B-64700EN/01 4.

DESCRIPTION OF PARAMETERS

NOTE
When a position coder is attached to the spindle, set the same value
for all of parameters Nos. 5221 to 5224.

5231 Number of gear teeth on the position coder side in rigid tapping (first gear)

5232 Number of gear teeth on the position coder side in rigid tapping (second gear)

5233 Number of gear teeth on the position coder side in rigid tapping (third gear)

Number of gear teeth on the position coder side in rigid tapping (fourth gear)
5234

[Input type] Parameter input


[Data type] Word spindle
[Valid data range] 1 to 32767
Each of these parameters is used to set the number of gear teeth on the position coder side
for each gear in rigid tapping.

NOTE
When a position coder is attached to the spindle, set the same value
for all of parameters Nos. 5231 to 5234.

5241 Maximum spindle speed in rigid tapping (first gear)

5242 Maximum spindle speed in rigid tapping (second gear)

5243 Maximum spindle speed in rigid tapping (third gear)

Maximum spindle speed in rigid tapping (fourth gear)


5244

[Input type] Parameter input


[Data type] 2-word spindle
[Unit of data] min-1
[Valid data range] 0 to 9999
Spindle position coder gear ratio
1 : 1 0 to 7400
1 : 2 0 to 9999
1 : 4 0 to 9999
1 : 8 0 to 9999
Each of these parameters is used to set a maximum spindle speed for each gear in rigid
tapping.
Set the same value for both parameter No. 5241 and parameter No. 5243 for a one-stage
gear system. For a two-stage gear system, set the same value as set in parameter No. 5242
in parameter No. 5243. Otherwise, alarm PS0200, “ILLEGAL S CODE COMMAND”
will be issued. This applies to the M series.

5260 Minimum torque overrides at acceleration/deceleration in rigid tapping

[Input type] Parameter input


[Data type] Byte spindle
[Unit of data] %
[Valid data range] 0 to 100
Set minimum torque override at acceleration/deceleration in rigid tapping.