WALL REINFORCING AT WALL REINFORCING AT

TYPICAL DUCTILE MOMENT FRAME BEAM DETAIL TYPICAL FRAMING PLAN OF CORNER INTERSECTION
TWO WAY SLAB ADDITIONAL Ø10 @ 400 O.C. 400
CHB WALL
CHB WALL

C COLUMN C COLUMN C COLUMN

LC L1 L2

400
0.75 LC OR 0.25 L1 0.25 L1 OR 0.25 L2 0.25 L2 OR 0.25 L1 0.25 L2 2 - Ø 16 EXTRA VERT. BARS ADDITIONAL Ø10
(GREATER GOVERNS) 0.25 L1 OR 0.75 LC (GREATER GOVERNS) 2 - Ø 16 EXTRA VERT. BARS @ 400 O.C.
(GREATER GOVERNS) CHB VERT. REINF. (SEE
CHB VERT. REINF. (SEE SCHED. OF REINF.)
1.3 Ld 1.3 Ld SCHED. OF REINF.)
CHB HOR. REINF. (SEE
CHB HOR. REINF. (SEE SCHED. OF REINF.)

40mm OVER (TYP.)


EQ. EQ. TOP BARS EQ. EQ. SCHED. OF REINF.)
AT SUPPORT

STRIP
TOP BARS AT

COL

L/4
CANTILEVER'S TOP BARS TOP BARS CONTINUOUS TOP BARS
DISCONTINUOUS AT SUPPORT AT MIDSPAN WEB BARS AT MIDSPAN
END

LONG CLEAR SPAN "L"

MIDDLE
STRIP
L/2
WALL REINFORCING AT END BLOCK WALL REINFORCING AT R.C. COLUMN/WALL

STRIP
COL

L/4
CHB WALL ELASTIC SEALANT

COVER
(TYP.)
40mm
2d EQ. EQ. 2d 2d EQ. EQ. POLYURETHANE BACKING
BOTTOM BARS NO SPLICE SPLICE ZONE BOTTOM BARS

CHB "t"
CHB WALL
AT MIDSPAN SHALL BE FOR BOTTOM AT MIDSPAN
ALLOWED 2d BARS

BOTTOM BARS 0.165 L1 BOTTOM BARS


FROM THE
0.165 L2
TWO WAY SLAB
FACE OF THE
AT CANTILEVER'S AT SUPPORT SUPPORT
DISCONTINUOUS 0.22 L1 0.22 L2 1 - Ø 16 MM
END CHB HOR. REINF. (SEE
50mm MAX. 50mm MAX.
SHOWING TOP BAR REINFORCEMENT SCHED. OF REINF). RC COLUMN OR
CHB VERT. REINF. SEE
SCHED. OF REINF.
AT SUPPORT AT SUPPORT WALL
CHB HOR. REINF. SEE
SCHED. OF REINF.
SHORT CLEAR SPAN "S" 1 - Ø 16 EXTRA
HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT VERT. REINF.
SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE
* WHICHEVER IS LARGER GOVERN. COL MIDDLE COL
STRIP STRIP STRIP WALL BASE REINFORCING AT FLOOR W/ 400
S S S
CONTINUOUS END CONTINUOUS END DISCONTINUOUS END 4 2 4 DEPRESSION
FREE END

CHB WALL
WALL BASE REINFORCING AT FLAT FLOOR

STRIP
LONG CLEAR SPAN "L"
COL

L/4
CHB VERT. REINF. (SEE
SCHED. OF REINF.)
CHB WALL

MIDDLE
STRIP
CHB VERT. REINF. DOWELS CHB VERT. REINF. (SEE

L/2
TYPICAL SEISMIC RESISTANT COLUMN DETAIL KEY COLUMN ELEVATION SECTION (TO MATCH VERT. REINF.) SCHED. OF REINF.)

400
STRIP
COL

L/4
CHB VERT. REINF. DOWELS
(TO MATCH VERT. REINF.)

400
SUSPENDED SLAB

SLAB
DEP.
JOINT HOOPS MUST BE SPACED AT "2Sh" FOR THE DEPTH OF THE
SHALLOWEST BEAM WHEN BEAMS W/ WIDTH > 3/4 TIMES THE WIDTH
OF THE COLUMN FRAME INTO THE FOUR SIDES OF A COLUMN. TWO WAY SLAB SUSPENDED SLAB
CONF. REINF.

LINE OF DEPRESSED SLAB @


FOR ALL OTHER CONDITIONS, USE HOOPS SPACED AT "Sh" O.C.
SHOWING BOTTOM BAR REINFORCEMENT
Lo

OTHER SIDE WHEN REQUIRED


50mm

TYP. STIFFENER COLUMN DET. ON CHB


JOINT REINF.

ROOF BEAM LEVEL 10 mmØ BAR CHAIR TYP.CHB STIFFENER BEAM DETAILS
TEMP. REINF.
AS REQUIRED WALLS
Sh 50mm

t
CONF. REINF.

LAP SPLICE ONLY W/IN CENTER HALF OF CLEAR


(Z1)

S/4 S/2 S/4


H/4

Lo

COLUMN HEIGHT. (SEE TABLE OF MIN. LAP LAP SPLICE LENGTH AT ANY
2Ø12 VERT. BAR
VERIFY

SPLICE LENGTH OF COLUMN REINFORCEMENT) LEVEL NO MORE THAN 50% COLUMN STRIP MIDDLE STRIP COLUMN STRIP
FOR COL. BAR SPLICES SEE TABLE OF MIN. OF VERT. BARS SHOULD BE Ø10 TIES SPACED@
S 2Ø12 VERT. BAR
LAP SPLICE LENGTH OF COL. SPLICED. 150 O.C TO C.L (TYP.)
MIN. DISTANCE BET. TWO CLEAR SPAN-SHORT CHB. VERT. REINF. (SEE ALTERNATELY PLACED
COLUMN TIES AS

REINFORCEMENT
PER SCHEDULE

SCHED. OF REINF.) (FOR 4M CMU WALL HEIGHT)


Slap

ADJACENT INTERVAL BARS


SPLICES SHALL BE NO LESS
THAN 800 MM.
(Z2)
H

Ø10 SPACED
2ND FLOOR BEAM LEVEL SECTION @150 O.C (TYP.)
ALTERNATELY PLACED
(TWO-WAY SLAB)
Sy

(FOR 3M CMU WALL HEIGHT)


4Ø12 VERT. BARS W/1Ø10
Sh = HOOPS & CROSSTIE SPACING NOT TIES; SPACED@150
TO C.L (TYPICAL)
CONF. REINF.

TO EXCEED Bs/4. 6Db VERTICAL OR Sc


H/4

(FOR 4M CMU WALL HEIGHT)


(Z1)

Lo

(350 - hx)
Sh

Sc = 100 +
50mm

3 LOC. OF GROUND BEAM


VERIFY

100MM THK SLAB ON GRADE


Sy = TIE SPACING NOT TO EXCEED
w/ 10MMØ BAR @400MM
6Db of VERTICAL or 150mm COMPACTED
O.C.B.W. w/ 75 MM THK
Slap = TIES SPACING, NOT TO EXCEED
SUITABLE BACKFILL
ATLEAST 95%
GRAVEL BED. WALL SUPPORT AT BOTTOM OF WALL SUPPORT AT BOTTOM EDGE OF WALL TOP SUPPORT IN AREAS W/
THE SMALLER OF Bs/4 OR 100MM
MAXIMUM DRY
SLAB/BEAM BEAM DROPPED CEILINGS
50mm

Bs = SMALLER DIMENSION OF COLUMN CROSS DENSITY(ASTM D-1557)


SECTION GROUND FLOOR LEVEL/
TOP OF TIE BEAM 6MM THK. PL ANCHORED TO CONCRETE
Lo = LARGEST COLUMN DIMENSION, BUT NOT LESS SLAB W/ 2-Ø10 POWDERED ACTUATED
STUD OR WELDED TO BOT. OF STL. TRUSSES
THAN 1/6 CLEAR HEIGHT, OR 450MM 2-Ø10 POWDER ACTUATED
STUD ANCHOR (OR EQUAL)
BOTTOM OF CONCRETE
2.00M(min.)

NAT. GROUND LEVEL 25 COMPRESSIBLE FILLER L 64 x 64 x 6MM


NATURAL SOIL SLAB/BEAM 200 X 300 X 6 PL. SUPPORT
min. MATERIAL BRACE @ 1200 O.C.
@ 1200 O.C.

25
D1

BOT. OF FOOTING COMPRESSIBLE FILLER MATERIAL


min.
COLUMN LAP SPLICE AND EXT. GIRDER L 75 X 75 X 6 X 300 LG. CHB WALL LINTEL BLOCK W/ 2 - Ø 16
SUPPORT @ 1200 O.C. TOP OF CHB WALL
TO COLUMN CONNECTION DETAIL L&B
75MM THK GRAVEL BED
TYPICAL TO ALL FOOTINGS CHB. VERT. REINF. (SEE
CONT. HOR. REINF.
WT6X13x4"LG. W/
SCHED. OF REINF.) 100LG. FOR 1-Ø16MM
L75X75X6X300LG. CHB WALL 2-Ø10X150LG.
BOLT.
SUPPORT @ 1200 O.C. ANCHOR BOLTS
2 - Ø 10 POWDER ACTUA- CHB. VERT. REINF. (SEE
TED STUD ANCHOR (OR SCHED. OF REINF.) CEILING LINE LINTEL BLOCK
EQUAL) 2 - Ø 10 POWDER
LAP SPLICE LENGTH: 2 - Ø 16 CONT.
ACTUATED STUD ANCHOR
1. AT ANY LEVEL NO MORE THAN (OR EQUAL) HORIZONTAL BARS
ALTERNATE BARS SHOULD BE CHB VERT. REINF.
H (CLEAR HEIGHT OF COL.)

SPLICED. (SEE SCHEDULE


FOR REINF.)
2. MIN. DISTANCE BETWEEN TWO
ADJACENT BAR SPLICES SHALL
BE 600mm.
L
WITHIN CENTER
HALF OF "H"

L/4 CHB EXTENSION LINTEL BLOCK IF REQ'D. PIPE SLEEVE THRU WALL SECTION 3a
CHB "t"
TOP BARS @ SUPPORT (CONT.) CHB "t"
8a
CHB "t" S-9
REQ'D. BOT. BARS @ SUPPORT PIPE SLEEVE
BARS ALONG L
CONC. EXTENSION REQUIRED
WHEN REQUIRED
L

W/ 1-Ø16 REINF.
JT. REINF.
LAT. TIES

CHB WALL CONCRETE FILLER


BARS ALONG B
PIPE

CHB. VERT. REINF. (SEE


CONF. REINF. TIES

CONCRETE
EXTRA BOT. BARS SCHED. OF REINF.)
FILLER
@ MIDSPAN
0.165L SPLICE
BOT. BARS B
@ MIDSPAN CHB WALL
MASTIC SEALANT
0.22L EXTRA TOP BARS EACH SIDE
@ SUPPORT LINTEL BEAM : 2 - Ø 10 PIPE SLEEVE
PIPE SLEEVE
CHB. VERT. REINF. (SEE
CONT. HOR. REQUIRED
SCHED. OF REINF.) COMPRESSIBLE
REINFORCEMENTS W/
MATERIALS
10mmØ C-Type STIRRUPS
@ 200mmO.C. CHB WALL

THIS DRAWING AND OTHER PROJECT TITLE: DEVELOPER: SHEET CONTENT: REVISIONS: REVISED BY: DATE DRAWN BY: SIGN/DATE SHEET NO.:
DOCUMENTS ARE INTELLECTUAL
Jan 03, 2022 Mark fil M. Sadiwa
PROPERTY OF METROSTAR GENERAL CONSTRUCTION NOTES 1
TWO STOREY UNIT
REALTY AND DEVELOPMENT INC.
IT IS UNLAWFUL TO DUPLICATE OR
TO MAKE COPIES OF SAID
SINGLE ATTACHED 01 MODEL METROSTAR 2
3
CHECKED BY:
Engr. Jade Manabat
S-2
DOCUMENTS WITHOUT THE EMINENZA RESIDENCES IV REALTY & DEVELOPMENT INC. 4
WRITTEN CONSENT OF THEIR
ARCHITECT. ALL DRAWINGS AND PRC No.: PTR No.: (ALTA PRIMA) 5 APPROVED BY: 2 5
DOCUMENTS ARE TO BE KEPT FOR ISSUED ON: ISSUED AT: BAYANI ROAD, BRGY. TUNGKONG MANGGA, ADDRESS: 839 EDSA SOUTH TRIANGLE, QUEZON CITY Ar. John Henson
REFERENCE. (R.A. 9266) TIN No.: LOCATION: PROJECT NO.: DATE: OCT. 5, 2022
CITY OF SAN JOSE DEL MONTE, BULACAN Mr. Eugene Eugenio