Produced on 5/25/2022 with Xpress Selection V9.8.0 - database DIL 17.2.

Project name BRI SUDIRMAN


Project address Indonesia
Reference ---
Client name ---
Revision 00

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Type Model Name Qty Description
Outdoor unit RXQ20AMY14 1 Cooling only VRV A(18,20HP multi module)ID
RXQ26AMY14 1 Cooling only VRV A(18,20HP multi module)ID
RXQ36AMY14 1 Cooling only VRV A(18,20HP multi module)ID
Indoor unit FXAQ25AVM4 7 VRV A(AVM4) - Wall Mounted
FXAQ32AVM4 3 VRV A(AVM4) - Wall Mounted
FXMQ140PAV4 13 VRV M-PA(ID) - Ceiling Mounted Duct
Branch unit BHFP22P100 3 Outdoor unit multi connection piping kit
KHRP26A22T 3 Refnet branch piping kit
KHRP26A33T 4 Refnet branch piping kit
KHRP26A72T 11 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 2 Refnet branch piping kit
Option or add-on BRC1E63 23 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 46.8kg Extra refrigerant charge
Copper pipe Piping ø 6.4 84.0m Soft copper pipe
Piping ø 9.5 163.0m Soft copper pipe
Piping ø 12.7 96.5m Soft copper pipe
Piping ø 15.9 203.5m Soft copper pipe
Piping ø 19.1 69.0m Hard copper pipe
Piping ø 22.2 18.0m Hard copper pipe
Piping ø 28.6 75.0m Hard copper pipe
Piping ø 34.9 30.0m Hard copper pipe
Piping ø 41.3 35.0m Hard copper pipe

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / wet bulb temp.)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Tmp H Indoor temperature in heating
Rq HC Required heating capacity
Max HC Available heating capacity
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
2
2.2. OU.L1 - RXQ36AMY14
Capacity data at conditions and connection ratio (97%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tmp H Rq HC Max HC Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C BTU/h BTU/h l/s
IU.01 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.02 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.03 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.04 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.05 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.06 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.07 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.08 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.09 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.10 FXAQ25AVM4 27.0 / 19.0 n/a 9554 n/a 7507 Auto n/a n/a n/a 157
IU.11 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.12 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767

Required cooling capacity towards the outdoor unit: 339849BTU/h.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
IU.01 43-46 220V 1ph 3.4 1400×300×700 46
IU.02 43-46 220V 1ph 3.4 1400×300×700 46
IU.03 43-46 220V 1ph 3.4 1400×300×700 46
IU.04 28.5-35 220V 1ph 0.6 795×290×266 12
IU.05 28.5-35 220V 1ph 0.6 795×290×266 12
IU.06 28.5-35 220V 1ph 0.6 795×290×266 12
IU.07 28.5-35 220V 1ph 0.6 795×290×266 12
IU.08 28.5-35 220V 1ph 0.6 795×290×266 12
IU.09 28.5-35 220V 1ph 0.6 795×290×266 12
IU.10 28.5-35 220V 1ph 0.6 795×290×266 12
IU.11 43-46 220V 1ph 3.4 1400×300×700 46
IU.12 43-46 220V 1ph 3.4 1400×300×700 46

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
3
2.3. OU.L2 - RXQ26AMY14
Capacity data at conditions and connection ratio (96%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tmp H Rq HC Max HC Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C BTU/h BTU/h l/s
IU.01 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.02 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.03 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.04 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.05 FXAQ32AVM4 27.0 / 19.0 n/a 12284 n/a 8872 Auto n/a n/a n/a 163
IU.06 FXAQ32AVM4 27.0 / 19.0 n/a 12284 n/a 8872 Auto n/a n/a n/a 163

Required cooling capacity towards the outdoor unit: 242945BTU/h.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
IU.01 43-46 220V 1ph 3.4 1400×300×700 46
IU.02 43-46 220V 1ph 3.4 1400×300×700 46
IU.03 43-46 220V 1ph 3.4 1400×300×700 46
IU.04 43-46 220V 1ph 3.4 1400×300×700 46
IU.05 28.5-37.5 220V 1ph 0.6 795×290×266 12
IU.06 28.5-37.5 220V 1ph 0.6 795×290×266 12

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
4
2.4. OU.L3 - RXQ20AMY14
Capacity data at conditions and connection ratio (118%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tmp H Rq HC Max HC Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C BTU/h BTU/h l/s
IU.01 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.02 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.03 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.04 FXMQ140PAV4 27.0 / 19.0 n/a 54594 n/a 40946 Auto n/a n/a n/a 767
IU.05 FXAQ32AVM4 27.0 / 19.0 n/a 12284 n/a 8872 Auto n/a n/a n/a 163

Required cooling capacity towards the outdoor unit: 230661BTU/h.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
IU.01 43-46 220V 1ph 3.4 1400×300×700 46
IU.02 43-46 220V 1ph 3.4 1400×300×700 46
IU.03 43-46 220V 1ph 3.4 1400×300×700 46
IU.04 43-46 220V 1ph 3.4 1400×300×700 46
IU.05 28.5-37.5 220V 1ph 0.6 795×290×266 12

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
5
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / wet bulb temp.)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
6
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC
% °C BTU/h BTU/h °C BTU/h BTU/h
OU.L1 RXQ36AMY14 ▼ 97 35.0 310019 (-8.8%) 339849
OU.L2 RXQ26AMY14 ▼ 96 35.0 217944 (-10.3%) 242945
OU.L3 RXQ20AMY14 ▼ 118 35.0 176824 (-23.3%) 230661
Name Model Piping Refrigerant
m Type Bse Refr Ex Refr
kg kg
OU.L1 RXQ36AMY14 74.4 R410A 16.8 18.6
OU.L2 RXQ26AMY14 75.6 R410A 14.2 15.8
OU.L3 RXQ20AMY14 58.5 R410A 12.7 12.4
Name Model PS MCA WxHxD Wght
A mm kg
OU.L1 RXQ36AMY14 400V 3ph
× RXQ18AY14 30.2 1240×1657×765 260
× RXQ18AY14 30.2 1240×1657×765 260
OU.L2 RXQ26AMY14 400V 3ph
× RXQ14AY14 26.9 1240×1657×765 215
× RXQ12AY14 22.5 930×1657×765 185
OU.L3 RXQ20AMY14 400V 3ph
× RXQ12AY14 22.5 930×1657×765 185
× RXQ8AY14 16.1 930×1657×765 175

Sufficient distance should be respected between the modules according to the service & operation space rules as mentioned in
the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
7
3.2.1. OU.L1 - RXQ36AMY14

Model Type Model Name Qty Description


Outdoor unit RXQ36AMY14 1 Cooling only VRV A(18,20HP multi module)ID
Indoor unit FXAQ25AVM4 7 VRV A(AVM4) - Wall Mounted
FXMQ140PAV4 5 VRV M-PA(ID) - Ceiling Mounted Duct
Branch unit BHFP22P100 1 Outdoor unit multi connection piping kit
KHRP26A22T 2 Refnet branch piping kit
KHRP26A33T 2 Refnet branch piping kit
KHRP26A72T 6 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 1 Refnet branch piping kit
Option or add-on BRC1E63 12 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 18.6kg Extra refrigerant charge
Copper pipe Piping ø 6.4 57.0m Soft copper pipe
Piping ø 9.5 56.5m Soft copper pipe
Piping ø 12.7 68.0m Soft copper pipe
Piping ø 15.9 49.5m Soft copper pipe
Piping ø 19.1 39.0m Hard copper pipe
Piping ø 22.2 13.5m Hard copper pipe
Piping ø 28.6 21.5m Hard copper pipe
Piping ø 41.3 35.0m Hard copper pipe

Standard factory refrigerant charge (5m actual piping length) = 16.8kg


Extra refrigerant charge = 56.5m(ø9.5) × 0.057 + 57.0m(ø6.4) × 0.022 + 35.0m(ø19.1) × 0.26 + 10.5m(ø15.9) × 0.17 +
11.0m(ø12.7) × 0.11 + A + B = 18.6kg
A [ CR 97%, actual length 67.5m ] = 2.0kg
B [ 36HP ] = 0.0kg

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
8
3.2.2. OU.L2 - RXQ26AMY14

Model Type Model Name Qty Description


Outdoor unit RXQ26AMY14 1 Cooling only VRV A(18,20HP multi module)ID
Indoor unit FXAQ32AVM4 2 VRV A(AVM4) - Wall Mounted
FXMQ140PAV4 4 VRV M-PA(ID) - Ceiling Mounted Duct
Branch unit BHFP22P100 1 Outdoor unit multi connection piping kit
KHRP26A22T 1 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
KHRP26A72T 2 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 1 Refnet branch piping kit
Option or add-on BRC1E63 6 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 15.8kg Extra refrigerant charge
Copper pipe Piping ø 6.4 11.0m Soft copper pipe
Piping ø 9.5 56.0m Soft copper pipe
Piping ø 12.7 11.0m Soft copper pipe
Piping ø 15.9 68.0m Soft copper pipe
Piping ø 19.1 30.0m Hard copper pipe
Piping ø 22.2 3.0m Hard copper pipe
Piping ø 28.6 15.0m Hard copper pipe
Piping ø 34.9 30.0m Hard copper pipe

Standard factory refrigerant charge (5m actual piping length) = 14.2kg


Extra refrigerant charge = 56.0m(ø9.5) × 0.057 + 11.0m(ø6.4) × 0.022 + 30.0m(ø19.1) × 0.26 + 15.0m(ø15.9) × 0.17 + A + B =
15.8kg
A [ CR 96%, actual length 69.0m ] = 2.0kg
B [ 26HP ] = 0.0kg

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
9
3.2.3. OU.L3 - RXQ20AMY14

Model Type Model Name Qty Description


Outdoor unit RXQ20AMY14 1 Cooling only VRV A(18,20HP multi module)ID
Indoor unit FXAQ32AVM4 1 VRV A(AVM4) - Wall Mounted
FXMQ140PAV4 4 VRV M-PA(ID) - Ceiling Mounted Duct
Branch unit BHFP22P100 1 Outdoor unit multi connection piping kit
KHRP26A33T 1 Refnet branch piping kit
KHRP26A72T 3 Refnet branch piping kit
Option or add-on BRC1E63 5 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 12.4kg Extra refrigerant charge
Copper pipe Piping ø 6.4 16.0m Soft copper pipe
Piping ø 9.5 50.5m Soft copper pipe
Piping ø 12.7 17.5m Soft copper pipe
Piping ø 15.9 86.0m Soft copper pipe
Piping ø 22.2 1.5m Hard copper pipe
Piping ø 28.6 38.5m Hard copper pipe

Standard factory refrigerant charge (5m actual piping length) = 12.7kg


Extra refrigerant charge = 50.5m(ø9.5) × 0.057 + 37.0m(ø15.9) × 0.17 + 16.0m(ø6.4) × 0.022 + 1.5m(ø12.7) × 0.11 + A + B =
12.4kg
A [ CR 118%, actual length 54.5m ] = 2.7kg
B [ 20HP ] = 0.0kg

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
10
4. Piping Diagrams
Pipes marked with a short red stripe in the diagrams must be connected to the device with a reducing joint.

4.1. Piping OU.L1


OU.L1
RXQ36AMY14
RXQ18AY14 RXQ18AY14

15.9×28.6 15.9×28.6
BHFP22P100

35.0m [4] 1.5m 7.0m [2] 12.0m [1] 12.0m [2]


19.1×41.3 15.9×28.6 15.9×28.6 9.5×22.2 9.5×15.9
KHRP26A73T + KHRP26A72T KHRP26A72T KHRP26A33T
KHRP26M73TP
IU.01
FXMQ140PAV4
8.0m [2]
9.5×15.9

IU.03
FXMQ140PAV4
8.0m [1]
9.5×15.9

IU.12
FXMQ140PAV4
9.0m [1]
6.4×12.7

IU.10
FXAQ25AVM4
2.0m [1] 3.0m 4.0m [1] 4.0m 1.5m 1.5m 2.5m 5.0m [2]
15.9×28.6 12.7×28.6 12.7×28.6 12.7×28.6 9.5×22.2 9.5×19.1 9.5×19.1 9.5×15.9
KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A33T KHRP26A22T KHRP26A22T

IU.02
FXMQ140PAV4
12.0m [2]
6.4×12.7

IU.04
FXAQ25AVM4
7.0m [2]
6.4×12.7

IU.06
FXAQ25AVM4
10.0m [2]
6.4×12.7

IU.05
FXAQ25AVM4
6.0m [1]
9.5×15.9

IU.11
FXMQ140PAV4
7.0m [2]
6.4×12.7

IU.07
FXAQ25AVM4
7.0m [2]
6.4×12.7

IU.08
FXAQ25AVM4
5.0m [2]
6.4×12.7

IU.09
FXAQ25AVM4

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
11
4.2. Piping OU.L2

OU.L2
RXQ26AMY14
RXQ14AY14 RXQ12AY14

12.7×28.6 12.7×28.6
BHFP22P100

30.0m [4] 10.0m [2] 5.0m 3.0m [1] 21.0m [3]


19.1×34.9 15.9×28.6 15.9×28.6 9.5×22.2 9.5×15.9
KHRP26A73T + KHRP26A72T KHRP26A72T KHRP26A33T
KHRP26M73TP
IU.01
FXMQ140PAV4
5.0m [2]
9.5×15.9

IU.02
FXMQ140PAV4
8.0m [1]
9.5×15.9

IU.04
FXMQ140PAV4
14.0m [2]
9.5×15.9

IU.03
FXMQ140PAV4
5.0m [1] 5.0m [2]
9.5×15.9 6.4×12.7
KHRP26A22T

IU.05
FXAQ32AVM4
6.0m [2]
6.4×12.7

IU.06
FXAQ32AVM4

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
12
4.3. Piping OU.L3

OU.L3
RXQ20AMY14
RXQ12AY14 RXQ8AY14

12.7×28.6 9.5×19.1
BHFP22P100

35.0m [4] 2.0m 1.5m 1.5m 11.0m [2]


15.9×28.6 15.9×28.6 12.7×28.6 9.5×22.2 9.5×15.9
KHRP26A72T KHRP26A72T KHRP26A72T KHRP26A33T

IU.01
FXMQ140PAV4
14.0m [2]
9.5×15.9

IU.03
FXMQ140PAV4
16.0m [2]
6.4×12.7

IU.05
FXAQ32AVM4
17.0m [2]
9.5×15.9

IU.04
FXMQ140PAV4
7.0m [2]
9.5×15.9

IU.02
FXMQ140PAV4

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
13
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring OU.L1


P1,P2
OU.L1
IU.01 BRC1E63
RXQ36AMY14
FXMQ140PAV4
IN F1,F2 F1,F2
RXQ18AY14 L,N 3.4A 1ph
Q1,Q2 L1,L2,L3,N P1,P2
30.2A 3ph IU.03 BRC1E63
FXMQ140PAV4
RXQ18AY14 F1,F2
Q1,Q2 L1,L2,L3,N L,N 3.4A 1ph
30.2A 3ph P1,P2
IU.12 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.10 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.02 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.04 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.06 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.05 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.11 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.07 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.08 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.09 BRC1E63
FXAQ25AVM4
F1,F2
L,N 0.6A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
14
5.2. Wiring OU.L2
P1,P2
OU.L2
IU.01 BRC1E63
RXQ26AMY14
FXMQ140PAV4
IN F1,F2 F1,F2
RXQ14AY14 L,N 3.4A 1ph
Q1,Q2 L1,L2,L3,N P1,P2
26.9A 3ph IU.02 BRC1E63
FXMQ140PAV4
RXQ12AY14 F1,F2
Q1,Q2 L1,L2,L3,N L,N 3.4A 1ph
22.5A 3ph P1,P2
IU.04 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.03 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.05 BRC1E63
FXAQ32AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.06 BRC1E63
FXAQ32AVM4
F1,F2
L,N 0.6A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
15
5.3. Wiring OU.L3
P1,P2
OU.L3
IU.01 BRC1E63
RXQ20AMY14
FXMQ140PAV4
IN F1,F2 F1,F2
RXQ12AY14 L,N 3.4A 1ph
Q1,Q2 L1,L2,L3,N P1,P2
22.5A 3ph IU.03 BRC1E63
FXMQ140PAV4
RXQ8AY14 F1,F2
Q1,Q2 L1,L2,L3,N L,N 3.4A 1ph
16.1A 3ph P1,P2
IU.05 BRC1E63
FXAQ32AVM4
F1,F2
L,N 0.6A 1ph
P1,P2
IU.04 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph
P1,P2
IU.02 BRC1E63
FXMQ140PAV4
F1,F2
L,N 3.4A 1ph

F1F2 IN/OUT transmission wiring, use 2-core wires of 0,75 to 1,25 mm² size cables, without shield (but shielded cable can be
used if local regulation prescribes it)
Note: The shield should only be earthed at outdoor unit side, not at the indoor units!

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.
16
6. Device Options
6.1. Outdoor Unit Options
Model Description Used by
BHFP22P100 Outdoor unit multi connection piping kit OU.L1 [RXQ36AMY14] OU.L3 [RXQ20AMY14] OU.L2 [RXQ26AMY14]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection Program.