STG2

Response is MP Extraction Flow


3700 cases used, 28 cases contain missing values

L
P
S 2
t E C
e x o
a t n
m r d
a e
I c n
n t s
l i a
e o t
t n e

F F F
l l l
R-Sq R-Sq o o o
Vars R-Sq (adj) (pred) Mallows Cp Sw w w
1 66.6 66.6 66.5 3660.5 3.7621 X
1 20.8 20.8 20.7 13747.3 5.7931 X
2 78.3 78.3 78.2 1092.7 3.0351 X X
2 68.3 68.3 68.2 3286.1 3.6651 X X
3 83.2 83.2 83.1 4.0 2.6674 X X X

Regression Equation
MP Extraction Flow = -31.238 + 0.96652 Steam Inlet Flow - 0.6085 LP2 Extraction Flow
- 0.4975 Condensate Flow

Model Summary
S R-sq R-sq(adj) R-sq(pred)
2.66735 83.23% 83.21% 83.15%
STG3
Response is MP Extraction Flow
3591 cases used, 243 cases contain missing values

L
P
S 1
t E C
e x o
a t n
m r d
a e
I c n
n t s
l i a
e o t
t n e

F F F
l l l
R-Sq R-Sq o o o
Vars R-Sq (adj) (pred) Mallows Cp Sw w w
1 52.3 52.3 52.2 2007.3 3.5050 X
1 36.9 36.9 36.8 3806.8 4.0295 X
2 54.6 54.6 54.6 1730.4 3.4170 X X
2 53.4 53.4 53.3 1878.4 3.4642 X X
3 69.4 69.4 69.3 4.0 2.8074 X X X

Regression Equation
MP Extraction Flow = -2.047 + 0.46905 Steam Inlet Flow - 0.38542 LP1 Extraction Flow
- 0.37652 Condensing Flow (NEW)

Model Summary
S R-sq R-sq(adj) R-sq(pred)
2.80739 69.40% 69.37% 69.32%