MITRA AUSINDO INDONESIA

Dragon Industrial Park Blok A No.06 Kabil , Batam Island – Indonesia


Tel. 0778 748 6730 / HP 081991119099
Email : marketing@mitraausindo.com

INSPECTION REPORT
CLIENT : PT. RAINBOW TUBULAR MANUFACTURE
Kawasan Perindustrian Latrade Blok G no.6-7 Batuaji,
Batam, Indonesia.
TYPE OF INSPECTION : Function Test
REFERENCES : Per.Men. Tenaga Kerja & Transmigrasi Republik
Indonesia Th.2020 Tentang K3 Pesawat Angkat Angkut
Item : Overhead Crane
S/No : Crane No. 05

Identification of any part found to have a defect which is or could become a danger to persons and a
description of the defect (if none state NONE), also the requirements to rectify the defect:
Finding
• Found Brake for Travelling not working
• Motor Hoist Brake Fail While Load Test 10 Ton
Any other observations or recommendations not affecting the safe use of the equipment:
YES, Please repair braking system for Motor Brake and Travelling movement
Inspection & Examination By Date of examination

15 May 2023

Ihwan
NO. KEP. 000271022/A-APAA/21/X/2022
MITRA AUSINDO INDONESIA
Dragon Industrial Park Blok A No.06 Kabil , Batam Island – Indonesia
Tel. 0778 748 6730 / HP 081991119099
Email : marketing@mitraausindo.com

INSPECTION REPORT
CLIENT : PT. RAINBOW TUBULAR MANUFACTURE
Kawasan Perindustrian Latrade Blok G no.6-7 Batuaji,
Batam, Indonesia.
TYPE OF INSPECTION : Visual Inspection
REFERENCES : Per.Men. Tenaga Kerja & Transmigrasi Republik
Indonesia Th.2020 Tentang K3 Pesawat Angkat Angkut
Item : Overhead Crane
S/No : Crane No. 10

Identification of any part found to have a defect which is or could become a danger to persons and a
description of the defect (if none state NONE), also the requirements to rectify the defect:
Found Broken Wire sling due to fatigue and continued of use, and Safety Latch not installed
Any other observations or recommendations not affecting the safe use of the equipment:
YES, Please change wire slings with dia. 10mm, install safety latch and make sure limit switch and hoist
brake in a good condition
Inspection & Examination By Date of examination

26 July 2023

Ihwan
NO. KEP. 000271022/A-APAA/21/X/2022
MITRA AUSINDO INDONESIA
Dragon Industrial Park Blok A No.06 Kabil , Batam Island – Indonesia
Tel. 0778 748 6730 / HP 081991119099
Email : marketing@mitraausindo.com

INSPECTION REPORT
CLIENT : PT. RAINBOW TUBULAR MANUFACTURE
Kawasan Perindustrian Latrade Blok G no.6-7 Batuaji,
Batam, Indonesia.
TYPE OF INSPECTION : Visual Inspection
REFERENCES : Per.Men. Tenaga Kerja & Transmigrasi Republik
Indonesia Th.2020 Tentang K3 Pesawat Angkat Angkut
Item : Overhead Crane
S/No : Crane No. 11
SWL : 5 Ton

Identification of any part found to have a defect which is or could become a danger to persons and a
description of the defect (if none state NONE), also the requirements to rectify the defect:
Finding
• Reduction wire sling diameter more than 5 %
• Load limiter not installed
• alarm for travelling not installed

Any other observations or recommendations not affecting the safe use of the equipment:
YES, Please quarantine the crane and shall do repair of the finding, install safety latch and make sure all
limiters are installed, replace wire sling hoist and use correct wire clip/swaged socket for wire
installation
Inspection & Examination By Date of examination

26 July 2023

Ihwan
NO. KEP. 000271022/A-APAA/21/X/2022
MITRA AUSINDO INDONESIA
Dragon Industrial Park Blok A No.06 Kabil , Batam Island – Indonesia
Tel. 0778 748 6730 / HP 081991119099
Email : marketing@mitraausindo.com

INSPECTION REPORT
CLIENT : PT. RAINBOW TUBULAR MANUFACTURE
Kawasan Perindustrian Latrade Blok G no.6-7 Batuaji,
Batam, Indonesia.
TYPE OF INSPECTION : Visual Inspection
REFERENCES : Per.Men. Tenaga Kerja & Transmigrasi Republik
Indonesia Th.2020 Tentang K3 Pesawat Angkat Angkut
Item : Overhead Crane
S/No : Crane No. 12

Identification of any part found to have a defect which is or could become a danger to persons and a
description of the defect (if none state NONE), also the requirements to rectify the defect:
Finding
• Motor Hoist Brake Fail While Load Test 10 Ton
Any other observations or recommendations not affecting the safe use of the equipment:
YES, Please quarantine and shall do repair of the finding, install safety latch and make sure limit switch
and hoist brake in a good condition
Inspection & Examination By Date of examination

26 July 2023

Ihwan
NO. KEP. 000271022/A-APAA/21/X/2022