AC 01.2/ACExC 01.2/ACV 01.2/ACVExC 01.

Wiring diagram code

Extract of wiring diagram code


Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Position I/O interface TPC A – 0 A 1 – 1 C 1 – A 0 0 0
Profibus DP TPC A A 0 0 0 – 1 A 1 – A 0 0 0
1 Controls type
A AC 01.2/ACExC 01.2
H ACV 01.2/ACVExC
2 Interface to the distributed control system
– I/O interface
A Profibus DP
C Modbus RTU/Modbus TCP/IP
F Foundation Fieldbus
I HART Connection Type: Actuator
J HART Current Output
N Profinet
3 Analogue inputs
0 Without
1 4 – 20 mA for positioner
A With 2 free analogue inputs
4 Digital inputs
A CLOSE, OPEN, STOP, EMERGENCY
B With positioner: MODE, CLOSE, OPEN, STOP, EMERGENCY
0 Without
1 With 4 free digital inputs
2 With 6 inputs: MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O interface
4 With 5 inputs: CLOSE, OPEN, STOP, EMERGENCY, I/O interface
5 Output contacts, position and torque feedback signals (0/4 – 20 mA)
1 / D 5 NO contacts, 1 change-over contact, position feedback signal
torque feedback signal (in combination with MWG)
0 Without
6 Additional equipment
– Without
K Profinet, 2xIEEE 802.3
7 Local controls
1 Push buttons OPEN, STOP, CLOSE, RESET, selector switch LOCAL - OFF - REMOTE, display,
5 indication lights
8 Auxiliary voltage for supply of digital inputs
A Without
C 24 V DC
9 Switchgear
1 Reversing contactors max. AUMA power class A3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC
motor)
2 Thyristors max. AUMA power class A3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC motor)
3 Thyristors max. AUMA power class B3 (refer to Electrical data SA .2/SAR .2 with 3-phase AC motor)
4 Thyristors with additional tripping max. AUMA power class B2 (refer to Electrical data SA .2/SAR .2 with
3-phase AC motor)
5 Thyristors with additional tripping max. AUMA power class B3 (refer to Electrical data SA .2/SAR .2 with
3-phase AC motor)
E Power electronics 1-ph1)
F Power electronics 3-ph1)

1) Refer to notes on page 2.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y005.293/003/en Issue 1.18 Page 1/2


AC 01.2/ACExC 01.2/ACV 01.2/ACVExC 01.2

Wiring diagram code

Extract of wiring diagram code


Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Position I/O interface TPC A – 0 A 1 – 1 C 1 – A 0 0 0
Profibus DP TPC A A 0 0 0 – 1 A 1 – A 0 0 0
10 Motor protection evaluation
– Thermoswitches (standard for AC 01.2), refer to wiring diagram TPA
1 Thermoswitch with thermal overload relay
– PTC thermistors with tripping device (standard for ACExC), refer to TPA terminal plan
11 Heater
A Internally supplied within the switch compartment of the actuator
12 – 14 Control elements
000 Without
A20 KP suitable wiring
5E0 Modbus TCP/IP
5EF Modbus TCP/IP Ex
410 Profibus Ex
460 Profibus Ex, KP suitable wiring

Notes on tables on page 1


1) In combination with ACV 01.2 only.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y005.293/003/en Issue 1.18 Page 2/2