INSTALLATION REQUIREMENTS

Inferno GC
Electrical Gas
Power Requirements: Natural Gas, or Propane
120 Volts, 12 Amps 60Hz Gas Consumption:
Plug Type: 68,000 BTU (71.7 MJ)/ Hour Max.* Natural
NEMA 5-15 sockets are required. (One for each 71,000 BTU (74.9 MJ)/ Hour Max.* Propane
rotisserie and one for the heated grease collection Recommended Gas Pressure Natural Gas:
reservoir, if purchased). 7” Water Column (17.5 mbar) Inlet
Proximity: Recommended Gas Pressure Propane:
The plug must be within 6ft (183 cm) of the cord on the 11” Water Column (27.5 mbar) Inlet
lower rear right corner of the rotisserie. Maximum Gas Pressure (Propane & Natural):
12” Water Column (29.9 mbar) Inlet – Non-fluctuating.
The appliance must be electrically grounded in Gas Connection: ¾ NPT male
accordance with local codes or in the absence of local Proximity:
codes, with the National Electrical Code, ANSI/NFPA 70 The gas supply fitting must be within 3ft (91 cm) and the
or by the Canadian Electrical Code CSA C22.2 as gas shut off must be within 4ft (122 cm) of the lower
applicable. right rear corner of the rotisserie.
Water The shut off must be located in an accessible location.
Restrainer:
Pressure: All rotisseries equipped with casters must be equipped
30 – 60 PSI (2.1-4.1 bar) at inlet (Equipped with with a restraining cable and a quick disconnect device.
regulator)
Water Quality: * As indicated on the serial plate, located at the back of
Hardness not to exceed 4 GPG (70 PPM) the rotisserie. The gas consumption varies with rotisserie
Water Connection: set-up. Consult Hardt for assistance in optimizing for your
A direct connection to a permanent HOT water supply is application.
required. A backflow prevention device may be
required by your local regulations.
Water Connection Proximity:
Ventilation
The water supply fitting must be within 3ft (91 cm) of the Hood: Type 1 / Class A grease hood with filters and
gas fitting on lower rear right corner of the rotisserie. equipped with a fire suppression system.
Water Fitting:
½” NPT Hardt recommends a 6”– 12” (15 cm – 31 cm) minimum
Drain overhang canopy of the hood on the sides and front of the
rotisserie (this may vary as per local code).
Make sure that the AutoClean drain is plumbed in a
manner which allows the rotisserie to remain mobile for The hood should remove the exhaust gases without
servicing. The effluent from this drain may contain Fats, disturbing the air within the rotisserie.
Oils and Greases (FOGs).
Local regulation may require a backflow prevention device Ensure that the fire suppression nozzles do not prevent
and special methods for disposing of grease laden water the rotisserie from being moved.
and FOGs. Consult local authorities to determine what
regulations are in force for appliances of this type. An adequate air supply must be supplied to the unit at all
The 1” AutoClean drain lines from double deck times during operation to ensure proper flow of
rotisseries must NEVER be plumbed together. Doing combustion and ventilation air.
so will cause improper drainage performance and will
lead to other plumbing problems.
Weight
Environment
Single Unit: 750 lbs (340 kg) approx.
Inferno_GC_Inst_Requirements_(2013-03-21).doc

The environment around the appliance must be kept free Double Deck: 1450 lbs (658 kg) approx.
from any combustible material; the floor must not be made
of combustible material.
Do not locate the rotisserie in an area where the control
side is next to fryers, broilers or other appliances that emit
grease, smoke, humidity, flour, etc.
The rotisserie must be installed in a draft-free area where
temperatures are above 45 degrees Fahrenheit (7
degrees Celsius).

Page 1 of 2
INSTALLATION REQUIREMENTS
Inferno GC
Size & Clearance

Double Deck Unit Size

Unpacked & Assembled:

Width With Plumbing: 61 ½” (156.21 cm) 61 57


4
Without Plumbing: 51 1/8” (129.86 cm) 2”
Depth With Chimney: 57 3/8” (145.73 cm)
Without Chimney: 44 ½“ (113.03 cm)

Height With Chimney: 103 ½“ (262.89 cm)


Without Chimney: 85 3/8” (216.85 cm) 85 103

Packed (In the shipping crate):

Width TBD

Depth TBD

Height TBD

Single Deck Unit Size

Unpacked & Assembled:

Width With Plumbing: 61 ½” (156.21 cm) 61 57


Without Plumbing: 51 1/8” (129.86 cm) 4
2”
Depth With Chimney: 57 3/8” (145.73 cm)
Without Chimney: 44 ½“ (113.03 cm)
Top Vent Config: 44 ½“ (113.03 cm)

Height With Chimney: 90” (228.60 cm) 9


Without Chimney: 72” (182.88 cm) 7
Top Vent Config: 73 3/8” (185.74 cm)

Packed (In the shipping crate):

Width TBD

Depth TBD

Height TBD

Only single deck rotisseries can have the top vent configuration. Instead of having a chimney stack
as shown in the illustration above; the chimney protrudes from the top of the top vent rotisseries by
1 3/8” (2.86 cm).
Inferno_GC_Inst_Requirements_(2013-03-

Clearance

Right Side Left Side Front Rear


21).doc

12” (305 mm) 2” (51 mm) 44” (1118 mm) 2” (51 mm)
(Required for service) (For door opening) (From vent)

Page 2 of 2