substructure exposed to soils.
Please provide the quantities in square meter.

D137: Perforated layers are requirements by RC.


It is actually a clean stone gravels with 200mm thick besides of both Abutment Retaining Walls or Footings, including weep hole PVC pipes.
Please provide the quantities in square meter.

D138: uPVC Scupper Drainage pipe with heavy duty road gully and gratings are requirements by RC.
Please provide the quantities in Number/Set.

CCE - 2 Contract No. PIC R-T-7552


RAMP -3

L W H Quantity
Description Unit No. Quantity
(m) (m) (m) % INC.

Concrete Class A1 (3000 psi) Approach Slab CM 14.11 A= 1.53 2.00 43.20 48

Reinforcement @ (kg/m )3
48

160 Ton 6.91

Lean Concrete CM 14.11 5.10 0.1 2 14 16

16

Concrete Class A3 (50MPa) (RCC BOX GIRDER)

End portion Box Section CM 3.56 A = 16.16 2 114.99 126

CM 6.00 A = 13.99 2 167.85 185

CM 35.50 A = 11.82 1 419.57 462

Total Length = 54.62 702.42 773

Reinforcement @ (kg/m )3

350 Ton 246 246

Diaphragm at Mid CM 11.61 0.5 2.10 1 12.19 13

Diaphragm at End CM 11.61 3.56 2.10 2 173.54 191


204
185.73
409

Reinforcement @ (kg/m3)

400 Ton 74 74

Concrete Class A3(4000psi) N.J.Barrier CM 64.62 A= 0.34 0 0.00 142.17

M 64.62 2 129.24 143

Reinforcement @ (kg/m )3

100 Ton -

Reinforcement as per AASHTO M-31 Grade-60 Ton 470


471
Elastomeric Bearing Pads (According to size & Cubic
50 65 8.7 20 565500 622,050
thickness) - Imported (European/American Make Centimeter

622050

50 mm Expansion Joint -Nosing Type with Two


Aluminium Alloy Section and Elastomeric Profile LM 14.1 2 28.22 31
Imported (European/American Make)
32
1
Galvanized Iron Drain pipe, 100mm dia Each 25.8488 25.8488 28.43368
29

Asphlt 50mm thick SM 64.62 14.11 911.82 1003

1003

Tendons (0.6 " dia) Prestressed steel Wires in


Prestress Multi cell Box Girder 773
Reinforcement @ (kg/m3)
60.00 KG 46,359

You might also like