SY210 – Pump Abnormal Sound

Objective: To decide the improvement action on Main Pump Abnormal Sound Failures in SY210 (pump mode code:
A3V112DT-1X7R-9NB9-14BV)
Failures Trend:
4 280 No. of No. of Build 300
SY210/220 - Pump Failure Machine
internal part localized 250
221
3 197 197 207 205 217 198
192 181
169 170 200
143 153 145
2 131 134 134 131 121 150
116
102 101 110 100 113
100
1
16 50
0 1 0 0 0 0 0 0 2 0 2 2 3 0 1 0
0 0

8
Summary 7
North; 7

6
No. of Build Machine 4184 5
4
No. of Failure 11 West; 3
3

Avg. Failure % 0.26% 2


East; 1
1
South; 0
Avg. Failure HMR (No. in Hrs) 642 0
East West South North

Field Visit Results on affected Machine: SY210-18SEY021839061 Wipro KPM Pump Sl. No.: 17XW0383 at 1784
hrs: (Delivery pressure P1 & P2, Drain pressure, Suction pressure data)

Observed values:
Pressure Points P1 Pump P2 Pump Drain Pressure Suction Pressure
Observed Values 368.2 bar 363.3 bar 0.33 bar Min -0.55 bar

Suction Pressure Results of affected Machine:


Field Visit Results on Other Machine for Benchmarking: SY210-15SEY0218006451 KPM Pump Sl. No: 154C0648 at
6874 hrs: (Drain and Suction Pressure data)

Observed values:
Pressure Points P1 Pump P2 Pump Drain Pressure Suction Pressure
Observed Values Not measured Not measured 0.73 bar Min -0.50 bar

Observation and Results:

Machine Workin Pump Pump Pump Standard


Model Pump Model
Number g HMR Type Structure Noise Noise
K3V112DT-
SY210 (Affected 18SEY02183906 General Open 88-90
1700 1X7R-9ND9- 90 dBA
Machine) 1 pump Compartment dBA
14BV
SY210 Low
15SEY02100645 K3V112DTP1Y9 Closed 85-86
(Benchmarking 6874 Noise 90 dBA
1 R-9P59-AV Compartment dBA
Machine) Pump

Suction pressure is more than specs. in KPM & WKPM device (more than -0.1 bar). However, it has been observed
that in WKPM suction pressure is not stable.

Root Cause by Team:


1) Valve plate notch is of smaller size leading to venturi effect. Also casing is not reinforced completely for sound.
Hence, noise being observed.
2) Suction pressure is lower than specs. In both the KPM Pump K3V112DTP1Y9R-9P59-AV and WKPM Pump
K3V112DT-1X7R-9ND9-14BV (Standard >=0.1 Bar). This is also leading to increase in venturi effect.
KPM WKPM

Solution Proposed by WKPM:


1) Low noise pump, Casting reinforcement and valve plate notch is bigger. This helps in noise reduction by 4 dbA
2) Low noise pump material weight will increase by 5-6 kg due to addition of casting reinforcement.
3) Low noise and regular pump are available in India market for usage.

Actions:
1) Noisy pump to be sent to KPM, Japan for noise check…..Resp. WKPM
2) Detailed comparison between regular and low noise pump will be shared by 23 rd May…….Resp. WKPM

Thanks you !