DESCRIPTION OF PARAMETERS
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets a tapping axis in-position width when rigid tapping is performed
using the third spindle.
If the setting value is negative value, in-position check is not completed.
5310 Positional deviation limit imposed during tapping axis movement in rigid tapping (first spindle)
NOTE
Set the following parameter for each spindle:
First spindle No. 5310
Second spindle No. 5350
Third spindle No. 5354
Fourth spindle No. 5358
5311 Limit value of spindle positioning deviation during movement in rigid tapping
- 307 -