Professional Documents
Culture Documents
Sho001 Nap Ifc M2 06 RCM DR SS 3003 03 0a
Sho001 Nap Ifc M2 06 RCM DR SS 3003 03 0a
h
o
m
o
u
l
S
ﺷﻣﻭﻝ
CC DD EE FF GG HH II JJ KK LL MM NN
9250 9250 9250 9250 9250 9250 9250 9250 9250 9250 9250
FOR SECTION REFER TO DWG:
350 SHOMOUL HOLDING COMPANY W.L.L.
SHO001-NAP-IFC-M2-05-XX-DR-SS-3004-04 450
Project Management:
HEA 200 HEA 200 HEA 200 HEB 400
2L100x10x10
2L
Riyadh-King Fahad Road
0
2L
0
2L
0
2L
0
2L
2L
2L70x7x10
0
1
2L80x8x10
x1
1
x1
x1
10
HEA 140
x1
9x
90
80
58729 Riyadh, 11414 Saudi Arabia
9x
90
80
90
x9
x9
x8
0x
HEB 240
x8
x
x
x8
x
x8
x9
90
90
90
80
90
9x
9x
10
80
3479
3479
x1
x1
x1
2L
2L
10
2L
2L
2L
10
x1
2L
0
0
0
0
HEA 180 HEA 180 B4 Prime Consultant:
+33.000
C.L. Al Zaid Engineering
AL - ZAID ﺍﻟﺰﻳﺪ
E
Consultants (ZEC)
C
Z
ENGINEERING P.O. Box 20179 Riyadh 11455, KSA
CONSULTANTS ﻟﻺﺳﺗﺷﺎﺭﺍﺕ ﺍﻟﻬﻧﺩﺳﻳﺔ
Riyadh, KSA
Lead Consultant:
D D SHAREKAT ALMOHANEDSOON
ALISTESHAREYOON WE SHARIKOH
LEISTESHARAT ALHANDASEYA
C O N S U L T I N G E N G I N E E R S Euro Marché center
King Abdulla road & Osman Ibn Afan road junction
Riyadh, Saudi arabia
Contractor Consultant:
2L
2L120x12x10
2L
10
10
2L
2L
2L
2L
0
x1
x1
2L90x9x10
0
10
2L80x8x10
10
x
x1
10
10
x1
HEA 140
10
10
90
90
HEB 400
10
10
0x
0x
x9
0
0
x9
Dar al Handasah (Shair
x
0x
0x
x1
0x
0x
x1
10
90
9x
9x
10
90
3222
3222
10
10
0x
10
10
0x
& Partners)
10
10
2L
x
2L
10
10
10
10
2L
2L
2L
2L
King Fahd Rd., Olaya, Al-
HEA 180 HEA 180 HEA 180 Mass Centre
+33.000 P.O. Box: 612, Riyadh 11421
C.L.
300
300
Notes/Legends:
2- ALL BUILT-UP & HOT ROLLED SECTIONS ARE TO BE ASTM A572 GR.50
WITH A MINIMUM YIELD STRESS OF 345 N/mm2.
2L
10
10
0 10 0 LEVELS SHOULD BE COORDINATED WITH RELEVANT CONCRETE
2L
8 x1 8
10
9 x1
12
2L
x
2L90x9x10
0x 0x x
x
0x
2L70x7x10
12
HEA 140
8
12
12
x8 x9
9x
0x
90
DRAWINGS.
8x 0x 8x 9
0x
HEB 400
HEB 360
80
0x
0x
x1 0
x
12
x9
10 8 10
90
9
12
2L 2L
12
12
0
2980
2980
2L
x1
x1
2L
2L
2L
x1
0
10- FOR MAIN TRUSSES CAMBERING SCHEME REFER TO DRAWING NO:
0
HEA 240 HEA 240 HEA 240 SHO001-NAP-IFC-M2-06-RCM-DR-SS-3003-03-00.
+33.000
C.L. 11- SPLICE LOCATIONS FOR THE CHORDS OF THE MAIN TRUSSES ARE
TENTATIVE, AND TO BE AS PER FABRICATOR PREFERENCE.
SECTION W-W
SCALE 1/100
2L150x15x10
80 10 x1 10 0 10 0
2L70x7x10
0x 80 x1 80 0x x1
2L80x8x10
8x 10 0x
HEA 140
x8 0x 0x 8
HEB 300
1 x x x8 x8 1
x1 0x 10 0 8x 0 x 10 0x 10 0x
10 x1 L8 10 10 x 10 80 x1
10 x1 8
0 0 2L
2728
2728
2L 0 2 2L 2L 2L 0
HEA 240 HEA 240 B4
+33.000
MALL
C.L.
300
300
B B Project Name:
HEA 300
HEA 240
HEA 300
HEA 300
HEB 220
2482
2482
+33.000
C.L.
CAMBERING SCHEME FOR TRUSSES "19 & 20" CAMBERING SCHEME FOR TRUSSE "18" B13 2FLGS 320x13 - WEB 244x8 PLOT 06
CAMBERING SCHEME FOR TRUSSE "17" B14 2FLGS 300x13 - WEB 244x8 CINEMA ROOF
SCALE 1/100 SCALE 1/100
SCALE 1/100 B15 2FLGS 340x13 - WEB 244x8 SECTION 3 OF 3
B16 2FLGS 340x16 - WEB 238x10
B22 2FLGS 220x10 - WEB 170x6.5 SHO001 NAP IFC M2 06 RCMDR SS 3003 03 01
5 4 3 2 1