Big Display Electromagnetic Flowmeter
1 www.flow-meter.cc
QTLD
1. Products Features
Features
•Size : DN15~DN3000
•Accuracy :+ 0.5%,+ 0.3% are selectable
•Flow velocity : 0.1 m/s ~ 15m/s
•Media temperature :-20℃~+160℃
•Ambient temperature :-25℃~+ 60℃
•Housing material: Carbon steel with epoxy painting, Stainless Steel (SS304.SS316 selectable) DN15-
DN3000
•Electrode with shielding case,signal stable
•Electrode material: SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinoiridium etc
•Electrode type: General type,scraper type
•Liner material: PTFE, Rubber, PFA,FEP, PU etc
•Protection class: IP65
•Power supply: DC24V, AC220V
•Communication: RS485 and HART are available.
•Flow output: Analog output,frequency output,pulse output
•Control output : forward / reverse,high alarm / low alarm etc.
•Control input : external zero return,external totalizer reset,external totalizer stop
•Pulse output : active / passive,frequency and pulse width adjustable
•Test and diagnosis : self - diagnosis, failure record, current output test,control input
/ output test, emulation test mode etc.
•Others : parameter protection, indication of sensor parameter,span adjustment,
zero adjust,small signal cutting, smoothing, access to external memorizer
,writing No. etc
Applications
Water Abstraction
Water purification and desalination
Drinking water distribution networks
Revenue metering or billing
Leakage detection
Irrigation
Industry water
Cooling water
Wastewater
Sewage and sludge
Sea water
www.flow-meter.cc
QTLD
Structure
4
QTLD
2. Converter
QTLD/ converters drawing and features
Compact Converter
Real Pic
LCD Display
www.flow-meter.cc
QTLD
Basic Function
Executive Standard: JB/T9248-1999 GB 3836.1-2010
GB 3836.2-2010 GB 3836.4-2010
Current speed range:0.03m/s~12m/s
Repeatability: ±0.1%
Display
English displaying mode can display the instantaneous flow, the percentage of flow, the
total forward flow and reverse flow
Output signal:
Analog output:4~20mA Load resistance:<750Ω
Frequency: 0~5kHz 24V
Pulse
RS485 communication
HART(selectable)
Excitation mode
Three amplitude low frequency excitation
High frequency excitation
Excitation Frequency
1/16、1/8、1/4、1/2 can be set
Excitation Electricity
160mA or specified
Time Constant
0.1~99.9 Second can be set
Ex-proof Mark
Exd[ia]iaIICT5
www.flow-meter.cc
QTLD
www.flow-meter.cc
QTLD
4. Installation Notice
Installed at the lowest point and vertical upward direction Install exhaust valve at the downstream of flow meter
Don’t install at the highest point and vertical downward direction when drop is more than 5m
Installed at the lowest point when used in open drain pipe Need 10D of upstream and 5D of downstream
Dont’ install it at the entrance of pump, install it at the exit of pump Installed at the rising direction
www.flow-meter.cc
QTLD
5. Model Selection
www.flow-meter.cc
QTLD
www.flow-meter.cc
QTLD
7. Features of the liner material and electrode material
Teflon
FEP
Polyurethane
www.flow-meter.cc
QTLD
8.Main Performances of Electrode Materials
Hastelloy B (HB)
Hastelloy C (HC)
Titanium
Tantalum
Having strong resistance to corrosive mediums that is similar with glass. Almost applicable
in all chemical mediums.Except for hydrofluoric acid,oleum and alkali.
Platinium-irridium
Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.
14 www.flow-meter.cc