SY210 - Pump Abnormal Noise
SY210 - Pump Abnormal Noise
Objective: To decide the improvement action on Main Pump Abnormal Sound Failures in SY210 (pump mode code:
A3V112DT-1X7R-9NB9-14BV)
Failures Trend:
4 280 No. of No. of Build 300
SY210/220 - Pump Failure Machine
internal part localized 250
221
3 197 197 207 205 217 198
192 181
169 170 200
143 153 145
2 131 134 134 131 121 150
116
102 101 110 100 113
100
1
16 50
0 1 0 0 0 0 0 0 2 0 2 2 3 0 1 0
0 0
8
Summary 7
North; 7
6
No. of Build Machine 4184 5
4
No. of Failure 11 West; 3
3
Field Visit Results on affected Machine: SY210-18SEY021839061 Wipro KPM Pump Sl. No.: 17XW0383 at 1784
hrs: (Delivery pressure P1 & P2, Drain pressure, Suction pressure data)
Observed values:
Pressure Points P1 Pump P2 Pump Drain Pressure Suction Pressure
Observed Values 368.2 bar 363.3 bar 0.33 bar Min -0.55 bar
Observed values:
Pressure Points P1 Pump P2 Pump Drain Pressure Suction Pressure
Observed Values Not measured Not measured 0.73 bar Min -0.50 bar
Suction pressure is more than specs. in KPM & WKPM device (more than -0.1 bar). However, it has been observed
that in WKPM suction pressure is not stable.
Actions:
1) Noisy pump to be sent to KPM, Japan for noise check…..Resp. WKPM
2) Detailed comparison between regular and low noise pump will be shared by 23 rd May…….Resp. WKPM
Thanks you !