SI-400 User's Manual-B5 - 05 Beep Rev1
SI-400 User's Manual-B5 - 05 Beep Rev1
SI-400 User's Manual-B5 - 05 Beep Rev1
User's Manual
INTERNAL TYPE
400-4
TABLE OF CONTENTS Control panel LED
Caution --------------------------------------------------------------- Page 4 Audible alarm On battery alarm: Low battery alarm, Over load alarm,
Short-circuit alarm, Thermal alarm
1. Over view and Features ----------------------------------------- Page 5
Green mode 1% to 14% of full load
2. Installation ----------------------------------------------------------- Page 6 function (adjustable by using the setting software)
3. Operation ------------------------------------------------------------- Page 7 (Auto-shutdown
during blackout) The default setting is 7%( 20W typical)
4. Communication interface---------------------------------------- Page 9
5. Trouble shooting --------------------------------------------------- Page 11 Environmental and Safety
6. Specifications ------------------------------------------------------- Page 12 Operating
Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Temperature
Transit/storage
-15℃ to 55℃ (5℉ to 131℉)
Temperature
Audible noise at 1
M from surface of ≦35 dBA
unit
Safety Markings CE
Quality control
ISO9001
standard
Physical
Dimension SI-400:242 x 144 x 40 (mm)
D×W×H (cm) SI-401 / 402 / 425(U):192 x 144 x 40 (mm)
Packing Color box for each unit, 6 pcs in one export carton, and around
180 units per pallet.
14
Battery IMPORTANT SAFETY INSTRUCTIONS
Battery type SI-400:Maintenance-free sealed, Lead-Acid 6V/3Ah * 2 ● When replacing the batteries, use the same number and the same
SI-401︰Li-Polymer battery 12.8V/1800mAh x 1 pack
type of batteries.
13 2
German wording: 6. SPECIFICATIONS
● Wenn Sie die Batterien austauschen, verwenden Sie bitte die Output
gleiche Anzahl und den gleichen Batterietyp. 115V Models 230V Models SI-425U
● Werfen Sie niemals die Batterien in das Feuer, die Batterien könnten
Power Levels SI-400 / 401 / 402:400VA / 240W
explodieren.
(at nominal inputs) SI-425(U):425VA / 255W
● Öffnen oder beschädigen Sie nicht die Batterien,
ausfileβendes Elektrolyt ist schädlich für Haut und Augen. Output Voltage 100V/110V/115V/120V 200V/220V/230V/240V
Selectable Selectable
120Vac
● Eine Batterie kann eine Gefahz eines elektrischer Schlages und
sehr groβer Kurzschluβströme beinhalten. Folgenda Voltage Waveform Simulated Sine wave
Vorkehrungen soiiten getroffen warden, wenn Sie mit der
Battery arbeiten. Output Frequency Auto Select for 50/60Hz
* Entfernen Sie Uhren, Ring and andere metallische Objekte. (sync to mains) 45Hz ~ 55Hz for 50Hz nominal
* Verwenden Sie Werkzeug mit isolierten Griffen. 56Hz ~ 65Hz for 60Hz nominal
● Bedienung durch jedermann ohne dem Vorkenntnisse. Regulation ±5% of selected output voltage.
(Battery mode) (adjustable by using the setting software)
● “Vorsicht, Gefahr durch elektrischen Schlag. Auch nach Trennung
von der Netzeingangsspannung werde Teile innerhalb der USV von Transfer time 6mS typical
der Batterie gespeist und führen gefährliche Spannung.
Over current Over load alarm level 100% ~ 120%.
● Die Blei-Akkumulatoren Können bei unsachgemäβer Handhabung protection Over load shutdown level 120% ~ 190%.
chemische Gefahren hervorrufen. (Both adjustable by using the setting software)
● Batterien werden durch den Hersteller oder Importeur entsorgt.
Dazu muessen die Batterien kostenfrei angeliefert werden. Input
115V Models 230V Models SI-425U
Nominal Voltage 100V/110V/115V/120V 200V/220V/230V/240V
100V ~ 240V
Selectable Selectable
3 12
5. TROUBLE SHOOTING CAUTION
Problem Possible Cause Action to Take ● The UPS connection instructions and operation described in the
UPS no reaction while AC 1. Line cord plug is loose 1. Check the line cord plug manual must be followed in the indicated order.
is connected 2. Fuse blown 2. Call for service ● Never install the UPS near liquids or in an excessively damp
Power output is normal, UPS is over loaded Turn off UPS and unplug environment.
UPS emits continuous excessive loads from UPS.
beep, status LED shows ● Never let a foreign body penetrate inside the UPS.
RED. ● Never expose the UPS to direct sunlight or source of heat.
No power on outlets, UPS UPS has shut down due to Unplug excessive loads from
emits continuous beep, severe overload. UPS, press button to reset ● If the UPS must be stored prior to installation, storage must be in a
status LED show RED. the buzzer, and turn on the dry place.
UPS again. ● The admissible storage temperature range is -15℃ to +55℃.
UPS does not provide Do not operate the UPS,
1. Excessive loads Once installed and connected to the AC power source for the first
expected run time and leave the UPS ●
connected at UPS’s time, the battery will start to charge. Full charging to obtain the
outlets. plugged in for 10 hours.
Then, test it again, if UPS rated battery backup time requires at least 8 hours.
2. Battery is weak and cannot
provide enough capacity. still cannot provide ● Before and after the installation, if the UPS remains de-energized for
expected run time, a long period, the UPS must be energized for a period of 24 hours,
battery should be at least once every 6 months (for a normal storage temperature less
replaced. than 25 ℃ . This charges the battery, thus avoiding possible
Button on front panel 1. Unplug the line cord & irreversible damage. During the replacement of the battery
1. The CPU inside UPS is module, it is imperative to use the same type and number of element
doesn’t work push the button for 15
not running correctly. previously mounted in the UPS, in order to maintain an identical
seconds to reset the UPS.
2. Button damaged. level of performance and safety. In case of doubt, don’t hesitate to
2. Unplug all loads and
line cord from the UPS contact our after sales department.
to let it shut down ● Never apply the UPS as an Inverter.
automatically, and call
for service.
UPS cannot be turned 1. Battery dead Call for service.
on. 2. UPS fault
This symbol indicates that you should not discard the UPS
or the UPS batteries in the trash. The UPS may contain
sealed, lead-acid batteries. Batteries must be recycled.
11 4
1. OVER VIEW AND FEATURES 4.3 The connection for USB model is shown as follows.
This is a high performance with compact shape stand-by
Uninterruptible Power Supply (UPS) designed to protect your 4.3.1 For SI-400 / 401 / 402 4.3.2 For SI-425(U)
computer from utility line failure. In the event of utility failure
(blackout), the UPS will rapidly transfer loads to an alternative power
source which derives power from battery set inside the UPS. The
backup time for a Pentium Ⅳ PC including LCD monitor is about 6
minutes with internal UPS model SI-400, about 9 minutes with the
model SI-401 or SI-425(U), and about 18 minutes with the model
SI-402.
5 4 3 2 1
9 8 7 6 2.5 After installation with normal city power, the UPS will charge the
battery automatically; please keep the UPS in charging for 5 hours, at
least.
4.2.1 SI-400 / 401 / 402 Pin Definition SI-425(U)
Pin #6 RS-232 data Tx out (Rx:to PC) Pin #3
Pin #7 Common of Pin #6 and Pin #9 Pin #5
Pin #9 RS-232 data Rx In (Tx:to PC) Pin #2
3. OPERATION 3.7 Reset the UPS
3.1 Once it’s connected with normal city power, the UPS will charge the If any abnormal condition occurs, and the item 3.2 ~ 3.4 can not be
battery automatically, when UPS is off, the green LED blinks every 2 executed, please unplug the line cord and push the button for at
seconds. If AC auto turn-on function is enabled, the UPS will turn least 15 sec., which will reset the UPS.
on automatically when city power is normal. If auto turn-on is 3.8 Audible alarm
disabled, please push the button for about one second on the front
panel; then the UPS will give power to the load. During a utility failure or fault operation, the UPS emits beep for
warning. In back-up mode, the alarm can be silenced by pushing the
button. However, the warning of low battery will still sound for urging
Red / Green LED user to leave computer without any data loss.
Control button Basic Indication Table:
STATUS ALARM LED