Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Project : No To Do :

HIGH SECURITY BUILDING


Subject : Sheet no :
Static Calculation 1 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

I. TECHNICAL DATA

Image 1.1 Section View

Image 1.2 Top View


Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 2 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

II. MATERIAL PROPERTIES

PLYWOOD 18 mm (Timber Class II ) :


b 100 cm
Ax 180 cm2
Ix 48.60 cm4
100 Wx 54.00 cm3
1.8 Sx 40.50 cm3
Δ max L/400
E 100,000 kg/cm2
σ allowable 100 kg/cm2
τ allowable 12 kg/cm2
GIRDER GT 24 :
b 8 cm
Ax 24 cm2
Ix 8000 cm4
Wx 700 cm3
Sx 525 cm3
Δ max L/500
E 100,000 kg/cm2
M allowable 71,380 kg.cm
D allowable 1,325 kg

STEEL WALER SRZ (Steel ST37) :

b 1 cm
Ax 23 cm2
Ix 372 cm4
Wx 74 cm3
Sx 43.38 cm3
Δ max L/360
E 2,100,000 kg/cm2
σ allowable 1,437 kg/cm2
τ allowable 958 kg/cm2
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 3 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

III. LOAD

 Dead Load
There are 2 types of dead load :
a. Concrete Load
Concrete load used is 2,550 kg/m3, based on DIN 18218:2010.
b. Selfweight material
Selfweight material is weight materials used for formwork
 Material Spesification
a. For timber material used timber class II based on Peraturan Konstruksi Kayu Indonesia (PKKI) 1961
b. For steel material used Steel ST37 with yield strength 2400 kg/cm2 and tensile strength 1600 kg/cm2 based
on Peraturan Perencanaan Bangunan Baja Indonesia 1984 (PPBBI 1984)
c. For Girder GT24 based on guidelines Peri Standard Design Tables 2015
d. For Tie Rod material used steel type S45C with yield strength 4996.61 kg/cm2 and tensile strength 6995.25
kg/cm2.
e. Material RSS & Kicker AV to be ignored for the calculation because this material is used for verticality,
not receives the load from concrete,all load from concrete just recevied to Tie rod DW 15.
 Load Combination
a. Load combination include Dead Load and Live Load with safety factor 1.67 (for allowable yield and tensile
strength).Method used in analysis is Allowable Stress Design (ASD) Method (SNI 1729-2020)
b. Load Combination = 1 DL + 1 LL
 Load Assumption for Horizontal Load
Concrete Density = 2,550 kg/m3

Area casting = 34.18 m2

Capacity of truck mixer = 6 m3/ truck

Estimate qty truck = 4 truck/ hour

Vol. Casting/ hour = 24 m3/hour

Height of casting (R) = 24⁄34.18

= 0.7 m/hour
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 4 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

Horizontal Load Based on ACI 347R-14

Image 3.1 Concrete Lateral Pressure Distribution (ACI 347R-14)

785𝑅
CCpmax = CcCw [7.2 + 𝑇+17.8
]

Cc = Chemistry coefficient
CW = Unit weight coefficient
R = Rate of placement, ft/h (m/h)
T = Temperature of concrete at time of placement, °F (°C)

Table 3.1 Chemistry Coefficient Cc (ACI 347R-14)

Table 3.2 Unit Weight Coefficient Cw (ACI 347R-14)


Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 5 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

From table on obtained :


Cc = 1.2 ( Cement type I,II,III with retarder)
2550
Cw = 2320 kg/m3 = 1.1 ( ᴩ > 2400)

R = 0.7 m/h
T = 25 0C

h: 1.06 m
Lateral Pressure of Concrete :
785𝑅
CCpmax = CcCw [7.2 + ]
𝑇+17.8

= 1.2 x 1.1 x [7.2 + 7.88)


2,695 kg/m2
= 26.43 kPa
= 2,695 kg/m2

Hs = Ccpmax / w
= 2,695 kg/m2 / 2,550 kg/m3
= 1.06 m
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 6 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

IV. STRUCTURE ANALYSIS


A. Plywood Control :
Load Used :
Concrete Load = 2,695 kg/m2
Selfweight of Plywood = 600 kg/m3 x 0.018 m = 10.8 kg/m2

Load Calculation :
q1 = 2,695 kg/m2 x 1 m = 2,695 kg/m
q2 = 10.8 kg/m2 x 1 m = 10.8 kg/m

Result based on STAAD.Pro V8i :


1. Load and support modeling on staad.pro :

Concrete Load

Selfweight of Plywood
2. Bending Moment
Combination Load (Dead Load + Selfweight) :

3. Shear Force
Combination Load (Dead Load + Selfweight) :

4. Displacement
Combination Load (Dead Load + Selfweight) :
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 7 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

5. Reaction
Combination Load (Dead Load + Selfweight) :

6. Result of Structural analysis on combined load :

Mmax = 3,273.00 kg.cm Dmax = 515.46 kg max = 0.297 mm

Mmax 3,273.00
σmax = = = 60.61 kg/cm2 < 100 kg/cm2 OK
W 54
τmax Dmax x S 20,876
= = = 4.30 kg/cm2 < 12 kg/cm2 OK
Ixb 4,860
L 381
max  = 0.297 mm < ijin = = = 0.95 mm OK
400 400

B. Girder GT 24 Control:
Properties :
Concrete Load = 2,695 kg/m2
Selfweight of Plywood = 600 kg/m3 x 0.018 m = 10.8 kg/m2
Selfweight of Girder = 5.9 kg/m
Gap between Girder = 0.381 m
Load :
q1 = 2,695 kg/m2 x 0.381 m = 1,026.79 kg/m
q2 = 10.8 kg/m2 x 0.381 m = 4.11 kg/m
q3 = 5.9 kg/m
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 8 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

Result base on STAAD.Pro V8i :


1. Load and support modeling on staad.pro

Concrete Load Selftweight Plywood Selfweight Girder


2. Diagram force modeling on staad.pro

Bending Moment Shear Force Displacement Reaction


Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 9 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

3. Result of Structural analysis on combined load


Permissible force from Peri Design Table 2015:

Moment :
Mmax = 20,053 kg.cm < M allowable = 71,380 kg.cm OK

Shearing Force :
Dmax = 558.47 kg < D allowable = 1,325 kg OK

Displacement :
δ = 1.069 mm < δ allowable = 4.276 mm OK

C. Steelwale Control:
Properties :
Concrete Load = 2,695 kg/m2
Selfweight of Plywood = 600 kg/m3 x 0.018 m = 10.8 kg/m2
Selfweight of Girder = 5.9 kg/m x 7 pcs = 41.3 kg/m x 1.05 m = 43.36 kg
Selfweight of Steelwale = 18.72 kg /m
Distance given = 1.05 m
Load :
q1 = 2,695 kg/m2 x 1.05 m = 2,829.75 kg/m
q2 = 10.8 kg/m2 x 1.05 m = 11.34 kg/m
q3 = 43.36 kg / 2.39 m = 18.14 kg/m
q4 = 18.72 kg/m

Result base on STAAD.Pro v8i :

1. Load and support modeling on staad.pro

Concrete Load
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 10 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

Selftweight Plywood

Selftweight Girder

Selftweight Steel Wale


2. Bending Moment

3. Shear Force

4. Displacement

5. Reaction
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 11 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

6. Result of Structural analysis on combined load:

Mmax = 28,520 kg.cm Dmax = 1,727.00 kg δmax = 0.331 mm

Mmax 28,520
σmax = = = 385.41 kg/cm2 < 1,437 kg/cm2 OK
W 74
τmax Dmax x S 74,917.26
= = = 223.77 kg/cm2 < 958 kg/cm2 OK
Ixb 334.8
L 1200
δmax = 0.331 mm < δallowable = = = 3.33 mm OK
360 360

D. Tie Rod DW15 Control

P = 3,062 Kg (Reaction from Steelwale)

Tie Rod DW 15 (S45C JIS G 4051 – Japan )


Yield Strength () = 490 Mpa ≈ 4,996.61 kg/cm2 (standard)
Tensile Strenght (τ) = 686 Mpa ≈ 6,995.25 kg/cm2 (standard)

Allowable Stress
Yeildd Stress () = 4,996.61 kg/cm2 ; Safety Factor = 1.67 (SNI 1729-2020)
Allowable Stress (  ) =  / 1.67
= 4,996.61 / 1.67
= 2,991.98 kg/cm2

Section Area Tie Rod DW 15

Area =1/4 π d2
= 1/4 x 3.14 x 1.52
= 1.77 cm2

Allowable Load
P
Allowable Stress = 
A
Allowable P = 1.77 cm2 x 2,991.98 kg/cm2
= 5,295.8 kg
Project : No To Do :
HIGH SECURITY BUILDING
Subject : Sheet no :
Static Calculation 12 of 12
Area : Date : Rev :
Wall PERI VARIO h: 6.3 m (Stage 2) 27 July 2023 -

Tensile Strength On Tie Rod DW15 :


Reaction From Steel Wale = 3,062 Kg
Allowable Capacity tie rod DW 15 = 5,295.8 Kg

Check :
P = 3,062 Kg < Pallowable = 5,295.8 Kg OK

Approved By : Check By : Made By :

Signature :
Name : ALF
Date : 27 July 2023