Ratings Range: Tier 4 EPA-Certified For Stationary, Prime, Continuous Applications
Ratings Range: Tier 4 EPA-Certified For Stationary, Prime, Continuous Applications
Ratings Range: Tier 4 EPA-Certified For Stationary, Prime, Continuous Applications
Ratings Range
60 Hz
Standby: kW 1180- 1250
kVA 1475- 1562
Prime: kW 1070- 1130
kVA 1338- 1412
Continuous: kW 920- 970
kVA 1150- 1212
RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for
this rating. Prime Power Ratings: At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with
ISO-8528-1 and ISO-3046-1. For limited running time and continuous ratings, consult the factory. Obtain technical information bulletin (TIB-101) for ratings guidelines, complete ratings definitions, and
site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.
G5-614 (KD1250- 4) 10/22d Page 1
523 (29742)651 (37021)
Industrial Diesel Generator Set - KD1250-4
Tier 4 EPA-Certified for Stationary, Prime, Continuous Applications
80_C Rise
150_C Rise 130_C Rise 125_C Rise 105_C Rise Continuous
Standby Rating Standby Rating Prime Rating Prime Rating Rating
Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps kW/kVA Amps kW/kVA Amps kW/kVA Amps
220/380 3 60 1250/1562 2374 1250/1562 2374 1130/1412 2146 1130/1412 2146 960/1200 1824
240/416 3 60 1250/1562 2168 1250/1562 2168 1130/1412 1960 1130/1412 1960 960/1200 1666
KH05520TO4D
277/480 3 60 1250/1562 1879 1250/1562 1879 1130/1412 1699 1130/1412 1699 970/1212 1458
347/600 3 60 1250/1562 1504 1250/1562 1504 1130/1412 1359 1130/1412 1359 960/1200 1155
220/380 3 60 1250/1562 2374 1250/1562 2374 1130/1412 2146 1130/1412 2146 970/1212 1842
240/416 3 60 1250/1562 2168 1250/1562 2168 1130/1412 1960 1130/1412 1960 970/1212 1683
KH06810TO4D
277/480 3 60 1250/1562 1879 1250/1562 1879 1130/1412 1699 1130/1412 1699 970/1212 1458
347/600 3 60 1250/1562 1504 1250/1562 1504 1130/1412 1359 1130/1412 1359 970/1212 1167
KH05641TO4D 2400/4160 3 60 1250/1562 217 1250/1562 217 1130/1412 196 1130/1412 196 950/1188 165
KH06721TO4D 2400/4160 3 60 1250/1562 217 1250/1562 217 1130/1412 196 1130/1412 196 950/1188 165
Exhaust System 60 Hz
Exhaust flow at rated kW, m3/min. (cfm) 250 (8840)
Exhaust temperature at rated kW at
25_C (77_F) ambient, dry exhaust,
_C (_F) 520 (968)
Maximum allowable back pressure,
kPa (in. Hg) See TIB- 119
Exh. outlet size at eng. hookup, mm (in.) See ADV drawing
Air Requirements 60 Hz D Brushless alternator with brushless pilot exciter for excellent
load response.
Radiator-cooled cooling air,
m3/min. (scfm)] 1470 (51913) NOTE: See TIB- 102 Alternator Data Sheets for alternator
Cooling air required for generator set application data and ratings, efficiency curves, voltage dip with
when equipped with city water cooling or motor starting curves, and short circuit decrement curves.
remote radiator, based on 14_C (25_F)
rise, m3/min. (scfm)] 938 (33131)
Combustion air, m3/min. (cfm) ESP & PRP 90.2 (3185)
COP 81.8 (2890)
Heat rejected to ambient air:
Engine, kW (Btu/min.) 171 (9733)
Alternator, kW (Btu/min.) 93 (5325)
] Air density = 1.20 kg/m3 (0.075 lbm/ft3)
Available Options
Circuit Breakers Fuel System
Type Rating - Flexible Fuel Lines
- Magnetic Trip - 80% - Dual Fuel/Water Separator
- Thermal Magnetic Trip - 100% - Restriction Gauge (for fuel/water separator)
- Electronic Trip (LI) Operation Literature
- Electronic Trip with - Manual - General Maintenance
Short Time (LSI) - Electrically Operated (for paralleling)
- NFPA 110
- Electronic Trip with
Ground Fault (LSIG) - Overhaul
Circuit Breaker Mounting - Production
- Generator Mounted Miscellaneous
- Remote Mounted - Air Cleaner, Heavy Duty
- Bus Bar (for remote mounted breakers) - Air Cleaner Restriction Indicator
Enclosed Remote Mounted Circuit Breakers - Alternator Air Filter (will reduce generator set rating up to 7%)
- NEMA 1 (15- 5000 A) - Automatic Oil Replenishment System
- NEMA 3R (15- 1200 A) - Rated Power Factor Testing
- Weld- On Flange, DIN300
Engine Type - Weld- On Flange, DEF Tank
- KDxxxx Tier 4 EPA-Certified Engine Electrical Package
Approvals and Listings - Basic Electrical Package (select 1 Ph or 3 Ph)
- CSA Certified - Wire Battery Charger (1 Ph)
- IBC Certification Request—Contact Factory - Wire Block Heater (select 1 Ph or 3 Ph)
- UL 2200 Listing - Wire Power Supply
- cULus - Wire Generator Heater (1 Ph)
- Florida Dept. of Environmental Protection (FDEP) Compliance Warranty (Standby Applications only)
(fuel tanks only)
- 5-Year Basic Limited Warranty
- Hurricane Rated Enclosure
- 5-Year Comprehensive Limited Warranty
Enclosed Unit - 10-Year Major Components Limited Warranty
- Sound Level 2 Enclosure/Fuel Tank Package Warranty (Prime Applications only)
Controller - 5-Year Basic Limited Warranty
- Input/Output, Digital - 5-Year Comprehensive Limited Warranty
- Input/Output, Thermocouple (standard on 4160 V) Other
- Input/Output, Expansion -
- Manual Key Switch
Dimensions and Weights
- Remote Emergency Stop Switch
Generator set size, max.,
- Lockable Emergency Stop Switch
L1 x W x H1, mm (in.): 5179 x 2452 x 2480
- Remote Serial Annunciator Panel (203.9 x 96.5 x 97.6)
With rear- facing SCR, max.,
Cooling System L2 x W x H2, mm (in.): 7592 x 2452 x 5325
- Block Heater; 9000 W, 208 V, (Select 1 Ph or 3 Ph) * (298.9 x 96.5 x 210.7)
- Block Heater; 9000 W, 240 V, (Select 1 Ph or 3 Ph) * With forward- facing SCR, max.,
L2 x W x H2, mm (in.): 6470 x 2452 x 5325
- Block Heater; 9000 W, 480 V, (Select 1 Ph or 3 Ph) * (254.7 x 96.5 x 210.7)
* Required for ambient temperatures below 10_C (50_F). Weight, radiator model, max. wet, kg (lb.): 11914 (26265)
Block heater kit includes air intake manifold grid heater. Weight, with radiator and SCR, max. wet, kg (lb.): 12740 (28087)
- Radiator Guard and Duct Flange
Electrical System
- Battery, AGM (kit with qty. 4)
- Battery, AGM (kit with qty. 8)
H2
- Battery Charger
- Battery Heater; 80 W, 120 V, 1Ph
- Redundant Starters H1
- DEF Tank Heater
- Load Bank, 300 kW / 350 kW
[Recommended for Ambient Temperature > - 5_C (23_F)] W L1
- Load Bank, 600 kW /650 kW L2
[Recommended for Ambient Temperature < - 5_C (23_F)] NOTE: This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
G5-614 (KD1250- 4) 10/22d Page 5
Industrial Diesel Generator Set - KD1250-4
Tier 4 EPA-Certified for Stationary, Prime, Continuous Applications
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KOHLERPower.com