Professional Documents
Culture Documents
2023-05-27 Statik Wall 6.3 M Peri Vario High Security Building
2023-05-27 Statik Wall 6.3 M Peri Vario High Security Building
I. TECHNICAL DATA
b 1 cm
Ax 23 cm2
Ix 372 cm4
Wx 74 cm3
Sx 43.38 cm3
Δ max L/360
E 2,100,000 kg/cm2
σ allowable 1,437 kg/cm2
τ allowable 958 kg/cm2
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 3 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
III. LOAD
Dead Load
There are 2 types of dead load :
a. Concrete Load
Concrete load used is 2,550 kg/m3, based on DIN 18218:2010.
b. Selfweight material
Selfweight material is weight materials used for formwork
Material Spesification
a. For timber material used timber class II based on Peraturan Konstruksi Kayu Indonesia (PKKI) 1961
b. For steel material used Steel ST37 with yield strength 2400 kg/cm2 and tensile strength 1600 kg/cm2 based
on Peraturan Perencanaan Bangunan Baja Indonesia 1984 (PPBBI 1984)
c. For Girder GT24 based on guidelines Peri Standard Design Tables 2015
d. For Tie Rod material used steel type S45C with yield strength 4996.61 kg/cm2 and tensile strength 6995.25
kg/cm2.
e. Material RSS & Kicker AV to be ignored for the calculation because this material is used for verticality,
not receives the load from concrete,all load from concrete just recevied to Tie rod DW 15.
Load Combination
a. Load combination include Dead Load and Live Load with safety factor 1.67 (for allowable yield and tensile
strength).Method used in analysis is Allowable Stress Design (ASD) Method (SNI 1729-2020)
b. Load Combination = 1 DL + 1 LL
Load Assumption for Horizontal Load
Concrete Density = 2,550 kg/m3
= 0.7 m/hour
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 4 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
785𝑅
CCpmax = CcCw [7.2 + 𝑇+17.8
]
Cc = Chemistry coefficient
CW = Unit weight coefficient
R = Rate of placement, ft/h (m/h)
T = Temperature of concrete at time of placement, °F (°C)
R = 0.7 m/h
T = 25 0C
h: 1.06 m
Lateral Pressure of Concrete :
785𝑅
CCpmax = CcCw [7.2 + ]
𝑇+17.8
Hs = Ccpmax / w
= 2,695 kg/m2 / 2,550 kg/m3
= 1.06 m
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 6 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
Load Calculation :
q1 = 2,695 kg/m2 x 1 m = 2,695 kg/m
q2 = 10.8 kg/m2 x 1 m = 10.8 kg/m
Concrete Load
Selfweight of Plywood
2. Bending Moment
Combination Load (Dead Load + Selfweight) :
3. Shear Force
Combination Load (Dead Load + Selfweight) :
4. Displacement
Combination Load (Dead Load + Selfweight) :
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 7 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
5. Reaction
Combination Load (Dead Load + Selfweight) :
Mmax 3,273.00
σmax = = = 60.61 kg/cm2 < 100 kg/cm2 OK
W 54
τmax Dmax x S 20,876
= = = 4.30 kg/cm2 < 12 kg/cm2 OK
Ixb 4,860
L 381
max = 0.297 mm < ijin = = = 0.95 mm OK
400 400
B. Girder GT 24 Control:
Properties :
Concrete Load = 2,695 kg/m2
Selfweight of Plywood = 600 kg/m3 x 0.018 m = 10.8 kg/m2
Selfweight of Girder = 5.9 kg/m
Gap between Girder = 0.381 m
Load :
q1 = 2,695 kg/m2 x 0.381 m = 1,026.79 kg/m
q2 = 10.8 kg/m2 x 0.381 m = 4.11 kg/m
q3 = 5.9 kg/m
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 8 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
Moment :
Mmax = 20,053 kg.cm < M allowable = 71,380 kg.cm OK
Shearing Force :
Dmax = 558.47 kg < D allowable = 1,325 kg OK
Displacement :
δ = 1.069 mm < δ allowable = 4.276 mm OK
C. Steelwale Control:
Properties :
Concrete Load = 2,695 kg/m2
Selfweight of Plywood = 600 kg/m3 x 0.018 m = 10.8 kg/m2
Selfweight of Girder = 5.9 kg/m x 7 pcs = 41.3 kg/m x 1.05 m = 43.36 kg
Selfweight of Steelwale = 18.72 kg /m
Distance given = 1.05 m
Load :
q1 = 2,695 kg/m2 x 1.05 m = 2,829.75 kg/m
q2 = 10.8 kg/m2 x 1.05 m = 11.34 kg/m
q3 = 43.36 kg / 2.39 m = 18.14 kg/m
q4 = 18.72 kg/m
Concrete Load
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 10 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
Selftweight Plywood
Selftweight Girder
3. Shear Force
4. Displacement
5. Reaction
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 11 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
Mmax 28,520
σmax = = = 385.41 kg/cm2 < 1,437 kg/cm2 OK
W 74
τmax Dmax x S 74,917.26
= = = 223.77 kg/cm2 < 958 kg/cm2 OK
Ixb 334.8
L 1200
δmax = 0.331 mm < δallowable = = = 3.33 mm OK
360 360
Allowable Stress
Yeildd Stress () = 4,996.61 kg/cm2 ; Safety Factor = 1.67 (SNI 1729-2020)
Allowable Stress ( ) = / 1.67
= 4,996.61 / 1.67
= 2,991.98 kg/cm2
Area =1/4 π d2
= 1/4 x 3.14 x 1.52
= 1.77 cm2
Allowable Load
P
Allowable Stress =
A
Allowable P = 1.77 cm2 x 2,991.98 kg/cm2
= 5,295.8 kg
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 12 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -
Check :
P = 3,062 Kg < Pallowable = 5,295.8 Kg OK
Signature :
Name : ALF
Date : 27 July 2023