GENEW Technologies Co., Ltd.

GLS Platform Overview


Sep 2020
Overview of GLS Chassis
§ 2RU Height Chassis § Common Software Platform
• Fit into 19”, 600mm depth Rack
• Infrastructure of common functions for the GLS
• 110/220 VAC (&230VDC) and -48VDC Power supply
network element
• -5~40degC (45degC short time) Operating temperature • Equipment Management
range
• Security and User management
• 440mm(W), 88mm(H), 470mm(D)
• Common service
• Front to rear air flow – NTP, time
Common Hardware Platform for Open LineSystem – Logging
– Software management
• Pluggable 1+1 Redundancy chassis Controller
– Database
• Pluggable 1+1 Power Supply redundancy – Telemetry
• Pluggable 2+1 Fan module redundancy • Model neutral management framework design
• Pluggable Display Panel for system information display and • Netconf, WebGUI, CLI, gRPC (for Telemetry)
maintenance operation
• Hardware Abstraction design adaptive to
• Passive Backplane design with highreliability
hardware implementation
• 2RU passive MUX (AAWG, one wire manageable)
• Future-proof backplane control bus forflexibility • Data driven design for simplification of software
• Ethernet, SPI, UART, I2C, Control bus development on new HW
• Universal 4 service slots to support variantoptical function • L2/L3 Networking for common DCN management
modules: network application, OSPF dynamic routing
• Switch gain amplifiers (<6.5dB NF, 15~32dB gain, • General optical service abstraction based on
24dBm output power) OpenConfig like model
– Booster and preamplifier
• Local optical power control on degree power
• Optical Protection Switch
• WSS-20 for ROADM Degree, up to 20 degrees
balance
www.genew.com
View of the GLS Chassis

Front view

Rear view

www.genew.com
Mechanics of the GLS Chassis (2)
OLED:
Chassis Info/status dispaly
Button:
Maintenance, remote feedback
Slot 1 Slot 2
Front view
SN/PN/ SN/PN/
L OG

Panel
Barcode Barcode
STAT
A/M
O

S lo t 1

S lo t 2
OUT IN

OUT IN
IP: 172.120.10. 10

Slot 40 STAT LINE SIG


O A -S W G BLANK

USB-C: USB Button SN/PN/


Barcode
SN/PN/
Barcode
S lo t 3

S lo t 4
USB 3.0(host)

OUT IN

OUT IN

OUT IN
ETH CON

OUT IN

OUT IN
S lo t 40

STAT LINE SIG STAT A B SIG


O A -S W G OPS
PANEL

ETH port:
local Craft Ethernet
(default 169.254.0.1/16) Slot 3 Slot 4
CON port:
Console port (RS232, 8N1, 115200)
3xFAN 2xCU (controller)
(2+1 redundancy) (1+1)
Rear view Slot 41
MUX1 MUX Interfaces (2x):
Slot 50 Two 1-wire (RJ45) for
F A N 31

F A N 32

F A N 33

C U 41
Slot 21 extended MUX/FMC chassis
ACT/STBY
Slot 51
management
2xPSU
P S U 21

STAT CU
MUX2

NMS1

Slot 22 NMS Interfaces (2x):


(1+1)

C U 42
Two Ethernets forremote
P S U 22

ACT/STBY

management access
STAT
FAN
STAT
FAN
STAT
FAN
STAT
CU
NMS2 www.genew.com
Slot 31 Slot 32 Slot 33 Slot 42
GLS Network Application In DCI

Controller

DCN

Router
Router Router
OSPF or OSPF or OSPF or

OO
OT
L2 &
Static Routing (Gateway) Network connection for
L2 &
Static Routing (Gateway)
L2 &
Static Routing (Gateway) OO
OT
TT access redundancy
TT

OO Network connection for OO


OT
OT access redundancy
TT
TT
Network connection for Network connection for

OO
OT
access redundancy and
ILA access
access redundancy and
ILA access
OO
OT
TT TT
Muxponder/
Muxponder/
Transponder
Transponder

DC Switch DC Switch
GLS DWDM Network www.genew.com
Application Configuration
– Point to Point Fixed OADM of 96 channels with OMS Protection
§ 50G Grid, 96 channels, OMS Protection

www.genew.com
Application Configuration
– Point to Point Fixed OADM of 96 channels with OMS Protection and ILA

§ 50G Grid, 96 channels, OMS Protection, with ILA (In-Line Amplifier)

Linear without
protection

www.genew.com
A/M
STAT
D4 M4 D3 M3 D2 M2 D1 M1

USB

ETH CON
D8 M8 D7 M7 D6 M6 D5 M5

LOGO

IP: 172.120.10.10

Button

PANEL
D12 M12 D11 M11 D10 M10 D9 M9
S lo t 40 S lo t 3 S lo t 1

D16 M16 D15 M15 D14 M14 D13 M13

STAT
STAT
D24 M24 D23 M23 D22 M22 D21 M21

D20 M20 D19 M19 D18 M18 D17 M17

D28 M28 D27 M27 D26 M26 D25 M25

D32 M32 D31 M31 D30 M30 D29 M29

OUT IN OUT IN
D36 M36 D35 M35 D34 M34 D33 M33

LINE
LINE
D40 M40 D39 M39 D38 M38 D37 M37
OA-SWG (A)

D44 M44 D43 M43 D42 M42 D41 M41

OA-SWG (B)
OUT IN OUT IN

SIG
SIG

D48 M48 D47 M47 D46 M46 D45 M45

D52 M52 D51 M51 D50 M50 D49 M49


Chassis Configuration

SN/PN/
SN/PN/

Barcode
Barcode

D56 M56 D55 M55 D54 M54 D53 M53


O A -S W G
O A -S W G

MUX-96
D60 M60 D59 M59 D58 M58 D57 M57

D64 M64 D63 M63 D62 M62 D61 M61


STAT

D68 M68 D67 M67 D66 M66 D65 M65

D72 M72 D71 M71 D70 M70 D69 M69 OUT IN


A

D76 M76 D75 M75 D74 M74 D73 M73

D80 M80 D79 M79 D78 M78 D77 M77

OUT IN
B

OPS

D84 M84 D83 M83 D82 M82 D81 M81

D88 M88 D87 M87 D86 M86 D85 M85

OUT IN
D92 M92 D91 M91 D90 M90 D89 M89
SIG

D96 M96 D95 M95 D94 M94 D93 M93


BLANK FILLER

OUT IN
OPS
SN/PN/

SN/PN/
Barcode

Barcode
BLANK

Logo

SN/PN
Barcode
MUXDMUX

MUX-96

S lo t 4 S lo t 2

PSU F A N 31 P S U 21

F A N 32

F A N 33
MUX-96
GLS Chassis

Rear Side

C U 41
MUX
RJ45 cable

MUX port
www.genew.com
MUX1 port
Rack Configuration of Fixed OADM Terminal W/ OMSP
RACK
COMMSCOPE

45 45

44 44

43 43

§ Blue port
42 42

41 41

34 Third Party Muxponder 34

• fiber connection within


40 40

39 39

Third Party Muxponder


chassis
38
33 33

37

Third Party Muxponder § Green port


36

35
32 32

Third Party Muxponder

• fiber connection with other


34 34

33 Third Party Muxponder 33

31 31

chassis of GLS system


32 Third Party Muxponder 32

31 31

30

29
30

29
30 30

§ Red port
• fiber connection of line
M 64 D63 M 63 2 M 62 D61 M 61
D16 M 16 D15 M 15 D14 M 14 D13

D52 M 52 D51 M 51 D50 M 50 D49

Log
M 56 55 M 55 4 M 54 D53 M 53

o
D4 M 4 D3 M 3 2 M 2 D1 M 1

M 12 11 M 11 0 M 10 M 9

28 28
M 8 D7 M 7 6 M 6 M 5

M 20 M 19 M 18 M 17

M 24 M 23 M 22 M 21

M 28 M 27 M 26 M 25

M 32 M 31 M 30 M 29

M 36 M 35 M 34 M 33

M 44 M 43 M 42 M 41

M 48 M 47 M 46 M 45

M 60 M 59 M 58 M 57
M 40 M 39 M 38 M 37

M UXD

M UX
29 29
OU T
B arco
SN /P

27 27
de

M 13

M 49
N

M U X-

(span transmissionports)
64
SN/P
Barco SN/PN/ SN/P
Barco
LOGO
SSAAT/
M to
1 SN/PN
Slo t 1 Slo t 3 Slo t 40

SSlloott 22 SSlloott 44

/S LOGO Il
T U IN
T U I TN Barcode
N/ O T
U N/ N
IU TI N U N/
OU T

OU T

26 IP: 172.120.10.10 IP: 172.120.10.10 O de O O de


IN

IN

26
STA L SIG O
STAT
T LI
OA -
SIG STAT DEGREE S ADDDROP
BLAN
Logo
USB SW G K
O A - SW G
OU T

OU T

OU T

Button W SS
OU T

OU T

ETH CON SN/P - 20 SN/P


IN

IN

IN
IN

IN

N/ N/
25
STA USB ButtonLIN SIG
Barco
OA -
STAT A B SN/PN/ SIG Barco
O PS
25
28 28

Long fiber will be stored at


PA N E

§
tS T E Barcode
de SN/PN/ de
L CON lo
3 N I N I SW G N I IN I N
ETH lt
S OT
U O
UT OU
T UT
O UT
O M U XD M U X
o
4 STAT
0 SIG OPS STAT LI A LINE B ILA-
PA N EL
SWG

D 40 M 40 D 39 M 39 D 38 M 38 D 37 M 37
D 16 M 16 D 15 M 15 D 14 M 14 D 13 M 13

D 20 M 20 D 19 M 19 D 18 M 18 D 17 M 17

D 24 M 24 D 23 M 23 D 22 M 22 D 21 M 21

D 28 M 28 D 27 M 27 D 26 M 26 D 25 M 25

D 32 M 32 D 31 M 31 D 30 M 30 D 29 M 29

D 36 M 36 D 35 M 35 D 34 M 34 D 33 M 33

D 44 M 44 D 43 M 43 D 42 M 42 D 41 M 41

D 48 M 48 D 47 M 47 D 46 M 46 D 45 M 45

D 52 M 52 D 51 M 51 D 50 M 50 D 49 M 49

D 56 M 56 D 55 M 55 D 54 M 54 D 53 M 53

D 60 M 60 D 59 M 59 D 58 M 58 D 57 M 57

D 64 M 64 D 63 M 63 D 62 M 62 D 61 M 61
24 24

IN
D 12 M 12 D 11 M 11 D 10 M 10 D 9 M 9

OUT
D4 M 4 D3 M3 D2 M 2 D1 M1

D8 M 8 D7 M7 D6 M 6 D5 M5

23 23

fiber storage drawer in the


27 27
S N /P N

B arco d e

22 22
M U X -6 4

21 Third Party Muxponder 21


S N /P N / S N /P N /

rack (depending on the


S N /P N / S N /P N /

SSA
TT/A
A /A
M
MTT
LOGO
LOGO S
B aarc
B rcooddee B aa rc
B rcoo dd ee

l
to lS
Slot1

Slot2
Third Party Muxponder
N N N N
O U T IN

O U T IN
I I T I I
1 t
20 20 T T U N I T T 2
26 IP: 172.120.10.10
IP: 172.120.10.10
U
O
U
O
O U
O
U
O 26

Third Party Muxponder


STA T L IN E S IG
STA T L IN E S IG STA T D EGR EE S IG ADDDROP
19 19
OA-SWG WSS-20
BLANK

drawer availability)
U SB Button S N // P
PNN //
U SB Button S N //P
PNN // SN
S
l B
B aarrc
c ooddee B aarrc
B c ooddee
S
Slot 3 Slot 40

to l
o

Slot4
18 18
N N N N N
3 t4
O U T IN

O U T IN

O U T IN
O U T IN

O U T IN
ETH C ON I I I I I
ETH CON T T T T T
U U U U U

17 17
25 S O O O O O
25
lo
t STA T L IN E S IG STA T A B S IG
STA T A B S IG STA T L IN E A L IN E B
PANEL 4 OA-SWG OPS
PANEL 0 OPS ILA-SWG
16 16

15 15

14 14

13 13

12 12

11 11

10 10

09 09

08 08

07 07

06 06

05 05

www.genew.com
04 04

03 03

02 02

01 01
Hardware Design

Design highlight
• Passive Backplane design provides high reliability
• Backplane Control Interfaces to support both Ethernet Communications and
other frequently used control interface (SPI, UART) simplifying software
implementation on line card
• Distributed Ethernet L2 switch providing redundancy for control and
communication
• Controller 1+1 for future proofed high availability
• All active modules are pluggable units
§ Power consumption
• Sum of power consumption estimation is less than 300W, typical <200W

www.genew.com
Controller Unit
§ Powerful CPU complex § South bound interface
• NXP i.MX 8M 4-Core Cotex-A53 up • Multi slot control ports including
to 1.5GHz ETH, SPI and some low speed bus
• LPDDR4-3200 2G Memory • Multi SGMII for OSC channels on
• eMMC on-board storage and slots
removable SD-card • Independent inventory/thermal bus
• Intel Cyclone 10 FPGA • PSU control bus
§ L2/L3 Broadcom Switch, support OSPF • Fan control interface
L3 switching
§ 12V power supply input
§ On-board power management
§ Hot pluggable

www.genew.com
AC/HVDC Power Supply – Off-the-shelf

§ 80 PLUS Certified “Platinum” Efficiency


§ Wide Input Voltage Range 90-264 VAC/230DVC, 550W
§ AC Input with Power Factor Correction
§ Always-On 24 W Standby Output (12 V/2 A)
§ Hot-Plug Capable
§ Parallel Operation with Active Digital Current Sharing
§ DC-DC Digital ContrGLS for Improved Performance
§ High Density Design 25 W/in3
§ Small Form Factor 73.5 x 39.0 x 185 mm
§ PMBus® for Control, Programming and Monitoring
§ Over Temperature, Output Over Voltage and Over Current
Protection
§ One DC OK Signaling Status LED
www.genew.com
OA-SWG / ILA-SWG
SN/PN/
Barcode

§ Both modules will be include 2x switchable-gain

OUT IN

OUT IN
amplifiers w\ OCM/OSC/OTDR STAT LINE SIG
OA-SWG

• 2x switchable gain amplifiers;


• BA Gain: 7~23dB/21~32, NF <6.5dB@15~32dB SN/PN/
Barcode

• PA Gain: 15~22dB/20~31, NF <6.5dB@15~31dB

OUT IN

OUT IN
• ILA is constructed with two PA STAT LINE A LINE B
ILA-SWG

• OTDR >30dB Dynamic range


• OCM flexible grid capable
LINE A LINE B
• IEC 60825-2 Compliance Laser Safety
• OA-SWG is used as pre-amp and booster amp.
• PA + BA with 1dB shift from gain range and power; LINE
• SIG Separate OCM function at each amplifier output;
• 2 port OTDR and 1x OSC on the line side;
• ILA-SWG is used as in-line power regeneration
• 2x amplifier for optical regeneration
• Separate OCM function at each amplifier output;
• 4 port OTDR and 2x OSC on each line side;
www.genew.com
OPS (Optical Protection Switch Module)
SN/PN/

§ OPS modules
Barcode

OUT IN

OUT IN

OUT IN
• 1x slot width and height; STAT A B SIG

• Three Duplex LC ports


OPS

• 50:50 Splitter for bridge and 1x2 switch select


between protection and working ports; A
• PD monitoring for each port and each SIG
direction; B
• FPGA Based Protection switch State machine
for fast switch
• Support end-to-end <50ms protection switch,
optical switch time <10ms
• Manual protection switch, auto protection
switch per threshold, power difference switch
criteria; www.genew.com
MUX-96

§ Passive Chassis M1

MUXDMUX (OUT)
M2

Interleaver
• 2RU Height, support 19” Rack
• 250mm depth, capable for both 600mm and 300mm depth rack installation
• 97 DLC ports (96x add/drop port, 1x Mux/Dmux port) M63
M96
• 1xRJ45 for 1-wire connection (connecting to the GLS chassis, rear side)
D1

Front view D2

Interleaver

MUXDMUX (IN)
D63
D96

Rear view Insertion Loss: <8dB (Mux), <8dB


(Dmux)
All DLC with dust shutter
Color coded Mux/Dmux direction
www.genew.com
MUX-64

§ Passive Chassis M1

• 2RU Height, support 19” Rack

MUXDMUX (OUT)
M2

Interleaver
• 250mm depth, capable for both 600mm and 300mm depth rack
installation M63

• 65 DLC ports (64x add/drop port, 1x Mux/Dmux port) M96

• 1xRJ45 for 1-wire connection (connecting to the GLS chassis, rear D1


D2
side)

Interleaver

MUXDMUX (IN)
Front view
D63
D96

Insertion Loss: <6dB (Mux),


Rear view <6.5dB (Dmux)
All DLC with dust shutter
Color coded Mux/Dmux direction

www.genew.com
Optical Line System Software Feature Example

§ Model neutral management framework design


• Netconf, WebGUI, CLI, gRPC (for Telemetry)
§ General optical service abstraction based on OpenConfig like model
§ Infrastructure of common functions for network element
• Equipment Management
• Security and User management
• Common service
• NTP, time
• Logging and the syslog for remote log function
• Software management
• Database
• Telemetry
§ L2/L3 Networking for common DCN management network application, OSPF dynamic routing
§ Local optical power control on degree power balance www.genew.com
Information Model

www.genew.com
module: openconfig-channel-monitor module: openconfig-interfaces

Interface +--rw channel-monitors +--rw interfaces


+--rw channel-monitor* [name] +--rw interface* [name]
+--rw config +--rw config
+--ro state +--ro state
+--rw channels | +--ro counters
| +--ro channel* [lower-frequency upper-frequency] +--rw hold-time
| +--ro state | +--rw config
+--ro waveform | +--ro state
module: openconfig-optical-amplifier +--rw channel-maps +--rw subinterfaces
+--rw optical-amplifier | +--rw channel-map* [index] | +--rw subinterface* [index]
+--rw amplifiers | +--rw config | +--rw config
| +--rw amplifier* [name] | +--ro state | +--ro state
| +--rw config | +--rw channels | | +--ro counters
| +--ro state | +--rw channel* [index] | +--rw oc-vlan:vlan
| | +--ro actual-gain | +--rw config | | +--rw oc-vlan:config
| | +--ro actual-gain-tilt | +--ro state | | +--ro oc-vlan:state
| | +--ro input-power-total +--ro specification | +--rw oc-ip:ipv4
| | +--ro input-power-c-band | | +--rw oc-ip:addresses
| | +--ro input-power-l-band | | | +--rw oc-ip:address* [ip]
| | +--rw| oc-ip:config
| +--ro output-power-total |
| | +--ro| oc-ip:state
| +--ro output-power-c-band |
| | +--rw| |oc-ip:vrrp
+--ro output-power-l-band module: openconfig-interfaces |
| | |+--rw
| oc-ip:vrrp-group* [virtual-router-id]
+--ro laser-bias-current +--rw oc-eth:ethernet |
| | | +--rw oc-ip:config
| +--ro optical-return-loss |
| +--rw oc-eth:config
| | +--ro specification
| +--ro oc-ip:state | +--ro oc-eth:state |
| | | +--rw oc-ip:interface-tracking
+--ro low-gain-range | | +--ro oc-eth:counters |
| | | +--rw+--rooc-ip:config
mid-gain-range | +--rw oc-vlan:switched-vlan |
| | | +--ro oc-ip:state
+--ro high-gain-range | | +--rw oc-vlan:config |
| +--rw oc-ip:proxy-arp
| +--ro fixed-gain-range | | | +--rw oc-vlan:trunk-vlans* union |
| | +--rw| oc-ip:config
+--ro gain-range | | +--ro oc-vlan:state |
| | +--ro| oc-ip:state
+--ro amp-mode | | +--ro oc-vlan:trunk-vlans* union |
| +--rw oc-ip:neighbors
+--rw supervisory-channels | +--rw oc-poe:poe |
| | +--rw oc-ip:neighbor* [ip]
+--rw supervisory-channel* [interface] | +--rw oc-poe:config |
| | +--rw oc-ip:config
+--rw config | +--ro oc-poe:state |
| | +--ro oc-ip:state
+--ro state +--rw oc-lag:aggregation |
| +--rw oc-ip:unnumbered
| +--ro input-power | +--rw oc-lag:config |
| | +--rw oc-ip:config
| +--ro output-power | +--ro oc-lag:state |
| | +--ro oc-ip:state
| +--ro laser-bias-current | | +--ro oc-lag:member* oc-if:base-interface-ref |
| | +--rw oc-ip:interface-ref
+--ro specification | +--rw oc-vlan:switched-vlan |
| | +--rw oc-ip:config | +--rw oc-vlan:config |
| | +--ro oc-ip:state | +--ro oc-vlan:state |
www.genew.com
Optical/ platform module: openconfig-otdr-monitor
+--rw otdr-monitors
module: openconfig-transport-line-protection
+--rw aps
+--rw otdr-monitor* [name] +--rw aps-modules
+--rw config +--rw aps-module* [name]
module: openconfig-platform
+--ro state +--rw config
+--rw components +--ro results +--ro state
+--rw component* [name] +--ro result* [result-id] +--rw ports
+--rw config
+--ro events | +--rw line-primary
+--ro state | +--ro event* [index] | | +--rw config
| +--ro input-current
+--ro waveform | | +--ro state
| +--ro input-voltage | | +--ro input-power
| +--ro temperature
rpcs: | | +--ro output-power
| +--ro memory +---x start-otdr | +--rw line-secondary
+--rw properties +---w input | | +--rw config
| +--rw property* [name] +--ro output | | +--ro state
| +--rw config | | +--ro input-power
| +--ro state | | +--ro output-power
+--rw subcomponents | +--rw common-sig
| +--rw subcomponent* [name] | +--rw config
module: openconfig-wavelength-router
| +--rw config | +--ro state
+--rw wavelength-router
| +--ro state | +--ro input-power
+--rw media-channels
+--rw chassis | +--ro output-power
+--rw channel* [index]
| +--rw config +--ro specification
+--rw config
| +--ro state
+--ro state
+--rw port
+--rw source
| +--rw config
| +--rw config
| +--ro state
| +--ro state
| +--rw oc-port:breakout-mode +--rw dest
| +--rw oc-port:config
| +--rw config
| +--ro oc-port:state
| +--ro state
+--rw power-supply +--rw psd-distribution
| +--rw config
+--rw psd-value* [lower-frequency upper-frequency]
| +--ro state +--rw config
| | +--ro oc-platform-psu:output-current +--ro state
| | +--ro oc-platform-psu:output-voltage
| +--ro specification rpcs:
| +--ro ac
+---x create-optical-xc
| +--ro dc | +---w input
+--rw fan
| +--ro output
| +--rw config +---x delete-optical-xc
| +--ro state
+---w input
| +--ro specification
+--ro output www.genew.com
| +--ro speed-grade
Platform/Telemetry module: openconfig-platform
+--rw fabric module: openconfig-platform
| +--rw config +--rw oc-linecard:linecard
| +--ro state | +--rw oc-linecard:config
+--rw storage | +--ro oc-linecard:state
| +--rw config | +--ro oc-linecard:specification
| +--ro state +--rw oc-panel:panel
+--rw cpu | +--rw oc-panel:config
module: openconfig-telemetry | +--ro oc-panel:state
+--rw telemetry-system | +--rw config
| +--ro state | +--ro oc-panel:specification
+--rw sensor-groups +--rw oc-line-com:optical-port
| +--rw sensor-group* [sensor-group-id] | +--rw oc-cpu:utilization
| +--ro oc-cpu:state +--rw oc-line-com:config
| +--rw config +--ro oc-line-com:state
| +--ro state +--rw integrated-circuit
| +--rw config +--ro oc-line-com:input-power
| +--rw sensor-paths +--ro oc-line-com:output-power
| +--rw sensor-path* [path] | +--ro state
| +--rw config +--rw backplane
| +--rw config module: openconfig-platform-phycon
| +--ro state +--rw connections
+--rw destination-groups | +--ro state
+--rw oc-transceiver:transceiver +--rw external-connection* [name]
| +--rw destination-group* [group-id] | +--rw config
| +--rw config | +--rw oc-transceiver:config
| +--ro oc-transceiver:state | +--ro state
| +--ro state +--rw internal-connection* [name]
| +--rw destinations | | +--ro oc-transceiver:pre-fec-ber
| | +--ro oc-transceiver:post-fec-ber +--rw config
| +--rw destination* [destination-address +--ro state
destination-port] | | +--ro oc-transceiver:output-power
| | +--ro oc-transceiver:input-power module: openconfig-platform-phycon
| +--rw config +--rw connections
| | +--ro oc-transceiver:laser-bias-current
| +--ro state +--rw external-connection* [name]
| +--ro oc-transceiver:specification
+--rw subscriptions | +--rw config
| +--rw oc-transceiver:physical-channels
+--rw persistent | +--ro state
| +--rw oc-transceiver:channel* [index]
| +--rw subscription* [subscription-name] +--rw internal-connection* [name]
| +--rw config | +--rw oc-transceiver:config
| +--ro oc-transceiver:state +--rw config
| +--ro state +--ro state
| +--ro oc-transceiver:output-power
| +--rw sensor-profiles module: openconfig-platform-panel
| +--ro oc-transceiver:input-power
| | +--rw sensor-profile* [sensor-group]
| +--ro oc-transceiver:laser-bias-current
| | +--rw config rpcs:
+--rw oc-platform-mux:mux
| | +--ro state +---x light-screen
| +--rw oc-platform-mux:config
| +--rw destination-groups | +---w input
| +--ro oc-platform-mux:state
| +--rw destination-group* [group-id] | +--ro output
+--rw oc-cu:cu
| +--rw config +---x reboot-panel
| +--rw oc-cu:config
| +--ro state +---w input
| +--ro oc-cu:state
| +--ro oc-cu:specification +--ro output
www.genew.com
module: openconfig-system module: openconfig-system module: openconfig-system
System +--rw system
+--rw config
| +--rw remote-servers
| +--rw remote-server* [host]
| +--rw server-groups
| +--rw server-group* [name]
+--ro state | +--rw config | +--rw config
+--rw clock | +--ro state | +--ro state
| +--rw config | +--rw selectors | +--rw servers
| +--ro state | +--rw selector* [facility severity] | +--rw server* [address]
+--rw dns | +--rw config | +--rw config
| +--rw config | +--ro state | +--ro state
module: openconfig-system | +--ro state +--rw aaa | +--rw tacacs
+--rw software | +--rw servers | +--rw config | | +--rw config
+--ro state | | +--rw server* [address] | +--ro state | | +--ro state
+--rw upgrade | | +--rw config | +--rw authentication | +--rw radius
| +--ro state | | +--ro state | | +--rw config | +--rw config
+--rw download | +--rw host-entries | | +--ro state | +--ro state
+--ro state | | +--rw admin-user | +--ro counters
| +--rw host-entry* [hostname]
| +--rw config | | | +--rw config +--rw memory
rpcs: | | | +--ro state
| +--ro state | +--rw config
+---x set-datetime +--rw ntp | | +--rw users | +--ro state
| +---w input | | +--rw user* [username]
| +--rw config +--ro cpus
| +--ro output
| +--ro state | | +--rw config | +--ro cpu* [index]
+---x reboot
| +--rw ntp-keys | | +--ro state | +--ro state
| +---w input | +--rw authorization
| | +--rw ntp-key* [key-id] | +--ro total
| +--ro output | | +--rw config
| | +--rw config | +--ro user
+---x stream-history-pm
| | +--ro state | | +--ro state | +--ro kernel
+---w input | | +--rw events
| +--rw servers | +--ro nice
+--ro output
| +--rw server* [address] | | +--rw event* [event-type] | +--ro idle
| +--rw config | | +--rw config | +--ro wait
module: openconfig-software | +--ro state | | +--ro state | +--ro hardware-interrupt
+--rw ssh-server | +--rw accounting | +--ro software-interrupt
rpcs: | +--rw config | | +--rw config +--rw processes
| +--ro state | | +--ro state | +--ro process* [pid]
+---x database-operate | | +--rw events
+--rw telnet-server | +--ro state
| +---w input
| +--rw config | | +--rw event* [event-type] +--ro alarms
| | +---w sftp-server | | +--rw config
| +--ro output | +--ro state | +--ro alarm* [id]
+--rw logging | | +--ro state | +--ro config
+---x software-operate
| +--rw console | +--ro state
+---w input
| | +--rw config +--rw database
| +---w sftp-server
| | +--ro state | +--ro state
+--ro output
| | +--rw selectors | +--rw backup
| | +--rw selector* [facility severity] | | +--ro state
| | +--rw config | +--rw restore
| +--ro state
www.genew.com
| | +--ro state
Optical Protection

+--rw aps
+--rw aps-modules
+--rw aps-module* [name]
+--rw name -> ../config/name
+--rw config
| +--rw name? string
§ Support Revertive and non-Revertive mode
| +--rw revertive?
| +--rw wait-to-restore-time?
boolean
uint32
§ Support WTR
| +--rw hold-off-time? uint32
| +--rw primary-switch-threshold? decimal64 § Support hold off
| +--rw primary-switch-hysteresis? decimal64
| +--rw secondary-switch-threshold?
| +--rw aps-mode?
decimal64
aps-mode-type
§ Support absolute threshold or relative threshold (aps-mode)
| +--rw relative-switch-threshold? decimal64
| +--rw relative-switch-threshold-offset? decimal64 § Support external command on switch
| +--rw force-to-port? enumeration
+--ro state • Force
| +--ro name? string
| +--ro revertive? boolean • manual
| +--ro wait-to-restore-time? uint32
| +--ro hold-off-time? uint32
| +--ro primary-switch-threshold? decimal64
| +--ro primary-switch-hysteresis? decimal64
| +--ro secondary-switch-threshold? decimal64
| +--ro aps-mode? aps-mode-type
| +--ro relative-switch-threshold? decimal64
| +--ro relative-switch-threshold-offset? decimal64
| +--ro force-to-port? enumeration
| +--ro active-path? identityref
| +--ro component? -> /oc-
platform:components/component/name

www.genew.com
Telemetry

§ The GLS system support dial-out telemetry for PM and status data streaming out
§ Supported data:
• PM data with 1s interval
• Key status update with 1s interval
• History PM (15-min, 24h) Telemetry collector
Controller

NETCONF (first): gRPC (dial-out):


Controller firstly configure NE streaming the data
sensor, collector server through gRPC interface

SAT /AMT
LOGO S N /P N /
B arco d e
S N /P N /
B arco d e
Slot 1

OUT IN

OUT IN

Slot 2
IP:172.120.10.10

STA T L IN E SIG

OA-SWG BLANK

U SB Button S N /P N /
S N /P N /
B arco d e B arco d e
Slot 3 Slot 40

Slot 4
OUT IN

OUT IN

OUT IN
OUT IN

OUT IN
ETH CON

STA T L IN E SIG STA T A B SIG

PANEL OA-SWG OPS

www.genew.com
2x400G Muxponder
4xCAUI-4, NRZ 4x100GAUI-2, PAM4
C1 QSFP28

CFP2-DCO
Gearbox
C2 QSFP28
100GE C3 QSFP28 L1
LR4, SR4, CWDM4 (first C4 QSFP28 DP-16QAM 400G
Phase) DP-QPSK 200G
DR1, PSM4, AOC, ER4… (HW C5 SD-FEC
QSFP28

CFP2-DCO
ready) C-FEC
C6 QSFP28

Gearbox
C7 QSFP28 L2 …
C8 QSFP28
4xCAUI-4, NRZ 4x100GAUI-2, PAM4

www.genew.com
Colorless WSS Add/drop
– Colorless Flexigrid MuxDemux CMUX-64
• Highlight
• Colorless and flexible grid, future-proofdesign
• Leverage coherent interface datarate tunability to optimizing
the balance of spectrum efficiency and transmission distance
• Hardware Overview
• Two slot width
• 2xTwin WSS32
• Integrated 1+1 OPS unit for OMS protection
• 66 optical ports:
• LC Ports A and B on line
• 64 MPO add/drop optical ports (8x MPO24)
64 add/drop ports
(8 MPO24, each MPO • Support 64 colorless add/drop
8 add/drop ports) • Optical monitoring on ports A, B in/out, output of WSS
aggregation ports, and drop side after optical switch
• Reuse OPS PCB and most PCBA with different optical
• Optical BOM
• Datapath Insertion Loss
• 64 channels w/ protection
www.genew.com